Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
BMJ Open Ophthalmol ; 8(1)2023 11 24.
Article in English | MEDLINE | ID: mdl-38007230

ABSTRACT

OBJECTIVE: To investigate repeatability of refractive state using a smartphone-based assessment tool, the Near Eye Tool for Refractive Assessment (NETRA). METHODS AND ANALYSIS: This study included 279 participants, predominantly female (66.7%) of African descent (49.1%). The age range was 9-63 years with mean age (s) 22.6 (8.9) years. Two consecutive measurements per eye with the NETRA were measured for both eyes of all participants. However, analyses for the right eyes only are included here. Multivariate statistical analysis included stereo-pair comets and scatterplots with 95% surfaces of constant probability density. Correlation coefficients for repeated samples were determined. Repeatability and agreement for NETRA were assessed with Bland-Altman plots, coefficients of repeatability ([Formula: see text] ; [Formula: see text] is the SD of differences) and intraclass correlation coefficients (ICCs). RESULTS: Bland-Altman plots, within-subject SD (sw ), coefficients of repeatability and ICC indicated that repeated measurements were similar for many but not all eyes and there was good agreement (ICC=0.96) for the spherical coefficient (F I=M) but less so for antistigmatic coefficients (F J=J 0 and F K=J 45) of power. Although mean differences for repeated samples were almost zero, 95% limits of agreement widths were larger for the stigmatic coefficients. Without cycloplegia, repeatability (2.77sw ) was 1.63 D, 0.58 D and 0.56 D for the stigmatic and antistigmatic coefficients, respectively. CONCLUSION: NETRA is a potentially useful and inexpensive portable method in clinical and primary health settings, and especially in less-developed regions of the world. The subjective nature of the self-refraction task can be challenging for younger individuals, and cycloplegia is recommended for NETRA with such patients.


Subject(s)
Presbyopia , Refraction, Ocular , Humans , Female , Child , Adolescent , Young Adult , Adult , Middle Aged , Male , Vision Tests , Cornea , Face
2.
BMJ Open Ophthalmol ; 7(1): e000851, 2022.
Article in English | MEDLINE | ID: mdl-35452206

ABSTRACT

Objective: The NETRA (Near Eye Tool for Refractive Assessment) is a smartphone-based refractive tool that allows for self-evaluation of refractive error. This study investigates the validity of the NETRA with and without cycloplegia to non-cycloplegic subjective refractions (SR). Methods and analysis: Participants underwent NETRA measurements without cycloplegia, and again after the administration of cycloplegia (cyclopentolate hydrochloride 1%). Non-cycloplegic SR were also performed. Variation of refractive measurements in symmetric dioptric power space were investigated using stereo-pair comets, hypothesis tests for variances and means. Bland-Altman plots were applied to better understand validity of the NETRA against non-cycloplegic SR. Coefficients of repeatability and intraclass correlation coefficients were also determined. Results: The sample included 22 women (64.7%) and 12 men (35.3%); most were indigenous Africans (52.9%) with mean age and SD of 20.24±1.95 years. Variation of refractive measurements were mainly stigmatic (spherical), and variation of NETRA measurements decreased after cycloplegia. The pre-cycloplegia NETRA measurements (and their means) for the right and left eyes were more negative (myopic) in power than the post-cycloplegia NETRA measurements and means. On average, eyes were approximately 1.25 D more myopic with the NETRA without cycloplegia. With cycloplegia, NETRA results were in closer agreement with non-cycloplegic SR for the same eyes. Conclusion: NETRA validity to SR, even in the absence of cycloplegia, suggests the instrument may be useful in geographical regions where self-refractions might be potentially helpful in addressing limitations in eye and vision care.


Subject(s)
Myopia , Presbyopia , Refractive Errors , Cyclopentolate , Female , Humans , Male , Mydriatics , Refraction, Ocular , Refractive Errors/diagnosis , Vision Tests
3.
BMJ Open Ophthalmol ; 7(1): e000929, 2022.
Article in English | MEDLINE | ID: mdl-35452207

ABSTRACT

Myopia is a global healthcare concern and effective analyses of dioptric power are important in evaluating potential treatments involving surgery, orthokeratology, drugs such as low-dose (0.05%) atropine and gene therapy. This paper considers issues of concern when analysing refractive state such as data normality, transformations, outliers and anisometropia. A brief review of methods for analysing and representing dioptric power is included but the emphasis is on the optimal approach to understanding refractive state (and its variation) in addressing pertinent clinical and research questions. Although there have been significant improvements in the analysis of refractive state, areas for critical consideration remain and the use of power matrices as opposed to power vectors is one such area. Another is effective identification of outliers in refractive data. The type of multivariate distribution present with samples of dioptric power is often not considered. Similarly, transformations of samples (of dioptric power) towards normality and the effects of such transformations are not thoroughly explored. These areas (outliers, normality and transformations) need further investigation for greater efficacy and proper inferences regarding refractive error. Although power vectors are better known, power matrices are accentuated herein due to potential advantages for statistical analyses of dioptric power such as greater simplicity, completeness, and improved facility for quantitative and graphical representation of refractive state.


Subject(s)
Anisometropia , Myopia , Refractive Errors , Humans , Myopia/therapy , Prescriptions , Refraction, Ocular , Refractive Errors/therapy
SELECTION OF CITATIONS
SEARCH DETAIL
...