Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
J Clin Rheumatol ; 28(1): e44-e48, 2022 Jan 01.
Article in English | MEDLINE | ID: mdl-32956155

ABSTRACT

OBJECTIVE: Rapidly destructive coxopathy (RDC) is a rare condition characterized by rapid joint space narrowing; however, its pathology remains unclear. This study aimed to clarify the association of laboratory biomarkers with the radiological progression of RDC. METHODS: We examined 34 female and 4 male patients with RDC between October 2010 and April 2018. Patients were divided into 3 groups according to the progressive radiographic staging of RDC. Group 1 patients had progressive obliteration of the joint space without subchondral destruction (n = 11), group 2 had progressed subchondral destruction (n = 18), and group 3 had cessation of bone destruction observed for more than 6 months (n = 9). Clinical evaluation results were assessed using the Japanese Orthopedic Association hip score. Blood test results, including serum matrix metalloproteinase-3 (MMP-3), and C-reactive protein (CRP), were also evaluated. RESULTS: There were no significant differences in patient background or Japanese Orthopedic Association hip scores among the groups. However, there were significant differences in MMP-3 levels among groups, with MMP-3 levels in group 2 being significantly higher than those in group 3 (group 2, 118.4 ± 81.2 ng/mL; group 3, 42.5 ± 15.1 ng/mL, p < 0.001). The CRP levels in group 2 were also significantly higher than those in group 3 (group 2, 0.77 ± 0.92 mg/dL; group 3, 0.13 ± 0.07 mg/dL, p = 0.019), but elevated CRP levels in group 2 decreased back to the reference range. CONCLUSIONS: Matrix metalloproteinase-3 and CRP are the biomarkers of RDC progression but not of its occurrence. Severe inflammatory response may be associated with bone destruction in RDC.


Subject(s)
C-Reactive Protein , Joint Diseases , Matrix Metalloproteinase 3/blood , Biomarkers/blood , C-Reactive Protein/analysis , Female , Humans , Male , Radiography
2.
J Arthroplasty ; 36(6): 2055-2061, 2021 06.
Article in English | MEDLINE | ID: mdl-33637384

ABSTRACT

BACKGROUND: This study aimed to compare the clinical and radiographic outcomes of using two different oversized rasps in total hip arthroplasty (THA) with a composite beam cemented stem (DCM-J). METHODS: A consecutive series of 105 hips underwent hybrid THA using the DCM-J stem between 2006 and 2010. Among the patients with a minimum 10-year follow-up, a 1.5-mm oversized rasp was used in 38 hips (group S), whereas a 0.5-mm oversized rasp was used in 36 hips (group M). The Japanese Orthopedic Association hip score and radiographic findings were evaluated, including cement mantle thickness, stress shielding, and cortical hypertrophy. RESULTS: The Japanese Orthopedic Association hip score was significantly improved postoperatively with 100% of the implant survival rate in both groups when septic loosening was excluded. Radiographic assessment performed immediately postoperatively revealed that the cement mantle thickness was significantly larger in group M than group S in Gruen zone 1 but did not differ between groups in zones 2-7. Stress shielding was significantly more frequent in group M than group S at 2 years (P = .011), 5 years (P = .012), and ≥10 years postoperatively (P = .038). Cortical hypertrophy appeared in a time-dependent manner; however, the prevalence did not significantly differ between groups at final follow-up at a mean of 11.7 years (range 10-14 years) postoperatively. CONCLUSIONS: The DCM-J stem achieved good clinical results in both groups. Stress shielding was significantly more frequent in THA using the 0.5-mm rasp than the 1.5-mm rasp, indicating that sufficient cement mantle room should be prepared for the cemented stem.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Bone Cements , Follow-Up Studies , Hip Joint , Humans , Prosthesis Design , Prosthesis Failure
3.
J Bone Miner Metab ; 38(5): 678-686, 2020 Sep.
Article in English | MEDLINE | ID: mdl-32236684

ABSTRACT

The aim of this study was to investigate the effect of bisphosphonates on preventing osteoporotic hip fracture in patients with or without prior major osteoporotic fracture. Randomized controlled trials (RCTs) and observational studies (OSs) based on electronic health records were used to assess bisphosphonate efficacy and were searched using PubMed, Scopus, and the Cochrane Library databases. Eight RCT studies and 14 OSs were extracted from the studies and quantitatively combined by random-effects meta-analysis. The odds ratio (OR) for all hip fractures in RCTs of 0.66, with a 95% confidence interval (CI) of 0.55-0.79, was lower than that in the OSs (OR 0.83; CI 0.74-0.94). The OR in patients with prior fracture was significantly reduced by bisphosphonates in both RCTs and OSs. Conversely, significant fracture reduction was not apparent in patients without prior fracture. A moderate relationship between prior major fracture rates and OR in hip fractures was defined. In patients with an average age of over 80 years, similar results were confirmed. In this meta-analysis, the efficacy of bisphosphonates was significant in patients with prior major fracture, recommending to prescribe for such patients. Their effect in patients without prior fracture, in contrast, remains unclear.


Subject(s)
Diphosphonates/therapeutic use , Hip Fractures/drug therapy , Hip Fractures/prevention & control , Aged, 80 and over , Bone Density Conservation Agents/therapeutic use , Humans , Male , Observational Studies as Topic , Randomized Controlled Trials as Topic , Treatment Outcome
4.
Orthopedics ; 41(6): e876-e879, 2018 Nov 01.
Article in English | MEDLINE | ID: mdl-30125037

ABSTRACT

The authors report a case of immunoglobulin G4-related disease (IgG4-RD) of the hip. A 60-year-old man diagnosed with osteoarthritis of the right hip was referred to the authors' outpatient clinic for surgical intervention. Laboratory test results revealed elevated C-reactive protein and serum IgG levels. A subsequent laboratory test revealed an IgG4 level of 318 mg/dL. Magnetic resonance imaging revealed an abnormal mass in the right hip joint. The authors suspected IgG4-RD of the hip. The mass was resected during total hip arthroplasty. Immunohistochemical analysis for IgG revealed positive staining of many plasma cells. Most of the IgG-positive plasma cells were positive for IgG4, and the ratio of IgG4/IgG-positive cells was 51%. This case met all criteria for IgG4-RD; thus, the authors made a definitive diagnosis of IgG4-RD of the hip. The C-reactive protein level decreased to a negative value, and the IgG level decreased to a normal range at 3 weeks postoperatively. The IgG4 level gradually decreased to 152 mg/dL at 5 months postoperatively. This is the first reported case of IgG4-RD of the hip joint. [Orthopedics. 2018; 41(6):e876-e879.].


Subject(s)
Hip Joint , Immunoglobulin G4-Related Disease/diagnostic imaging , Immunoglobulin G4-Related Disease/pathology , Joint Diseases/diagnostic imaging , Joint Diseases/pathology , C-Reactive Protein/metabolism , Humans , Immunoglobulin G/blood , Immunoglobulin G4-Related Disease/blood , Joint Diseases/blood , Magnetic Resonance Imaging , Male , Middle Aged
5.
Orthopedics ; 40(6): e1103-e1106, 2017 Nov 01.
Article in English | MEDLINE | ID: mdl-28662252

ABSTRACT

A 76-year-old woman who underwent bilateral metal-on-metal total hip arthroplasty fell 3 years after this procedure and subsequently incurred continuous pain in her buttock. Plain radiographs showed no fracture and no loosening of the hip prosthesis. Magnetic resonance imaging revealed an abnormal, large, thick-walled mass with heterogeneous signal intensity at the right buttock. The prerevision diagnosis was adverse reaction to metal debris. The mass was surgically resected, and the metal femoral head was replaced by a dual-mobility prosthesis. The intraoperative and histological analyses indicated an expanding hematoma. Cobalt ion concentrations of whole blood and effusion around the hematoma-1.9 µg/L and 1.3 µg/L, respectively-were not indicative of adverse reaction to metal debris. Transcatheter arterial embolization was performed 2 days postoperatively. The hematoma was reduced and was not present after 9 months. The diagnosis of a periprosthetic soft tissue mass after metal-on-metal total hip arthroplasty should be carefully reached with magnetic resonance imaging and assessment of blood metal ion concentrations. Expanding hematoma should be considered a potential diagnosis if metal ion concentrations are not increasing and magnetic resonance imaging shows a periprosthetic mass with a heterogeneous lesion. Embolization is useful for the management of an expanding hematoma. [Orthopedics. 2017; 40(6):e1103-e1106.].


Subject(s)
Arthroplasty, Replacement, Hip/adverse effects , Arthroplasty, Replacement, Hip/instrumentation , Hematoma/etiology , Hip Prosthesis , Metal-on-Metal Joint Prostheses , Postoperative Complications/diagnostic imaging , Accidental Falls , Aged , Arthroplasty, Replacement, Hip/methods , Buttocks/diagnostic imaging , Chromium/blood , Cobalt/blood , Female , Hematoma/diagnostic imaging , Humans , Magnetic Resonance Imaging
6.
Orthopedics ; 40(1): e117-e123, 2017 Jan 01.
Article in English | MEDLINE | ID: mdl-27755641

ABSTRACT

Idiopathic osteonecrosis of the femoral head (ONFH) can be correctly diagnosed in accordance with the established criteria. However, some general orthopedic physicians have misdiagnosed patients as having ONFH. The goal of this study was to clarify the radiologic and clinical features of misdiagnosed patients. This study included 50 patients who were referred to the authors' hospital by general physicians with a diagnosis of ONFH. The correct diagnosis was made based on the Japanese Investigation Committee diagnostic criteria for ONFH. Demographic data were compared between patients with and without ONFH. Of the 50 patients, 24 were diagnosed with other diseases: 10 with osteoarthritis, 7 with transient osteoporosis of the femoral head, 4 with rapidly destructive coxopathy, and 3 with subchondral insufficiency fracture. Seventeen patients who did not have ONFH had magnetic resonance imaging findings that showed a bone marrow edema pattern at the femoral head. The mean age of 62.9 years among patients without ONFH was significantly higher than that of 45.2 years among patients with ONFH. There were 18 female patients in the non-ONFH group and 5 female patients in the ONFH group. Bilateral disease was found in 1 patient in the non-ONFH group and 17 patients in the ONFH group. No patients in the non-ONFH group had a history of systemic steroid administration compared with 11 patients in the ONFH group. Clinical features associated with the non-ONFH group were female sex, older age, unilateral disease, and no history of systemic steroid administration. For patients with these features, the diagnosis of ONFH should be made carefully. [Orthopedics. 2017; 40(1):e117-e123.].


Subject(s)
Diagnostic Errors , Femur Head Necrosis/diagnostic imaging , Fractures, Stress/diagnostic imaging , Osteoarthritis/diagnostic imaging , Osteoporosis/diagnostic imaging , Adult , Aged , Aged, 80 and over , Female , Humans , Magnetic Resonance Imaging , Male , Middle Aged , Steroids/therapeutic use , Young Adult
7.
Spine (Phila Pa 1976) ; 33(25): 2754-8, 2008 Dec 01.
Article in English | MEDLINE | ID: mdl-19050581

ABSTRACT

STUDY DESIGN: A retrospective case-control study. OBJECTIVE: To clarify associations between both lamina horizontalization and facet tropism and adjacent segment degeneration (ASD). SUMMARY OF BACKGROUND DATA: We have previously reported coexistence of lamina horizontalization and facet tropism adjacent to the cranial fusion segment as risk factors for ASD. METHODS: Subjects comprised 20 patients who underwent additional surgery for ASD after L4/5 posterior lumbar interbody fusion (PLIF) for L4 degenerative spondylolisthesis. Patients who underwent additional surgery for ASD (ASD group) were divided into 2 groups according to the duration until additional surgery: early group (n = 13), additional surgery < or =3 years after primary surgery; and late group (n = 7), additional surgery >3 years after primary surgery. As a control group, 20 age- and sex-matched patients who underwent L4/5 PLIF and could be followed for > or =5 years without ASD were selected. Lamina inclination angle at L3 and facet tropism at L3/4 in each group were measured 3 times by 3 individuals blinded to clinical results. Associations between clinical results and these risk factors and influences of these factors for periods up to the occurrence of ASD were investigated. RESULTS: All ASD was observed in the cranial adjacent segment and the most common condition at additional surgery was spondylolisthesis (n = 15, 75%). Lamina inclination angle was significantly higher in the ASD group than in the control group. ASD was observed in 86% of patients with lamina inclination >130 degrees . In addition, facet tropism was more significant in the early group than in the late and control groups. ASD was observed < or =3 years after primary surgery in all patients with both lamina inclination >130 degrees and facet tropism >10 degrees . CONCLUSION: Preexisting lamina horizontalization at the cranial fusion segment seems to affect ASD, and coexistence of lamina horizontalization and facet tropism seems to accelerate ASD after PLIF.


Subject(s)
Lumbar Vertebrae/surgery , Spinal Diseases/physiopathology , Spinal Diseases/surgery , Spinal Fusion/adverse effects , Tropism/physiology , Zygapophyseal Joint/physiopathology , Adult , Aged , Case-Control Studies , Female , Humans , Lumbar Vertebrae/physiopathology , Male , Middle Aged , Retrospective Studies , Risk Factors , Spinal Diseases/etiology , Spinal Fusion/methods , Spondylolisthesis/physiopathology , Spondylolisthesis/surgery , Zygapophyseal Joint/surgery
SELECTION OF CITATIONS
SEARCH DETAIL
...