Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 48
Filter
Add more filters










Publication year range
1.
Environ Sci Process Impacts ; 25(8): 1263-1287, 2023 Aug 16.
Article in English | MEDLINE | ID: mdl-37491999

ABSTRACT

Oxidized compounds in the atmosphere can occur as emitted primary compounds or as secondary products when volatile emitted precursors react with various oxidants. Due to the presence of polar functional groups, their vapor pressures decrease, and they condense onto small particles. Thereby, they have an effect on climate change by the formation of clouds and scattering solar radiation. The particles and oxidized compounds themselves can cause serious health problems when inhaled. Therefore, it is of utmost importance to study oxidized compounds in the atmosphere. Much ongoing research is focused on the discovery of new oxidized substances and on the evaluation of their sources and factors influencing their formation. Monitoring biogenic and anthropogenic primary oxidized compounds or secondary oxidized products in chamber experiments or field campaigns is common. New discoveries have been reported, including various oxidized compounds and a new group of compounds called highly oxidized organic molecules (HOMs). Analytics of HOMs are mainly focused on chromatography and high-resolution mass spectrometry employing chemical ionization for identifying and quantifying compounds at low concentrations. Oxidized compounds can also be monitored by spectrophotometric methods in which the determinations of total amounts are based on functional groups. This review highlights recent findings on oxidized organic compounds in the atmosphere and analytical methodologies used for their detection and quantification. The discussion includes gas and liquid chromatographic methods, sampling, extraction, concentration, and derivatization procedures involved, as well as mass spectrometric and spectrophotometric methods.


Subject(s)
Organic Chemicals , Volatile Organic Compounds , Organic Chemicals/analysis , Mass Spectrometry , Atmosphere/chemistry , Aerosols/chemistry , Volatile Organic Compounds/analysis
2.
J Chromatogr A ; 1703: 464119, 2023 Aug 16.
Article in English | MEDLINE | ID: mdl-37271082

ABSTRACT

The adsorption and desorption behavior of volatile nitrogen-containing compounds in vapor phase by solid-phase microextraction Arrow (SPME-Arrow) and in-tube extraction (ITEX) sampling systems, were investigated experimentally using gas chromatography-mass spectrometry. Three different SPME-Arrow coating materials, DVB/PDMS, MCM-41, and MCM-41-TP and two ITEX adsorbents, TENAX-GR and MCM-41-TP were compared to clarify the selectivity of the sorbents towards nitrogen-containing compounds. In addition, saturated vapor pressures for these compounds were estimated, both experimentally and theoretically. In this study, the adsorption of nitrogen-containing compounds on various adsorbents followed the Elovich model well, while a pseudo-first-order kinetics model best described the desorption kinetics. Pore volume and pore sizes of the coating sorbents were essential parameters for the determination of the adsorption performance for the SPME-Arrow sampling system. MCM-41-TP coating with the smallest pore size gave the slowest adsorption rate compared to that of DVB/PDMS and MCM-41 in the SPME-Arrow sampling system. Both adsorbent and adsorbate properties, such as hydrophobicity and basicity, affected the adsorption and desorption kinetics in SPME-Arrow system. The adsorption and desorption rates of studied C6H15N isomers in the MCM-41 and MCM-41-TP sorbent materials of SPME-Arrow system were higher for dipropylamine and triethylamine (branched amines) than for hexylamine (linear chain amines). DVB/PDMS-SPME-Arrow gave fast adsorption rates for the aromatic-ringed pyridine and o-toluidine. All studied nitrogen-containing compounds demonstrated high desorption rates with DVB/PDMS-SPME-Arrow. Chemisorption and physisorption were the sorption mechanisms in MCM-41- and MCM-41-TP- SPME-Arrow, but additional experiments are needed to confirm this. An active sampling technique ITEX gave comparable adsorption and desorption rates on the selective MCM-41-TP and universal TENAX-GR sorbent materials for all the compounds studied. Vapor pressures of nitrogen-containing compounds were experimentally estimated by using retention index approach and these values were compared with the theoretical ones, calculated using the COnductor-like Screening MOdel for Real Solvent (COSMO-RS) model. Both values agreed well with those found in the literature proving that these methods can be successfully used in predicting VOC's vapor pressures, e.g. for the formation of secondary organic aerosols.


Subject(s)
Gases , Nitrogen Compounds , Amines/analysis , Solid Phase Microextraction/methods , Nitrogen
3.
Environ Res ; 224: 115494, 2023 05 01.
Article in English | MEDLINE | ID: mdl-36804318

ABSTRACT

Solid phase microextraction Arrow and thermal desorption-gas chromatography-mass spectrometry allowed the collection and evaluation of volatile organic compounds (VOCs) emitted by fungal cultures from building insulation materials and in indoor air. Principal component analysis, linear discriminant analysis and supported vector machine were used for visualization and statistical assessment of differences between samples. In addition, a screening tool based on the soft independent modelling of class analogies (SIMCA) was developed for identification of fungal contamination of indoor air. Ten different fungal strains, incubated under ambient and microaerophilic conditions, were analyzed for time period ranging from 5 to 29 days after inoculation resulting in a total of 140 samples. In addition, the effect of additives on the fungal growing media was studied. The total number of compounds and concentration values were used for the evaluation of the results. Clear differences were observed for VOC profiles emitted by different fungal strains by exploiting long chain alcohols (3-octanol, 1-hexanol and 2-octen-1-ol) and sesquiterpenes (farnesene, cuprene). The analysis of glass-wool and cellulose based building insulation materials (3 samples) gave clear differences, mainly for oxygenated compounds (ethyl acetate and hexanal) and benzenoids (benzaldehyde). Moreover, the comparison of indoor air and insulation materials collected from a house with fungal indoor air problems indicated that 42% of the VOCs were found in both samples. The analysis of 52 indoor air samples demonstrated clear differences in their VOC profiles, especially for hydrocarbons, and between control (44 samples) and indoor air problem houses (8 samples). Finally, the SIMCA model enabled to recognize differences between control and fungi contaminated houses with a prediction capacity over 84%.


Subject(s)
Air Pollution, Indoor , Volatile Organic Compounds , Animals , Volatile Organic Compounds/analysis , Gas Chromatography-Mass Spectrometry , Air Pollution, Indoor/analysis , Solid Phase Microextraction , Fungi
4.
Sci Rep ; 12(1): 22534, 2022 12 29.
Article in English | MEDLINE | ID: mdl-36581644

ABSTRACT

We have measured the changes in the production of volatile organic compounds (VOCs) by the oral pathogen Porphyromonas gingivalis, when treated in vitro with the antibiotic amoxicillin. We have also measured the VOC production of P. gingivalis grown in the presence and absence of supplemental hemin. Planktonic bacterial cultures were treated with different amounts of amoxicillin in the lag phase of the bacterial growth. Planktonic bacteria were also cultured with and without supplemental hemin in the culture medium. Concentrations of VOCs were measured with proton-transfer-reaction time-of-flight mass spectrometry (PTR-ToF-MS) and further molecular identification was done with gas chromatography-mass spectrometry (GC-MS) using solid phase microextraction (SPME) for sampling. The cell growth of P. gingivalis in the cultures was estimated with optical density measurements at the wavelength of 600 nm (OD600). We found that the production of methanethiol, hydrogen sulfide and several short- to medium-chain fatty acids was decreased with antibiotic treatment using amoxicillin. Compounds found to increase with the antibiotic treatment were butyric acid and indole. In cultures without supplemental hemin, indole and short- to medium-chain fatty acid production was significantly reduced. Acetic acid production was found to increase when supplemental hemin was not available. Our results suggest that the metabolic effects of both antibiotic treatment and supplemental hemin availability are reflected in the VOCs produced by P. gingivalis and could be used as markers for bacterial cell growth and response to threat. Analysis of these volatiles from human samples, such as the exhaled breath, could be used in the future to rapidly monitor response to antibacterial treatment.


Subject(s)
Volatile Organic Compounds , Humans , Volatile Organic Compounds/analysis , Anti-Bacterial Agents/pharmacology , Bacteria/metabolism , Amoxicillin/pharmacology , Fatty Acids , Butyric Acid , Indoles
5.
Sci Total Environ ; 808: 152011, 2022 Feb 20.
Article in English | MEDLINE | ID: mdl-34861308

ABSTRACT

A wide variety of nitrogen-containing compounds are present in the environment, which contributes to air pollution and new particle formation, for example. These eventually affect human health and the climate. With all this consideration, there is a growing interest in the development of efficient and reliable methods to determine these compounds in the atmosphere. In this study, titanium hydrogen phosphate-modified Mobil Composition of Matter No. 41 was used as sorbent material for in-tube extraction (ITEX) sampling system, to selectively collect nitrogen-containing compounds from natural air samples. The effect of sampling accessories, based on adsorbent coatings (with Tenax-GR as an adsorbent material) and polytetrafluoroethylene filters, was studied to improve the selectivity of the sampling system and to remove particles. Aerial drone with miniaturized air sampling system was employed for the reliable collection of nitrogen-containing compounds in both gas phase and aerosol particles. A total of 170 air samples were collected in July 2020 at the SMEAR II station, Finland to evaluate nitrogen-containing compounds diurnal patterns and vertical profiles (0.25, 5, 50, and 150 m). More than twenty nitrogen-containing compounds, such as aliphatic amines, imines, imidazoles, and pyridines, were identified, quantified or semi-quantified. The average concentrations of detected aliphatic amines at the altitude of 50 m were up to 40.4 ng m-3 (dimethylamine) in gas phase and 128 ng m-3 (ethylamine) in aerosol particles. Among nitrogen-containing compounds detected, pyridine gave the highest average concentration of 746 ng m-3 in gas phase and 644 ng m-3 in particle phase.


Subject(s)
Air Pollutants , Air Pollution , Air Pollutants/analysis , Environmental Monitoring , Humans , Nitrogen , Nitrogen Compounds , Taiga , Unmanned Aerial Devices
6.
Sci Rep ; 11(1): 16897, 2021 08 19.
Article in English | MEDLINE | ID: mdl-34413397

ABSTRACT

We have measured the volatile fingerprints of four pathogenic oral bacteria connected to periodontal disease and dental abscess: Porphyromonas gingivalis (three separate strains), Prevotella intermedia, Prevotella nigrescens and Tannerella forsythia. Volatile fingerprints were measured in vitro from the headspace gas of the bacteria cultured on agar. Concrete identification of new and previously reported bacterial volatiles were performed by a combination of solid phase microextraction (SPME) and offline gas chromatography-mass spectrometry (GC-MS). We also studied the effect of the reduced electric field strength (E/N) on the fragmentation patterns of bacterial volatiles in online proton-transfer-reaction time-of-flight mass spectrometry (PTR-ToF-MS). We aimed to discover possible new biomarkers for the studied oral bacteria, as well as to validate the combination of GC-MS and PTR-MS for volatile analysis. Some of the most promising compounds produced include: 1-Methyl-1,2,3,4-tetrahydroisoquinoline (1MeTIQ), indole, and a cascade of sulphur compounds, such as methanethiol, dimethyl disulphide (DMDS) and dimethyl trisulphide (DMTS). We also found that several compounds, especially alcohols, aldehydes and esters, fragment significantly with the PTR-MS method, when high E/N values are used. We conclude that the studied oral bacteria can be separated by their volatile fingerprints in vitro, which could have importance in clinical and laboratory environments. In addition, using softer ionization conditions can improve the performance of the PTR-MS method in the volatile analysis of certain compounds.


Subject(s)
Bacteria/chemistry , Biomarkers/analysis , Gas Chromatography-Mass Spectrometry , Mouth/microbiology , Protons , Volatile Organic Compounds/analysis
7.
Chemosphere ; 282: 131024, 2021 Nov.
Article in English | MEDLINE | ID: mdl-34119722

ABSTRACT

Our second generation air sampling drone system, allowing the simultaneous use of four solid phase microextraction (SPME) Arrow and four in-tube extraction (ITEX) units, was employed for collection of atmospheric air samples at different spatial and temporal dimensions. SPME Arrow coated with two types of materials and ITEX with 10% polyacrylonitrile as sorbent were used to give a more comprehensive chemical characterization of the collected air samples. Before field sampling, miniaturized samplers went through quality control and assurance in terms of reproducibility (RSD ≤14.1%, N = 4), equilibrium time (≥10 min), breakthrough volume (1.8 L) and storage time (up to 48 h). 128 air samples were collected under optimal sampling conditions from July to September 2019 at the SMEAR II station and Qvidja farm, Finland. 347 VOCs were identified in the air samples either on-site or in the laboratory by thermal desorption gas chromatography - mass spectrometry, and they were quantified/semiquantified using Partial Least Squares Regression models. Individual models were developed for the different coatings and packing materials using gas phase standards obtained by an automatic permeation system. Average gas phase VOC concentrations ranged from 0.1 (toluene, the SMEAR II station) to 680 ng L-1 (acetone, Qvidja farm). Average VOC concentrations in aerosols ranged from 0.1 (1,4-cyclohexadiene, the SMEAR II station) to 2287 ng L-1 (megastigma-4,6,8-triene, Qvidja farm). Clear differences in results were seen for samples collected at the SMEAR II station and Qvidja farm, between VOC compositions in gas phase and aerosols, and between the sampling site and height.


Subject(s)
Air Pollutants , Volatile Organic Compounds , Acetone , Air Pollutants/analysis , Gas Chromatography-Mass Spectrometry , Reproducibility of Results , Solid Phase Microextraction , Volatile Organic Compounds/analysis
8.
Anal Chem ; 92(21): 14582-14588, 2020 11 03.
Article in English | MEDLINE | ID: mdl-33081464

ABSTRACT

Cantilever-enhanced photoacoustic spectroscopy coupled with gas chromatography is used to quantitatively analyze a mixture of alcohols in a quasi-online manner. A full identification and quantification of all analytes are achieved based on their spectral fingerprints using a widely tunable continuous-wave laser as a light source. This can be done even in the case of interfering column/septum bleed or simultaneously eluted peaks. The combination of photoacoustic spectroscopy and gas chromatography offers a viable solution for compact and portable instruments in applications that require straightforward analyses with no consumables.

9.
J Sep Sci ; 43(16): 3285-3293, 2020 Aug.
Article in English | MEDLINE | ID: mdl-32506760

ABSTRACT

Today, wide variety of adsorbents have been developed for sample pretreatment to concentrate and separate harmful substances. However, only a few solid phase microextraction Arrow adsorbents are commercially available. In this study, we developed a new solid phase microextraction Arrow coating, in which nanosheets layered double hydroxides and poly(vinylpyrrolidone) were utilized as the extraction phase and poly(vinyl chloride) as the adhesive. This new coating entailed higher extraction capacity for several volatile organic compounds (allyl methyl sulfide, methyl propyl sulfide, 3-pentanone, 2-butanone, and methyl isobutyl ketone) compared to the commercial Carboxen 1000/polydimethylsiloxane coating. Fabrication parameters for the coating were optimized and extraction and desorption conditions were investigated. The validation of the new solid phase microextraction Arrow coating was accomplished using water sample spiked with volatile organic compounds. Under the optimal conditions, the limits of quantification for the five volatile organic compounds by the new solid phase microextraction Arrow coating and developed gas chromatography with mass spectrometry method were in the range of 0.2-4.6 ng/mL. The proposed method was briefly applied for enrichment of volatile organic compounds in sludge.

10.
J Chromatogr A ; 1616: 460825, 2020 Apr 12.
Article in English | MEDLINE | ID: mdl-31924328

ABSTRACT

Several calibration approaches were evaluated for the quantitation of volatile organic compounds in air using miniaturized exhaustive and non-exhaustive sampling techniques, such as in-tube extraction (ITEX) and solid phase microextraction (SPME) Arrow. Eleven compounds, 2-ethyl-hexanol, hexanal, nonanal, toluene, ethyl-benzene, methyl isobutyl ketone, acetophenone, p-cymene, α-pinene, trimethylamine and triethylamine, all them found in the natural air samples, were selected as model analytes. Liquid injection, liquid standard addition to the sorbent bed and gas phase standards provided by an automatic permeation system, were evaluated in the case of ITEX packed with laboratory-made 10% polyacrylonitrile (PAN) material. Two different approaches, based on sampling of gas phase compounds from the permeation system and from sample vial containing gas phase standards, were evaluated for SPME Arrow with two different coatings, commercial divinylbenzene-poly(dimethylsiloxane) (DVB-PDMS) and laboratory-made mesoporous Mobil Composition of Matter No. 41 (MCM-41). In addition, interface model approach was used for the calculation of the real concentration of the target analytes in the sample from the total amount of analytes injected into the GC-MS in the case of SPME Arrow. Similar results were obtained with the different approaches used for the quantitation by ITEX and SPME Arrow. However, the use of gas phase standards with sample matrix similar to the natural samples, allowed the permeation system to provide the most reliable results for the quantitation of the target analytes. For this approach, linearity (expressed as r2 values) ranged between 0.991 and 0.999. The limit of detection ranged from 0.5 µg/m3 (trimethylamine, MCM-41) to 2.2 × 10-4 µg/m3 (methyl isobutyl ketone, MCM-41). In addition, the use of the fully automated permeation system provided good reproducibility values that were between 1.4% (acetophenone, MCM-41) and 7.8% (methyl isobutyl ketone, 10% PAN). The linear ranges were at least 3 order of magnitude for all the studied analytes with the exception of the calibration curve developed for trimethylamine with SPME Arrow (linear ranges between LOQ and 4.9 µg/m3 (DVB-PDMS) and LOQ and 9.8 µg/m3 (MCM-41)).


Subject(s)
Air/analysis , Solid Phase Microextraction/methods , Volatile Organic Compounds/analysis , Calibration , Kinetics , Reproducibility of Results
11.
Mikrochim Acta ; 186(7): 412, 2019 06 11.
Article in English | MEDLINE | ID: mdl-31187285

ABSTRACT

Mesoporous silica-coated solid phase microextraction (SPME) Arrow systems were developed for capturing of low-molecular-weight aliphatic amines (LMWAAs) from complicated sample matrices. Specifically, silicas of type MCM-41, SBA-15 and KIT-6 were chosen as substrates to afford size-exclusion selectivity. They possess ordered multidimensional pore-channel structures and mesopore sizes between 3.8 and 8.2 nm. Their surface acidity was enhanced by grafting them with a layer of titanium hydrogenphosphate (-TP). This enhanced the chemical selectivity for basic LMWAAs. The siliceous coatings increased the extraction of ethylamine, diethylamine (DEA) and triethylamine (TEA) by factors of 18.6-102.5, 4.8-10.8 and 2.6-4.0, respectively, when compared to the commercial SPME Arrow with polydimethylsiloxane/divinylbenzene coating. Among them, the MCM-41 and MCM-41-TP coated SPME Arrows demonstrated exceptional selectivity towards LMWAAs that were quantified by gas chromatography-mass spectrometry (GC-MS). The total peak area ratios of LMWAAs/ten competing compounds were 25.4 and 36.3, respectively. The extraction equilibrium was reached within 20-30 min. The MCM-41 and MCM-41-TP derived SPME Arrows gave very similar results (18.4 ± 2.1-376 ± 12 ng g-1 to DEA and TEA) when applied to urban mushroom samples. SPME Arrow with MCM-41 coatings followed by GC-MS was applied also to the analysis of atmospheric air and urine samples resulting in high selectivity due to the size and mesoporous structure of the functionalized silica, and its chemical interactions with the LMWAAs. Graphical abstract Scheme of synthesis of the MCM-41 silicas, and the preparation of solid phase microextraction Arrow coatings. They were employed for selective capturing of aliphatic amines from complex sample matrices, followed by gas chromatography-mass spectrometry.

12.
Anal Chem ; 91(13): 8507-8515, 2019 07 02.
Article in English | MEDLINE | ID: mdl-31247721

ABSTRACT

Comprehensive and time-dependent information (e.g., chemical composition, concentration) of volatile organic compounds (VOCs) in atmospheric, indoor, and breath air is essential to understand the fundamental science of the atmosphere, air quality, and diseases diagnostic. Here, we introduced a fully automated online dynamic in-tube extraction (ITEX)-gas chromatography/mass spectrometry (GC/MS) method for continuous and quantitative monitoring of VOCs in air. In this approach, modified Cycle Composer software and a PAL autosampler controlled and operated the ITEX preconditioning, internal standard (ISTD) addition, air sampling, and ITEX desorption sequentially to enable full automation. Air flow passed through the ITEX with the help of an external pump, instead of plunger up-down strokes, to allow larger sampling volumes, exhaustive extraction, and consequently lower detection limits. Further, in order to evaluate the ITEX system stability and to develop the corresponding quantitative ITEX method, two laboratory-made permeation systems (for standard VOCs and ISTD) were constructed. The stability and suitability of the developed system was validated with a consecutive 19 day atmospheric air campaign under automation. By using an electrospun polyacrylonitrile nanofibers packed ITEX, selective extraction of some VOCs and durability of over 1500 extraction and desorption cycles were achieved. Especially, the latter step is critically important for on-site long-term application at remote regions. This ITEX method provided 2-3 magnitudes lower quantitation limits than the headspace dynamic ITEX method and other needle trap methods. Our results proved the excellence of the fully automated online dynamic ITEX-GC/MS system for tracking VOCs in the atmospheric air.


Subject(s)
Air Pollutants/analysis , Chemical Fractionation/methods , Gas Chromatography-Mass Spectrometry/methods , Volatile Organic Compounds/analysis , Automation , Limit of Detection
13.
J Chromatogr A ; 1597: 202-208, 2019 Jul 19.
Article in English | MEDLINE | ID: mdl-31030954

ABSTRACT

The applicability of an aerial drone as a carrier for new passive and active miniaturized air sampling systems, including solid phase microextration Arrow (SPME Arrow) and in-tube extraction (ITEX), was studied in this research. Thermal desorption, gas chromatography and mass spectrometry were used for the determination of volatile organic compounds (VOCs) collected by the sampling systems. The direct comparison of the profiles of VOCs, simultaneously sampled in air by SPME Arrow system including four different coatings, allowed the elucidation of their adsorption selectivity. A more complex experimental design, involving 20 samples (10 flights) and non-supervised pattern recognition techniques, was needed for the clarification of the same sampling parameters in the case of five ITEX sorbent materials. In addition, ITEX sampling accessories, such as particle, water and ozone traps, were evaluated by comparing the results obtained for air samples simultaneously collected by two ITEX systems, packed with the same sorbent and furnished or not with sampling accessories. The effect of the aerial drone horizontal displacement (HD) on the sampling efficiency was clear in the case of SPME Arrow. The number of detected compounds and their relative peak area values (RPA) revealed a clear increase (4 and 43%, respectively) in comparison with samples collected without drone HD. However, just minor differences were observed in the case of ITEX (2 compounds and 9% of the ∑RPA). In addition, the system was able to provide almost simultaneous passive (SPME Arrow) and active (ITEX) samplings at different altitudes (5 and 50 m), being a good tool for low cost vertical profiling studies (∑RPA decreased over 35% for the samples collected at 50 m). Finally, the successful simultaneous air sampling by SPME Arrow and ITEX systems in two difficult access places, such as boreal forest and wetlands, was demonstrated, resulting in 21 and 31 detected compounds in forest and wetlands by SPME Arrow, and 27 and 39 compounds by ITEX.


Subject(s)
Air/analysis , Environmental Monitoring/instrumentation , Environmental Monitoring/methods , Volatile Organic Compounds/analysis , Adsorption , Gas Chromatography-Mass Spectrometry , Miniaturization , Solid Phase Microextraction
14.
Anal Chim Acta ; 1024: 93-100, 2018 Sep 18.
Article in English | MEDLINE | ID: mdl-29776551

ABSTRACT

New chemical vapor reaction (CVR) and atomic layer deposition (ALD)-conversion methods were utilized for preparation of metal organic frameworks (MOFs) coatings of solid phase microextraction (SPME) Arrow for the first time. With simple, easy and convenient one-step reaction or conversion, four MOF coatings were made by suspend ALD iron oxide (Fe2O3) film or aluminum oxide (Al2O3) film above terephthalic acid (H2BDC) or trimesic acid (H3BTC) vapor. UIO-66 coating was made by zirconium (Zr)-BDC film in acetic acid vapor. As the first documented instance of all-gas phase synthesis of SPME Arrow coatings, preparation parameters including CVR/conversion time and temperature, acetic acid volume, and metal oxide film/metal-ligand films thickness were investigated. The optimal coatings exhibited crystalline structures, excellent uniformity, satisfactory thickness (2-7.5 µm), and high robustness (>80 times usage). To study the practical usefulness of the coatings for the extraction, several analytes with different chemical properties were tested. The Fe-BDC coating was found to be the most selective and sensitive for the determination of benzene ring contained compounds due to its highly hydrophobic surface and unsaturated metal site. UIO-66 coating was best for small polar, aromatic, and long chain polar compounds owing to its high porosity. The usefulness of new coatings were evaluated for gas chromatography-mass spectrometer (GC-MS) determination of several analytes, present in wastewater samples at three levels of concentration, and satisfactory results were achieved.

15.
Environ Sci Technol ; 51(10): 5602-5610, 2017 May 16.
Article in English | MEDLINE | ID: mdl-28422480

ABSTRACT

Amines are recognized as key compounds in new particle formation (NPF) and secondary organic aerosol (SOA) formation. In addition, ozonolysis of α-pinene contributes substantially to the formation of biogenic SOAs in the atmosphere. In the present study, ozonolysis of α-pinene in the presence of dimethylamine (DMA) was investigated in a flow tube reactor. Effects of amines on SOA formation and chemical composition were examined. Enhancement of NPF and SOA formation was observed in the presence of DMA. Chemical characterization of gas- and particle-phase products by high-resolution mass spectrometric techniques revealed the formation of nitrogen containing compounds. Reactions between ozonolysis reaction products of α-pinene, such as pinonaldehyde or pinonic acid, and DMA were observed. Possible reaction pathways are suggested for the formation of the reaction products. Some of the compounds identified in the laboratory study were also observed in aerosol samples (PM1) collected at the SMEAR II station (Hyytiälä, Finland) suggesting that DMA might affect the ozonolysis of α-pinene in ambient conditions.


Subject(s)
Air Pollutants , Dimethylamines , Monoterpenes/chemistry , Aerosols , Bicyclic Monoterpenes , Finland , Ozone
16.
J Chromatogr A ; 1486: 76-85, 2017 Feb 24.
Article in English | MEDLINE | ID: mdl-27847109

ABSTRACT

In this study, a novel solid phase microextration (SPME) Arrow was prepared for the sampling of volatile low molecular weight alkylamines (trimethylamine (TMA) and triethylamine (TEA)) in wastewater, salmon and mushroom samples before gas chromatographic separation with mass spectrometer as detector. Acidified zeolitic imidazolate framework-8 (A-ZIF-8) was utilized as adsorbent and poly(vinyl chloride) (PVC) as the adhesive. The custom SPME Arrow was fabricated via a physical adhesion: (1) ZIF-8 particles were suspended in a mixture of tetrahydrofuran (THF) and PVC to form a homogeneous suspension, (2) a non-coated stainless steel SPME Arrow was dipped in the ZIF-8/PVC suspension for several times to obtain a uniform and thick coating, (3) the pore size of ZIF-8 was modified by headspace exposure to hydrochloric acid in order to increase the extraction efficiency for amines. The effect of ZIF-8 concentration in PVC solution, dipping cycles and aging temperature on extraction efficiency was investigated. In addition, sampling parameters such as NaCl concentration, sample volume, extraction time, potassium hydroxide concentration, desorption temperature and desorption time were optimized. The Arrow-to-Arrow reproducibilities (RSDs) for five ZIF-8 coated Arrows were 15.6% and 13.3% for TMA and TEA, respectively. The extraction with A-ZIF-8/PVC Arrow was highly reproducible for at least 130 cycles without noticeable decrease of performance (RSD<12.5%). Headspace SPME of 7.5mL sample solution with the fabricated ZIF-8 coated Arrow achieved linear ranges of 1-200ngmL-1 for both TMA and TEA. The limit of quantitation (LOQ) was 1ngmL-1 for both TMA and TEA. The method was successfully applied to the determination of TMA and TEA in wastewater, salmon and mushroom samples giving satisfactory selectivity towards the studied amines.


Subject(s)
Amines/analysis , Amines/chemistry , Food Analysis/methods , Gas Chromatography-Mass Spectrometry , Imidazoles/chemistry , Solid Phase Microextraction/methods , Wastewater/chemistry , Zeolites/chemistry , Agaricales/chemistry , Animals , Ethylamines/analysis , Ethylamines/chemistry , Methylamines/analysis , Methylamines/chemistry , Molecular Weight , Polyvinyl Chloride/chemistry , Salmon , Seafood , Sodium Chloride/chemistry , Solid Phase Microextraction/instrumentation , Stainless Steel/chemistry , Temperature
17.
Environ Sci Technol ; 50(9): 4693-700, 2016 05 03.
Article in English | MEDLINE | ID: mdl-27035788

ABSTRACT

Pinonaldehyde, which is among the most abundant oxidation products of α-pinene, and dimethylamine were selected to study the formation of N-containing low volatile compounds from aldehyde-amine reactions in the atmosphere. Gas phase reactions took place in a Tedlar bag, which was connected to a mass spectrometer ionization source via a short deactivated fused silica column. In addition to on-line analysis, abundance of gaseous precursors and reaction products were monitored off-line. Condensable products were extracted from the bag's walls with a suitable solvent and analyzed by gas chromatography coupled to chemical ionization high-resolution quadrupole time-of-flight mass spectrometry and by ultra-high-performance liquid chromatography coupled to electrospray ionization Orbitrap mass spectrometry. The reactions carried out resulted in several mid-low vapor pressure nitrogen-containing compounds that are potentially important for the formation of secondary organic aerosols in the atmosphere. Further, the presence of brown carbon, confirmed by liquid chromatography-UV-vis-mass spectrometry, was observed. Some of the compounds identified in the laboratory study were also observed in aerosol samples collected at SMEAR II station (Hyytiälä, Finland) in August 2015 suggesting the importance of aldehyde-amine reactions for the aerosol formation and growth.


Subject(s)
Atmosphere/chemistry , Nitrogen , Aerosols , Dimethylamines , Spectrometry, Mass, Electrospray Ionization
18.
J Chromatogr A ; 1426: 56-63, 2015 Dec 24.
Article in English | MEDLINE | ID: mdl-26643724

ABSTRACT

A new method is introduced for the sampling of volatile low molecular weight alkylamines in ambient air and wastewater by utilizing a novel SPME Arrow system, which contains a larger volume of sorbent compared to a standard SPME fiber. Parameters affecting the extraction, such as coating material, need for preconcentration, sample volume, pH, stirring rate, salt addition, extraction time and temperature were carefully optimized. In addition, analysis conditions, including desorption temperature and time as well as gas chromatographic parameters, were optimized. Compared to conventional SPME fiber, the SPME Arrow had better robustness and sensitivity. Average intermediate reproducibility of the method expressed as relative standard deviation was 12% for dimethylamine and 14% for trimethylamine, and their limit of quantification 10µg/L and 0.13µg/L respectively. Working range was from limits of quantification to 500µg/L for dimethylamine and to 130µg/L for trimethylamine. Several alkylamines were qualitatively analyzed in real samples, while target compounds dimethyl- and trimethylamines were quantified. The concentrations in influent and effluent wastewater samples were almost the same (∼80µg/L for dimethylamine, 120µg/L for trimethylamine) meaning that amines pass the water purification process unchanged or they are produced at the same rate as they are removed. For the air samples, preconcentration with phosphoric acid coated denuder was required and the concentration of trimethylamine was found to be around 1ng/m(3). The developed method was compared with optimized method based on conventional SPME and advantages and disadvantages of both approaches are discussed.


Subject(s)
Amines/analysis , Atmosphere/chemistry , Solid Phase Microextraction/methods , Wastewater/chemistry , Chromatography, Gas , Reproducibility of Results , Sodium Chloride/chemistry , Temperature
19.
Rapid Commun Mass Spectrom ; 29(13): 1233-41, 2015 Jul 15.
Article in English | MEDLINE | ID: mdl-26395607

ABSTRACT

RATIONALE: On-line chemical characterization methods of atmospheric aerosols are essential to increase our understanding of physicochemical processes in the atmosphere, and to study biosphere-atmosphere interactions. Several techniques, including aerosol mass spectrometry, are nowadays available, but they all suffer from some disadvantages. In this research, desorption atmospheric pressure photoionization high-resolution (Orbitrap) mass spectrometry (DAPPI-HRMS) is introduced as a complementary technique for the fast analysis of aerosol chemical composition without the need for sample preparation. METHODS: Atmospheric aerosols from city air were collected on a filter, desorbed in a DAPPI source with a hot stream of toluene and nitrogen, and ionized using a vacuum ultraviolet lamp at atmospheric pressure. To study the applicability of the technique for ambient aerosol analysis, several samples were collected onto filters and analyzed, with the focus being on selected organic acids. To compare the DAPPI-HRMS data with results obtained by an established method, each filter sample was divided into two equal parts, and the second half of the filter was extracted and analyzed by liquid chromatography/mass spectrometry (LC/MS). RESULTS: The DAPPI results agreed with the measured aerosol particle number. In addition to the targeted acids, the LC/MS and DAPPI-HRMS methods were found to detect different compounds, thus providing complementary information about the aerosol samples. CONCLUSIONS: DAPPI-HRMS showed several important oxidation products of terpenes, and numerous compounds were tentatively identified. Thanks to the soft ionization, high mass resolution, fast analysis, simplicity and on-line applicability, the proposed methodology has high potential in the field of atmospheric research.


Subject(s)
Aerosols/analysis , Mass Spectrometry/methods , Aerosols/chemistry , Atmosphere , Caprylates/analysis , Caprylates/chemistry , Carboxylic Acids/analysis , Carboxylic Acids/chemistry , Chromatography, Liquid/methods , Mass Spectrometry/instrumentation , Oxidation-Reduction , Terpenes/analysis , Terpenes/chemistry
20.
J Chromatogr A ; 1376: 46-52, 2015 Jan 09.
Article in English | MEDLINE | ID: mdl-25542706

ABSTRACT

Alkylamines play an important role in atmospheric chemistry and are of concern for human health. Determining them from the vapor phase is challenging owing to their high polarity and volatility, water solubility, low concentrations, and poor chromatographic properties. We propose on-fiber derivatization solid-phase microextraction (SPME) to increase sensitivity and selectivity for the determination of alkylamines in air samples. SPME fibers coated in head-space with 2,3,4,5,6-pentafluorobenzyl chloroformate (PFBCF, 10min) or 9-fluorenylmethoxycarbonyl (FMOC) chloride (5min) were exposed to the sample for 5-120min, after which the derivatized alkylamines were thermally desorbed in the GC injection port and analyzed by GC-MS. The specific focus of the research was dimethylamine (DMA) but, as well as secondary amines, both coating agents readily react with primary and tertiary amines and with ammonia at ambient temperatures. The fiber coating procedures, sampling times, and analytical conditions were optimized, and methods were tested with natural samples. PFBCF was more selective and almost an order of magnitude more sensitive than FMOC chloride. Both reagents are applicable, however, depending on the requirements. With scan mode and use of molecular ion for quantification, the limit of quantification for DMA was 0.17µgL(-1) when derivatized with PFBCF and 3.4µgL(-1) when derivatized with FMOC chloride. When selected ion monitoring was used with the most abundant ion, the limit of quantification for DMA was 2.8ngL(-1). Intermediate reproducibility expressed as relative standard deviation was around 30% with PFBCF and less than 20% with FMOC chloride. Fibers coated with PFBCF could be used at least up to 24h when stored at 4°C and for 5 to 7h when stored at room temperature. After sampling/derivatization, storage time before analysis should not exceed 48h at 4°C or 24h at room temperature. At maximum, the PFBCF-coated fiber can be used in 100 coating/sampling/analysis cycles.


Subject(s)
Amines/analysis , Fluorenes/chemistry , Formates/chemistry , Gas Chromatography-Mass Spectrometry/methods , Humans , Indicators and Reagents , Reproducibility of Results , Solid Phase Microextraction/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...