1.
Heliyon ; 10(11): e32214, 2024 Jun 15.
Article in English | MEDLINE | ID: mdl-38912496

ABSTRACT

Typically, parasitic capacitances exist between the ground and the solar panel terminals in grid-connected PV systems. These parasitic capacitances provide a path for a leakage current, which leads to significant safety concerns, observable and seriously hazardous harmonic orders aligned with the injected grid current, and significant safety difficulties. In this research, a robust PWM controlling method that used competently in reducing the level of the leakage current and improving the power quality of a switched-capacitor Multilevel Inverter. This technique creates developed reference signals from the main signal to generate the switching scheme for the converter circuit. Additionally, the suggested control strategy only works with a small number of carrier signals, resulting in a quick system response and a simpler controller algorithm. Likewise, this controlling approach offers a stable way to maintain a constant output voltage in the suggested converter by adjusting the switching capacitors' voltages, which is not possible with traditional control techniques. MATLAB/Simulink is used to simulate the outcomes for both the suggested control approach and the traditional Phase Disposition (PD) PWM control method whereas the leakage current component reduces to 25 % compared to the captured component with the PDPWM. The simulation and the practical results based on the dSPACE-1103 hardware are quite similar.