1.
Mol Aspects Med ; 96: 101256, 2024 04.
Article in English | MEDLINE | ID: mdl-38359699

ABSTRACT

Well-characterized reference materials support harmonization and accuracy when conducting nucleic acid-based tests (such as qPCR); digital PCR (dPCR) can measure the absolute concentration of a specific nucleic acid sequence in a background of non-target sequences, making it ideal for the characterization of nucleic acid-based reference materials. National Metrology Institutes are increasingly using dPCR to characterize and certify their reference materials, as it offers several advantages over indirect methods, such as UV-spectroscopy. While dPCR is gaining widespread adoption, it requires optimization and has certain limitations and considerations that users should be aware of when characterizing reference materials. This review highlights the technical considerations of dPCR, as well as its role when developing and characterizing nucleic acid-based reference materials.


Subject(s)
Nucleic Acids , Humans , Polymerase Chain Reaction/methods , Real-Time Polymerase Chain Reaction/methods
2.
Sci Rep ; 13(1): 14470, 2023 09 02.
Article in English | MEDLINE | ID: mdl-37660227

ABSTRACT

Lentiviral vectors (LV) have proven to be powerful tools for stable gene delivery in both dividing and non-dividing cells. Approval of these LVs for use in clinical applications has been achieved by improvements in LV design. Critically important characteristics concerning quality control are LV titer quantification and the detection of impurities. However, increasing evidence concerning high variability in titration assays indicates poor harmonization of the methods undertaken to date. In this study, we developed a direct reverse transcription droplet digital PCR (Direct RT-ddPCR) approach without RNA extraction and purification for estimation of LV titer and RNA genome integrity. The RNA genome integrity was assessed by RT-ddPCR assays targeted to four distant regions of the LV genome. Results of the analyses showed that direct RT-ddPCR without RNA extraction and purification performs similarly to RT-ddPCR on purified RNA from 3 different LV samples, in terms of robustness and assay variance. Interestingly, these RNA titer results were comparable to physical titers by p24 antigen ELISA (enzyme-linked immunosorbent assay). Moreover, we confirmed the partial degradation or the incomplete RNA genomes in the prepared 3 LV samples. These results may partially explain the discrepancy of the LV particle titers to functional titers. This work not only demonstrates the feasibility of direct RT-ddPCR in determining LV titers, but also provides a method that can be easily adapted for RNA integrity assessment.


Subject(s)
RNA , Reverse Transcription , Biological Assay , Enzyme-Linked Immunosorbent Assay , Polymerase Chain Reaction
3.
iScience ; 25(7): 104554, 2022 Jul 15.
Article in English | MEDLINE | ID: mdl-35800774

ABSTRACT

Plasma cell-free DNA is being widely explored as a biomarker for clinical screening. Currently, methods are optimized for the extraction and detection of double-stranded mononucleosomal cell-free DNA of ∼160bp in length. We introduce uscfDNA-seq, a single-stranded cell-free DNA next-generation sequencing pipeline, which bypasses previous limitations to reveal a population of ultrashort single-stranded cell-free DNA in human plasma. This species has a modal size of 50nt and is distinctly separate from mononucleosomal cell-free DNA. Treatment with single-stranded and double-stranded specific nucleases suggests that ultrashort cell-free DNA is primarily single-stranded. It is distributed evenly across chromosomes and has a similar distribution profile over functional elements as the genome, albeit with an enrichment over promoters, exons, and introns, which may be suggestive of a terminal state of genome degradation. The examination of this cfDNA species could reveal new features of cell death pathways or it can be used for cell-free DNA biomarker discovery.

4.
Article in English | MEDLINE | ID: mdl-34250423

ABSTRACT

We report the results from a Foundation for the National Institutes of Health Biomarkers Consortium project to address the absence of well-validated quality control materials (QCMs) for circulating tumor DNA (ctDNA) testing. This absence is considered a cause of variance and inconsistencies in translating ctDNA results into clinical actions. METHODS: In this phase I study, QCMs with 14 clinically relevant mutations representing single nucleotide variants, insertions or deletions (indels), translocations, and copy number variants were sourced from three commercial manufacturers with variant allele frequencies (VAFs) of 5%, 2.5%, 1%, 0.1%, and 0%. Four laboratories tested samples in quadruplicate using two allele-specific droplet digital polymerase chain reaction and three (amplicon and hybrid capture) next-generation sequencing (NGS) panels. RESULTS: The two droplet digital polymerase chain reaction assays reported VAF values very close to the manufacturers' claimed concentrations for all QCMs. NGS assays reported most single nucleotide variants and indels, but not translocations, close to the expected VAF values. Notably, two NGS assays reported lower VAF than expected for all translocations in all QCM mixtures, possibly related to technical challenges detecting these variants. The ability to call ERBB2 copy number amplifications varied across assays. All three QCMs provided valuable insight into assay precision. Each assay across all variant types demonstrated dropouts at 0.1%, suggesting that the QCM can serve for testing of an assay's limit of detection with confidence claims for specific variants. CONCLUSION: These results support the utility of the QCM in testing ctDNA assay analytical performance. However, unique designs and manufacturing methods for the QCM, and variations in a laboratory's testing configuration, may require testing of multiple QCMs to find the best reagents for accurate result interpretation.


Subject(s)
Circulating Tumor DNA/genetics , High-Throughput Nucleotide Sequencing , Neoplasms/genetics , Polymerase Chain Reaction , Quality Control , Biomarkers, Tumor/genetics , Circulating Tumor DNA/blood , DNA Copy Number Variations , Gene Frequency , Humans , Mutation/genetics , National Institutes of Health (U.S.) , Neoplasms/blood , United States
5.
Sci Rep ; 11(1): 389, 2021 01 11.
Article in English | MEDLINE | ID: mdl-33431989

ABSTRACT

Lentiviral vectors (LV) have emerged as a robust technology for therapeutic gene delivery into human cells as advanced medicinal products. As these products are increasingly commercialized, there are concomitant demands for their characterization to ensure safety, efficacy and consistency. Standards are essential for accurately measuring parameters for such product characterization. A critical parameter is the vector copy number (VCN) which measures the genetic dose of a transgene present in gene-modified cells. Here we describe a set of clonal Jurkat cell lines with defined copy numbers of a reference lentiviral vector integrated into their genomes. Genomic DNA was characterized for copy number, genomic integrity and integration coordinates and showed uniform performance across independent quantitative PCR assays. Stability studies during continuous long-term culture demonstrated sustained renewability of the reference standard source material. DNA from the Jurkat VCN standards would be useful for control of quantitative PCR assays for VCN determination in LV gene-modified cellular products and clinical samples.


Subject(s)
Gene Dosage , Lentivirus/genetics , Transduction, Genetic , Calibration/standards , Gene Transfer Techniques/standards , Genetic Vectors/genetics , Humans , Jurkat Cells , Mutagenesis, Insertional/genetics , Reference Standards , Reproducibility of Results , Transduction, Genetic/methods , Transduction, Genetic/standards , Transfection/methods , Transfection/standards , Validation Studies as Topic , Virus Integration/genetics
6.
J Mol Diagn ; 21(4): 658-676, 2019 07.
Article in English | MEDLINE | ID: mdl-31055023

ABSTRACT

We conducted a multilaboratory assessment to determine the suitability of a new commercially available reference material with 40 cancer variants in a background of wild-type DNA at four different variant allele frequencies (VAFs): 2%, 0.50%, 0.125%, and 0%. The variants include single nucleotides, insertions, deletions, and two structural variations selected for their clinical importance and to challenge the performance of next-generation sequencing (NGS) methods. Fragmented DNA was formulated to simulate the size distribution of circulating wild-type and tumor DNA in a synthetic plasma matrix. DNA was extracted from these samples and characterized with different methods and multiple laboratories. The various extraction methods had differences in yield, perhaps because of differences in chemistry. Digital PCR assays were used to measure VAFs to compare results from different NGS methods. Comparable VAFs were observed across the different NGS methods. This multilaboratory assessment demonstrates that the new reference material is an appropriate tool to determine the analytical parameters of different measurement methods and to ensure their quality assurance.


Subject(s)
Biomarkers, Tumor , Circulating Tumor DNA , DNA, Neoplasm , Liquid Biopsy , Neoplasms/diagnosis , Neoplasms/genetics , Alleles , High-Throughput Nucleotide Sequencing/methods , High-Throughput Nucleotide Sequencing/standards , Humans , Liquid Biopsy/methods , Liquid Biopsy/standards , Polymerase Chain Reaction/methods , Polymerase Chain Reaction/standards , Quality Assurance, Health Care , Reference Standards
7.
Clin Chem Lab Med ; 57(8): 1142-1152, 2019 07 26.
Article in English | MEDLINE | ID: mdl-31112502

ABSTRACT

Background The National Institute of Standards and Technology (NIST) Reference Material RM 8366 was developed to improve the quality of gene copy measurements of EGFR (epidermal growth factor receptor) and MET (proto-oncogene, receptor tyrosine kinase), important targets for cancer diagnostics and treatment. The reference material is composed of genomic DNA prepared from six human cancer cell lines with different levels of amplification of the target genes. Methods The reference values for the ratios of the EGFR and MET gene copy numbers to the copy numbers of reference genes were measured using digital PCR. The digital PCR measurements were confirmed by two additional laboratories. The samples were also characterized using Next Generation Sequencing (NGS) methods including whole genome sequencing (WGS) at three levels of coverage (approximately 1 ×, 5 × and greater than 30 ×), whole exome sequencing (WES), and two different pan-cancer gene panels. The WES data were analyzed using three different bioinformatic algorithms. Results The certified values (digital PCR) for EGFR and MET were in good agreement (within 20%) with the values obtained from the different NGS methods and algorithms for five of the six components; one component had lower NGS values. Conclusions This study shows that NIST RM 8366 is a valuable reference material to evaluate the performance of assays that assess EGFR and MET gene copy number measurements.


Subject(s)
High-Throughput Nucleotide Sequencing/standards , Proto-Oncogene Proteins c-met/genetics , DNA, Neoplasm/genetics , ErbB Receptors/genetics , ErbB Receptors/standards , Gene Dosage , Humans , Polymerase Chain Reaction , Proto-Oncogene Mas , Proto-Oncogene Proteins c-met/standards , Reference Standards , Tumor Cells, Cultured
8.
Clin Chem ; 64(9): 1296-1307, 2018 09.
Article in English | MEDLINE | ID: mdl-29903874

ABSTRACT

BACKGROUND: Genetic testing of tumor tissue and circulating cell-free DNA for somatic variants guides patient treatment of many cancers. Such measurements will be fundamental in the future support of precision medicine. However, there are currently no primary reference measurement procedures available for nucleic acid quantification that would support translation of tests for circulating tumor DNA into routine use. METHODS: We assessed the accuracy of digital PCR (dPCR) for copy number quantification of a frequently occurring single-nucleotide variant in colorectal cancer (KRAS c.35G>A, p.Gly12Asp, from hereon termed G12D) by evaluating potential sources of uncertainty that influence dPCR measurement. RESULTS: Concentration values for samples of KRAS G12D and wild-type plasmid templates varied by <1.2-fold when measured using 5 different assays with varying detection chemistry (hydrolysis, scorpion probes, and intercalating dyes) and <1.3-fold with 4 commercial dPCR platforms. Measurement trueness of a selected dPCR assay and platform was validated by comparison with an orthogonal method (inductively coupled plasma mass spectrometry). The candidate dPCR reference measurement procedure showed linear quantification over a wide range of copies per reaction and high repeatability and interlaboratory reproducibility (CV, 2%-8% and 5%-10%, respectively). CONCLUSIONS: This work validates dPCR as an SI-traceable reference measurement procedure based on enumeration and demonstrates how it can be applied for assignment of copy number concentration and fractional abundance values to DNA reference materials in an aqueous solution. High-accuracy measurements using dPCR will support the implementation and traceable standardization of molecular diagnostic procedures needed for advancements in precision medicine.


Subject(s)
Polymerase Chain Reaction/methods , Precision Medicine , DNA Copy Number Variations , Humans , Mass Spectrometry , Reproducibility of Results
9.
Biotechniques ; 64(2): 59-68, 2018 02 01.
Article in English | MEDLINE | ID: mdl-29571283

ABSTRACT

We compared different methods (absorbance, fluorescent dye-binding, and digital PCR) for measuring the concentrations of human genomic DNA from cultured cells and absorbance measurements of a synthetic DNA oligonucleotide. NIST Standard Reference Material (SRM) 2082, a pathlength absorbance standard, was used to benchmark the absorbance measurements done with microvolume spectrophotometers and a microvolume plate reader. Control absorbance values were measured on a high accuracy spectrophotometer and a NIST calibrated pathlength cuvette. Measurements of the human genomic DNA sample were done with several types of fluorescent dye binding assays using different DNA calibrators. The fluorescent dye binding methods gave different results for genomic DNA depending upon the type of DNA calibrator and the fluorescent dye that was used. The human genomic DNA sample was also characterized by using six different droplet digital PCR assays (amplicons located on different chromosomes) to measure the average copy number. Conversion of the digital PCR data to copy numbers was sensitive to the droplet size used for calculations and conversion to mass concentration was dependent upon the molecular weight of the human genome used for the calculations. The results from the different methods were compared and the caveats for each measurement method were discussed.


Subject(s)
DNA/analysis , Oligonucleotides/analysis , Fluorometry , Humans , Polymerase Chain Reaction , Spectrophotometry
10.
Biopharm Int ; 31(4): 22-34, 2018.
Article in English | MEDLINE | ID: mdl-30996711

ABSTRACT

Ultraviolet (UV) absorbance measurements provide a rapid and reliable method to determine protein concentrations. the National Institute of standards and technology (NIST) has developed Standard Reference Material (SRM) 2082 as a pathlength standard for UV absorbance measurements for use with the new generation of microvolume spectrophotometers and short-pathlength cuvettes. short pathlengths are used with high-concentration targets to ensure that absorbance values are within the optimal range. the short-pathlength instruments and cuvettes also reduce the required volumes to conserve valuable samples. the authors compared the results obtained with high-quality dual-beam spectrophotometers and short-pathlength cuvettes to the results obtained from a microvolume spectrophotometer and a microvolume plate reader. SRM 2082 can be used to accurately calculate pathlength values, thereby increasing the accuracy in subsequent measurements using the short-pathlength cuvettes and microvolume absorbance instruments. RM 8671 (reference material, the NISTmAb) can then be used to ensure the accuracy and reproducibility of protein concentration measurements by providing an industrially relevant reference material, a well-characterized monoclonal antibody.

11.
J Mol Diagn ; 18(5): 753-761, 2016 09.
Article in English | MEDLINE | ID: mdl-27455875

ABSTRACT

The National Institute of Standards and Technology (NIST) Standard Reference Materials 2373 is a set of genomic DNA samples prepared from five breast cancer cell lines with certified values for the ratio of the HER2 gene copy number to the copy numbers of reference genes determined by real-time quantitative PCR and digital PCR. Targeted-amplicon, whole-exome, and whole-genome sequencing measurements were used with the reference material to compare the performance of both the laboratory steps and the bioinformatic approaches of the different methods using a range of amplification ratios. Although good reproducibility was observed in each next-generation sequencing method, slightly different HER2 copy numbers associated with platform-specific biases were obtained. This study clearly demonstrates the value of Standard Reference Materials 2373 as reference material and as a calibrator for evaluating assay performance as well as for increasing confidence in reporting HER2 amplification for clinical applications.


Subject(s)
Gene Amplification , High-Throughput Nucleotide Sequencing , Receptor, ErbB-2/genetics , Reference Standards , Cell Line, Tumor , Exome , Female , Gene Dosage , Genome, Human , High-Throughput Nucleotide Sequencing/methods , High-Throughput Nucleotide Sequencing/standards , Humans , Male , Neoplasms/diagnosis , Neoplasms/genetics , Real-Time Polymerase Chain Reaction
12.
Biomol Detect Quantif ; 8: 1-8, 2016 Jun.
Article in English | MEDLINE | ID: mdl-27335805

ABSTRACT

NIST standard reference material (SRM) 2373 was developed to improve the measurements of the HER2 gene amplification in DNA samples. SRM 2373 consists of genomic DNA extracted from five breast cancer cell lines with different amounts of amplification of the HER2 gene. The five components are derived from the human cell lines SK-BR-3, MDA-MB-231, MDA-MB-361, MDA-MB-453, and BT-474. The certified values are the ratios of the HER2 gene copy numbers to the copy numbers of selected reference genes DCK, EIF5B, RPS27A, and PMM1. The ratios were measured using quantitative polymerase chain reaction and digital PCR, methods that gave similar ratios. The five components of SRM 2373 have certified HER2 amplification ratios that range from 1.3 to 17.7. The stability and homogeneity of the reference materials were shown by repeated measurements over a period of several years. SRM 2373 is a well characterized genomic DNA reference material that can be used to improve the confidence of the measurements of HER2 gene copy number.

13.
Clin Proteomics ; 11(1): 43, 2014.
Article in English | MEDLINE | ID: mdl-25593565

ABSTRACT

BACKGROUND: In our previous study that characterized different human CD4+ lymphocyte preparations, it was found that both commercially available cryopreserved peripheral blood mononuclear cells (PBMC) and a commercially available lyophilized PBMC (Cyto-Trol™) preparation fulfilled a set of criteria for serving as biological calibrators for quantitative flow cytometry. However, the biomarker CD4 protein expression level measured for T helper cells from Cyto-Trol was about 16% lower than those for cryopreserved PBMC and fresh whole blood using flow cytometry and mass cytometry. A primary reason was hypothesized to be due to steric interference in anti- CD4 antibody binding to the smaller sized lyophilized control cells. METHOD: Targeted multiple reaction monitoring (MRM) mass spectrometry (MS) is used to quantify the copy number of CD4 receptor protein per CD4+ lymphocyte. Scanning electron microscopy (SEM) is utilized to assist searching the underlying reasons for the observed difference in CD4 receptor copy number per cell determined by MRM MS and CD4 expression measured previously by flow cytometry. RESULTS: The copy number of CD4 receptor proteins on the surface of the CD4+ lymphocyte in cryopreserved PBMCs and in lyophilized control cells is determined to be (1.45 ± 0.09) × 10(5) and (0.85 ± 0.11) × 10(5), respectively, averaged over four signature peptides using MRM MS. In comparison with cryopreserved PBMCs, there are more variations in the CD4 copy number in lyophilized control cells determined based on each signature peptide. SEM images of CD4+ lymphocytes from lyophilized control cells are very different when compared to the CD4+ T cells from whole blood and cryopreserved PBMC. CONCLUSION: Because of the lyophilization process applied to Cyto-Trol control cells, a lower CD4 density value, defined as the copy number of CD4 receptors per CD4+ lymphocyte, averaged over three different production lots is most likely explained by the loss of the CD4 receptors on damaged and/or broken microvilli where CD4 receptors reside. Steric hindrance of antibody binding and the association of CD4 receptors with other biomolecules likely contribute significantly to the nearly 50% lower CD4 receptor density value for cryopreserved PBMC determined from flow cytometry compared to the value obtained from MRM MS.

14.
Proteomics Clin Appl ; 7(1-2): 17-29, 2013 Jan.
Article in English | MEDLINE | ID: mdl-23341234

ABSTRACT

Cancer is a heterogeneous disease characterized by changes in the levels and activities of important cellular proteins, including oncogenes and tumor suppressors. Genetic mutations cause changes in protein activity and protein expression levels that result in the altered metabolism, proliferation, and metastasis seen in cancer cells. The identification of the critical biochemical changes in cancer has led to advances in its detection and treatment. An important example of this is the measurement of human epidermal growth factor receptor 2 (HER2), where increased expression occurs in approximately 20-30% of breast cancer tumors. HER2 is a member of the epidermal growth factor receptor family and is an important biomarker expressed on the cell surface. Measurement of the HER2 levels in tumor cells provides diagnostic, prognostic, and treatment information, because a targeted therapeutic is available. The most common methods to measure HER2 levels are immunohistochemistry and in situ hybridization assays. The accurate and reliable measurements of the specific changes in protein biomarkers for detection and treatment of cancer are important challenges. This review is focused on efforts to improve the quantitation and reliability of cancer biomarkers by using standards and reference materials.


Subject(s)
Biomarkers, Tumor/analysis , Biomarkers, Tumor/standards , Breast Neoplasms/diagnosis , Receptor, ErbB-2/analysis , Breast Neoplasms/therapy , Humans , Immunohistochemistry , In Situ Hybridization
15.
Anal Chem ; 85(3): 1773-7, 2013 Feb 05.
Article in English | MEDLINE | ID: mdl-23286534

ABSTRACT

Cluster of differentiation 4 (CD4) is an important glycoprotein containing four extracellular domains, a transmembrane portion and a short intracellular tail. It locates on the surface of various types of immune cells and performs a critical role in multiple cellular functions such as signal amplification and activation of T cells. It is well-known as a clinical cell surface protein marker for study of HIV progression and for defining the T helper cell population in immunological applications. Moreover, CD4 protein has been used as a biological calibrator for quantification of other surface and intracellular proteins. However, flow cytometry, the conventional method of quantification of the CD4 density on the T cell surface depends on antibodies and has suffered from variables such as antibody clones, the fluorophore and conjugation chemistries, the fixation conditions, and the flow cytometric quantification methods used. In this study, we report the development of a highly reproducible nano liquid chromatography-multiple reaction monitoring mass spectrometry-based quantitative method to quantify the CD4 receptor density in units of copy number per cell on human CD4+ T cells. The method utilizes stable isotope-labeled full-length standard CD4 as an internal standard to measure endogenous CD4 directly, without the use of antibodies. The development of the mass spectrometry-based approach of CD4 protein quantification is important as a complementary strategy to validate the analysis from the cytometry-based conventional method. It also provides new support for quantitative understanding and advanced characterization of CD4 on CD4+ T cells.


Subject(s)
CD4 Antigens/analysis , CD4-Positive T-Lymphocytes/chemistry , Flow Cytometry/methods , Mass Spectrometry/methods , Chromatography, Liquid/methods , Humans
16.
Cytometry A ; 81(7): 567-75, 2012 Jul.
Article in English | MEDLINE | ID: mdl-22539147

ABSTRACT

To transform the linear fluorescence intensity scale obtained with fluorescent microspheres to an antibody bound per cell (ABC) scale, a biological cell reference material is needed. Optimally, this material should have a reproducible and tight ABC value for the expression of a known clinical reference biomarker. In this study, we characterized commercially available cryopreserved peripheral blood mononuclear cells (PBMCs) and two lyophilized PBMC preparations, Cyto-Trol and PBMC-National Institute for Biological Standard and Control (NIBSC) relative to freshly prepared PBMC and whole blood samples. It was found that the ABC values for CD4 expression on cryopreserved PBMC were consistent with those of freshly obtained PBMC and whole blood samples. By comparison, the ABC value for CD4 expression on Cyto-Trol is lower and the value on PBMC-NIBSC is much lower than those of freshly prepared cell samples using both conventional flow cytometry and CyTOF™ mass cytometry. By performing simultaneous surface and intracellular staining measurements on these two cell samples, we found that both cell membranes are mostly intact. Moreover, CD4(+) cell diameters from both lyophilized cell preparations are smaller than those of PBMC and whole blood. This could result in steric interference in antibody binding to the lyophilized cells. Further investigation of the fixation effect on the detected CD4 expression suggests that the very low ABC value obtained for CD4(+) cells from lyophilized PBMC-NIBSC is largely due to paraformaldehyde fixation; this significantly decreases available antibody binding sites. This study provides confirmation that the results obtained from the newly developed mass cytometry are directly comparable to the results from conventional flow cytometry when both methods are standardized using the same ABC approach.


Subject(s)
Antigens/metabolism , CD4-Positive T-Lymphocytes/metabolism , Flow Cytometry , Calibration , Cell Membrane/metabolism , Cell Separation , Fixatives/chemistry , Formaldehyde/chemistry , Humans , Permeability , Polymers/chemistry , Staining and Labeling , Tissue Fixation
17.
Anal Bioanal Chem ; 403(8): 2279-89, 2012 Jun.
Article in English | MEDLINE | ID: mdl-22354569

ABSTRACT

Glycosylation, the enzymatic addition of carbohydrates to a protein, is one of the most abundant post-translational modifications found in nature. There is variability in the number, location, and identity of glycans attached. As a result, a glycoprotein consists of a number of glycoforms with different combinations of glycans, potentially resulting in different stability, toxicity, and activity. This is especially important in the biopharmaceutical industry where product consistency and safety are vital. Glycoprotein analysis involves numerous mass spectrometry based techniques, each of which provides various aspects of characterization. The current paper describes two commonly used analytical techniques for glycoprotein characterization. In one experiment, nonspecific proteolysis is combined with a two-tiered mass spectrometry approach (MALDI-TOF and LC-MS/MS) to gain glycosylation site and glycan identity. In a second approach, glycans were enzymatically released, labeled with a fluorescent dye, and analyzed using LC-Fluorescence-MS/MS to give glycan identification and relative quantification. The type and degree of information yielded by each method is assessed in an effort to identify desired reference material characteristics for improving biopharmaceutical glycoanalysis.


Subject(s)
Glycoproteins/chemistry , Polysaccharides/analysis , Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization/methods , Tandem Mass Spectrometry/methods , Antibodies, Monoclonal, Murine-Derived/chemistry , Antibodies, Monoclonal, Murine-Derived/metabolism , Chromatography, Liquid/methods , Fluorescent Dyes/analysis , Glycoproteins/metabolism , Glycosylation , Humans , Polysaccharides/metabolism , Pronase/metabolism , Proteolysis , Rituximab , Streptomyces/enzymology
18.
J Biol Chem ; 286(22): 19270-9, 2011 Jun 03.
Article in English | MEDLINE | ID: mdl-21467030

ABSTRACT

In mammals, the transcriptional activity of signal transducer and activator of transcription 3 (STAT3) is regulated by the deacetylase SIRT1. However, whether the newly described nongenomic actions of STAT3 toward mitochondrial oxidative phosphorylation are dependent on SIRT1 is unclear. In this study, Sirt1 gene knock-out murine embryonic fibroblast (MEF) cells were used to delineate the role of SIRT1 in the regulation of STAT3 mitochondrial function. Here, we show that STAT3 mRNA and protein levels and the accumulation of serine-phosphorylated STAT3 in mitochondria were increased significantly in Sirt1-KO cells as compared with wild-type MEFs. Various mitochondrial bioenergetic parameters, such as the oxygen consumption rate in cell cultures, enzyme activities of the electron transport chain complexes in isolated mitochondria, and production of ATP and lactate, indicated that Sirt1-KO cells exhibited higher mitochondrial respiration as compared with wild-type MEFs. Two independent approaches, including ectopic expression of SIRT1 and siRNA-mediated knockdown of STAT3, led to reduction in intracellular ATP levels and increased lactate production in Sirt1-KO cells that were approaching those of wild-type controls. Comparison of profiles of phospho-antibody array data indicated that the deletion of SirT1 was accompanied by constitutive activation of the pro-inflammatory NF-κB pathway, which is key for STAT3 induction and increased cellular respiration in Sirt1-KO cells. Thus, SIRT1 appears to be a functional regulator of NF-κB-dependent STAT3 expression that induces mitochondrial biogenesis. These results have implications for understanding the interplay between STAT3 and SIRT1 in pro-inflammatory conditions.


Subject(s)
Embryo, Mammalian/metabolism , Fibroblasts/metabolism , Mitochondria/metabolism , Oxygen Consumption/physiology , STAT3 Transcription Factor/biosynthesis , Sirtuin 1/metabolism , Adenosine Triphosphate/biosynthesis , Adenosine Triphosphate/genetics , Animals , Embryo, Mammalian/cytology , Fibroblasts/cytology , Gene Expression Regulation/physiology , Gene Knockdown Techniques , Lactic Acid/metabolism , Mice , Mitochondria/genetics , NF-kappa B/genetics , NF-kappa B/metabolism , Oxidative Phosphorylation , Phosphorylation , STAT3 Transcription Factor/genetics , Sirtuin 1/genetics
19.
Clin Chim Acta ; 412(1-2): 107-11, 2011 Jan 14.
Article in English | MEDLINE | ID: mdl-20869361

ABSTRACT

BACKGROUND: Cardiac troponin I (cTnI) is considered the 'gold standard' cardiac biomarker. However, the result comparability of commercial cTnI immunoassays is still lacking despite the availability of NIST Standard Reference Material, SRM 2921 (human cardiac troponin). To facilitate the standardization of the cTnI immunoassays, a secondary reference material consisting of a panel of three cTnI-positive human serum pools is proposed by the IFCC Working Group on Standardization of Troponin I. The objective of this study is to develop measurement procedures for the characterization of the future secondary reference material using a pooled cTnI-positive serum sample as a development model. METHODS: We used magnetic beads coupled with 6 different anti-cTnI monoclonal antibodies that bind specifically to different amino acid sequence regions of the cTnI molecule to immunoprecipitate cTnI proteins from the pooled cTnI-positive serum sample followed by sensitive detection using a fluorescent Western blot. RESULTS: The degradation of cTnI in the pooled sample was detected and the concentration of cTnI was determined. CONCLUSION: We demonstrated the utility of this measurement procedure in support of the development of the proposed secondary cTnI-positive, serum-based reference material.


Subject(s)
Blood Chemical Analysis/standards , Blotting, Western/methods , Immunoassay/standards , Immunoprecipitation/methods , Myocardium/metabolism , Spectrometry, Fluorescence/methods , Troponin I/blood , Animals , Antibodies, Monoclonal/immunology , Blood Chemical Analysis/methods , Cattle , Humans , Immunoassay/methods , Luminescent Measurements , Peptide Fragments/immunology , Peptide Fragments/metabolism , Reference Standards , Troponin I/immunology , Troponin I/metabolism
20.
Clin Chem Lab Med ; 48(11): 1603-10, 2010 Nov.
Article in English | MEDLINE | ID: mdl-21062228

ABSTRACT

In this study, the first steps in the development of a secondary reference measurement procedure (RMP) 'higher metrological order measurement procedure' to support the cardiac troponin I (cTnI) standardization initiative is described. The RMP should be used to assign values to serum-based secondary reference materials (RMs) without analytical artifacts causing bias. A multiplexed bead-based assay and sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE) were used to identify the optimum monoclonal antibody pair (clones 560 and 19C7) for the RMP. Using these antibodies, an ELISA-based procedure was developed to accurately measure the main cTnI forms present in blood. The proposed RMP appears to show no bias when tested on samples containing various troponin complexes, phosphorylated and dephosphorylated forms, and heparin. The candidate assay displayed suitable linearity and sensitivity (limit of detection, 0.052 µg/L) for the measurement of the proposed cTnI secondary RMs. Preliminary comparison data on patient samples with a commercial cTnI assay are also provided to support the suitability of RMP for value assignment to RMs. Full validation and final assessment of the RMP will be performed through transferability and inter-comparison studies.


Subject(s)
Antibodies, Monoclonal/immunology , Blood Chemical Analysis/standards , Enzyme-Linked Immunosorbent Assay/standards , Myocardium , Troponin I/blood , Antibody Specificity , Electrophoresis, Polyacrylamide Gel , Humans , Immunoprecipitation , International Agencies , Male , Reference Standards , Spectrometry, Fluorescence , Troponin I/immunology
SELECTION OF CITATIONS