Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
BMJ Open ; 14(5): e082243, 2024 May 08.
Article in English | MEDLINE | ID: mdl-38719293

ABSTRACT

INTRODUCTION: The femoral head contralateral to the collapsed femoral head requiring total hip arthroplasty (THA) often manifests in the precollapse stage of osteonecrosis of the femoral head (ONFH). It is not yet demonstrated how autologous concentrated bone marrow injection may prevent collapse of the femoral head concurrent with contralateral THA. The primary objective is to evaluate the efficacy of autologous concentrated bone marrow injection for the contralateral, non-collapsed, femoral head in patients with bilateral ONFH, with the ipsilateral collapsed femoral head undergoing THA. METHODS AND ANALYSIS: This is a multicentre, prospective, non-randomised, historical-data controlled study. We will recruit patients with ONFH who are scheduled for THA and possess a non-collapsed contralateral femoral head. Autologous bone marrow will be collected using a point-of-care device. After concentration, the bone marrow will be injected into the non-collapsed femoral head following the completion of THA in the contralateral hip. The primary outcome is the percentage of femoral head collapse evaluated by an independent data monitoring committee using plain X-rays in two directions 2 years after autologous concentrated bone marrow injection. Postinjection safety, adverse events, pain and hip function will also be assessed. The patients will be evaluated preoperatively, and at 6 months, 1 year and 2 years postoperatively. ETHICS AND DISSEMINATION: This protocol has been approved by the Certified Committee for Regenerative Medicine of Tokyo Medical and Dental University and Japan's Ministry of Healthy, Labour and Welfare and will be performed as a class III regenerative medicine protocol, in accordance with Japan's Act on the Safety of Regenerative Medicine. The results of this study will be submitted to a peer-review journal for publication. The results of this study are expected to provide evidence to support the inclusion of autologous concentrated bone marrow injections in the non-collapsed femoral head in Japan's national insurance coverage. TRIAL REGISTRATION NUMBER: jRCTc032200229.


Subject(s)
Arthroplasty, Replacement, Hip , Bone Marrow Transplantation , Femur Head Necrosis , Transplantation, Autologous , Humans , Femur Head Necrosis/surgery , Femur Head Necrosis/therapy , Arthroplasty, Replacement, Hip/methods , Prospective Studies , Bone Marrow Transplantation/methods , Adult , Multicenter Studies as Topic , Female , Male , Middle Aged , Non-Randomized Controlled Trials as Topic , Femur Head
2.
Int Orthop ; 48(4): 1089-1096, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38332113

ABSTRACT

PURPOSE: Although rare, non-metastatic proximal femoral fracture (PFF) can develop in patients with active cancer. However, little data are available regarding the risks and benefits of surgical treatment in such patients. The purpose of his study was to investigate the risks and benefits of surgical treatment of PFF in patients with and without cancer. METHODS: We retrospectively examined the medical records of all patients treated for PFF, excluding those with pathological fracture, at our hospital from July 2013 to December 2020. The patients were divided into two groups; The active cancer group and the standard group. We investigated in both groups about surgical and medical complications during the perioperative period, walking ability two weeks postoperatively, and one-year postoperative mortality rate. RESULT: After the inclusion and exclusion criteria, 39 patients in the active cancer group and 331 patients in the standard group were finally investigated. There were no statistically significant differences between the two groups. The complication rate did not appear statistical significance between two groups (16.7% in active cancer group vs 10.7% in standard group: p = 0.272). Walking ability was also similar in two groups. Mortality rate at one year was significantly higher in the active cancer group. (41.2% in active cancer group vs 6.0% in standard group: p < 0.05). CONCLUSION: Although the active cancer group had a higher mortality rate at one year, which was influenced by the prognosis of the cancer, the benefits of surgical intervention, such as regaining walking ability, were the same in patients with and without active cancer.


Subject(s)
Arthroplasty, Replacement, Hip , Fractures, Spontaneous , Hip Fractures , Neoplasms , Humans , Retrospective Studies , Fractures, Spontaneous/surgery , Neoplasms/surgery
3.
Bone Jt Open ; 5(3): 154-161, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38423101

ABSTRACT

Aims: It is important to analyze objectively the hammering sound in cup press-fit technique in total hip arthroplasty (THA) in order to better understand the change of the sound during impaction. We hypothesized that a specific characteristic would present in a hammering sound with successful fixation. We designed the study to quantitatively investigate the acoustic characteristics during cementless cup impaction in THA. Methods: In 52 THAs performed between November 2018 and April 2022, the acoustic parameters of the hammering sound of 224 impacts of successful press-fit fixation, and 55 impacts of unsuccessful press-fit fixation, were analyzed. The successful fixation was defined if the following two criteria were met: 1) intraoperatively, the stability of the cup was retained after manual application of the torque test; and 2) at one month postoperatively, the cup showed no translation on radiograph. Each hammering sound was converted to sound pressures in 24 frequency bands by fast Fourier transform analysis. Basic patient characteristics were assessed as potential contributors to the hammering sound. Results: The median sound pressure (SP) of successful fixation at 0.5 to 1.0 kHz was higher than that of unsuccessful fixation (0.0694 (interquartile range (IQR) 0.04721 to 0.09576) vs 0.05425 (IQR 0.03047 to 0.06803), p < 0.001). The median SP of successful fixation at 3.5 to 4.0 kHz and 4.0 to 4.5 kHz was lower than that of unsuccessful fixation (0.0812 (IQR 0.05631 to 0.01161) vs 0.1233 (IQR 0.0730 to 0.1449), p < 0.001; and 0.0891 (IQR 0.0526 to 0.0891) vs 0.0885 (IQR 0.0716 to 0.1048); p < 0.001, respectively). There was a statistically significant positive relationship between body weight and SP at 0.5 to 1.0 kHz (p < 0.001). Multivariate analyses indicated that the SP at 0.5 to 1.0 kHz and 3.5 to 4.0 kHz was independently associated with the successful fixation. Conclusion: The frequency bands of 0.5 to 1.0 and 3.5 to 4.0 kHz were the key to distinguish the sound characteristics between successful and unsuccessful press-fit cup fixation.

4.
Regen Ther ; 25: 61-67, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38077288

ABSTRACT

Introduction: Although numerous studies have reported outcomes with various conservative approaches for the iliopsoas impingement after total hip arthroplasty (THA), reports on the use of locoregional autologous platelet rich plasma (PRP) injections for the iliopsoas impingement after THA are lacking. This phase 1 study therefore aimed to investigate the safety and feasibility of locoregional PRP injection for iliopsoas impingement after THA. Materials and methods: Patients diagnosed with iliopsoas impingement after THA who met the criteria for participation (symptoms persisting for more than 3 months, aged 20 years or older, and unable to receive non-steroidal analgesic or anti-inflammatory drugs) were eligible to participate in this clinical study. The primary endpoint was observed adverse events including procedure-related pain, and the secondary endpoints included pain and functionality of the hip joint, that were assessed using the Western Ontario and McMaster Universities Arthritis Index, Japanese Hip Disease Evaluation Questionnaire, and Forgotten Joint Score-12. Results: Three patients were screened for eligibility, and 3 patients were finally included in this study. Two participants (patients 1 and 2; aged 66 and 65 years, respectively) were female. The third participant (patient 3; age 73 years) was male. All patients experienced adverse events; however, none were found to be serious. None of the patients experienced any infections, or intra- or post-operative symptoms of nerve damage, or subcutaneous haemorrhage owing to the administration of locoregional PRP. Although patient 2 showed almost complete resolution of the symptom, patient 1 and 3 demonstrated persistent groin pain after the injection. Conclusion: We demonstrated the results of preliminary phase 1 prospective observational clinical study that administration of locoregional PRP injections for iliopsoas impingement following THA is both, safe and feasible.

5.
Expert Rev Med Devices ; 20(12): 1079-1086, 2023.
Article in English | MEDLINE | ID: mdl-37942898

ABSTRACT

INTRODUCTION: The direct anterior approach (DAA) has its origins in the first and oldest approach for hip replacement in the literature, but at the same time it would not be fanciful to suggest its increasing popularity as the latest approach for hip replacement procedures, especially among younger surgeons. However, in a geographical context, the DAA is not considered the major approach in most countries. Moreover, the term DAA encompasses numerous variations in terms of technique. AREAS COVERED: In this narrative review, we describe our recent experience of advances in the DAA in terms of improved techniques and devices, along with some of its disadvantages. Also, we express our perspective on its future application. EXPERT OPINIONS: The DAA is established as one of exemplary approaches to THA. The use of fluoroscopy, the traction table, and appropriate soft tissue management has become essential in the DAA for a safe and trouble-free procedure with adequate patient comfort. With the combination of recent technologies such as robotics, three-dimensional preoperative planning, and artificial intelligence (AI)-based surgeon assist systems, we can look forward to the DAA being performed more efficiently in the future.


Subject(s)
Arthroplasty, Replacement, Hip , Surgeons , Humans , Artificial Intelligence , Traction , Retrospective Studies
6.
Int Orthop ; 47(1): 187-192, 2023 01.
Article in English | MEDLINE | ID: mdl-36416898

ABSTRACT

PURPOSE: Acoustic analysis has recently been applied to cementless total hip arthroplasty (THA). The aim of this study was to develop a machine learning algorithm to predict post-operative subsidence with high accuracy. METHODS: The acoustic parameters of the hammering sounds during a broaching procedure for 62 hips in 55 patients who underwent THAs with cementless taper-wedged stem were analysed. The patient's basic background such as age, sex, height, weight and body mass index, the femoral morphological parameters and the hammering sound characteristics of 24 features of normalised sound pressure (nSP) in 24 frequency ranges were applied to binary classification using a support vector machine using the following models with different features: model A, nSP only; model B, nSP + patients' basic background features; model C, nSP + patients' basic background features + femoral morphological parameters. RESULTS: In 62 hips with 310 hammering sounds, 12 hips (19.4%) showed ≥ 3 mm of post-operative subsidence; hence, 60 hammering sounds were set as positive examples and 250 hammering sounds were set as negative examples. The AUC was very high in all models. The accuracy (AUC/sensitivity/specificity/positive predictive value/negative predictive value/accuracy rate) of each model was as follows: model A, 0.963/0.656/0.996/0.980/0.925/0.934; model B, 0.9866/0.675/1.000/1.000/0.928/0.937 and model C, 0.998/0.750/1.000/1.000/0.950/0.957. CONCLUSION: In this study, we developed a high-accuracy machine learning algorithm for post-operative subsidence using acoustic parameters and additional pre-operative features. Our results represent a step toward the realisation of acoustic monitoring to avoid the complication in cementless THA.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Humans , Arthroplasty, Replacement, Hip/adverse effects , Arthroplasty, Replacement, Hip/methods , Hip Prosthesis/adverse effects , Support Vector Machine , Femur/surgery , Acoustics , Prosthesis Design , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...