Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 41
Filter
1.
Article in English | MEDLINE | ID: mdl-38253974

ABSTRACT

OBJECTIVE: Considering the controversial benefits of video-assisted thoracoscopic surgery (VATS), we intended to evaluate the impact of surgical approach on cardiac function after lung resection using myocardial work analysis. METHODS: Echocardiographic data of 48 patients (25 thoracotomy vs. 23 VATS) were retrospectively analyzed. All patients underwent transthoracic echocardiography (TTE) within 2 weeks before and after surgery, including two-dimensional speckle tracking and tissue Doppler imaging. RESULTS: No notable changes in left ventricular (LV) function, assessed mainly using the LV global longitudinal strain (GLS), global myocardial work index (GMWI), and global work efficiency (GWE), were observed. Right ventricular (RV) TTE values, including tricuspid annular plane systolic excursion (TAPSE), tricuspid annular systolic velocity (TASV), right ventricular global longitudinal strain (RVGLS), and RV free-wall GLS (RVFWGLS), indicated greater RV function impairment in the thoracotomy group than in the VATS group [TAPSE(mm) 17.90 ± 3.80 vs. 21.00 ± 3.48, p = 0.006; d = 0.84; TASV(cm/s): 12.40 ± 2.90 vs. 14.70 ± 2.40, p = 0.004, d = 0.86; RVGLS(%): - 16.00 ± 4.50 vs. - 19.40 ± 2.30, p = 0.012, d = 0.20; RVFWGLS(%): - 11.50 ± 8.50 vs. - 18.31 ± 5.40, p = 0.009, d = 0.59; respectively]. CONCLUSIONS: Unlike RV function, LV function remained preserved after lung resection. The thoracotomy group exhibited greater RV function impairment than did the VATS group. Further studies should evaluate the long-term impact of surgical approach on cardiac function.

2.
Ultrasonography ; 41(2): 403-415, 2022 Apr.
Article in English | MEDLINE | ID: mdl-34749444

ABSTRACT

A reliable method of measuring diaphragmatic function at the bedside is still lacking. Widely used two-dimensional (2D) ultrasonographic measurements, such as diaphragm excursion, diaphragm thickness, and fractional thickening (FT) have failed to show clear correlations with diaphragmatic function. A reason for this is that 2D ultrasonographic measurements, like FT, are merely able to measure the deformation of muscular diaphragmatic tissue in the transverse direction, while longitudinal measurements in the direction of contracting muscle fibres are not possible. Speckle tracking ultrasonography, which is widely used in cardiac imaging, overcomes this disadvantage and allows observations of movement in the direction of the contracting muscle fibres, approximating muscle deformation and the deformation velocity. Several studies have evaluated speckle tracking as a promising method to assess diaphragm contractility in healthy subjects. This technical note demonstrates the feasibility of speckle tracking ultrasonography of the diaphragm in a group of 20 patients after an aortocoronary bypass graft procedure. The results presented herein suggest that speckle tracking ultrasonography is able to depict alterations in diaphragmatic function after surgery better than 2D ultrasonographic measurements.

3.
J Clin Med ; 10(22)2021 Nov 15.
Article in English | MEDLINE | ID: mdl-34830578

ABSTRACT

Aortopathy is a known complication whose incidence is growing within the population of tetralogy of Fallot (TOF) patients. Its pathology and relationship with other comorbidities remain unclear. This study was designed to determine the prevalence and predictors of proximal aortic dilatation after TOF repair. We retrospectively investigated all patients who underwent follow-up cardiac magnetic resonance imaging (CMR; at least 4 years after TOF repair) between March 2004 and December 2019. The dimensions at the ascending aorta (AAo) and sinus of Valsalva (SoV) levels were measured. Aortic dilatation was defined as an internal aortic diameter that was >2 standard deviation of the previously published normal values. We included 77 patients (mean age 28.9 ± 10.5 years, 41.5% female, mean follow-up of 24.5 ± 8.1 years). AAo and SoV were dilated in 19 (24.6%) and 43 (55.8%) patients, respectively. Patients with dilated AAo and SoV were older during the corrective surgery (p < 0.001 and p = 0.004, respectively) and during CMR (p = 0.002 and 0.024, respectively) than patients without AAo and SoV dilatation. Patients of the dilated AAo group were more likely to have prior palliative shunt (p = 0.008), longer shunt duration (p = 0.005), and a higher degree of aortic valve regurgitation (AR) fraction (p < 0.001) and to undergo pulmonary (PVR) and/or aortic valve replacement (p < 0.001 and p = 0.013, respectively). PVR (p = 0.048, odds ratio = 6.413, and 95% CI = 1.013-40.619) and higher AR fraction (p = 0.031, odds ratio = 1.194, and 95% CI = 1.017-1.403) were independent predictors for AAo dilatation. Aortopathy is a common progressive complication that may require reintervention and lifelong follow-up. Our study shows that proximal aortic dilatation may be attributed to factors that increase the volume overload across the proximal aorta, including late corrective surgery and palliative shunt. We also found that PVR and higher AR fraction are independent predictors of AAo dilatation.

4.
J Clin Med ; 10(12)2021 Jun 09.
Article in English | MEDLINE | ID: mdl-34207573

ABSTRACT

It remains unclear to what extent the outcomes and complications of extracorporeal membrane oxygenation (ECMO) therapy in COVID-19 patients with acute respiratory distress syndrome (ARDS) differ from non-COVID-19 ARDS patients. In an observational, propensity-matched study, outcomes after ECMO support were compared between 19 COVID-19 patients suffering from ARDS (COVID group) and 34 matched non-COVID-19 ARDS patients (NCOVID group) from our historical cohort. A 1:2 propensity matching was performed based on respiratory ECMO survival prediction (RESP) score, age, gender, bilirubin, and creatinine levels. Patients' characteristics, laboratory parameters, adverse events, and 90-day survival were analyzed. Patients' characteristics in COVID and NCOVID groups were similar. Before ECMO initiation, fibrinogen levels were significantly higher in the COVID group (median: 493 vs. 364 mg/dL, p < 0.001). Median ECMO support duration was similar (16 vs. 13 days, p = 0.714, respectively). During ECMO therapy, patients in the COVID group developed significantly more thromboembolic events (TEE) than did those in the NCOVID group (42% vs. 12%, p = 0.031), which were mainly pulmonary artery embolism (PAE) (26% vs. 0%, p = 0.008). The rate of major bleeding events (42% vs. 62%, p = 0.263) was similar. Fibrinogen decreased significantly more in the COVID group than in the NCOVID group (p < 0.001), whereas D-dimer increased in the COVID group (p = 0.011). Additionally, 90-day mortality did not differ (47% vs. 74%; p = 0.064) between COVID and NCOVID groups. Compared with that in non-COVID-19 ARDS patients, ECMO support in COVID-19 patients was associated with comparable in-hospital mortality and similar bleeding rates but a higher incidence of TEE, especially PAE. In contrast, coagulation parameters differed between COVID and NCOVID patients.

5.
BMC Cardiovasc Disord ; 21(1): 189, 2021 04 17.
Article in English | MEDLINE | ID: mdl-33865330

ABSTRACT

BACKGROUND: Resuscitation using a percutaneous mechanical circulatory support device (iCPR) improves survival after cardiac arrest (CA). We hypothesized that the addition of inhaled nitric oxide (iNO) during iCPR might prove synergistic, leading to improved myocardial performance due to lowering of right ventricular (RV) afterload, left ventricular (LV) preload, and myocardial energetics. This study aimed to characterize the changes in LV and RV function and global myocardial work indices (GWI) following iCPR, both with and without iNO, using 2-D transesophageal echocardiography (TEE) and GWI evaluation as a novel non-invasive measurement. METHODS: In 10 pigs, iCPR was initiated following electrically-induced CA and 10 min of untreated ventricular fibrillation (VF). Pigs were randomized to either 20 ppm (20 ppm, n = 5) or 0 ppm (0 ppm, n = 5) of iNO in addition to therapeutic hypothermia for 5 h following ROSC. All animals received TEE at five pre-specified time-points and invasive hemodynamic monitoring. RESULTS: LV end-diastolic volume (LVEDV) increased significantly in both groups following CA. iCPR alone led to significant LV unloading at 5 h post-ROSC with LVEDV values reaching baseline values in both groups (20 ppm: 68.2 ± 2.7 vs. 70.8 ± 6.1 mL, p = 0.486; 0 ppm: 70.8 ± 1.3 vs. 72.3 ± 4.2 mL, p = 0.813, respectively). LV global longitudinal strain (GLS) increased in both groups following CA. LV-GLS recovered significantly better in the 20 ppm group at 5 h post-ROSC (20 ppm: - 18 ± 3% vs. 0 ppm: - 13 ± 2%, p = 0.025). LV-GWI decreased in both groups after CA with no difference between the groups. Within 0 ppm group, LV-GWI decreased significantly at 5 h post-ROSC compared to baseline (1,125 ± 214 vs. 1,835 ± 305 mmHg%, p = 0.011). RV-GWI was higher in the 20 ppm group at 3 h and 5 h post-ROSC (20 ppm: 189 ± 43 vs. 0 ppm: 108 ± 22 mmHg%, p = 0.049 and 20 ppm: 261 ± 54 vs. 0 ppm: 152 ± 42 mmHg%, p = 0.041). The blood flow calculated by the Impella controller following iCPR initiation correlated well with the pulsed-wave Doppler (PWD) derived pulmonary flow (PWD vs. controller: 1.8 ± 0.2 vs. 1.9 ± 0.2L/min, r = 0.85, p = 0.012). CONCLUSIONS: iCPR after CA provided sufficient unloading and preservation of the LV systolic function by improving LV-GWI recovery. The addition of iNO to iCPR enabled better preservation of the RV-function as determined by better RV-GWI. Additionally, Impella-derived flow provided an accurate measure of total flow during iCPR.


Subject(s)
Cardiotonic Agents/administration & dosage , Echocardiography, Doppler, Pulsed , Echocardiography, Transesophageal , Heart Arrest/therapy , Heart-Assist Devices , Nitric Oxide/administration & dosage , Resuscitation/instrumentation , Ventricular Function, Left/drug effects , Administration, Inhalation , Animals , Disease Models, Animal , Female , Heart Arrest/diagnostic imaging , Heart Arrest/physiopathology , Recovery of Function , Sus scrofa , Ventricular Function, Right/drug effects
6.
Int J Clin Pharm ; 43(4): 825-838, 2021 Aug.
Article in English | MEDLINE | ID: mdl-33774764

ABSTRACT

Background Argatroban, lepirudin, desirudin, bivalirudin, and danaparoid are commonly used to manage heparin-induced thrombocytopenia related complications. However, the most suitable drug for this condition still remains controversial. Aim of the review This Bayesian network meta-analysis study compared the most common anticoagulant drugs used in the management of heparin-induced thrombocytopenia. Method All clinical trials comparing two or more anticoagulant therapies for suspected or confirmed heparin-induced thrombocytopenia were considered for inclusion. Studies concerning the use of heparins or oral anticoagulants were not considered. Data concerning hospitalisation length, thromboembolic, major, and minor haemorrhagic events, and mortality rate were collected. The network analyses were made through the STATA routine for Bayesian hierarchical random-effects model analysis with standardised mean difference (SMD) and log odd ratio (LOR) effect measures. Results Data from a total of 4338 patients were analysed. The overall mean age was 62.31 ± 6.6 years old. Hospitalization length was considerably shorter in favour of the argatroban group (SMD: - 1.70). Argatroban evidenced the lowest rate of major (LOR: - 1.51) and minor (LOR: - 0.57) haemorrhagic events. Argatroban demonstrated the lowest rate of thromboembolic events (LOR: 0.62), and mortality rate (LOR: - 1.16). Conclusion Argatroban performed better overall for selected patients with HIT. Argatroban demonstrated the shortest hospitalization, and lowest rate of haemorrhages, thromboembolisms, and mortality compared to bivalirudin, lepirudin, desirudin, and danaparoid.


Subject(s)
Pipecolic Acids , Thrombocytopenia , Anticoagulants/adverse effects , Arginine/analogs & derivatives , Bayes Theorem , Heparin/adverse effects , Humans , Middle Aged , Network Meta-Analysis , Pipecolic Acids/therapeutic use , Sulfonamides , Thrombocytopenia/chemically induced , Thrombocytopenia/drug therapy
7.
Int J Cardiovasc Imaging ; 37(3): 835-846, 2021 Mar.
Article in English | MEDLINE | ID: mdl-33048268

ABSTRACT

This study aimed to determine standard left (LV) and right ventricular (RV) transesophageal echocardiographic (TEE) measurements in swine. Additionally, global myocardial work index (GWI) was estimated using pressure-strain loops (PSL). A comprehensive TEE examination was conducted in ten anesthetized, intubated and mechanically ventilated healthy female German landrace swine, weighing 44 to 57 kg. For GWI calculation, we performed LV and RV segmental strain analysis and used invasively measured LV and RV pressure to obtain PSL. The GWI and further myocardial work indices were calculated from the area of the PSL using commercially available software. Furthermore, hemodynamic measurements were obtained using indwelling catheters. We obtained complete standardized baseline values for left and right ventricular dimensions and function. Biplane LV ejection fraction was 63 ± 7 % and the LV end-diastolic volume was 70.5 ± 5.9 ml. Tissue Doppler estimated peak tricuspid annular systolic velocity was 13.1 ± 1.8 cm/s. The Doppler estimated LV and RV stroke volume index were 75.6 ± 7.2 ml/m2 and 76.7 ± 7.8 ml/m2 respectively. Pulsed wave Doppler derived cardiac output correlated well with cardiac output estimated using the thermodilution method (7.0 ± 1.2 l/min vs. 7.0 ± 1.1 l/min, r = 0.812, p = 0.004). The LV global longitudinal strain was -21.3 ± 3.9 % and the RV global longitudinal strain was -15.4 ± 2.5 %. LV GWI was 1885(1281-2121) mmHg*% and 297 ± 62 mmHg*% for the RV. LV global myocardial work efficiency was 82.6 ± 4 % and 83(72-88) % for the RV. TEE offers sufficient morphological, functional and hemodynamic assessment of the heart in swine. Myocardial contractility and mechanics can be reliably evaluated with the non-invasive GWI derived from echocardiography without additional invasive measures.


Subject(s)
Echocardiography, Doppler , Echocardiography, Transesophageal , Heart Ventricles/diagnostic imaging , Myocardial Contraction , Ventricular Function, Left , Ventricular Function, Right , Animals , Feasibility Studies , Female , Hemodynamic Monitoring , Hemodynamics , Models, Animal , Predictive Value of Tests , Reproducibility of Results , Sus scrofa
8.
Int J Clin Pharm ; 43(3): 449-460, 2021 Jun.
Article in English | MEDLINE | ID: mdl-33044680

ABSTRACT

Background  Little is known with regards to the prognostic factors for patients with suspected or diagnosed Heparin-Induced Thromobocytopenia (HIT). The role of patient and therapy characteristics may play a role in predicting the outcome. Aim of the review To investigate the role of patient and therapy characteristics as potential prognostic factors for HIT-related complications (haemorrhagic and thromboembolic events), and mortality. Method The present systematic review was conducted according to the PRISMA statement. In September 2020, the main online databases were accessed: Pubmed, EMBASE, Scopus, Google Scholar. All the clinical trials concerning the management of patients with suspected or confirmed HIT were eligible. Studies evaluating the use of oral anticoagulants (e.g. vitamin K antagonists, Apixaban) were not considered, along with those comparing the use of heparin. For pairwise correlation, the Pearson Product-Moment Correlation Coefficient (r) was used. The final effect was evaluated according to the Cauchy-Schwarz inequality.Results Data from 33 clinical studies (4338 patients) were retrieved. The overall mean age was 62.3 ± 6.6 years old. Patients with HIT-related thromboembolism at the moment of diagnosis were associated with greater rate of haemorrhages (P > 0.0001), thromboembolism (P > 0.0001) and mortality (P = 0.001). Patients with more comorbidities at diagnosis were associated with a greater risk of haemorrhages (P = 0.07), thromboembolism (P = 0.002) and mortality (P = 0.002). Patients with longer duration of the therapy were associated with lower rate of mortality (P = 0.04). ConclusionsPatient comorbidities, presence of HIT-related thromboembolism on admission and shorter anticoagulant therapy were found to be negative prognostic factors. Thrombocythemia on admission, patients age and gender did not influence the overall outcome.


Subject(s)
Thrombocytopenia , Thromboembolism , Aged , Anticoagulants/adverse effects , Heparin/adverse effects , Humans , Middle Aged , Prognosis , Thrombocytopenia/chemically induced , Thrombocytopenia/diagnosis , Thrombocytopenia/epidemiology
9.
Ann Thorac Cardiovasc Surg ; 26(5): 276-285, 2020 Oct 21.
Article in English | MEDLINE | ID: mdl-32893224

ABSTRACT

PURPOSE: Benefits of off-pump coronary bypass (OPCAB) over on-pump (ONCAB) remain controversial. We aimed to evaluate the early impacts of OPCAB vs ONCAB for varying left ventricular (LV) function baselines by applying the non-invasive myocardial work (MW) analysis, which enables further insights in cardiac mechanics, contractility, and efficacy. METHODS: We retrospectively analyzed 98 patients (55 ONCAB vs 43 OPCAB). Transthoracic echocardiography (TTE) and concurrent arterial blood pressure measurements taken at rest, prior to, and early after surgery were performed. Global myocardial work index (GMWI), global constructive work (GCW), and global work efficiency (GWE), inter alia, were quantified. RESULTS: Preoperatively, OPCAB patients had significantly lower values than ONCAB patients in terms of GMWI (1404.33 ± 585.41 mmHg% vs 1619.07 ± 535.42 mmHg%, p = 0.039), GWE (90% (60%, 96%) vs 93% (74%, 98%), p = 0.028). After surgery, GMWI was reduced in both groups. However, a more significant GMWI impairment occurred early after ONCAB than after OPCAB (-343.14 ± 35.20 mmHg%, p <0.001 vs -224.04 ± 120.91 mmHg%, p = 0.042). CONCLUSION: Despite lower preoperative LV function in OPCAB patients, GMWIs after OPCAB were superior to ONCAB, indicating better preservation of systolic LV function early after OPCAB by means of contractility compared to ONCAB. Further studies should investigate the long-term course of MW response and their clinical impact.


Subject(s)
Cardiopulmonary Bypass , Coronary Artery Bypass, Off-Pump , Coronary Artery Bypass , Coronary Artery Disease/surgery , Myocardial Contraction , Ventricular Function, Left , Aged , Cardiopulmonary Bypass/adverse effects , Coronary Artery Bypass/adverse effects , Coronary Artery Bypass, Off-Pump/adverse effects , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/physiopathology , Female , Humans , Male , Middle Aged , Retrospective Studies , Treatment Outcome , Ventricular Dysfunction, Left/etiology , Ventricular Dysfunction, Left/physiopathology
10.
Eur Surg Res ; 60(5-6): 229-238, 2019.
Article in English | MEDLINE | ID: mdl-31743901

ABSTRACT

INTRODUCTION: Right ventricular failure (RVF) on its own is a life-threatening condition. Often it manifests as a two-organ failure in the final phase of several lung diseases. Mechanical circulatory support is a proven treatment of RVF but remains challenging. Our objective is to develop a novel, simplified, and minimally invasive cannula approach to treat both RVF and respiratory failure. METHODS: We conceptualized a dual lumen cannula approach to allow oxygenated right-to-left shunting at an atrial level to decompress right-sided circulation. A minimally invasive approach through percutaneous, transjugular insertion and transseptal placement should enable patients to be non-sedated and even ambulatory. In an iterative design, pre-prototyping, prototyping, and anatomic fitting process, such a cannula was generated and tested in both cadaveric and fluid dynamic studies. RESULTS: After various modifications and improvements, a 27-Fr 255-mm-long double-lumen cannula with an inner line (oxygenated blood return to patient into the left atrium) of 18 Fr and an inflatable balloon (with a volume of approximately 1 mL) at the outflow tip was produced - one version with a straight head and another one with a curved head. In our anatomic studies, the "Aachen Cannula" allowed an easy transjugular introduction and advancement into the right atrium by Seldinger technique. Transseptal placement was achieved by puncture (Brockenbrough needle) in combination with dilatation and was then secured in place with the stabilizing balloon, even under slight tension. The cannula prototype enabled a flow of up to 3.5 L/min, at which common pressure drops were observed. CONCLUSION: In conclusion, we successfully conceptualized, designed, and verified a minimally invasive one-cannula approach for the treatment of either isolated right heart failure and even combined RVF and respiratory failure through our transseptal Aachen Cannula. This concept may also be carried out in ambulatory conditions. Moreover, this approach completely avoids recirculation issues and ensures reliable oxygenated coronary as well as cerebral perfusion.


Subject(s)
Heart Failure/surgery , Respiratory Insufficiency/surgery , Cannula , Extracorporeal Membrane Oxygenation , Heart Ventricles , Humans , Hydrodynamics
11.
Artif Organs ; 43(3): 242-253, 2019 Mar.
Article in English | MEDLINE | ID: mdl-30040134

ABSTRACT

Noninvasive measurements of blood pressure (BP) and cardiac output (CO) are crucial in the follow-up of continuous-flow left ventricular assist device (CF-LVAD) patients. For our pilot study, we sought to compare BP measurements between a tonometry blood pressure pulse analyzer (BPPA) (DMP-Life, DAEYOMEDI Co., Ltd., Gyeonggi-do, South Korea) and Doppler ultrasound in CF-LVAD patients, as well as to compare the BPPA estimated CO to LVAD calculated blood flow and to the patient's intrinsic CO estimated with transthoracic echocardiography (TTE). Ambulatory CF-LVAD patients (6 HeartMate, 26 HeartMate II), were included. According to TTE findings, patients were then subdivided in two groups: patients with an opening aortic valve (OAV) [n = 21] and those with an intermittent opening aortic valve (IOAV) [n = 11]. We found a very good correlation of systolic BP (SBP) measurements between the two methods, BPPA and Doppler ultrasound (r = 0.87, P < 0.0001). Bland-Altman plots for SBP revealed a low bias of -4.6 mm Hg and SD of ±4.7 mm Hg. In CF-LVAD patients with IOAV, the BPPA-CO had a good correlation with the LVAD-flow (r = 0.78, P < 0.0001), but in OAV patients, there was no correlation. After adding the patient's intrinsic CO, estimated from TTE in patients with OAV to the LVAD-flow, we found a very good correlation between the BPPA-CO and LVAD-flow + TTE-CO (r = 0.81, P = 0.002). Our study demonstrated that compared with the standard clinical method, Doppler ultrasound, the BPPA measured BP noninvasively with good accuracy and precision of agreement. In addition, tonometry BPPA provided further valuable information regarding the CF-LVAD patient's intrinsic CO.


Subject(s)
Blood Pressure Determination/methods , Heart Failure/surgery , Heart-Assist Devices , Aftercare/methods , Aged , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Cardiac Output/physiology , Echocardiography/methods , Echocardiography, Doppler/methods , Female , Heart Failure/diagnostic imaging , Heart Failure/physiopathology , Humans , Male , Manometry/instrumentation , Manometry/methods , Middle Aged , Pilot Projects , Radial Artery , Stroke Volume/physiology , Ventricular Function, Left
12.
Ann Thorac Cardiovasc Surg ; 24(5): 238-246, 2018 Oct 19.
Article in English | MEDLINE | ID: mdl-29877218

ABSTRACT

PURPOSE: To assess whether thoracic non-cardiac surgery has an influence on right ventricular function (RVF) compared to known impaired postoperative RV function after cardiac surgery. METHODS: In all, 50 patients (mean age: 61 years), who underwent thoracic non-cardiac surgery were included and matched using propensity score to 50 patients, receiving coronary artery bypass graft surgery (CABG) (CABGmatched). All patients had transthoracic echocardiography (TTE) including two-dimensional speckle tracking (2D-STE) and tissue Doppler imaging (TDI) pre- and 1 week postoperatively. RESULTS: No significant changes in RV measurements including tricuspid annular plane systolic excursion (TAPSE), tricuspid annular systolic velocity (TASV), RV fractional area change (RV-FAC), and 2D-STE of the RV and RV freewall within the thoracic non-cardiac surgery patients comparing pre- and postoperative values. Comparing RV TTE values between CABGmatched patients and thoracic surgery patients, only TAPSE differed between groups preoperatively (p <0.0001), where postoperatively, all RV measurements differed significantly between the two groups: TAPSE (p <0.0001), TASV (p <0.001), RVFAC (p = 0.005), and RV 2D-STE (p <0.0001) indicating impairment of RV function post-CABG surgery compared to thoracic non-cardiac surgery. CONCLUSION: Thoracic non-cardiac surgery including an opening of the pleural cavity did not influence RV function early postoperative, whereas CABG surgery with pericardiotomy led to an impaired global RV function.


Subject(s)
Coronary Artery Bypass/adverse effects , Echocardiography, Doppler , Thoracic Surgery, Video-Assisted/adverse effects , Thoracotomy/adverse effects , Ventricular Dysfunction, Right/diagnostic imaging , Ventricular Function, Right , Adult , Aged , Female , Humans , Male , Middle Aged , Pericardiectomy/adverse effects , Predictive Value of Tests , Propensity Score , Retrospective Studies , Risk Factors , Systole , Time Factors , Treatment Outcome , Ventricular Dysfunction, Right/etiology , Ventricular Dysfunction, Right/physiopathology
13.
Interact Cardiovasc Thorac Surg ; 27(5): 664-670, 2018 11 01.
Article in English | MEDLINE | ID: mdl-29788476

ABSTRACT

OBJECTIVES: Sutureless aortic valve prostheses are gaining popularity due to the substantial reduction in cross-clamp time. In this study, we report our observations on the cusp-fluttering phenomenon of the Perceval bioprosthesis (LivaNova, London, UK) using a combination of technical and medical perspectives. METHODS: Between August 2014 and December 2016, a total of 108 patients (69% women) with a mean age of 78 years had aortic valve replacement using the Perceval bioprosthesis (34 combined procedures). All patients underwent transoesophageal echocardiography (TOE) intraoperatively. TOE was performed postoperatively to detect paravalvular leakage and to measure gradients, acceleration time, Doppler velocity indices (Vmax and LVOT/Vmax AV) and effective orifice area indices. In addition, a TOE examination was performed in 21 patients postoperatively. Data were collected retrospectively from our hospital database. RESULTS: The retrospective evaluation of the intraoperative TOE examinations revealed consistent fluttering in all patients with the Perceval bioprosthesis. The echocardiographic postoperative measurements showed a mean effective orifice area index of 0.91 ± 0.12 cm2/m2. The overall mean pressure and peak pressure gradients were in a higher range (13.5 ± 5.1 mmHg and 25.5 ± 8.6 mmHg, respectively), whereas acceleration time (62.8 ± 16.4 ms) and Doppler velocity indices (0.43 ± 0.11) were within the normal range according to the American Society of Echocardiography or european association of echocardiography (EAE) guidelines. The 2-dimensional TOE in Motion Mode (M-Mode) that was performed in patients with elevated lactate dehydrogenase (LDH) levels revealed remarkable fluttering of the cusps of the Perceval bioprosthesis. CONCLUSIONS: In our study cohort, we observed the fluttering phenomenon in all patients who received the Perceval bioprosthesis, which was correlated with elevated LDH levels and higher pressure gradients.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Bioprosthesis , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis , Aged , Aortic Valve/diagnostic imaging , Aortic Valve Stenosis/diagnosis , Echocardiography , Female , Humans , Male , Postoperative Period , Prosthesis Design , Retrospective Studies
15.
PeerJ ; 5: e4132, 2017.
Article in English | MEDLINE | ID: mdl-29230366

ABSTRACT

BACKGROUND: Bedside non-invasive techniques, such as radial artery tonometry, to estimate hemodynamic parameters have gained increased relevance as an attractive alternative and efficient method to measure hemodynamics in outpatient departments. For our pilot study, we sought to compare cardiac output (CO), and stroke volume (SV) estimated from a radial artery tonometry blood pressure pulse analyzer (BPPA) (DMP-Life, DAEYOMEDI Co., Gyeonggi-do, South Korea) to pulsed-wave Doppler (PWD) echocardiography derived parameters. METHODS: From January 2015 to December 2016, all patients scheduled for coronary artery bypass (CABG) surgery at our department were screened. Exclusion criteria were, inter alia, moderate to severe aortic- or Mitral valve disease and peripheral arterial disease (PAD) > stage II. One hundred and seven patients were included (mean age 66.1 ± 9.9, 15 females, mean BMI 27.2 ± 4.1 kg/m2). All patients had pre-operative transthoracic echocardiography (TTE). We measured the hemodynamic parameters with the BPPA from the radial artery, randomly before or after TTE. For the comparison between the measurement methods we used the Bland-Altman test and Pearson correlation. RESULTS: Mean TTE-CO was 5.1 ± 0.96 L/min, and the mean BPPA-CO was 5.2 ± 0.85 L/min. The Bland-Altman analysis for CO revealed a bias of -0.13 L/min and SD of 0.90 L/min with upper and lower limits of agreement of -1.91 and +1.64 L/min. The correlation of CO measurements between DMP-life and TTE was poor (r = 0.501, p < 0.0001). The mean TTE-SV was 71.3 ± 16.2 mL and the mean BPPA-SV was 73.8 ± 19.2 mL. SV measurements correlated very well between the two methods (r = 0.900, p < 0.0001). The Bland-Altman analysis for SV revealed a bias of -2.54 mL and SD of ±8.42 mL and upper and lower limits of agreement of -19.05 and +13.96 mL, respectively. CONCLUSION: Our study shows for the first time that the DMP-life tonometry device measures SV and CO with reasonable accuracy and precision of agreement compared with TTE in preoperative cardiothoracic surgery patients. Tonometry BPPA are relatively quick and simple measuring devices, which facilitate the collection of cardiac and hemodynamic information. Further studies with a larger number of patients and with repeated measurements are in progress to test the reliability and repeatability of DMP-Life system.

16.
Eur J Cardiothorac Surg ; 52(6): 1069-1076, 2017 Dec 01.
Article in English | MEDLINE | ID: mdl-28481994

ABSTRACT

OBJECTIVES: Right heart failure (RHF) after the implantation of a left ventricular assist device (LVAD) remains a dreaded postoperative complication. Using 2D speckle-tracking echocardiography, it is possible to acquire right ventricular global and regional function. The aim of our study was to assess whether speckle-tracking echocardiography values will better predict the RHF post-continuous-flow LVAD implantation. METHODS: From January 2014 to January 2016, 54 patients who underwent LVAD implantation were included and retrospectively analysed. Clinical, invasive haemodynamic (right and left heart catheterization), laboratory and transthoracic echocardiography data were reviewed. Multivariable logistic regression was performed using RHF as dependent variable. RESULTS: Thirteen patients (24%) developed RHF. These patients had significantly elevated procalcitonin (P = 0.011), elevated central venous pressure (CVP) pre- and post-LVAD implantation (P = 0.002 and 0.031, respectively), higher right ventricular (RV) and pulmonary systolic pressure (P = 0.016 and 0.013, respectively), higher Michigan Risk Score (P = 0.001) and a lower peak systolic longitudinal strain of the basal RV free wall (P = 0.032). Haemoglobin, procalcitonin, RV systolic pressure, basal right ventricular free wall and pre-CVP entered the final multivariable analysis, only basal right ventricular free wall (P < 0.001) and pre-CVP (P < 0.001) remained significant predictors of RHF. The sensitivity and specificity of the final model were 85.7% and 95.4%, respectively. The negative predictive value reached 94%. CONCLUSIONS: 2D strain parameters of the RV free wall seem to be auspicious for RV function and predicting RHF. Moreover, intraoperative CVP should not be neglected since elevated values proved to be highly associated with RHF. Our results represent a valuable supplement to other scores by considering both echocardiography and intraoperative data.


Subject(s)
Echocardiography/methods , Heart Failure/diagnosis , Heart Ventricles/diagnostic imaging , Heart-Assist Devices/adverse effects , Postoperative Complications/diagnosis , Ventricular Function, Right/physiology , Disease Progression , Female , Follow-Up Studies , Germany/epidemiology , Heart Failure/epidemiology , Heart Failure/etiology , Heart Ventricles/physiopathology , Humans , Incidence , Male , Middle Aged , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Retrospective Studies
17.
J Appl Physiol (1985) ; 123(5): 1063-1070, 2017 Nov 01.
Article in English | MEDLINE | ID: mdl-28522757

ABSTRACT

Assessment of diaphragmatic effort is challenging, especially in critically ill patients in the phase of weaning. Fractional thickening during inspiration assessed by ultrasound has been used to estimate diaphragm effort. It is unknown whether more sophisticated ultrasound techniques such as speckle tracking are superior in the quantification of inspiratory effort. This study evaluates the validity of speckle tracking ultrasound to quantify diaphragm contractility. Thirteen healthy volunteers underwent a randomized stepwise threshold loading protocol of 0-50% of the maximal inspiratory pressure. Electric activity of the diaphragm and transdiaphragmatic pressures were recorded. Speckle tracking ultrasound was used to assess strain and strain rate as measures of diaphragm tissue deformation and deformation velocity, respectively. Fractional thickening was assessed by measurement of diaphragm thickness at end-inspiration and end-expiration. Strain and strain rate increased with progressive loading of the diaphragm. Both strain and strain rate were highly correlated to transdiaphragmatic pressure (strain r2 = 0.72; strain rate r2 = 0.80) and diaphragm electric activity (strain r2 = 0.60; strain rate r2 = 0.66). We conclude that speckle tracking ultrasound is superior to conventional ultrasound techniques to estimate diaphragm contractility under inspiratory threshold loading.NEW & NOTEWORTHY Transdiaphragmatic pressure using esophageal and gastric balloons is the gold standard to assess diaphragm effort. However, this technique is invasive and requires expertise, and the interpretation may be complex. We report that speckle tracking ultrasound can be used to detect stepwise increases in diaphragmatic effort. Strain and strain rate were highly correlated with transdiaphragmatic pressure, and therefore, diaphragm electric activity and speckle tracking might serve as reliable tools to quantify diaphragm effort in the future.


Subject(s)
Diaphragm/diagnostic imaging , Diaphragm/physiology , Inhalation , Muscle Contraction , Ultrasonography/methods , Biomechanical Phenomena , Female , Healthy Volunteers , Humans , Male , Predictive Value of Tests , Pressure , Reproducibility of Results , Stress, Mechanical , Time Factors , Young Adult
18.
Interact Cardiovasc Thorac Surg ; 24(3): 355-362, 2017 03 01.
Article in English | MEDLINE | ID: mdl-28025312

ABSTRACT

Objectives: In patients with a small aortic annulus, aortic valve replacement (AVR) is frequently associated with high residual pressure gradients. Supra-annular pericardial aortic prostheses are gaining popularity due to the increased effective orifice areas (EOA) and resulting lower gradients. This study reports the clinical and echocardiographic results following implantation of the new supra-annular pericardial aortic prosthesis Dokimos Plus (Labcor, Belo Horizonte, Brazil). Methods: Between October 2013 and July 2015, 137 patients (41% women, mean age: 74 years) underwent supra-annular AVR with or without concomitant procedures using the Dokimos Plus prosthesis in our department. Transthoracic echocardiography was performed pre- and postoperatively on all patients to assess haemodynamic parameters (gradients, acceleration time [AT], Doppler velocity indices [DVIs] and indexed EOA [EOAI]) and to detect paravalvular leakage (PVL). Data were collected retrospectively from our hospital databases. Methods: Patients were grouped by prosthesis size: Most patients received 23-mm (57.6%), followed by 21-mm (19%), 25-mm (15.4%) and 27-mm (8%) prostheses. The mean EOAI in all groups was 1.1 ± 0.26 cm 2 /m 2 . Pressure gradients were low in all groups (mean: 8.9 ± 4.4 mmHg; peak: 18.8 ± 6.8 mmHg); AT and DVI were in the normal range according to American Society of Echocardiography/European Association of Cardiovascular Imaging recommendations (mean AT 73.3 ± 29 ms; mean DVI 0.5 ± 0.2). One patient had severe PVL and one presented with central regurgitation, both requiring re-intervention. The mortality rate was 5.1% ( n = 7); none of the cases was associated with valve insufficiency. Conclusions: The Dokimos prosthesis showed a satisfactory overall performance, presenting low gradients and DVIs as well as high EOAI. Further investigations are needed to analyse the cases of regurgitation and monitor long-term performance.


Subject(s)
Aortic Valve/surgery , Bioprosthesis , Heart Valve Diseases/surgery , Heart Valve Prosthesis Implantation/methods , Pericardium/surgery , Adult , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Echocardiography, Doppler , Female , Heart Valve Diseases/diagnosis , Humans , Male , Middle Aged , Prosthesis Design
19.
Sci Rep ; 6: 35725, 2016 10 19.
Article in English | MEDLINE | ID: mdl-27759115

ABSTRACT

Perioperative necessity of deep sedation is inevitably associated with diaphragmatic inactivation. This study investigated 1) the feasibility of a new phrenic nerve stimulation method allowing early diaphragmatic activation even in deep sedation and, 2) metabolic changes within the diaphragm during mechanical ventilation compared to artificial activity. 12 piglets were separated into 2 groups. One group was mechanically ventilated for 12 hrs (CMV) and in the second group both phrenic nerves were stimulated via pacer wires inserted near the phrenic nerves to mimic spontaneous breathing (STIM). Lactate, pyruvate and glucose levels were measured continuously using microdialysis. Oxygen delivery and blood gases were measured during both conditions. Diaphragmatic stimulation generated sufficient tidal volumes in all STIM animals. Diaphragm lactate release increased in CMV transiently whereas in STIM lactate dropped during this same time point (2.6 vs. 0.9 mmol L-1 after 5:20 hrs; p < 0.001). CMV increased diaphragmatic pyruvate (40 vs. 146 µmol L-1 after 5:20 hrs between CMV and STIM; p < 0.0001), but not the lactate/pyruvate ratio. Diaphragmatic stimulation via regular electrodes is feasible to generate sufficient ventilation, even in deep sedation. Mechanical ventilation alters the metabolic state of the diaphragm, which might be one pathophysiologic origin of ventilator-induced diaphragmatic dysfunction. Occurrence of hypoxia was unlikely.


Subject(s)
Diaphragm/metabolism , Pulmonary Ventilation , Respiration, Artificial , Animals , Glucose/analysis , Lactates/analysis , Phrenic Nerve , Pyruvates/analysis , Swine , Transcutaneous Electric Nerve Stimulation
20.
Tissue Eng Part C Methods ; 22(10): 974-981, 2016 10.
Article in English | MEDLINE | ID: mdl-27673356

ABSTRACT

Tissue-engineered heart valves are developed in bioreactors where biochemical and mechanical stimuli are provided for extracellular matrix formation. During this phase, the monitoring possibilities are limited by the need to maintain the sterility and integrity of the valve. Therefore, noninvasive and nondestructive techniques are required. As such, optical imaging is commonly used to verify valve's functionality in vitro. It provides important information (i.e., leaflet symmetry, geometric orifice area, and closing and opening times), which is, however, usually limited to a singular view along the central axis from the outflow side. In this study, we propose ultrasound as a monitoring method that, in contrast to established optical imaging, can assess the valve from different planes, scanning the whole three-dimensional geometry. We show the potential benefits associated with the application of ultrasound to bioreactors, in advancing heart valve tissue engineering from design to fabrication and in vitro maturation. Specifically, we demonstrate that additional information, otherwise unavailable, can be gained to evaluate the valve's functionality (e.g., coaptation length, and effective cusp height and shape). Furthermore, we show that Doppler techniques provide qualitative visualization and quantitative evaluation of the flow through the valve, in real time and throughout the whole in vitro fabrication phase.


Subject(s)
Heart Valves/diagnostic imaging , Heart Valves/physiology , Models, Cardiovascular , Tissue Engineering/methods , Ultrasonography/methods , Umbilical Veins/cytology , Cells, Cultured , Humans , In Vitro Techniques
SELECTION OF CITATIONS
SEARCH DETAIL
...