Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 17 de 17
Filter
Add more filters










Publication year range
1.
J Phys Chem C Nanomater Interfaces ; 127(44): 21768-21776, 2023 Nov 09.
Article in English | MEDLINE | ID: mdl-37969924

ABSTRACT

The conjugation of ionic gold with bacterial antibodies makes it possible to induce a specific interaction between targeted bacteria and the surface of a GaAs/AlGaAs biochip. The process of immobilization is based on a galvanic displacement reaction (GDR) involving electron transfer between GaAs and Au3+ ions that leads to the formation of a Au-Ga alloy anchoring bacteria to the biochip surface. The GDR-based immobilization of Escherichia coli on biochips comprising a stack of GaAs/AlGaAs nanolayers (dGaAs = 12 nm, dAlGaAs = 10 nm) was confirmed by X-ray photoelectron spectroscopy and atomic force microscopy-based infrared experiments. We report the successful application of this approach for highly sensitive detection of E. coli with a digital photocorrosion (DIP) biosensor. The photoluminescence (PL) monitored DIP of GaAs/AlGaAs nanolayers results in the formation of a PL intensity maximum whose temporal appearance depends on the electric charge transfer between bacteria and the biochip. The formation of a robust bacteria-biochip interface achieved with the GDR process allowed us to observe the role of bacteria on the temporal position of a PL intensity maximum related to the etching of two pairs of GaAs/AlGaAs nanolayers extending up to 24 nm below the biochip surface. We demonstrate the attractive detection of E. coli at 250 CFU/mL, and we discuss the potential of this approach for designing a family of biosensors addressing the quasi-continuous monitoring of a water environment for the presence of pathogenic bacteria.

2.
Sci Rep ; 13(1): 831, 2023 01 16.
Article in English | MEDLINE | ID: mdl-36646757

ABSTRACT

Monitoring the presence of pathogenic Bacillus spores is important for industrial applications, as well as necessary for ensuring human health. Bacillus thuringiensis is used as a biopesticide against several insect pests. Bacillus cereus spores are a significant cause of food poisoning, and Bacillus anthracis is a recognized biosecurity threat. Laboratory-based methods, such as polymerase chain reaction, enzyme-linked immunosorbent assay, or matrix-assisted laser desorption ionization spectroscopy provide sensitive detection of bacteria and spores, but the application of those methods for quasi-continuous environmental monitoring presents a significant challenge requiring frequent human intervention. To address this challenge, we developed a workstation for quasi-autonomous monitoring of water reservoirs for the presence of bacteria and spores, and designed and validated the functionality of a microprocessor-controlled module capable of repetitive collection and pre-concentration of spores in liquid samples tested with fiberglass (FG), polyether sulfone and polyvinylidene fluoride filters. The best results were obtained with FG filters delivering a 20× concentration of B. thuringiensis and B. cereus spores from saline suspensions. The successful 20× pre-concentration of Bacillus spores demonstrated with FG filters could be repeated up to 3 times when bleach decontamination is applied between filtrations. Taken together, our results demonstrate an attractive instrument suitable for semi-automated, quasi-continuous sampling and pre-processing of water samples for biosensing of bacterial spores originating from a complex environment.


Subject(s)
Bacillus anthracis , Bacillus thuringiensis , Bacillus , Humans , Bacillus cereus , Spores, Bacterial/chemistry
3.
ACS Omega ; 7(37): 33349-33357, 2022 Sep 20.
Article in English | MEDLINE | ID: mdl-36157789

ABSTRACT

This work reports on the potential of polymer brushes (PBs) grown on GaAs substrates (PB-GaAs) as a promising platform for the detection of Legionella pneumophila (Lp). Three functionalization approaches of the GaAs surface were used, and their compatibility with antibodies against Lp was evaluated using Fourier transform infrared spectroscopy and fluorescence microscopy. The incorporation of PBs on GaAs has allowed a significant improvement of the antibody immobilization by increased surface coverage. Bacterial capture experiments demonstrated the promising potential for enhanced immobilization of Lp in comparison with the conventional alkanethiol self-assembled monolayer-based biosensing architectures. Consistent with an eightfold improved capture of bacteria on the surface of a PB-functionalized GaAs/AlGaAs digital photocorrosion biosensor, we report the attractive detection of Lp at 500 CFU/mL.

4.
Microorganisms ; 10(7)2022 Jul 13.
Article in English | MEDLINE | ID: mdl-35889128

ABSTRACT

Bacillus cereus is a spore-forming ubiquitous bacterium notable as a food poisoning agent. Detection of B. cereus spores using selective media is laborious and non-specific. Herein, the quantitative detection of B. cereus spores was investigated with commercial antibodies and published aptamer sequences. Several detection reagents were screened for affinity to Bacillus collagen-like protein A (BclA), an abundant exosporium glycoprotein. Sensitivity and selectivity toward B. cereus spores were tested using immunoassays and multi-analyte profiling (xMAP). A recombinant antibody developed in llama against BclA protein showed B. cereus spore selectivity and sensitivity between 102 and 105 spores/mL using xMAP. DNA aptamer sequences demonstrated sensitivity from 103 to 107 spores/mL and no cross-reaction to B. megaterium and B. subtilis. Selectivity for B. cereus spores was also demonstrated in a mixture of several diverse microorganisms and within a food sample with no compromise of sensitivity. As proof of concept for multiplexed measurement of human pathogens, B. cereus and three other microorganisms, E. coli, P. aeruginosa, and S. cerevisiae, were simultaneously detected using xMAP. These data support the development of a rapid, sensitive, and selective system for quantitation of B. cereus spores and multiplexed monitoring of human pathogens in complex matrices.

5.
Biosensors (Basel) ; 12(6)2022 May 31.
Article in English | MEDLINE | ID: mdl-35735528

ABSTRACT

Since Legionella pneumophila has caused punctual epidemics through various water systems, the need for a biosensor for fast and accurate detection of pathogenic bacteria in industrial and environmental water has increased. In this report, we evaluated conditions for the capture of live L. pneumophila on a surface by polyclonal antibodies (pAb) and recombinant antibodies (recAb) targeting the bacterial lipopolysaccharide. Using immunoassay and PCR quantification, we demonstrated that, when exposed to live L. pneumophila in PBS or in a mixture containing other non-target bacteria, recAb captured one third fewer L. pneumophila than pAb, but with a 40% lower standard deviation, even when using the same batch of pAb. The presence of other bacteria did not interfere with capture nor increase background by either Ab. Increased reproducibility, as manifested by low standard deviation, is a characteristic that is coveted for biosensing. Hence, the recAb provided a better choice for immune adhesion in biosensors even though it was slightly less sensitive than pAb. Polyclonal or recombinant antibodies can specifically capture large targets such as whole bacteria, and this opens the door to multiple biosensor approaches where any of the components of the bacteria can then be measured for detection or characterisation.


Subject(s)
Legionella pneumophila , Immunoassay , Recombinant Proteins , Reproducibility of Results , Water , Water Microbiology
6.
Biosensors (Basel) ; 12(2)2022 Feb 09.
Article in English | MEDLINE | ID: mdl-35200365

ABSTRACT

Rapid detection of Legionella pneumophila (L. pneumophila) is important for monitoring the presence of these bacteria in water sources and preventing the transmission of the Legionnaires' disease. We report improved biosensing of L. pneumophila with a digital photocorrosion (DIP) biosensor functionalized with an innovative structure of cysteine-modified warnericin antimicrobial peptides for capturing bacteria that are subsequently decorated with anti-L. pneumophila polyclonal antibodies (pAbs). The application of peptides for the operation of a biosensing device was enabled by the higher bacterial-capture efficiency of peptides compared to other traditional ligands, such as those based on antibodies or aptamers. At the same time, the significantly stronger affinity of pAbs decorating the L. pneumophila serogroup-1 (SG-1) compared to serogroup-5 (SG-5) allowed for the selective detection of L. pneumophila SG-1 at 50 CFU/mL. The results suggest that the attractive sensitivity of the investigated sandwich method is related to the flow of an extra electric charge between the pAb and a charge-sensing DIP biosensor. The method has the potential to offer highly specific and sensitive detection of L. pneumophila as well as other pathogenic bacteria and viruses.


Subject(s)
Biosensing Techniques , Legionella pneumophila , Antibodies/chemistry , Antimicrobial Peptides/chemistry , Serogroup
7.
Talanta ; 236: 122813, 2022 Jan 01.
Article in English | MEDLINE | ID: mdl-34635209

ABSTRACT

Bacillus thuringiensis (Bt) is used as a bioinsecticide since it effectively kills insect larvae. Bt is also genetically similar to Bacillus cereus (Bc), a well recognized foodborne human pathogen; they are both members of the Bacillus cereus group (BC group). Although approved Bt bioinsecticide products have been confirmed to be non-pathogenic to humans, close monitoring of Bt during dissemination is important for cost considerations and to limit impact on biodiversity towards nontarget organisms. As such, developing rapid, sensitive, and specific tools for quantitative detection of Bt spores during and following spray operations is highly desirable. The goals of this study were to investigate commercially available detection reagents for sensitivity and selectivity in detecting Bt spores, and then functionalize a surface of (001) GaAs used in photonic biosensing. To achieve these goals, we (1) screened commercial antibodies for their capacity to bind recombinant proteins from Bt spores, (2) screened antibodies and aptamers for their sensitivity and selectivity against Bt spores, and (3) tested the efficiency of selected antibodies and aptamers in capturing Bt spores on the surface of functionalized GaAs biochips. Seven genes encoding Bt spore proteins were cloned and expressed in Escherichia coli. The binding of each purified spore antigen was tested by commercially available polyclonal and monoclonal antibodies claimed to exclusively target spores. Of the seven targets, Bacillus collagen-like protein A, was the most abundant protein on Bt spores and demonstrated the strongest binding affinity to all test antibodies. The commercial antibodies (Abs) were also tested for specificity to BC Group versus non-BC Group spores. Three of six commercial antibodies showed selectivity to Bt spores, with recombinant Abs providing the most robust lower range of detection (102 to 6 × 103 spores/mL). The sensitivity and selectivity of three published DNA aptamer sequences demonstrated a wide range of detection sensitivity for Bt spores. Two of the three test aptamers also showed reasonable selectivity towards Bt spores while the third demonstrated reactivity to non-BC Group B. megaterium and B. subtilis. Of the reagents tested, a thiolated aptamer and llama recombinant Ab showed highest Bt spore capture efficiency as measured by spore coverage of the GaAs surface. These results confirm that the selected aptamer and llama rAb can be considered strong candidates for the development of GaAs-based biosensing devices.


Subject(s)
Bacillus anthracis , Bacillus thuringiensis , Biosensing Techniques , Arsenicals , Bacillus thuringiensis/genetics , Gallium , Humans , Spores, Bacterial
8.
Biosensors (Basel) ; 11(5)2021 May 07.
Article in English | MEDLINE | ID: mdl-34067116

ABSTRACT

A regenerable bulk acoustic wave (BAW) biosensor is developed for the rapid, label-free and selective detection of Escherichia coli in liquid media. The geometry of the biosensor consists of a GaAs membrane coated with a thin film of piezoelectric ZnO on its top surface. A pair of electrodes deposited on the ZnO film allows the generation of BAWs by lateral field excitation. The back surface of the membrane is functionalized with alkanethiol self-assembled monolayers and antibodies against E. coli. The antibody immobilization was investigated as a function of the concentration of antibody suspensions, their pH and incubation time, designed to optimize the immunocapture of bacteria. The performance of the biosensor was evaluated by detection tests in different environments for bacterial suspensions ranging between 103 and 108 CFU/mL. A linear dependence between the frequency response and the logarithm of E. coli concentration was observed for suspensions ranging between 103 and 107 CFU/mL, with the limit of detection of the biosensor estimated at 103 CFU/mL. The 5-fold regeneration and excellent selectivity towards E. coli detected at 104 CFU/mL in a suspension tinted with Bacillus subtilis at 106 CFU/mL illustrate the biosensor potential for the attractive operation in complex biological media.


Subject(s)
Biosensing Techniques , Escherichia coli/isolation & purification , Sound , Antibodies , Arsenicals , Electrodes , Gallium , Gold , Limit of Detection , Regeneration , Zinc Oxide
9.
ACS Omega ; 6(11): 7286-7295, 2021 Mar 23.
Article in English | MEDLINE | ID: mdl-33778243

ABSTRACT

Despite evidence showing that polymer brushes (PBs) are a powerful tool used in biosensing for minimizing nonspecific interactions, allowing for optimization of biosensing performance, and the fact that GaAs semiconductors have proven to have a remarkable potential for sensitive biomolecule detection, the combination of these two robust components has never been considered nor evaluated as a platform for biosensing applications. This work reports different methodologies to prepare and tune PBs on the GaAs interface (PB-GaAs) and their potential as useful platforms for antibody grafting, with the ultimate goal of demonstrating the innovative and attractive character of the PB-GaAs interfaces in the enhanced capture of antibodies and control of nonspecific interactions. Three different functionalization approaches were explored, one "grafting-to" and two "grafting-from," in which atom transfer radical polymerization (ATRP) was performed, followed by their corresponding characterizations. Demonstration of the compatibility of Escherichia coli (E. coli) and Legionella pneumophila (Lp) antibodies with the PB-GaAs platform compared to the results obtained with conventional biosensing architectures developed for GaAs indicates the attractive potential for operation of a sensitive biosensor. Furthermore, these results showed that by carefully choosing the nature and preparation methodology of a PB-GaAs interface, it is possible to effectively tune the affinity of PB-GaAs-based sensors toward E. coli and Lp antibodies ultimately demonstrating the superior specificity of the developed biosensing platform.

10.
ACS Omega ; 6(2): 1299-1308, 2021 Jan 19.
Article in English | MEDLINE | ID: mdl-33490789

ABSTRACT

Culture-based methods for the detection of Legionella pneumophila are prohibitively slow and frequently inadequate. The problem has been addressed with biosensing technology that employs a variety of ligands for the specific capture of bacteria. However, the limited success of the application of mammalian antibodies, aptamers, and nucleic acid-based probes for sensitive biosensing has generated growing interest in exploring alternative biosensing architectures, such as those based on antimicrobial peptides (AMP) that are known for their attractive therapeutic applications. We report on the successful employment of cysteine-modified warnericin RK AMP for the operation of a highly sensitive biosensor of L. pneumophila based on digital photocorrosion of GaAs/AlGaAs nanoheterostructures. The replacement of the relatively cumbersome procedure commonly applied for the attachment of antibodies to COOH-terminated mercaptohexadecanoic acid self-assembled monolayers has allowed for a significant reduction in the distance at which bacteria are immobilized above the biosensor surface. An important consequence of this approach is the attractive limit of detection of L. pneumophila estimated at 2 × 102 CFU/mL. The target bacteria were captured four times more efficiently than P. fluorescens, B. subtilis, and E. coli, which is highly promising for environmental monitoring.

11.
ACS Appl Bio Mater ; 3(1): 477-485, 2020 Jan 21.
Article in English | MEDLINE | ID: mdl-35019464

ABSTRACT

The spontaneous electron transfer between GaAs and ionic gold through the galvanic displacement reaction results in the formation of gold nanoparticles and a Au9Ga4 alloy. We investigated this process for decorating Legionella pneumophila and Escherichia coli, aiming at enhanced imaging of these bacteria. The surface of bacteria was modified with gold ions through the electrostatic linkage of ionic liquids with phosphate units of the bacterial cell wall. The modified bacteria were further incubated with an antibody-functionalized GaAs substrate. Due to a large gap in the reduction potential of gold and gallium ions, the induced reaction involving bacteria resulted in a reduction of the gold ions to gold nanoparticles and oxidation of GaAs to Ga2O3 and a Au9Ga4 alloy. The bacteria covered with a Au/AuGa nanoshell, if excited at 377 nm, show a bright emission at 447 nm originating from Au/Au9Ga4. This approach offers a simple and potentially less expensive method for high-contrast imaging of bacteria in comparison to the conventional methods of staining with different dyes or by conjugating green fluorescent proteins.

12.
ACS Omega ; 4(3): 5829-5838, 2019 Mar 31.
Article in English | MEDLINE | ID: mdl-31001603

ABSTRACT

The development of organic molecules to target nucleic acid is an active area of research at the interface of chemistry and biochemistry, which involves DNA binding, nuclear imaging, and antitumor studies. These molecules bind with DNA through covalent interactions, electrostatic interactions, or intercalation. However, they are less permeable to membrane, and they have a significant cytotoxicity, which limits their application under in vivo conditions. In the present work, various mono- and disubstituted 1,8-naphthalimides-based derivatives (S-12, S-13, S-15, and S-21) have been synthesized and characterized through various spectroscopic techniques. Among these, 3-amino-4-bromo-1,8-naphthalimide (S-15) was found to have an attractive water solubility and act as a nuclear imaging agent. The spectroscopic absorption and emission data showed that S-15 has a strong affinity for salmon sperm DNA with a binding constant of 6.61 × 104 M-1, and the ratiometric fluorescence intensity (I 489/I 552) of S-15 has a linear relationship in the 0-50 µM range of DNA concentrations. It intercalates with DNA through the hydrophobic planar naphthalimide core as confirmed through cyclic voltammetry, circular dichroism, 1H NMR titration, and thermal denaturation studies. Positively charged amine groups also participate in H-bonding with the bases and backbone of DNA. The S-15 intercalator showed a large Stokes shift and photostability, which made it attractive for direct imaging of Legionella pneumophila, without the need for a prior membrane permeabilization.

13.
Langmuir ; 35(13): 4415-4427, 2019 Apr 02.
Article in English | MEDLINE | ID: mdl-29056049

ABSTRACT

We report on the formation kinetics of mixed self-assembled monolayers (SAMs) comprising 16-mercaptohexadecanoic acid (MHDA) and 11-mercapto-1-undecanol (MUDO) thiols on GaAs(100) substrates. These compounds were selected for their potential in constructing highly selective and efficient architectures for biosensing applications. The molecular composition and quality of one-compound and mixed SAMs were determined by the Fourier transform infrared absorption spectroscopy measurements. The formation of enhanced-quality mixed SAMs was investigated as a function of the molecular composition of the thiol mixture and the proportion of ethanol/water solvent used during their arrangement. Furthermore, the formation of mixed SAMs has been carried out by successive immersion of MHDA SAMs in MUDO thiol solutions and MUDO SAMs in MHDA thiol solution through the process involving thiol-thiol substitution. Our results, in addition to confirming that water-ethanol-based solvents improve the packing density of single thiol monolayers, demonstrate the attractive role of water-ethanol solvents in forming superior quality mixed SAMs.

14.
Talanta ; 178: 69-77, 2018 Feb 01.
Article in English | MEDLINE | ID: mdl-29136882

ABSTRACT

Detection of pathogenic bacteria and monitoring their susceptibility to antibiotics are of great importance in the fields of medicine, pharmaceutical research, as well as water and food industries. In order to develop a photonic biosensor for detection of bacteria by taking advantage of photoluminescence (PL) of GaAs-based devices, we have investigated the capture and growth of Escherichia coli K12 on bare and biofunctionalized surfaces of GaAs (001) - a material of interest for capping different semiconductor microstructures. The results were compared with the capture and growth of Escherichia coli K12 on Au surfaces that have commonly been applied for studying a variety of biological and biochemical reactions. We found that neither GaAs nor Au-coated glass wafers placed in Petri dishes inoculated with bacteria inhibited bacterial growth in nutrient agar, regardless of the wafers being bare or biofunctionalized. However, the capture and growth of bacteria on biofunctionalized surfaces of GaAs and Au wafers kept in a flow cell and exposed to different concentrations of bacteria and growth medium revealed that the initial surface coverage and the subsequent bacterial growth were dependent on the biofunctionalization architecture, with antibody-coated surfaces clearly being most efficient in capturing bacteria and offering better conditions for growth of bacteria. We have observed that, as long as the GaAs wafers were exposed to bacterial suspensions at concentrations of at least 105 CFU/mL, bacteria could grow on the surface of wafers, regardless of the type of biofunctionalization architecture used to capture the bacteria. These results provide important insight towards the successful development of GaAs-based devices designed for photonic monitoring of bacterial reactions to different biochemical environments.


Subject(s)
Arsenicals/pharmacology , Culture Techniques/methods , Escherichia coli K12/drug effects , Escherichia coli K12/growth & development , Gallium/pharmacology , Arsenicals/chemistry , Culture Techniques/instrumentation , Gallium/chemistry , Gold/chemistry , Surface Properties
15.
Biosens Bioelectron ; 93: 234-240, 2017 Jul 15.
Article in English | MEDLINE | ID: mdl-27617412

ABSTRACT

Development of quick and reliable methods to investigate antibiotic susceptibility of bacteria is vital to prevent inappropriate and untargeted use of antibiotics and control the antibiotic resistance crisis. The authors have developed an innovative, low-cost and rapid approach to evaluate antibiotic susceptibility of bacteria by employing photoluminescence (PL) emission of photocorroding GaAs/AlGaAs quantum well (QW) biochips. The biochips were functionalized with self-assembled monolayers of biotinylated polyethylene glycol thiols, neutravidin and biotinylated antibodies to immobilize bacteria. The illumination of a QW biochip with the above bandgap radiation leads to formation of surface oxides and dissolution of a limited thickness GaAs cap material (≤10nm) that results in the appearance of a characteristic maximum in the PL plot collected over time. The position of the PL maximum depends on the photocorrosion rate which, in turn, depends on the electric charge immobilized on the surface of the GaAs/AlGaAs biochips. Bacteria captured on the surface of biochips retard the PL maximum, while growth of these bacteria further delays the PL maximum. For the bacteria affected by antibiotics a faster occurring PL maximum, compared with growing bacteria, is observed. By exposing bacteria to nutrient broth and penicillin or ciprofloxacin, the authors were able to distinguish in situ antibiotic-sensitive and resistant Escherichia coli bacteria within less than 3h, considerable more rapid than with culture-based methods. The PL emission of the heterostructures was monitored with an inexpensive reader. This rapid determination of bacterial sensitivity to different antibiotics could have clinical and research applications.


Subject(s)
Biosensing Techniques , Drug Resistance, Bacterial/drug effects , Escherichia coli/isolation & purification , Anti-Bacterial Agents/chemistry , Anti-Bacterial Agents/pharmacology , Arsenicals/chemistry , Escherichia coli/drug effects , Gallium/chemistry , Humans , Luminescence , Microbial Sensitivity Tests , Quantum Dots/chemistry
16.
Biointerphases ; 11(2): 021004, 2016 Jun 20.
Article in English | MEDLINE | ID: mdl-27098616

ABSTRACT

The authors have investigated the effect of chemotaxis on immobilization of bacteria on the surface of biofunctionalized GaAs (001) samples. Escherichia coli K12 bacteria were employed to provide a proof-of-concept of chemotaxis-enhanced bacterial immobilization, and then, these results were confirmed using Legionella pneumophila. The recognition layer was based on a self-assembled monolayer of thiol functionalized with specific antibodies directed toward E. coli or L. pneumophila, together with the enzyme beta-galactosidase (ß-gal). The authors hypothesized that this enzyme together with its substrate lactose would produce a gradient of glucose which would attract bacteria toward the biochip surface. The chemotaxis effect was monitored by comparing the number of bacteria bound to the biochip surface with and without attractant. The authors have observed that ß-gal plus lactose enhanced the immobilization of bacteria on our biochips with a higher effect at low bacterial concentrations. At 100 and 10 bacteria/ml, respectively, for E. coli and L. pneumophila, the authors observed up to 11 and 8 times more bacteria bound to biochip surfaces assisted with the chemotaxis effect in comparison to biochips without chemotaxis. At 10(4) bacteria/ml, the immobilization enhancement rate did not exceed two times.


Subject(s)
Arsenicals , Bacterial Adhesion , Cells, Immobilized/physiology , Chemotaxis , Escherichia coli K12/physiology , Gallium , Legionella pneumophila/physiology , Antibodies, Bacterial/metabolism , Enzymes, Immobilized/metabolism , Escherichia coli K12/drug effects , Glucose/metabolism , Legionella pneumophila/drug effects , beta-Galactosidase/metabolism
17.
Biointerphases ; 11(1): 019301, 2016 Mar 22.
Article in English | MEDLINE | ID: mdl-26903310

ABSTRACT

Photocorrosion of semiconductors is strongly sensitive to the presence of surface states, and it could be influenced by electrically charged molecules immobilized near the semiconductor/electrolyte interface. The underlying mechanism is related to band bending of the semiconductor structure near the surface and the associated distribution of excited electrons and holes. The authors have employed photoluminescence of GaAs/AlGaAs quantum heterostructures for monitoring in situ the photocorrosion effect, and demonstrating detection of nongrowing Legionella pneumophila suspended in phosphate buffered saline solution. Antibody functionalized samples allowed direct detection of these bacteria at 10(4) bacteria/ml. The authors discuss the sensitivity of the process related to the ability of creating conditions suitable for photocorrosion proceeding at extremely slow rates and the interaction of an electric charge of bacteria with the surface of a biofunctionalized semiconductor.


Subject(s)
Biosensing Techniques/methods , Legionella pneumophila/isolation & purification , Optics and Photonics/methods , Luminescent Measurements , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...