1.
Am J Infect Control ; 48(9): 1013-1018, 2020 09.
Article in English | MEDLINE | ID: mdl-31928890

ABSTRACT

BACKGROUND: Needleless connectors (NCs) were introduced to reduce health care work needlestick injuries (NSIs). If not decontaminated prior to use, NCs can be a portal for patient blood stream infections. The optimal disinfectant, and its application duration, for NC decontamination has not been empirically established. METHODS: Factorial design randomized controlled trial comparing 70% isopropyl alcohol (IPA) and 2% chlorhexidine gluconate (CHG) in 70% IPA for 5, 10, or 15 seconds, in adult medical patients with peripheral intravenous catheters. RESULTS: At baseline, 153 of 300 NCs (51%) grew microorganisms commonly found on the skin. Decontamination was successful in 150/153 (98%). There was no significant difference in decontamination between 70% IPA or 2% CHG in 70% IPA (P = .62), or decontamination for 5, 10, or 15 seconds (P = .21). CONCLUSIONS: There was no difference in the effectiveness of 70% IPA and 2% CHG in 70% IPA for NC decontamination for peripheral intravenous catheters in the clinical environment. Successful decontamination was not different for applications of 5, 10, and 15 seconds; 15 seconds did not always remove all microorganisms. Factors such as cost, feasibility of compliance, and low risk of allergy support 5 seconds decontamination with 70% IPA as an acceptable approach.


Subject(s)
Catheters , Decontamination , Disinfectants , 2-Propanol , Adult , Chlorhexidine , Humans , Infection Control , Skin
2.
Am J Infect Control ; 45(8): 932-934, 2017 Aug 01.
Article in English | MEDLINE | ID: mdl-28330709

ABSTRACT

The aim of this study was to quantify culturable microorganisms on needleless connectors (NCs) attached to peripheral intravenous catheters in hospitalized adult medical patients. Half (50%) of 40 NCs were contaminated with microorganisms commonly found on the skin or mouth. Staphylococcus capitis and Staphylococcus epidermidis were most commonly isolated. Emergency department insertion and higher patient dependency were statistically associated with positive NC microorganism growth. These results reaffirm the need for NC decontamination prior to access.


Subject(s)
Equipment Contamination , Infusion Pumps/microbiology , Staphylococcus/isolation & purification , Adult , Catheters, Indwelling/adverse effects , Hospitals , Humans