Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Neuroimage ; 186: 399-409, 2019 02 01.
Article in English | MEDLINE | ID: mdl-30342237

ABSTRACT

PURPOSE: The lateral geniculate nucleus (LGN) is an essential nucleus of the visual pathway, occupying a small volume (60-160 mm3) among the other thalamic nuclei. The reported LGN volumes vary greatly across studies due to technical limitations and due to methodological differences of volume assessment. Yet, structural and anatomical alterations in ophthalmologic and neurodegenerative pathologies can only be revealed by a precise and reliable LGN representation. To improve LGN volume assessment, we first implemented a reference acquisition for LGN volume determination with optimized Contrast to Noise Ratio (CNR) and high spatial resolution. Next, we compared CNR efficiency and rating reliability of 3D Magnetization Prepared Rapid Gradient Echo (MPRAGE) images using white matter nulled (WMn) and grey matter nulled (GMn) sequences and its subtraction (WMn-GMn) relative to the clinical standard Proton Density Turbo Spin Echo (PD 2D TSE) and the reference acquisition. We hypothesized that 3D MPRAGE should provide a higher CNR and volume determination accuracy than the currently used 2D sequences. MATERIALS AND METHODS: In 31 healthy subjects, we obtained at 3 and 7 T the following MR sequences: PD-TSE, MPRAGE with white/grey matter signal nulled (WMn/GMn), and a motion-corrected segmented MPRAGE sequence with a resolution of 0.4 × 0.4 × 0.4 mm3 (reference acquisition). To increase CNR, GMn were subtracted from WMn (WMn-GMn). Four investigators manually segmented the LGN independently. RESULTS: The reference acquisition provided a very sharp depiction of the LGN and an estimated mean LGN volume of 124 ±â€¯3.3 mm3. WMn-GMn had the highest CNR and gave the most reproducible LGN volume estimations between field strengths. Even with the highest CNR efficiency, PD-TSE gave inconsistent LGN volumes with the weakest reference acquisition correlation. The LGN WM rim induced a significant difference between LGN volumes estimated from WMn and GMn. WMn and GMn LGN volume estimations explained most of the reference acquisition volumes' variance. For all sequences, the volume rating reliability were good. On the other hand, the best CNR rating reliability, LGN volume and CNR correlations with the reference acquisition were obtained with GMn at 7 T. CONCLUSION: WMn and GMn MPRAGE allow reliable LGN volume determination at both field strengths. The precise location and identification of the LGN (volume) can help to optimize neuroanatomical and neurophysiological studies, which involve the LGN structure. Our optimized imaging protocol may be used for clinical applications aiming at small nuclei volumetric and CNR quantification.


Subject(s)
Geniculate Bodies/anatomy & histology , Geniculate Bodies/diagnostic imaging , Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Adolescent , Adult , Female , Humans , Image Enhancement , Male , Middle Aged , Reference Standards , Reproducibility of Results , Signal-To-Noise Ratio , Young Adult
2.
Disabil Rehabil Assist Technol ; 10(5): 385-92, 2015.
Article in English | MEDLINE | ID: mdl-24730659

ABSTRACT

PURPOSE: To evaluate feasibility and neurophysiological changes after virtual reality (VR)-based training of upper limb (UL) movements. METHOD: Single-case A-B-A-design with two male stroke patients (P1:67 y and 50 y, 3.5 and 3 y after onset) with UL motor impairments, 45-min therapy sessions 5×/week over 4 weeks. Patients facing screen, used bimanual data gloves to control virtual arms. Three applications trained bimanual reaching, grasping, hand opening. Assessments during 2-week baseline, weekly during intervention, at 3-month follow-up (FU): Goal Attainment Scale (GAS), Chedoke Arm and Hand Activity Inventory (CAHAI), Chedoke-McMaster Stroke Assessment (CMSA), Extended Barthel Index (EBI), Motor Activity Log (MAL). Functional magnetic resonance imaging scans (FMRI) before, immediately after treatment and at FU. RESULTS: P1 executed 5478 grasps (paretic arm). Improvements in CAHAI (+4) were maintained at FU. GAS changed to +1 post-test and +2 at FU. P2 executed 9835 grasps (paretic arm). CAHAI improvements (+13) were maintained at FU. GAS scores changed to -1 post-test and +1 at FU. MAL scores changed from 3.7 at pre-test to 5.5 post-test and 3.3 at FU. CONCLUSION: The VR-based intervention was feasible, safe, and intense. Adjustable application settings maintained training challenge and patient motivation. ADL-relevant UL functional improvements persisted at FU and were related to changed cortical activation patterns. Implications for Rehabilitation YouGrabber trains uni- and bimanual upper motor function. Its application is feasible, safe, and intense. The control of the virtual arms can be done in three main ways: (a) normal (b) virtual mirror therapy, or (c) virtual following. The mirroring feature provides an illusion of affected limb movements during the period when the affected upper limb (UL) is resting. The YouGrabber training led to ADL-relevant UL functional improvements that were still assessable 12 weeks after intervention finalization and were related to changed cortical activation patterns.


Subject(s)
Computer Simulation , Physical Therapy Modalities , Stroke Rehabilitation , Upper Extremity , User-Computer Interface , Activities of Daily Living , Chronic Disease , Feasibility Studies , Humans , Magnetic Resonance Imaging , Male , Middle Aged , Recovery of Function , Stroke/physiopathology
SELECTION OF CITATIONS
SEARCH DETAIL
...