Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
J Breast Imaging ; 3(1): 44-56, 2021.
Article in English | MEDLINE | ID: mdl-33543122

ABSTRACT

OBJECTIVE: The A6702 multisite trial confirmed that apparent diffusion coefficient (ADC) measures can improve breast MRI accuracy and reduce unnecessary biopsies, but also found that technical issues rendered many lesions non-evaluable on diffusion-weighted imaging (DWI). This secondary analysis investigated factors affecting lesion evaluability and impact on diagnostic performance. METHODS: The A6702 protocol was IRB-approved at 10 institutions; participants provided informed consent. In total, 103 women with 142 MRI-detected breast lesions (BI-RADS assessment category 3, 4, or 5) completed the study. DWI was acquired at 1.5T and 3T using a four b-value, echo-planar imaging sequence. Scans were reviewed for multiple quality factors (artifacts, signal-to-noise, misregistration, and fat suppression); lesions were considered non-evaluable if there was low confidence in ADC measurement. Associations of lesion evaluability with imaging and lesion characteristics were determined. Areas under the receiver operating characteristic curves (AUCs) were compared using bootstrapping. RESULTS: Thirty percent (42/142) of lesions were non-evaluable on DWI; 23% (32/142) with image quality issues, 7% (10/142) with conspicuity and/or localization issues. Misregistration was the only factor associated with non-evaluability (P = 0.001). Smaller (≤10 mm) lesions were more commonly non-evaluable than larger lesions (p <0.03), though not significant after multiplicity correction. The AUC for differentiating benign and malignant lesions increased after excluding non-evaluable lesions, from 0.61 (95% CI: 0.50-0.71) to 0.75 (95% CI: 0.65-0.84). CONCLUSION: Image quality remains a technical challenge in breast DWI, particularly for smaller lesions. Protocol optimization and advanced acquisition and post-processing techniques would help to improve clinical utility.

2.
Radiology ; 298(1): 60-70, 2021 01.
Article in English | MEDLINE | ID: mdl-33201788

ABSTRACT

Background The Eastern Cooperative Oncology Group and American College of Radiology Imaging Network Cancer Research Group A6702 multicenter trial helped confirm the potential of diffusion-weighted MRI for improving differential diagnosis of suspicious breast abnormalities and reducing unnecessary biopsies. A prespecified secondary objective was to explore the relative value of different approaches for quantitative assessment of lesions at diffusion-weighted MRI. Purpose To determine whether alternate calculations of apparent diffusion coefficient (ADC) can help further improve diagnostic performance versus mean ADC values alone for analysis of suspicious breast lesions at MRI. Materials and Methods This prospective trial (ClinicalTrials.gov identifier: NCT02022579) enrolled consecutive women (from March 2014 to April 2015) with a Breast Imaging Reporting and Data System category of 3, 4, or 5 at breast MRI. All study participants underwent standardized diffusion-weighted MRI (b = 0, 100, 600, and 800 sec/mm2). Centralized ADC measures were performed, including manually drawn whole-lesion and hotspot regions of interest, histogram metrics, normalized ADC, and variable b-value combinations. Diagnostic performance was estimated by using the area under the receiver operating characteristic curve (AUC). Reduction in biopsy rate (maintaining 100% sensitivity) was estimated according to thresholds for each ADC metric. Results Among 107 enrolled women, 81 lesions with outcomes (28 malignant and 53 benign) in 67 women (median age, 49 years; interquartile range, 41-60 years) were analyzed. Among ADC metrics tested, none improved diagnostic performance versus standard mean ADC (AUC, 0.59-0.79 vs AUC, 0.75; P = .02-.84), and maximum ADC had worse performance (AUC, 0.52; P < .001). The 25th-percentile ADC metric provided the best performance (AUC, 0.79; 95% CI: 0.70, 0.88), and a threshold using median ADC provided the greatest reduction in biopsy rate of 23.9% (95% CI: 14.8, 32.9; 16 of 67 BI-RADS category 4 and 5 lesions). Nonzero minimum b value (100, 600, and 800 sec/mm2) did not improve the AUC (0.74; P = .28), and several combinations of two b values (0 and 600, 100 and 600, 0 and 800, and 100 and 800 sec/mm2; AUC, 0.73-0.76) provided results similar to those seen with calculations of four b values (AUC, 0.75; P = .17-.87). Conclusion Mean apparent diffusion coefficient calculated with a two-b-value acquisition is a simple and sufficient diffusion-weighted MRI metric to augment diagnostic performance of breast MRI compared with more complex approaches to apparent diffusion coefficient measurement. © RSNA, 2020 Online supplemental material is available for this article.


Subject(s)
Breast Neoplasms/diagnostic imaging , Diffusion Magnetic Resonance Imaging/methods , Adult , Aged , Breast/diagnostic imaging , Diagnosis, Differential , Female , Humans , Middle Aged , Prospective Studies , Reproducibility of Results , Sensitivity and Specificity , Societies, Medical , Young Adult
3.
Clin Cancer Res ; 25(6): 1756-1765, 2019 03 15.
Article in English | MEDLINE | ID: mdl-30647080

ABSTRACT

PURPOSE: Conventional breast MRI is highly sensitive for cancer detection but prompts some false positives. We performed a prospective, multicenter study to determine whether apparent diffusion coefficients (ADCs) from diffusion-weighted imaging (DWI) can decrease MRI false positives.Experimental Design: A total of 107 women with MRI-detected BI-RADS 3, 4, or 5 lesions were enrolled from March 2014 to April 2015. ADCs were measured both centrally and at participating sites. ROC analysis was employed to assess diagnostic performance of centrally measured ADCs and identify optimal ADC thresholds to reduce unnecessary biopsies. Lesion reference standard was based on either definitive biopsy result or at least 337 days of follow-up after the initial MRI procedure. RESULTS: Of 107 women enrolled, 67 patients (median age 49, range 24-75 years) with 81 lesions with confirmed reference standard (28 malignant, 53 benign) and evaluable DWI were analyzed. Sixty-seven of 81 lesions were BI-RADS 4 (n = 63) or 5 (n = 4) and recommended for biopsy. Malignancies exhibited lower mean in centrally measured ADCs (mm2/s) than benign lesions [1.21 × 10-3 vs.1.47 × 10-3; P < 0.0001; area under ROC curve = 0.75; 95% confidence interval (CI) 0.65-0.84]. In centralized analysis, application of an ADC threshold (1.53 × 10-3 mm2/s) lowered the biopsy rate by 20.9% (14/67; 95% CI, 11.2%-31.2%) without affecting sensitivity. Application of a more conservative threshold (1.68 × 10-3 mm2/s) to site-measured ADCs reduced the biopsy rate by 26.2% (16/61) but missed three cancers. CONCLUSIONS: DWI can reclassify a substantial fraction of suspicious breast MRI findings as benign and thereby decrease unnecessary biopsies. ADC thresholds identified in this trial should be validated in future phase III studies.


Subject(s)
Breast Neoplasms/diagnosis , Breast/diagnostic imaging , Diffusion Magnetic Resonance Imaging/methods , Image Interpretation, Computer-Assisted , Adult , Aged , Biopsy/adverse effects , Breast/pathology , Breast Neoplasms/pathology , Diagnosis, Differential , False Positive Reactions , Female , Humans , Middle Aged , Prospective Studies , ROC Curve , Reference Values , Sensitivity and Specificity , Young Adult
4.
Clin Imaging ; 47: 25-29, 2018.
Article in English | MEDLINE | ID: mdl-28823603

ABSTRACT

Congenital uterine anomalies have a profound impact on reproductive outcomes. The unicornuate uterus accounts for approximately 20% of all congenital uterine anomalies. Unicornuate uterine anomalies with non-communicating rudimentary horns are at risk of developing ectopic pregnancy in the rudimentary horn. Given increased risked of uterine rupture, rudimentary horn pregnancies pose significant maternal health risks. Understanding the sonographic appearance of early pregnancy within the rudimentary horn of the unicornuate uterine configuration is imperative for appropriate and timely clinical management. We present two cases of pregnancy in the rudimentary horn of a unicornuate uterus diagnosed sonographically in the first trimester.


Subject(s)
Pregnancy, Cornual/diagnosis , Pregnancy, Ectopic/diagnosis , Ultrasonography/methods , Urogenital Abnormalities/complications , Uterus/abnormalities , Adult , Female , Humans , Pregnancy , Pregnancy Trimester, First , Pregnancy, Cornual/diagnostic imaging , Pregnancy, Cornual/etiology , Pregnancy, Ectopic/diagnostic imaging , Pregnancy, Ectopic/etiology
5.
Ultrasound Q ; 28(4): 243-9, 2012 Dec.
Article in English | MEDLINE | ID: mdl-23149508

ABSTRACT

Transperineal sonography (TPS) affords dynamic evaluation of suburethral slings using tensionless vaginal tape and mesh implants used to treat complications associated with surgical procedures of the pelvic floor. This review describes and illustrates the TPS findings in postoperative complications such as recurrent prolapse, cystocele, enterocele, and rectocele. The potential use of live 3-dimensional TPS to delineate the dynamics aspects of pelvic floor disorder is also mentioned.


Subject(s)
Imaging, Three-Dimensional/methods , Pelvic Floor Disorders/diagnostic imaging , Pelvic Floor Disorders/surgery , Perineum/diagnostic imaging , Surgical Mesh , Female , Humans , Pelvic Floor/diagnostic imaging , Pelvic Floor/surgery , Postoperative Complications/diagnostic imaging , Postoperative Complications/surgery , Prolapse , Rectocele/diagnostic imaging , Rectocele/surgery , Recurrence , Suburethral Slings , Treatment Outcome , Ultrasonography , Uterine Prolapse/diagnostic imaging , Uterine Prolapse/surgery
7.
Vasc Endovascular Surg ; 42(5): 489-93, 2008.
Article in English | MEDLINE | ID: mdl-19000984

ABSTRACT

The inferior epigastric artery represents a potentially overlooked source of pelvic arterial hemorrhage. The authors describe 3 patients with massive inferior epigastric artery bleeding following cesarean section, paracentesis, and blunt trauma that were successfully treated with transarterial embolization. The inferior epigastric artery should be considered as a possible source of arterial hemorrhage if arteriography of internal iliac artery branches does not yield a bleeding source.


Subject(s)
Embolization, Therapeutic , Epigastric Arteries/injuries , Hemorrhage/therapy , Adult , Aged , Cesarean Section/adverse effects , Epigastric Arteries/diagnostic imaging , Female , Hemorrhage/diagnostic imaging , Hemorrhage/etiology , Humans , Male , Paracentesis/adverse effects , Pregnancy , Tomography, X-Ray Computed , Treatment Outcome , Wounds, Nonpenetrating/complications
SELECTION OF CITATIONS
SEARCH DETAIL
...