1.
Clin Ophthalmol ; 6: 1135-48, 2012.
Article in English | MEDLINE | ID: mdl-22888212

ABSTRACT

BACKGROUND: This analysis compared outcomes for same-day (under a no-move, no-wait policy) versus delayed vitrectomy for intravitreal crystalline retained lens fragments after surgery for age-related cataract. METHODS: This was a retrospective, nonrandomized treatment comparison cohort study with a consecutive series of 35 eyes (23 same-day, 12 delayed) receiving both cataract surgery and vitrectomy at the Mayo Clinic Florida between 1999 and 2010. Outcome measures included visual acuity (VA), glaucoma progression, visual utility, and complications. Several techniques (bootstrapping, robust confidence intervals, jackknifing, and a homogeneous sample) were used to reduce selection bias and increase confidence in our small sample's results. RESULTS: No significant baseline treatment group differences. Mean previtrectomy delay (12 eyes) was 40.9 days (median 29.5, range 1-166). Mean postvitrectomy follow-up (35 eyes) was 47.5 months (median 40.5, range 3.1-123.5). Same-day patients had significantly better final VA (adjusted for age [t = -2.14, P = 0.040] and precataract surgery VA [t = -2.98, P = 0.006]); a higher rate of good final VA (≥20/40), 78.3% (18/23) versus 58.3% (7/12); a lower rate of bad final VA (≤20/200), 4.3% (1/23) versus 25.0% (3/12); and fewer final retinal conditions, 4.3% (1/23) versus 50.0% (6/12). Same-day patients also had marginally significant better mean final VA in the operated eye (20/40 versus 20/90, Z = 1.51, P = 0.130) despite poorer initial VA (20/98 versus 20/75) and higher age (3+ years), better final visual utility, and longer survival times for better VA. Among patients with preexisting glaucoma, same-day patients experienced significantly less differential (operated versus nonoperated eye) glaucoma progression. CONCLUSION: Results favored same-day patients, who experienced better final VA and visual utility, less differential glaucoma progression, and fewer complications. Results need confirmation with larger samples.

2.
Infect Control Hosp Epidemiol ; 27(3): 294-8, 2006 Mar.
Article in English | MEDLINE | ID: mdl-16532418

ABSTRACT

BACKGROUND: Toxic anterior segment syndrome (TASS), a complication of cataract surgery, is a sterile inflammation of the anterior chamber of the eye. An outbreak of TASS was recognized at an outpatient surgical center and its affiliated hospital in December 2002. METHODS: Medical records of patients who underwent cataract surgery during the outbreak were reviewed, and surgical team members who participated in the operations were interviewed. Potential causes of TASS were identified and eliminated. Feedwater from autoclave steam generators and steam condensates were analyzed by use of spectroscopy and ion chromatography. RESULTS: During the outbreak, 8 (38%) of 21 cataract operations were complicated by TASS, compared with 2 (0.07%) of 2,713 operations performed from January 1996 through November 2002. Results of an initial investigation suggested that cataract surgical equipment may have been contaminated by suboptimal equipment reprocessing or as a result of personnel changes. The frequency of TASS decreased (1 of 44 cataract operations) after reassignment of personnel and revision of equipment reprocessing procedures. Further investigation identified the presence of impurities (eg, sulfates, copper, zinc, nickel, and silica) in autoclave steam moisture, which was attributed to improper maintenance of the autoclave steam generator in the outpatient surgical center. When impurities in autoclave steam moisture were eliminated, no cases of TASS were observed after more than 1,000 cataract operations. CONCLUSION: Suboptimal reprocessing of cataract surgical equipment may evolve over time in busy, multidisciplinary surgical centers. Clinically significant contamination of surgical equipment may result from inappropriate maintenance of steam sterilization systems. Standardization of protocols for reprocessing of cataract surgical equipment may prevent outbreaks of TASS and may be of assistance during outbreak investigations.


Subject(s)
Cataract Extraction/statistics & numerical data , Disease Outbreaks , Equipment Contamination , Inflammation/epidemiology , Water Pollution , Anterior Eye Segment , Humans , Inflammation/etiology , Inflammation/pathology , Medical Records