Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add more filters










Database
Language
Publication year range
1.
J Pediatr ; 223: 51-56.e1, 2020 08.
Article in English | MEDLINE | ID: mdl-32482392

ABSTRACT

OBJECTIVE: To evaluate changes in cerebral oxygenation, peripheral arterial oxygenation, respiratory status, and administered fraction of inspired oxygen during the first 10 minutes of life in premature infants receiving umbilical cord milking compared with delayed cord clamping (DCC). STUDY DESIGN: Premature infants born at 230/7 to 276/7 weeks of gestation were randomized to umbilical cord milking or DCC. A near infrared spectroscopy sensor, pulse oximeter, and electrocardiogram electrodes were placed. Pulse rate, cerebral tissue oxygenation, peripheral oxygen saturation, airway pressure, and fraction of inspired oxygen were collected for 10 minutes in the delivery room. Longitudinal models were used to compare effects of umbilical cord milking and DCC. RESULTS: Fifty-six infants had cerebral oximetry and advanced monitoring at birth. There was an increased incidence of severe intraventricular hemorrhage in infants who received umbilical cord milking compared with DCC (P = .0211). Longitudinal models suggested that peripheral oxygen saturation was higher in the umbilical cord milking group in the first 4 minutes (P = .0221) and that mean airway pressures were lower in the umbilical cord milking group after the first 7 minutes (P = .0072). No statistical differences were observed for fraction of inspired oxygen, cerebral tissue oxygenation, or heart rates. CONCLUSIONS: The data suggest that the rapid transfer of blood during umbilical cord milking may facilitate lung expansion with improved pulmonary blood flow, but may also increase cerebral blood flow, resulting in severe intraventricular hemorrhage. TRIAL REGISTRATION: ClinicalTrials.gov: NCT03145142.


Subject(s)
Cerebrovascular Circulation , Delivery, Obstetric/methods , Hemodynamics/physiology , Lung/blood supply , Umbilical Cord/blood supply , Adult , Cerebral Intraventricular Hemorrhage/etiology , Delivery, Obstetric/adverse effects , Female , Humans , Infant, Extremely Premature , Infant, Newborn , Pregnancy , Pregnancy Outcome/epidemiology , Spectroscopy, Near-Infrared , Time Factors
2.
J Perinatol ; 39(12): 1635-1639, 2019 12.
Article in English | MEDLINE | ID: mdl-31488904

ABSTRACT

OBJECTIVE: To determine differences in the duration and level of resuscitation between infants that achieve a peripheral oxygen saturation (SpO2) of 80% by 5 min compared with those who remain below 80% saturation. STUDY DESIGN: Infants < 32 weeks GA were analyzed. Pulse rate, SpO2, airway pressure, and fraction of inspired oxygen were collected during the first 10 min of life. RESULTS: Two hundred and eighty-four infants were analyzed of which 100 had SpO2 < 80% at 5 min of life. Composite outcome of death and any IVH was greater in the <80% at 5 min group. These infants had lower heart rates and lower SpO2 despite increased mean airway pressure and higher FiO2 (p < 0.001). CONCLUSION: Infants <32 weeks GA that do not achieve a peripheral arterial saturation of 80% by 5 min of life experience more death or severe IVH. This association is amongst the strongest seen of any predictor of morbidity in the delivery room.


Subject(s)
Infant, Premature, Diseases/mortality , Infant, Premature/blood , Oxygen Inhalation Therapy , Oxygen/blood , Resuscitation , Cerebral Intraventricular Hemorrhage/etiology , Continuous Positive Airway Pressure , Delivery Rooms , Female , Gestational Age , Humans , Infant, Newborn , Infant, Premature, Diseases/epidemiology , Infant, Premature, Diseases/therapy , Male , Oxygen/administration & dosage , Oxygen Inhalation Therapy/adverse effects , Prognosis , Retinopathy of Prematurity/etiology , Retrospective Studies , Treatment Outcome
3.
Front Pediatr ; 6: 100, 2018.
Article in English | MEDLINE | ID: mdl-29755962

ABSTRACT

BACKGROUND: While delayed umbilical cord clamping in preterm infants has shown to improve long-term neurological outcomes, infants who are thought to need resuscitation do not receive delayed cord clamping even though they may benefit the most. A mobile resuscitation platform allows infants to be resuscitated at the mother's bedside with the cord intact. The newborn is supplied with placental blood during the resuscitation in view of the mother. The objective of the study is to assess the usability and acceptability of mobile resuscitation platform, LifeStart trolley, among the infants' parents and perinatal providers. METHODS: A resuscitation platform was present during every delivery that required advanced neonatal providers for high-risk deliveries. Perinatal providers and parents of the infants were given a questionnaire shortly after the delivery. RESULTS: 60 neonatal subjects were placed on the trolley. The majority of deliveries were high risk for meconium-stained amniotic fluid (43%), and non-reassuring fetal heart rate (45%). About 50% of neonatal providers felt that there were some concerns regarding access to the baby. No parents were uncomfortable with the bedside neonatal interventions, and most parents perceived that communication was improved because of the proximity to the care team. CONCLUSION: Bedside resuscitation with umbilical cord intact through the use of a mobile resuscitation trolley is feasible, safe, and effective, but about half of the perinatal providers expressed concerns. Logistical issues such as improved space management and/or delivery setup should be considered in centers planning to perform neonatal resuscitation with an intact cord.

4.
BMC Pregnancy Childbirth ; 18(1): 131, 2018 May 04.
Article in English | MEDLINE | ID: mdl-29728153

ABSTRACT

BACKGROUND: In 2015, the American Academy of Pediatrics recommended delayed umbilical cord clamping for at least 30-60 s for all infants. However, there is limited data regarding the maternal safety of delayed cord clamping in multiple pregnancies. We aimed to compare the maternal bleeding complications following early cord clamping (ECC) versus of delayed cord clamping (DCC) in multiple pregnancies. METHODS: A retrospective cohort study of pregnant women with multiples who delivered live-born infants at Sharp Healthcare Hospitals in San Diego, CA, USA during January 1st, 2016 - September 30th, 2017. Bleeding complications of 295 women who underwent ECC (less than 30 s) were compared with 154 women who underwent DCC (more than 30 s). ECC or DCC was performed according to individual obstetrician discretion. RESULTS: Four hundred forty-nine women with multiple pregnancies (N = 910 infants) were included in the study. 252 (85.4%) women underwent cesarean section in ECC group vs. 99 (64.3%) in DCC group. 58 (19.7%) women delivered monochorionic twins in ECC group vs. 32 (20.8%) women in DCC group. There was no increase in maternal estimate blood loss when DCC was performed comparing to ECC. There were no differences in operative time, post-delivery decrease in hematocrits, rates of postpartum hemorrhage, bleeding complications, maternal blood transfusions and therapeutic hysterectomy between the two groups. CONCLUSIONS: No differences in maternal bleeding complications were found with DCC in multiple pregnancies compared to ECC. Delayed cord clamping can be done safely in multiple pregnancies without any increased maternal risk.


Subject(s)
Delivery, Obstetric/adverse effects , Postpartum Hemorrhage/etiology , Pregnancy, Multiple , Adult , Blood Transfusion , Cesarean Section/adverse effects , Constriction , Female , Hematocrit , Humans , Hysterectomy , Operative Time , Pregnancy , Retrospective Studies , Time Factors , Umbilical Cord
5.
Respir Care ; 63(8): 943-949, 2018 08.
Article in English | MEDLINE | ID: mdl-29615483

ABSTRACT

BACKGROUND: Permissive hypercapnia is a lung-protection strategy. We sought to review our current clinical practice for the range of permissive hypercapnia and identify the relationship between PaCO2 and pH and adverse outcomes. METHODS: A secondary analysis of a delayed cord-clamping clinical trial was performed on all arterial blood gas tests in the first 72 h in infants < 32 weeks gestational age. All arterial blood gas values were categorized into a clinical range to determine the percent likelihood of occurring in the total sample. The univariate and multivariate relationships of severe adverse events and the time-weighted PaCO2 , fluctuation of PaCO2 , maximal and minimal PaCO2 , base excess, and pH were assessed. RESULTS: 147 infants with birthweight of 1,206 ± 395 g and gestational age of 28 ± 2 weeks were included. Of the 1,316 total samples, < 2% had hypocapnia (PaCO2 <30 mm Hg), 47% were normocapnic (PaCO2 35-45 mm Hg), 26.5% had mild hypercapnia (PaCO2 45-55 mm Hg), 13% had moderate hypercapnia (PaCO2 55-65 mm Hg), and 6.5% had severe hypercapnia (PaCO2 ≥ 65 mm Hg). There were no adverse events associated with hypocapnia. Subjects with death/severe intraventricular hemorrhage had a higher mean PaCO2 of 52.3 versus 44.7 (odds ratio [OR] 1.16, 95% CI 1.04-1.29, P = .006), higher variability of PaCO2 with a standard deviation of 12.6 versus 7.8 (OR 1.15, 95% CI 1.03-1.27, P = .01), and a lower minimum pH of 7.03 versus 7.23 (OR 0, 95% CI 0-0.06, P = .003). There was no significant difference in any variables in subjects who developed other adverse events. CONCLUSION: The routine targeting of higher than normal PaCO2 goals may lead to a low incidence of hypocapnia and associated adverse events. Hypercapnia is common, and moderate hypercapnia may increase the risk of neurologic injury and provide little pulmonary benefit.


Subject(s)
Acidosis/blood , Cerebral Intraventricular Hemorrhage/blood , Hypercapnia/blood , Hypocapnia/blood , Respiration, Artificial/methods , Acid-Base Imbalance/blood , Acidosis/complications , Blood Gas Analysis , Carbon Dioxide , Female , Humans , Hydrogen-Ion Concentration , Hypercapnia/complications , Hypocapnia/complications , Incidence , Infant , Infant Death , Infant, Newborn , Infant, Premature/blood , Male , Partial Pressure , Randomized Controlled Trials as Topic , Respiration, Artificial/adverse effects
6.
J Pediatr ; 198: 209-213.e3, 2018 07.
Article in English | MEDLINE | ID: mdl-29680471

ABSTRACT

OBJECTIVE: To determine whether monitoring cerebral oxygen tissue saturation (StO2) with near-infrared spectroscopy (NIRS) and brain activity with amplitude-integrated electroencephalography (aEEG) can predict infants at risk for intraventricular hemorrhage (IVH) and death in the first 72 hours of life. STUDY DESIGN: A NIRS sensor and electroencephalography leads were placed on 127 newborns <32 weeks of gestational age at birth. Ten minutes of continuous NIRS and aEEG along with heart rate, peripheral arterial oxygen saturation, fraction of inspired oxygen, and mean airway pressure measurements were obtained in the delivery room. Once the infant was transferred to the neonatal intensive care unit, NIRS, aEEG, and vital signs were recorded until 72 hours of life. An ultrasound scan of the head was performed within the first 12 hours of life and again at 72 hours of life. RESULTS: Thirteen of the infants developed any IVH or died; of these, 4 developed severe IVH (grade 3-4) within 72 hours. There were no differences in either cerebral StO2 or aEEG in the infants with low-grade IVH. Infants who developed severe IVH or death had significantly lower cerebral StO2 from 8 to 10 minutes of life. CONCLUSIONS: aEEG was not predictive of IVH or death in the delivery room or in the neonatal intensive care unit. It may be possible to use NIRS in the delivery room to predict severe IVH and early death. TRIAL REGISTRATION: ClinicalTrials.gov: NCT02605733.


Subject(s)
Brain/physiopathology , Cerebral Hemorrhage/etiology , Cerebral Hemorrhage/mortality , Infant, Premature, Diseases/etiology , Infant, Premature, Diseases/mortality , Spectroscopy, Near-Infrared , Electroencephalography , Female , Humans , Infant, Newborn , Infant, Premature , Male , Predictive Value of Tests , Prospective Studies , Resuscitation
7.
J Perinatol ; 38(3): 240-244, 2018 03.
Article in English | MEDLINE | ID: mdl-29234144

ABSTRACT

OBJECTIVE: To determine if umbilical cord milking is detrimental in compromised term/near-term infants. STUDY DESIGN: A retrospective analysis of infants with abnormal cord gases (cord arterial or venous pH of ≤ 7.1 or base deficit > -12). We collected maternal risk factors, cord management, birth, and neonatal outcomes during hospitalization. RESULT: We found 157 infants who met the criteria for abnormal cord gases. Thirty-six of those had umbilical cord milking at delivery. There was no significant difference in neonatal outcomes, but fewer infants in the cord milking group needed resuscitation (38 vs. 56%, p = 0.07) and ongoing respiratory support (19 vs. 31%, p = 0.16) compared to the immediate clamping group. CONCLUSIONS: While not significant, infants who received cord milking at birth needed less resuscitation and ongoing respiratory support. This study suggests that umbilical cord milking appears to be a safe therapy when acidosis is present and when resuscitation is needed.


Subject(s)
Acidosis/physiopathology , Term Birth/blood , Umbilical Cord/surgery , Child Development/physiology , Constriction , Female , Hematocrit , Humans , Infant, Newborn , Male , Retrospective Studies
8.
PLoS One ; 12(11): e0187730, 2017.
Article in English | MEDLINE | ID: mdl-29099872

ABSTRACT

BACKGROUND: The seventh edition of the American Academy of Pediatrics Neonatal Resuscitation Program recommends the use of a cardiac monitor in infants that need resuscitation. Previous trials have shown that EKG heart rate is available before pulse rate from a pulse oximeter. To date no trial has looked at how the availability of electrocardiogram (EKG) affects clinical interventions in the delivery room. OBJECTIVE: To determine whether the availability of an EKG heart rate value and tracing to the clinical team has an effect on physiologic measures and related interventions during the stabilization of preterm infants. DESIGN/METHODS: Forty (40) premature infants enrolled in a neuro-monitoring study (The Neu-Prem Trial: NCT02605733) who had an EKG monitor available were randomized to have the heart rate information from the bedside EKG monitor either displayed or not displayed to the clinical team. Heart rate, oxygen saturation, FiO2 and mean airway pressure from a data acquisition system were recorded every 2 seconds. Results were averaged over 30 seconds and the differences analyzed using two-tailed t-test. Interventions analyzed included time to first change in FiO2, first positive pressure ventilation, first increase in airway pressure, and first intubation. RESULTS: There were no significant differences in time to clinical interventions between the blinded and unblinded group, despite the unblinded group having access to a visible heart rate at 66 +/- 20 compared to 114 +/- 39 seconds for the blinded group (p < .0001). Pulse rate from oximeter was lower than EKG heart rate during the first 2 minutes of life, but this was not significant. CONCLUSION(S): EKG provides an earlier, and more accurate heart rate than pulse rate from an oximeter during stabilization of preterm infants, allowing earlier intervention. All interventions were started earlier in the unblinded EKG group but these numbers were not significant in this small trial. Earlier EKG placement before pulse oximeter placement may affect other interventions, but this needs further study.


Subject(s)
Electrocardiography/methods , Resuscitation , Female , Humans , Infant, Newborn , Infant, Premature , Male , Monitoring, Physiologic , Pilot Projects
9.
J Pediatr ; 187: 313-317.e1, 2017 08.
Article in English | MEDLINE | ID: mdl-28526223

ABSTRACT

Infants may benefit if resuscitation could be provided with an intact umbilical cord. Infants identified at risk for resuscitation were randomized to 1- or 5-minute cord clamping. The 5-minute group had greater cerebral oxygenation and blood pressure. Studies are needed to determine whether this translates into improved outcomes. TRIAL REGISTRATION: ClinicalTrials.gov: NCT02827409.


Subject(s)
Delivery, Obstetric/methods , Resuscitation/methods , Umbilical Cord/surgery , Constriction , Feasibility Studies , Female , Humans , Infant, Newborn , Male , Pregnancy , Risk , Term Birth , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...