Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Biomed Opt Express ; 15(6): 3962-3974, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38867767

ABSTRACT

Adjuvants are indispensable ingredients in vaccine formulations. Evaluating the in vivo transport processes of adjuvants, particularly for inhalation formulations, presents substantial challenges. In this study, a nanosized adjuvant aluminum hydroxide (AlOOH) was synthesized and labeled with indocyanine green (ICG) and bovine serum albumin (BSA) to achieve strong optical absorption ability and high biocompatibility. The adjuvant nanomaterials (BSA@ICG@AlOOH, BIA) were delivered as an aerosol into the airways of mice, its distribution was monitored using photoacoustic imaging (PAI) in vivo. PAI results illustrated the gradual cross-layer transmission process of BIA in the tracheal layer, traversing approximately 250 µm from the inner layer of the trachea to the outer layer. The results were consistent with pathology. While the intensity of the BIA reduced by approximately 46.8% throughout the transport process. The ability of PAI for quantitatively characterized the dynamic transport process of adjuvant within the tracheal layer may be widely used in new vaccine development.

2.
Heliyon ; 10(3): e25066, 2024 Feb 15.
Article in English | MEDLINE | ID: mdl-38314292

ABSTRACT

This study describes a method for real-time examination of the microvascular system based on the three-dimensional photoacoustic imaging system to prevent arterial complications, especially vascular embolism, during hyaluronic acid (HA) injections. Chicken embryos were used to simulate the superficial blood vessels of human skin, and then the target area was imaged by the photoacoustic imaging system for three-dimensional vascular imaging, and then the syringe and blood vessels were monitored, and the syringe angle and penetration depth were adjusted in time using an injection device to avoid puncturing the arterial vasculature and clogging the blood vessels. HA was then injected into smaller vessels on the dorsum of the tongue in mice and into thicker vessels on the dorsal portion of the tongue in rats to mimic embolization, and the post-operative recovery was reflected by the changes in the pixel dots of the extracted part of the blocked blood vessels, and it was observed that the blood flow in the area of the fine vessels was restored in about 3 days, whereas blood flow in the area of the large vessels was restored in only about 1 h. The method presented in this paper allows precise guidance of injectable filler HA, which has good application prospects in improving the safety of injection micro-plastic surgery and reducing the experience requirements for medical personnel.

3.
Int J Nanomedicine ; 18: 4043-4054, 2023.
Article in English | MEDLINE | ID: mdl-37520300

ABSTRACT

Background: Carotid artery thrombosis is the leading cause of stroke. Since there are no apparent symptoms in the early stages of carotid atherosclerosis onset, it causes a more significant clinical diagnosis. Photoacoustic (PA) imaging provides high contrast and good depth information, which has been used for the early detection and diagnosis of many diseases. Methods: We investigated thrombus formation by using 20% ferric chloride (FeCl3) in the carotid arteries of KM mice for the thrombosis model. The near-infrared selenium/polypyrrole (Se@PPy) nanomaterials are easy to synthesize and have excellent optical absorption in vivo, which can be used as PA contrast agents to obtain thrombosis information. Results: In vitro experiments showed that Se@PPy nanocomposites have fulfilling PA ability in the 700 nm to 900 nm wavelength range. In the carotid atherosclerosis model, maximum PA signal enhancement up to 3.44, 4.04, and 5.07 times was observed by injection of Se@PPy nanomaterials, which helped to diagnose the severity of carotid atherosclerosis. Conclusion: The superior PA signal of Se@PPy nanomaterials can identify the extent of atherosclerotic carotid lesions, demonstrating the feasibility of PA imaging technology in diagnosing carotid thrombosis lesion formation. This study demonstrates nanocomposites and PA techniques for imaging and diagnosing carotid thrombosis in vivo.


Subject(s)
Atherosclerosis , Carotid Artery Diseases , Carotid Artery Thrombosis , Nanospheres , Photoacoustic Techniques , Selenium , Thrombosis , Animals , Mice , Polymers , Carotid Artery Thrombosis/chemically induced , Carotid Artery Thrombosis/diagnostic imaging , Photoacoustic Techniques/methods , Pyrroles , Carotid Arteries/diagnostic imaging , Thrombosis/diagnostic imaging
4.
Photoacoustics ; 31: 100523, 2023 Jun.
Article in English | MEDLINE | ID: mdl-37362871

ABSTRACT

Delayed treatment of testicular torsion (TT) can lead to permanent loss of reproductive capacity. Photoacoustic imaging (PAI) and ultrasound imaging (USI) was tested for detecting TT at early stage in mice based on PAI-obtained oxygen saturation (sO2), and USI-collected color pixel density (CPD), peak systolic velocity (PSV) and resistance index (RI). For complete TT, both CPD (9.08 % ± 3.084 to almost zero) and sO2 data (70.09 % ± 1.656-59.84 % ± 1.427) showed an significant change 2 h post-torsion. For incomplete TT, sO2 data exhibited a strong time relationship (Mean values: 6 h, 64.83 % ± 1.898; 12 h, 60.67 % ± 3.555; 24 h, 57.85 % ± 3.575; P < 0.05). However, USI-collected CPD, PSV or IR data from the same TT models showed no significant difference. This study indicated that USI and PAI could identify complete TT. Meanwhile, PAI has shown great potential in the diagnosis of incomplete TT within 24 h based on time-related sO2 map.

SELECTION OF CITATIONS
SEARCH DETAIL
...