1.
Cureus ; 15(10): e47011, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37965404

ABSTRACT

BACKGROUND: Congenital heart disease (CHD) is a common occurrence in live births, with some exhibiting critical congenital heart disease; therefore, cardiology services should be available around the clock to ensure timely diagnosis and management. This study aims to describe the workload and the need for pediatric cardiac services in a maternity hospital for newborn referrals. Moreover, the study describes the indications for neonatal cardiology consultations. METHODS: The prospective cohort study was conducted over four months, from January to April 2022, in the Prince Sultan Cardiac Center Al Qassim region of Saudi Arabia. Prince Sultan Cardiac Center's pediatric cardiology department provides cardiac services to the Maternity and Children Hospital Buraidah Al Qassim. Out of the total 2,606 live births during the study period, the cardiology team evaluated 352 neonates. Neonates less than 30 days of age who were born in the maternity hospital were enrolled in the study. The outborn babies referred from other centers as suspected congenital heart disease for whom a cardiac evaluation was done were excluded. In addition, babies assessed in the emergency room and born elsewhere were excluded. Only new consultations have been considered, excluding follow-up consultations. STATISTICAL ANALYSIS: Data about patients' demographic, clinical and echocardiographic findings were recorded on Google Forms and converted to a Google spreadsheet. The Google spreadsheet's inbuilt statistical software was used for analysis. Categorical data were presented as percentages, and numerical data as median and range. RESULTS: The cardiology team evaluated 352 neonates from 2,606 live births over four months, accounting for 13.5 per 100 live births. The median weight was 2.8 kilograms, with a 0.5-4.3 kilogram range. Males comprised 187 (53%), and females comprised 165 (47%). Moreover, full-term, preterm, and post-term accounted for 236 (67%), 113 (32%), and 3 (0.8%) of patients, respectively. The common indications for neonatal cardiac referral were respiratory distress 60 (17%), infants born to diabetic mothers 50 (14%), abnormal fetal echocardiogram 49 (13.9%), family history of abortion or neonatal death 31 (8.8%), and congenital anomalies 30 (8.5%). Systolic murmur was the commonest clinical finding that prompted cardiology referrals 82 (23.2%), followed by desaturation 38 (10.7%) and dysmorphic features 31 (8.8%). Among the congenital cardiac defects, an isolated atrial septal defect (ASD) was seen in 66 (18.5%), isolated patent ductus arteriosus in 50 (14.2%), and ventricular septal defect in 21 (5.9%). Moreover, 13 (4.4%) lesions were critical CHDs. Finally, 27 (7.6%) had a diagnosis of pulmonary hypertension. CONCLUSION: Knowing the burden of neonatal cardiac assessment on pediatric cardiology services in any maternity center may help the healthcare authorities to allocate resources and optimize the delivery of cardiac services among the neonatal population. Properly allocating pediatric cardiologists to the needed centers may optimize neonatal cardiac services. Moreover, it may decide on the number of pediatric cardiologists that need to be trained each year to meet the requirements of neonatal cardiac services.

2.
Neonatology ; 119(1): 18-25, 2022.
Article in English | MEDLINE | ID: mdl-34724661

ABSTRACT

INTRODUCTION: Electrical velocimetry (EV) offers a noninvasive tool for continuous cardiac output (CO) measurements which might facilitate hemodynamic monitoring and targeted therapy in low birth neonates, in whom other methods of CO measurement are not practicably feasible. METHODS: This prospective observational study compared simultaneous cardiac output measurements by electrical velocimetry (COEV) with transthoracic echocardiography (COTTE) in extremely low birth weight (ELBW) neonates in the neonatal intensive care unit (NICU). Echocardiography was performed by 1 single examiner. Data were analyzed by Bland-Altman analysis and independent-samples analysis of variance. A mean percentage error (MPE) of <30% and limits of agreement (LOA) up to ±30% were considered clinically acceptable. RESULTS: Thirty-eight ELBW neonates were studied and yielded 85 pairs of COEV and COTTE measurements. Bland-Altman analysis showed an overall bias (the mean difference) and LOA of -126 and -305 to +52 mL min-1, respectively, and an MPE of 66%. Patients with patent ductus arteriosus had a higher bias with LOA and MPE of -166.8, -370.7 to +37 mL min-1, and 69%, respectively. The overall true precision was 58%. CONCLUSION: This study showed high bias and lack of agreement between EV and TTE for measurement of CO in ELBW infants in NICU, limiting applicability of EV to monitor absolute values.


Subject(s)
Ductus Arteriosus, Patent , Infant, Extremely Low Birth Weight , Cardiac Output , Echocardiography/methods , Humans , Infant , Infant, Newborn , Monitoring, Physiologic/methods , Reproducibility of Results , Rheology/methods
3.
Am J Blood Res ; 10(6): 397-406, 2020.
Article in English | MEDLINE | ID: mdl-33489449

ABSTRACT

Public prophylaxis to decrease the emergence of new daily COVID-19 cases is vital. Adjuvant TaibUVID nutritional supplements are promising home-made or hospital-made supplements suggested for rapidly preventing and treating COVID-19 pandemic. We report here a 44 years old male physician who caught COVID-19 infection at hospital in Egypt with confirmed positive nasopharyngeal swab PCR. Ethical committee approval and informed patient's consent were gained before performing this study. Chest X-ray revealed increased bronchovascular markings. Close follow-up was done with no treatment given and he was sent for home isolation. Few days later, he developed progressive non-productive cough and a sense of difficult breathing with no associated fever or chest pain. An antitussive drug was given to him. The patient read about TaibUVID supplements from social media and started to feel improvement after TaibUVID inhalation therapy (using the heated solution of nigella sativa and chamomile five times a day). He also received a home-made TaibUVID nutritional supplement (nigella sativa, chamomile and natural honey) five times daily for four consecutive days. The next day, he was quite better with mild symptoms. Two days later, nasopharyngeal swab PCR was negative while other patients still had positive nasopharyngeal swabs. As few attacks of mild cough and breathing difficulty existed, he was admitted to hospital. A nasopharyngeal swab PCR was done for him again and the result was negative also. Blood gases were normal. He had lymphocytosis (possibly due to TaibUVID effects) that counteract lymphopenia seen in COVID-19 patients. Biochemical and hematological evaluation were quite normal apart from increased serum chloride and lactate dehydrogenase. There was a mild decrease in serum CO2 and alkaline phosphatase. Chest CT report revealed symmetrically inflated both lungs with non-specific focal nodular infiltrates (scattered in basal and medial lung segments) in left lower lobes with faint ground glass opacities. He was discharged home. Few days later, he was quite improved with no symptoms and returned to his work comfortably. In conclusion, TaibUVID nutritional supplements may be effective in rapidly changing the nasopharyngeal swab PCR from positive to negative. TaibUVID nutritional supplements are advisable as a natural, safe and effective prophylaxis to stop COVID-19 infectiousness, transmission and emergence of new cases. Clinical studies to investigate TaibUVID nutritional benefits are strongly recommended. TaibUVID may be promising and recommended for public prophylaxis to decrease emergence of new COVID-19 cases.

4.
Am J Blood Res ; 10(6): 447-458, 2020.
Article in English | MEDLINE | ID: mdl-33489454

ABSTRACT

Thalassemia is a major health problem in affected children due to iron overload, increased oxidative stress, atherogenic lipid profile and tissue-damage. This study aims at investigating the cardioprotective and tissue-protective benefits of Al-hijamah and their impact on cell-mediated immunity for treating thalassemic children. This study aimed also at investigating the tissue-clearance principle of Taibah mechanism: whenever pathological substances are to be cleared from the human body, Al-hijamah is indicated. Al-hijamah was done to thalassemic children (15 males and 5 females having a mean age of 9.07 ± 4.26 years) using sterile disposable sets in a complete aseptic hospital environment. Prior ethical committee agreement (in addition to written patient's consents) was obtained from Tanta Faculty of Medicine, Egypt. Twenty thalassemic children received iron chelation therapy plus Al-hijamah for one session (30-60 minutes) versus an age and sex-matched thalassemic control group treated with iron chelation therapy only. Al-hijamah is a quite safe outpatient hematological procedure that significantly decreased serum cholesterol (from 129.75 ± 3.67 to 103.5 ± 4.18 mg/dl) and decreased serum triglycerides (from 109.25 ± 8.96 to 91.95 ± 7.22 mg/dl). Interestingly, Al-hijamah exerted significant tissue-protective effects (it decreased serum GPT from 98.65 ± 12.27 to 71.65 ± 32.78 U/L and serum GOT from 96.35 ± 14.33 to 69.35 ± 34.37 U/L). Al-hijamah-induced ferritin excretion caused decreased serum ferritin (high serum ferritin negatively correlated with cell mediated immunity). Al-hijamah exerted cardioprotective and tissue-protective and hypolipidemic effects. Al-hijamah decreased serum cholesterol and is cardioprotective for thalassemic patients as it protects against atherogenesis and atherosclerosis. Medical practice of Al-hijamah is strongly recommended in hospitals. Al-hijamah cleared blood significantly from causative pathological substances e.g. serum ferritin resulting in enhanced cell-mediated immunity (in agreement with the evidence-based Taibah mechanism).

5.
Neonatology ; 112(1): 40-46, 2017.
Article in English | MEDLINE | ID: mdl-28253519

ABSTRACT

BACKGROUND: Pulse oximetry is widely used in intensive care and emergency conditions to monitor arterial oxygenation and to guide oxygen therapy. OBJECTIVE: To study the reliability of pulse oximetry in comparison with CO-oximetry in newborn piglets during progressive hypoxia, cardiac arrest, cardiopulmonary resuscitation (CPR), and after return of spontaneous circulation (ROSC). METHODS: Thirty-three newborn piglets were exposed to hypoxia until asystole occurred and then resuscitated until ROSC. Arterial oxygen saturation was monitored continuously by pulse oximetry (SpO2) with one sensor applied to the wrist of the right forelimb (FL) and another to the thigh of the left hind limb (HL). Arterial functional oxygen saturation (SaO2) was measured at baseline and at predefined intervals during each phase of the experiment. SpO2 was compared with coinciding SaO2 values and bias considered whenever the difference (SpO2 - SaO2) was beyond ±5%. RESULTS: Bias values were lower at the baseline measurements (-3.7 ± 2.3% in FL and -4.1 ± 3.4% in HL) as well as after ROSC (1.5 ± 4.2% in FL and 0.2 ± 4.6% in HL) with higher precision and accuracy than during other experiment phases. During hypoxia induction, cardiac arrest, and CPR, there was a marked decrease in precision and accuracy as well as an increase in bias up to 43 ± 26 and 56 ± 27% in FL and HL, respectively, over a range of SaO2 from 13 to 51%. CONCLUSION: Pulse oximetry showed increased bias and decreased accuracy and precision during marked hypoxemia in a model of neonatal hypoxic cardiac arrest.


Subject(s)
Cardiopulmonary Resuscitation , Forelimb/blood supply , Heart Arrest/therapy , Hindlimb/blood supply , Hypoxia/complications , Oximetry , Oxygen/blood , Animals , Animals, Newborn , Biomarkers/blood , Disease Models, Animal , Heart Arrest/blood , Heart Arrest/etiology , Heart Arrest/physiopathology , Hypoxia/blood , Hypoxia/physiopathology , Predictive Value of Tests , Regional Blood Flow , Reproducibility of Results , Sus scrofa , Time Factors
6.
Neonatology ; 108(2): 108-14, 2015.
Article in English | MEDLINE | ID: mdl-26107742

ABSTRACT

BACKGROUND: Noninvasive ventilation is increasingly used in very-low-birth-weight infants (VLBWI) to reduce complications that occur with invasive ventilation. However, the physiological effects of synchronization during noninvasive nasal intermittent mandatory ventilation (IMV) have not been tested in VLBWI immediately after extubation. OBJECTIVE: We aimed to study the short-term effects of synchronized nasal IMV (S-NIMV) compared to nonsynchronized nasal IMV (NIMV) on breathing effort as measured by phasic esophageal pressure (Pe) deflection, spontaneous respiratory rate (RR), gas exchange, cerebral tissue oxygen saturation (StO2) and intermittent episodes of bradycardia or hypoxemia in VLBWI recovering from respiratory distress syndrome (RDS). METHODS: Fourteen VLBWI recovering from RDS were studied using a randomized cross-over design during both S-NIMV and NIMV (of 2 h each) immediately after extubation. RESULTS: Phasic Pe deflection, spontaneous RR and transcutaneous PCO2 decreased significantly while transcutaneous PO2 and synchrony rate (defined as peak ventilator pressure delivered within the first half of spontaneous inspiration) increased significantly during S-NIMV compared to during NIMV. There was no difference in blood pressure, average arterial oxygen saturation (SpO2), cerebral StO2, fractional tissue oxygen extraction of the brain and severe bradycardia (defined as time with a heart rate <100 beats/min lasting ≥10 s) and in hypoxemic episodes (SpO2 <80%) between the two modes. CONCLUSION: Synchronization during nasal ventilation immediately after extubation in VLBWI recovering from RDS improved gas exchange and decreased the respiratory effort, and it could therefore be considered to provide a more efficient respiratory support and synchrony.


Subject(s)
Airway Extubation , Infant, Premature , Infant, Very Low Birth Weight , Intermittent Positive-Pressure Ventilation/methods , Pulmonary Gas Exchange , Respiratory Distress Syndrome, Newborn/therapy , Blood Pressure , Bradycardia , Cross-Over Studies , Female , Germany , Humans , Hypoxia , Infant, Newborn , Male , Respiratory Distress Syndrome, Newborn/complications
7.
Neonatology ; 107(2): 113-9, 2015.
Article in English | MEDLINE | ID: mdl-25471619

ABSTRACT

BACKGROUND: Pulse oximetry is widely used in intensive care and emergency conditions to monitor arterial oxygenation and to guide oxygen therapy. OBJECTIVE: To study the reliability of pulse oximetry in comparison with CO-oximetry in newborn piglets during cardiopulmonary resuscitation (CPR). METHODOLOGY: In a prospective cohort study in 30 healthy newborn piglets, cardiac arrest was induced, and thereafter each piglet received CPR for 20 min. Arterial oxygen saturation was monitored continuously by pulse oximetry (SpO2). Arterial blood was analyzed for functional oxygenation (SaO2) every 2 min. SpO2 was compared with coinciding SaO2 values and bias considered whenever the difference (SpO2 - SaO2) was beyond ±5%. RESULTS: Bias values were decreased at the baseline measurements (mean: 2.5 ± 4.6%) with higher precision and accuracy compared with values across the experiment. Two minutes after cardiac arrest, there was a marked decrease in precision and accuracy as well as an increase in bias up to 13 ± 34%, reaching a maximum of 45.6 ± 28.3% after 10 min over a mean SaO2 range of 29-58%. CONCLUSION: Pulse oximetry showed increased bias and decreased accuracy and precision during CPR in a model of neonatal cardiac arrest. We recommend further studies to clarify the exact mechanisms of these false readings to improve reliability of pulse oximetry during the marked desaturation and hypoperfusion found during CPR.


Subject(s)
Cardiopulmonary Resuscitation , Heart Arrest/blood , Oximetry/methods , Oxygen/analysis , Animals , Animals, Newborn , Disease Models, Animal , Monitoring, Physiologic , Prospective Studies , Reproducibility of Results , Swine