Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Opt Express ; 30(13): 22353-22363, 2022 Jun 20.
Article in English | MEDLINE | ID: mdl-36224934

ABSTRACT

Metamaterial with hyperbolic dispersion properties can effectively manipulate plasmonic resonances. Here, we designed a hyperbolic metamaterial (HMM) substrate with a near-zero dielectric constant in the near-infrared region to manipulate the plasmon resonance of the nano-antenna (NA). For NA arrays, tuning the equivalent permittivity of HMM substrate by modifying the thickness of Au/diamond, the wavelength range of plasmon resonance can be manipulated. When the size of the NA changes within a certain range, the spectral position of the plasmon resonance will be fixed in a narrow band close to the epsilon-near-zero (ENZ) wavelength and produce a phenomenon similar to "pinning effect." In addition, since the volume plasmon polaritons (VPP) mode is excited, it will couple with the localized surface plasmon (LSP) mode to generate a spectrum splitting. Therefore, the plasmon resonance is significantly affected and can be precisely controlled by designing the HMM substrate.

2.
Phys Med Biol ; 58(16): 5735-51, 2013 Aug 21.
Article in English | MEDLINE | ID: mdl-23902944

ABSTRACT

Proton resonance frequency shift-based MR thermometry is a promising temperature monitoring approach for thermotherapy but its accuracy is vulnerable to inter-scan motion. Model-based referenceless thermometry has been proposed to address this problem but phase unwrapping is usually needed before the model fitting process. In this paper, a referenceless MR thermometry method using phase finite difference that avoids the time consuming phase unwrapping procedure is proposed. Unlike the previously proposed phase gradient technique, the use of finite difference in the new method reduces the fitting error resulting from the ringing artifacts associated with phase discontinuity in the calculation of the phase gradient image. The new method takes into account the values at the perimeter of the region of interest because of their direct relevance to the extrapolated baseline phase of the region of interest (where temperature increase takes place). In simulation study, in vivo and ex vivo experiments, the new method has a root-mean-square temperature error of 0.35 °C, 1.02 °C and 1.73 °C compared to 0.83 °C, 2.81 °C, and 3.76 °C from the phase gradient method, respectively. The method also demonstrated a slightly higher, albeit small, temperature accuracy than the original referenceless MR thermometry method. The proposed method is computationally efficient (~0.1 s per image), making it very suitable for the real time temperature monitoring.


Subject(s)
Magnetic Resonance Imaging/methods , Protons , Thermometry/methods , Humans , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...