Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Front Immunol ; 9: 1448, 2018.
Article in English | MEDLINE | ID: mdl-29988573

ABSTRACT

Liver dysfunction (LD) and liver failure are associated with poor outcome in critically ill patients. In patients with severe sepsis or septic shock, LD occurred in nearly 19% of patients. An early diagnosis of LD at time of initial damage of the liver can lead to a better prognosis of these patients because an early start of therapy is possible. We performed a second prospective study with septic patients to test a new cell-based cytotoxicity device (biosensor) to evaluate clinical relevance for early diagnosis of LD and prognostic capacity. In the clinical study, 99 intensive care unit patients were included in two groups. From the patients of the septic group (n = 51, SG), and the control (non-septic) group [n = 49, control group (CG)] were drawn 20 ml blood at inclusion, after 3, and 7 days for testing with the biosensor. Patients' data were recorded for hospital survival, organ function, and demographic data, illness severity [acute physiology and chronic health evaluation (APACHE) II-, sepsis-related organ failure assessment (SOFA) scores], cytokines, circulating-free deoxyribonucleic acid/neutrophil-derived extracellular traps (cf-DNA/NETs), microbiological results, and pre-morbidity. For the developed cytotoxicity test, the human liver cell line HepG2/C3A was used. Patients' plasma was incubated in a microtiter plate assay with the test cells and after 6 days incubation the viability (trypan blue staining, XTT-test) and functionality (synthesis of albumin, cytochrome 1A2 activity) was analyzed. An impairment of viability and functionality of test cells was only seen in the SG compared with the CG. The plasma of non-survivors in the SG led to a more pronounced impairment of test cells than the plasma of survivors at inclusion. In addition, the levels of cf-DNA/NETs were significantly higher in the SG at inclusion, after 3, and after 7 days compared with the CG. The SG showed an in-hospital mortality of 24% and the values of bilirubin, APACHE II-, and SOFA scores were markedly higher at inclusion than in the CG. Hepatotoxicity of septic plasma was already detected with the liver cell-based biosensor at inclusion and also in the course of disease. The biosensor may be a tool for early diagnosis of LD in septic patients and may have prognostic relevance.

2.
Eur J Anaesthesiol ; 34(9): 623-627, 2017 09.
Article in English | MEDLINE | ID: mdl-28763317

ABSTRACT

BACKGROUND: The development of liver failure is a major problem in critically ill patients. The hepatotoxicity of many drugs, as one important reason for liver failure, is poorly screened for in human models. Rocuronium and succinylcholine are neuromuscular blocking agents used for tracheal intubation and for rapid-sequence induction. OBJECTIVE: We used an in-vitro test with a permanent cell line and compared rocuronium and succinylcholine for hepatotoxicity. DESIGN: In-vitro study. SETTING: A basic science laboratory, University Hospital Rostock, Germany. MATERIAL/(PATIENTS): The basic test compound is the permanent human liver cell line HepG2/C3A. In a standardised microtitre plate assay the toxicity of different concentrations of rocuronium, succinylcholine and plasma control was tested. INTERVENTIONS: After two incubation periods of 3 days, the viability of cells (XTT test, lactate dehydrogenase release and trypan blue staining), micro-albumin synthesis and the cytochrome 1A2 activity (metabolism of ethoxyresorufin) were measured. MAIN OUTCOME MEASURES: Differences between rocuronium and succinylcholine were assessed using the Kruskal-Wallis one-way test and two-tailed Mann-Whitney U test. RESULTS: Rocuronium, but not succinylcholine, led to a significant dose-dependent decrease of viability, albumin synthesis and cytochrome 1A2 activity of test cells. CONCLUSION: An in-vitro test with a cell line showed hepatotoxicity of rocuronium that was dose-dependent. Further studies are needed to investigate the underlying mechanisms of the effects of rocuronium on hepatic cellular integrity. TRIAL REGISTRATION: Not suitable.


Subject(s)
Liver/drug effects , Neuromuscular Depolarizing Agents/adverse effects , Neuromuscular Nondepolarizing Agents/adverse effects , Rocuronium/adverse effects , Succinylcholine/adverse effects , Dose-Response Relationship, Drug , Drug Evaluation, Preclinical , Hep G2 Cells , Humans , Liver/cytology , Neuromuscular Blockade/adverse effects , Neuromuscular Blockade/methods , Neuromuscular Depolarizing Agents/administration & dosage , Neuromuscular Nondepolarizing Agents/administration & dosage , Rocuronium/administration & dosage , Succinylcholine/administration & dosage
3.
Biomed Res Int ; 2016: 7056492, 2016.
Article in English | MEDLINE | ID: mdl-27433475

ABSTRACT

Purpose. Granulocyte transfusions have been used to treat immune cell dysfunction in sepsis. A granulocyte bioreactor for the extracorporeal treatment of sepsis was tested in a prospective clinical study focusing on the dosage of norepinephrine in patients and influence on dynamic and cell based liver tests during extracorporeal therapies. Methods and Patients. Ten patients with severe sepsis were treated twice within 72 h with the system containing granulocytes from healthy donors. Survival, physiologic parameters, extended hemodynamic measurement, and the indocyanine green plasma disappearance rate (PDR) were monitored. Plasma of patients before and after extracorporeal treatments were tested with a cell based biosensor for analysis of hepatotoxicity. Results. The observed mortality rate was 50% during stay in hospital. During the treatments, the norepinephrine-dosage could be significantly reduced while mean arterial pressure was stable. In the cell based analysis of hepatotoxicity, the viability and function of sensor-cells increased significantly during extracorporeal treatment in all patients and the PDR-values increased significantly between day 1 and day 7 only in survivors. Conclusion. The extracorporeal treatment with donor granulocytes showed promising effects on dosage of norepinephrine in patients, liver cell function, and viability in a cell based biosensor. Further studies with this approach are encouraged.


Subject(s)
Extracorporeal Circulation/methods , Liver, Artificial , Liver/pathology , Norepinephrine/therapeutic use , Sepsis/pathology , Sepsis/therapy , Adult , Aged , Aged, 80 and over , Biomarkers/metabolism , Cell Count , Cohort Studies , Cytochrome P-450 CYP1A2 , Cytokines/metabolism , Dose-Response Relationship, Drug , Hemodynamics , Hep G2 Cells , Humans , Inflammation/pathology , L-Lactate Dehydrogenase/metabolism , Liver Function Tests , Male , Middle Aged , Norepinephrine/administration & dosage , Survival Analysis , Treatment Outcome
4.
Inflamm Res ; 61(6): 609-16, 2012 Jun.
Article in English | MEDLINE | ID: mdl-22370970

ABSTRACT

OBJECTIVE AND DESIGN: The development of liver failure is a major problem in septic patients. In this prospective clinical experimental study the hepatotoxicity of plasma from septic and non-septic patients was tested. METHODS AND SUBJECTS: The basic test components consist of human liver cells (HepG2/C3A) used in a standardized microtiter plate assay. After incubation with patient's plasma viability of cells (XTT-test), the cytochrome 1A2 activity and synthesis of micro albumin were measured. Subjects (28) enrolled comprise the septic shock group (SSG, n=10), the non-septic group (NSG, n=5) and the healthy volunteers group (HVG, n=13). RESULTS: The 28-day mortality was 30% in the SSG. The APACHE II-, SOFA-, and SAPS-scores and the values of bilirubin and prothrombin time as INR were significantly higher in the SSG than in the NSG. The cytochrome 1A2 activity and the release of albumin were significantly reduced in HepG2/C3A cells incubated with plasma of the SSG (p<0.05). The cytochrome 1A2 activities were higher in survivors compared to non-survivors at the time point 0 and were increasing in survivors and decreasing in non-survivors within 54 h in the SSG. In the SSG there was a significant decrease in IL-10 and IL-8 between inclusion and 54 h. Values of IL-6, TNF alpha and IL-10 were significantly lower in the NSG compared with the values of the SSG at inclusion and after 54 h. CONCLUSION: The plasma of patients with septic shock impaired cellular functions of HepG2/C3A cells.


Subject(s)
Hepatocytes/metabolism , Liver Failure/metabolism , Sepsis/metabolism , Adult , Aged , Aged, 80 and over , Albumins/metabolism , Bilirubin/blood , Case-Control Studies , Cell Line, Tumor , Cytochrome P-450 CYP1A2/metabolism , Cytokines/blood , Female , Humans , Liver Failure/blood , Male , Middle Aged , Sepsis/blood
SELECTION OF CITATIONS
SEARCH DETAIL
...