Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 17 de 17
Filter
1.
Clin Physiol Funct Imaging ; 44(2): 154-163, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37881129

ABSTRACT

BACKGROUND: The aim was to investigate to what extent the quantification of myocardial blood flow (MBF) from dynamic 13 N-NH3 positron emission tomography (PET) images is affected by time frame schemes, time-of-flight (ToF), reconstruction algorithms, blood pool volume of interest (VOI) locations and compartment models in patients with suspected chronic coronary syndrome. METHODS: A standard MBF value was determined from 25 patients' rest/stress 13 N-NH3 PET/CT images reconstructed with ordered subset expectation maximization (OSEM), 5 s time frame for the first frames without ToF, subsequently analyzed using a basal VOI and the deGrado compartment model. MBFs calculated using 2 or 10 s for the first frames, ToF, block-sequential regularized expectation maximization (BSREM), apical or large VOI, Hutchins or Krivokapich compartment models were compared to MBFstandard in Bland-Altman plots (bias ± SD). RESULTS: Good agreement in global rest/stress MBF (mL/min/g) was found when changing the time frame scheme or reconstruction algorithm (MBFstandard vs. MBF2s : -0.02 ± 0.06; MBF10s : 0.01 ± 0.07; MBFBSREM : 0.01 ± 0.07), while a lower level of agreement was found when altering the other factors (MBFstandard vs. MBFToF : -0.07 ± 0.10; MBFapical VOI : -0.27 ± 0.25; MBFlarge VOI : -0.11 ± 0.10; MBFHutchins : -0.08 ± 0.10; MBFKrivokapich : -0.47 ± 0.50). CONCLUSIONS: Quantification of MBF from 13 N-NH3 PET images is more affected by choice of compartment models, ToF and blood pool VOIs than by different time frame schemes and reconstruction algorithms.


Subject(s)
Positron Emission Tomography Computed Tomography , Radiopharmaceuticals , Humans , Positron Emission Tomography Computed Tomography/methods , Positron-Emission Tomography , Coronary Circulation , Algorithms , Image Processing, Computer-Assisted/methods
2.
J Nucl Cardiol ; 30(5): 1935-1946, 2023 10.
Article in English | MEDLINE | ID: mdl-36913172

ABSTRACT

BACKGROUND: The solid-state cadmium-zinc-telluride (CZT) gamma camera for myocardial perfusion single-photon emission computed tomography (MPS) has theoretical advantages compared to the conventional gamma camera technique. This includes more sensitive detectors and better energy resolution. We aimed to explore the diagnostic performance of gated MPS with a CZT gamma camera compared to a conventional gamma camera for detection of myocardial infarct (MI) and assessment of left ventricular (LV) volumes and ejection fraction (LVEF), using cardiac magnetic resonance (CMR) as the reference method. METHODS: Seventy-three patients (26% female) with known or suspected chronic coronary syndrome were examined with gated MPS using both a CZT gamma camera and a conventional gamma camera as well as with CMR. Presence and extent of MI on MPS and late gadolinium enhancement (LGE) CMR was evaluated. For LV volumes, LVEF and LV mass, gated MPS images and cine CMR images were evaluated. RESULTS: MI was found in 42 patients on CMR. The overall sensitivity, specificity, positive and negative predictive values for the CZT and the conventional gamma camera were the same (67%, 100%, 100% and 69%). For infarct size > 3% on CMR, the sensitivity was 82% for the CZT and 73% for the conventional gamma camera, respectively. LV volumes were significantly underestimated by MPS compared to CMR (P ≤ .002 for all measures). The underestimation was slightly less pronounced for the CZT compared to the conventional gamma camera (2-10 mL, P ≤ .03 for all measures). For LVEF, however, accuracy was high for both gamma cameras. CONCLUSION: Differences between a CZT and a conventional gamma camera for detection of MI and assessment of LV volumes and LVEF are small and do not appear to be clinically significant.


Subject(s)
Myocardial Infarction , Myocardial Perfusion Imaging , Humans , Female , Male , Gamma Cameras , Contrast Media , Myocardial Perfusion Imaging/methods , Gadolinium , Tomography, Emission-Computed, Single-Photon/methods , Tellurium , Cadmium , Myocardial Infarction/diagnostic imaging , Perfusion
3.
Diagnostics (Basel) ; 12(9)2022 Aug 30.
Article in English | MEDLINE | ID: mdl-36140502

ABSTRACT

Here, we aimed to develop and validate a fully automated artificial intelligence (AI)-based method for the detection and quantification of suspected prostate tumour/local recurrence, lymph node metastases, and bone metastases from [18F]PSMA-1007 positron emission tomography-computed tomography (PET-CT) images. Images from 660 patients were included. Segmentations by one expert reader were ground truth. A convolutional neural network (CNN) was developed and trained on a training set, and the performance was tested on a separate test set of 120 patients. The AI method was compared with manual segmentations performed by several nuclear medicine physicians. Assessment of tumour burden (total lesion volume (TLV) and total lesion uptake (TLU)) was performed. The sensitivity of the AI method was, on average, 79% for detecting prostate tumour/recurrence, 79% for lymph node metastases, and 62% for bone metastases. On average, nuclear medicine physicians' corresponding sensitivities were 78%, 78%, and 59%, respectively. The correlations of TLV and TLU between AI and nuclear medicine physicians were all statistically significant and ranged from R = 0.53 to R = 0.83. In conclusion, the development of an AI-based method for prostate cancer detection with sensitivity on par with nuclear medicine physicians was possible. The developed AI tool is freely available for researchers.

4.
Clin Med Insights Circ Respir Pulm Med ; 15: 11795484211030159, 2021.
Article in English | MEDLINE | ID: mdl-34349582

ABSTRACT

V/P SPECT from 4 consecutive patients with COVID-19 suggests that ventilation and perfusion images may be applied to diagnose or exclude pulmonary embolism, verify nonsegmental diversion of perfusion from the ventilated areas (dead space ventilation) that may represent inflammation of the pulmonary vasculature, detect the reversed mismatch of poor ventilation and better preserved perfusion (shunt perfusion) in bilateral pulmonary inflammation and indicate redistribution of lung perfusion (antigravitational hyperperfusion) due to cardiac congestion. V/P mismatch and reversed mismatch may be extensive enough to diminish dramatically preserved matching ventilation/perfusion and to induce severe hypoxemia in COVID-19.

5.
J Nucl Cardiol ; 28(6): 2910-2922, 2021 12.
Article in English | MEDLINE | ID: mdl-32451797

ABSTRACT

INTRODUCTION: We investigated if uptake pattern on myocardial perfusion SPECT (MPS) in patients with left bundle branch block (LBBB) is related to myocardial fibrosis, myocardial wall motion, and electrocardiography (ECG) characteristics. METHODS: Twenty-three patients (9 women) with LBBB, examined with MPS and cardiac magnetic resonance (CMR), were included. Tracer uptake on MPS was classified by visual interpretation as typical LBBB pattern (Defect+, n = 13) or not (Defect-, n = 10) and quantitatively. CMR images were evaluated for wall thickness and for myocardial wall motion both by visual assessment and by regional myocardial radial strain from feature tracking, and for presence and location of myocardial fibrosis. ECGs were analyzed regarding QRS duration and the presence of strict criteria for LBBB. RESULTS: Wall thickness was slightly lower in the septum compared to the lateral wall in Defect+ patients (5.6 ± 1.1 vs 6.0 ± 1.3 mm, P = 0.03) but not in Defect- patients (5.6 ± 1.0 vs 5.6 ± 0.9 mm, P = 0.84). Defect+ patients showed a larger proportion of dyskinetic segments in the septum and hyperkinetic segments in the lateral wall compared to Defect- patients (P = 0.006 and P = 0.004, respectively). Decreased myocardial radial strain was associated with decreased tracer uptake by MPS (R = 0.37, P < 0.001). Areas of fibrosis did not match areas with uptake defect on MPS. No differences in ECG variables were seen. CONCLUSION: The heterogeneous regional tracer uptake in some patients with LBBB is related to underlying regional myocardial dyskinesia, wall thickening, and wall thickness rather than stress-induced ischemia, myocardial fibrosis, or specific ECG characteristics.


Subject(s)
Bundle-Branch Block/diagnostic imaging , Bundle-Branch Block/physiopathology , Electrocardiography , Heart/physiopathology , Myocardial Infarction/diagnostic imaging , Myocardial Infarction/physiopathology , Myocardial Perfusion Imaging/methods , Tomography, Emission-Computed, Single-Photon , Aged , Bundle-Branch Block/complications , Female , Humans , Male , Middle Aged , Myocardial Infarction/complications , Retrospective Studies
6.
J Nucl Cardiol ; 28(4): 1664-1672, 2021 08.
Article in English | MEDLINE | ID: mdl-31705424

ABSTRACT

BACKGROUND: Many patients undergo percutaneous coronary intervention (PCI) without the use of non-invasive stress testing prior to treatment. The aim of this study was to determine the potential added value of guiding revascularization by quantitative assessment of myocardial perfusion prior to intervention. METHODS AND RESULTS: Thirty-three patients (10 females) with suspected or established CAD who had been referred for a clinical coronary angiography (CA) with possibility for PCI were included. Adenosine stress and rest 13N-NH3 PET, cardiac magnetic resonance (CMR), and cardiopulmonary exercise test were performed 4 ± 3 weeks before and 5 ± 1 months after CA. The angiographer was blinded to the PET and CMR results. Myocardial flow reserve (MFR) < 2.0 by PET was considered abnormal. A PCI was performed in 19/33 patients. In 41% (11/27) of the revascularized vessel territories, a normal regional MFR was found prior to the PCI and no improvement in MFR was found at follow-up (P = 0.9). However, vessel territories with regional MFR < 2.0 at baseline improved significantly after PCI (P = 0.003). Of the 14 patients not undergoing PCI, four had MFR < 2.0 in one or more coronary territories. CONCLUSION: Assessment of quantitative myocardial perfusion prior to revascularization could lead to more appropriate use of CA when managing patients with stable CAD.


Subject(s)
Coronary Artery Bypass , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/surgery , Myocardial Perfusion Imaging , Percutaneous Coronary Intervention , Positron-Emission Tomography , Aged , Aged, 80 and over , Coronary Angiography , Coronary Artery Disease/physiopathology , Exercise Test , Female , Fractional Flow Reserve, Myocardial/physiology , Humans , Male , Middle Aged , Patient Selection , Prospective Studies , Treatment Outcome
7.
J Nucl Cardiol ; 27(6): 2351-2359, 2020 12.
Article in English | MEDLINE | ID: mdl-30535919

ABSTRACT

BACKGROUND: To relate findings of qualitative evaluation of first-pass perfusion-CMR and anatomical evaluation on coronary angiography (CA) to the reference standard of quantitative perfusion, cardiac PET, in patients with suspected or known stable coronary artery disease (CAD). METHODS AND RESULTS: Forty-one patients referred for CA due to suspected stable CAD, prospectively performed adenosine stress/rest first-pass perfusion-CMR as well as 13N-NH3 PET on the same day, 4 ± 3 weeks before CA. Angiographers were blinded to PET and CMR results. Regional myocardial flow reserve (MFR) < 2.0 on PET was considered pathological. Vessel territories with stress-induced ischemia by CMR or vessels with stenosis needing revascularization had a significantly lower MFR compared to those with no regional stress-induced ischemia or vessels not needing revascularization (P < 0.001). In 4 of 123 vessel territories with stress-induced ischemia by CMR, PET showed a normal MFR. In addition, 12 of 123 vessels that underwent intervention showed normal MFR assessed by PET. CONCLUSION: The limited performance of qualitative assessment of presence of stable CAD with CMR and CA, when related to quantitative 13N-NH3 cardiac PET, shows the need for fully quantitative assessment of myocardial perfusion and the use of invasive flow reserve measurements for CA, to confirm the need of elective revascularization.


Subject(s)
Coronary Angiography/methods , Coronary Artery Disease/diagnostic imaging , Fractional Flow Reserve, Myocardial , Myocardial Ischemia/diagnostic imaging , Positron-Emission Tomography/methods , Adenosine/chemistry , Aged , Aged, 80 and over , Angiography/methods , Coronary Circulation , Coronary Stenosis/physiopathology , Female , Humans , Magnetic Resonance Imaging , Male , Middle Aged , Myocardial Perfusion Imaging/methods , Myocardial Revascularization , Myocardium/pathology , Observer Variation , Prospective Studies , Reference Standards , Tomography, X-Ray Computed
8.
BMC Med Imaging ; 19(1): 81, 2019 10 22.
Article in English | MEDLINE | ID: mdl-31640584

ABSTRACT

BACKGROUND: A new generation of positron emission tomography with computed tomography (PET-CT) was recently introduced using silicon (Si) photomultiplier (PM)-based technology. Our aim was to compare the image quality and diagnostic performance of a SiPM-based PET-CT (Discovery MI; GE Healthcare, Milwaukee, WI, USA) with a time-of-flight PET-CT scanner with a conventional PM detector (Gemini TF; Philips Healthcare, Cleveland, OH, USA), including reconstruction algorithms per vendor's recommendations. METHODS: Imaging of the National Electrical Manufacturers Association IEC body phantom and 16 patients was carried out using 1.5 min/bed for the Discovery MI PET-CT and 2 min/bed for the Gemini TF PET-CT. Images were analysed for recovery coefficients for the phantom, signal-to-noise ratio in the liver, standardized uptake values (SUV) in lesions, number of lesions and metabolic TNM classifications in patients. RESULTS: In phantom, the correct (> 90%) activity level was measured for spheres ≥17 mm for Discovery MI, whereas the Gemini TF reached a correct measured activity level for the 37-mm sphere. In patient studies, metabolic TNM classification was worse using images obtained from the Discovery MI compared those obtained from the Gemini TF in 4 of 15 patients. A trend toward more malignant, inflammatory and unclear lesions was found using images acquired with the Discovery MI compared with the Gemini TF, but this was not statistically significant. Lesion-to-blood-pool SUV ratios were significantly higher in images from the Discovery MI compared with the Gemini TF for lesions smaller than 1 cm (p < 0.001), but this was not the case for larger lesions (p = 0.053). The signal-to-noise ratio in the liver was similar between platforms (p = 0.52). Also, shorter acquisition times were possible using the Discovery MI, with preserved signal-to-noise ratio in the liver. CONCLUSIONS: Image quality was better with Discovery MI compared to conventional Gemini TF. Although no gold standard was available, the results indicate that the new PET-CT generation will provide potentially better diagnostic performance.


Subject(s)
Image Interpretation, Computer-Assisted/instrumentation , Liver/diagnostic imaging , Positron Emission Tomography Computed Tomography/methods , Fluorodeoxyglucose F18/administration & dosage , Humans , Phantoms, Imaging , Signal-To-Noise Ratio , Whole Body Imaging
9.
J Cardiovasc Magn Reson ; 19(1): 78, 2017 Oct 19.
Article in English | MEDLINE | ID: mdl-29047385

ABSTRACT

BACKGROUND: Recent studies have shown that quantification of myocardial perfusion (MP) at stress and myocardial perfusion reserve (MPR) offer additional diagnostic and prognostic information compared to qualitative and semi-quantitative assessment of myocardial perfusion distribution in patients with coronary artery disease (CAD). Technical advancements have enabled fully automatic quantification of MP using cardiovascular magnetic resonance (CMR) to be performed in-line in a clinical workflow. The aim of this study was to validate the use of the automated CMR perfusion mapping technique for quantification of MP using 13N-NH3 cardiac positron emission tomography (PET) as the reference method. METHODS: Twenty-one patients with stable CAD were included in the study. All patients underwent adenosine stress and rest perfusion imaging with 13N-NH3 PET and a dual sequence, single contrast bolus CMR on the same day. Global and regional MP were quantified both at stress and rest using PET and CMR. RESULTS: There was good agreement between global MP quantified by PET and CMR both at stress (-0.1 ± 0.5 ml/min/g) and at rest (0 ± 0.2 ml/min/g) with a strong correlation (r = 0.92, p < 0.001; y = 0.94× + 0.14). Furthermore, there was strong correlation between CMR and PET with regards to regional MP (r = 0.83, p < 0.001; y = 0.87× + 0.26) with a good agreement (-0.1 ± 0.6 ml/min/g). There was also a significant correlation between CMR and PET with regard to global and regional MPR (r = 0.69, p = 0.001 and r = 0.57, p < 0.001, respectively). CONCLUSIONS: There is good agreement between MP quantified by 13N-NH3 PET and dual sequence, single contrast bolus CMR in patients with stable CAD. Thus, CMR is viable in clinical practice for quantification of MP.


Subject(s)
Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/physiopathology , Magnetic Resonance Imaging/methods , Positron-Emission Tomography/methods , Aged , Coronary Circulation/physiology , Female , Humans , Male , Reproducibility of Results
10.
J Nucl Cardiol ; 24(6): 1912-1921, 2017 12.
Article in English | MEDLINE | ID: mdl-27506700

ABSTRACT

BACKGROUND: Large body size can cause a higher proportion of emitted photons being attenuated within the patient. Therefore, clinical myocardial perfusion SPECT (MPS) protocols often include unproportionally higher radioisotope activity to obese patients. The aim was to evaluate if a linear weight-adjusted low-dose protocol can be applied to obese patients and thereby decrease radiation exposure. METHODS AND RESULT: Two hundred patients (>110 kg, BMI 18-41, [n = 69], ≤ 110 kg, BMI 31-58, [n = 131]) underwent 99mTc-tetrofosmin stress examination on a Cadmium Zinc Telluride or a conventional gamma camera using new generations of reconstruction algorithm (Resolution Recovery). Patients <110 kg were administered 2.5 MBq/kg, patients between 110 and 120 kg received 430 MBq and patients >120 kg received 570 MBq according to clinical routine. Patients >110 kg had 130% total number of counts in the images compared to patients <110 kg. Recalculating the counts to correspond to an administered activity of 2.5 MBq/kg resulted in similar number of counts across the groups. Image analyses in a subgroup with images corresponding to high activity and 2.5 MBq/kg showed no difference in image quality or ischemia quantification. CONCLUSION: Linear low-dose weight-adjusted protocol of 2.5 MBq/kg in MPS can be applied over a large weight span without loss of counts or image quality, resulting in a significant reduction in radiation exposure to obese patients.


Subject(s)
Myocardial Perfusion Imaging , Overweight/diagnostic imaging , Radiation Dosage , Tomography, Emission-Computed, Single-Photon , Aged , Body Weight , Clinical Protocols , Female , Humans , Male , Middle Aged , Organophosphorus Compounds , Organotechnetium Compounds , Radiation Exposure
11.
J Electrocardiol ; 49(3): 307-15, 2016.
Article in English | MEDLINE | ID: mdl-27055936

ABSTRACT

BACKGROUND: Evaluation of stress-induced ST deviations constitutes a central part when interpreting the findings from an exercise test. The aim of this analysis was to assess the pathophysiologic correlate of stress-induced ST elevation and ST depression with regard to presence, amount and location of myocardial ischemia as assessed by myocardial perfusion SPECT (MPS) in patients with suspected coronary artery disease. METHODS AND RESULTS: 226 patients who had undergone bicycle stress test in conjunction with MPS were included. Of these, 198 were consecutive patients while 28 patients were included on the basis of having stress-induced ST elevation mentioned in their clinical report. The amount and location of ST changes were related to MPS findings. Summed stress scores (SSS) from MPS images were used to measure the amount of stress-induced ischemia. The positive predictive values for detecting stress-induced ischemia were 28% for the consecutive patients with ST depression and 75% for patients with ST elevation. The maximum and sum of stress-induced ST elevations correlated with SSS (r(2)=0.58, p<0.001 and r(2)=0.73, p<0.001), whereas the maximum and sum of significant ST depressions did not (r(2)=0.022, p=0.08 and r(2)=0.024, p=0.10). The location of ST elevation corresponded to the location of ischemia by MPS (kappa=1.0), whereas the location of ST depression did not (kappa=0.20). CONCLUSIONS: Stress-induced ST elevation, with or without concomitant ST depression, is predictive of the presence, amount and location of myocardial ischemia assessed by MPS, whereas stress-induced ST depression without concomitant ST elevation is not.


Subject(s)
Electrocardiography/methods , Exercise Test/methods , Image Interpretation, Computer-Assisted/methods , Myocardial Perfusion Imaging/methods , ST Elevation Myocardial Infarction/diagnostic imaging , Severity of Illness Index , Tomography, Emission-Computed, Single-Photon/methods , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Reproducibility of Results , Sensitivity and Specificity , Statistics as Topic
12.
J Nucl Cardiol ; 21(4): 695-702, 2014 Aug.
Article in English | MEDLINE | ID: mdl-24807623

ABSTRACT

INTRODUCTION: Myocardial perfusion single photon emission computed tomography (MPS) is one of the most widely used diagnostic methods in patients with suspected ischemic heart disease (IHD). Recently, a novel technique based on cadmium-zinc-telluride (CZT) detectors, pinhole collimators, and a stationary gantry was introduced for MPS. The aim of this work was to investigate how patient positioning affects the reconstructed MPS images using this novel technique. MATERIALS AND METHODS: Eighteen patients referred for a clinical MPS due to suspected IHD were included in the study. All patients underwent MPS imaging on a GE Discovery NM 530c CZT camera. After image acquisition with the heart positioned in the center of the quality field of view (QFOV), the patients were re-imaged in different positions 5-20 mm off-center. The heart was still positioned within the limits of the QFOV during the off-center scans. The summed stress score and/or the summed rest score (SSS and/or SRS) for the acquisition performed in the center was compared to the same parameter for the acquisitions performed off-center. RESULTS: There was a statistically significant increase in SSS and/or SRS when imaging was performed with the heart 5-20 mm outside the center of the QFOV compared to optimal positioning (7.7 ± 1.3 vs 6.6 ± 1.3, P = .006). The SSS and/or SRS increased with ≥2 U in 35% (14/40) of the off-center examinations. CONCLUSION: It is important to carefully position the patient's heart within the center of the QFOV when performing MPS with the Discovery NM 530c CZT camera to avoid positioning-related image artifacts that could affect the diagnostic accuracy.


Subject(s)
Gamma Cameras , Myocardial Perfusion Imaging/methods , Patient Positioning , Tomography, Emission-Computed, Single-Photon/methods , Aged , Aged, 80 and over , Cadmium , Female , Humans , Male , Middle Aged , Tellurium , Zinc
13.
J Nucl Cardiol ; 20(5): 797-803, 2013 Oct.
Article in English | MEDLINE | ID: mdl-23835903

ABSTRACT

BACKGROUND: The aim was to determine the sensitivity and specificity of gated myocardial perfusion SPECT (MPS) with a technetium-labelled (Tc) perfusion tracer to detect myocardial infarction (MI) in a clinical population referred for assessment of stress-induced ischemia using late gadolinium enhancement cardiac magnetic resonance (CMR) as reference method. METHODS: 119 patients referred for evaluation of stress-induced ischemia with MPS were included. 108 patients (age 62 ± 10 years, 39% females) completed MPS and CMR. A 2-day protocol for MPS was used for most patients (n = 105). RESULTS: MI was found in 31 patients (29%) using MPS and in 30 patients using CMR (28%). The sensitivity and specificity on a patient basis were 93% and 96%, respectively. Positive predictive value (PPV) was 90% and negative predictive value (NPV) was 97%. Per territory, the sensitivity and specificity for LAD infarcts were 83% and 97%, respectively. PPV was 77% and NPV was 98% for LAD infarcts. The sensitivity and specificity for RCA/LCx infarcts were 95% and 95%, respectively. PPV was 84% and NPV was 99% for RCA/LCx infarcts. The MI size on CMR was 12.0 ± 7.3% of the LV and mean transmurality was 66.3 ± 12.0%. All MI > 3% were detected on gated SPECT. CONCLUSION: This study has demonstrated high sensitivity and specificity for gated Tc-MPS detecting subendocardial and transmural MI.


Subject(s)
Gadolinium , Magnetic Resonance Imaging , Myocardial Infarction/diagnostic imaging , Myocardial Perfusion Imaging , Myocardium/pathology , Tomography, Emission-Computed, Single-Photon , Aged , Contrast Media , Female , Heart/diagnostic imaging , Humans , Image Processing, Computer-Assisted , Male , Middle Aged , Organophosphorus Compounds , Organotechnetium Compounds , Predictive Value of Tests , Radiopharmaceuticals , Risk , Sensitivity and Specificity , Time Factors
14.
J Electrocardiol ; 46(3): 197-203, 2013.
Article in English | MEDLINE | ID: mdl-23540511

ABSTRACT

BACKGROUND: Many graphical methods for displaying ST-segment deviation in the ECG have been tried for enhancing decision-making in patients with suspected acute coronary syndromes. Computed electrocardiographic imaging (CEI), based on a mathematical inverse solution, has been recently applied to transform ST-J point measurements made in conventional 12-lead ECG into a display of epicardial potentials in bull's-eye format. The purpose of this study is to assess utility of CEI in the clinical setting. METHODS: In 99 patients with stable coronary disease, 12-lead ECGs were recorded during elective percutaneous coronary intervention (PCI), first before balloon-catheter insertion and then when an intracoronary balloon blocked blood supply to a region of myocardium for more than 4minutes (typically 5minutes). Four groups of patients were additionally studied, namely those with preexcitation, pericarditis, early repolarization syndrome (ERS), and left ventricular hypertrophy (LVH) with strain. Comparisons between performances of published criteria for ST-elevation myocardial infarction (STEMI) and quantitative as well as visual assessment of CEI images were based on sensitivities and specificities. RESULTS: Visual assessment of CEI outperformed STEMI criteria. This was especially evident for the capability of detecting LCx occlusion with sensitivities for STEMI criteria=35% and for visual assessment of CEI by 2 physicians=71%, i. e. twice as many patients were correctly identified by CEI. False positive rates for CEI were low in patients with LVH with strain as well as with preexcitation for both methods. For pericarditis and ERS, visual as well as quantitative assessment of CEI performed better than STEMI criteria. CONCLUSION: Visual assessment of CEI is a promising method for increasing the accuracy of ECG-based triage to PCI or conservative care.


Subject(s)
Algorithms , Body Surface Potential Mapping/methods , Coronary Occlusion/diagnosis , Diagnosis, Computer-Assisted/methods , Electrocardiography/methods , Image Interpretation, Computer-Assisted/methods , Adolescent , Adult , Aged , Aged, 80 and over , Child , Female , Humans , Male , Middle Aged , Reproducibility of Results , Sensitivity and Specificity , User-Computer Interface , Young Adult
15.
J Nucl Cardiol ; 20(1): 38-44, 2013 Feb.
Article in English | MEDLINE | ID: mdl-23143809

ABSTRACT

BACKGROUND: For a 1-day myocardial perfusion SPECT (MPS) the recommendations for administered activity stated in the EANM guidelines results in an effective dose of up to 16 mSv per patient. Recently, a gamma camera system, based on cadmium zinc telluride (CZT) technology, was introduced. This technique has the potential to reduce the effective dose and scan time compared to the conventional NaI gamma camera. The aim of this study was to investigate if the effective dose can be reduced with a preserved image quality using CZT technology in MPS. METHODS: In total, 150 patients were included in the study. All underwent a 1-day (99m)Tc-tetrofosmin stress-rest protocol and were divided into three subgroups (n = 50 in each group) with 4, 3, and 2.5 MBq/kg body weight of administered activity in the stress examination, respectively. The acquisition time was increased in proportion to the decrease in administered activity. All examinations were analyzed for image quality by visual grading on a 4-point scale (1 = poor, 2 = adequate, 3 = good, 4 = excellent), by two expert readers. RESULTS: The total effective dose (stress + rest) decreased from 9.3 to 5.8 mSv comparing 4 to 2.5 MBq/kg body weight. For the patients undergoing stress examination only (35%) the effective dose, administrating 2.5 MBq/kg, was 1.4 mSv. The image acquisition times for 2.5 MBq/kg body weight were 475 and 300 seconds (stress and rest) compared to 900 seconds for each when using conventional MPS. The average image quality was 3.7 ± 0.5, 3.8 ± 0.5, and 3.8 ± 0.4 for the stress images and 3.5 ± 0.6, 3.6 ± 0.6, and 3.5 ± 0.6 for the rest images and showed no statistically significant difference (P = .62) among the 4, 3, and 2.5 MBq/kg groups. CONCLUSIONS: The new CZT technology can be used to considerably decrease the effective dose and acquisition time for MPS with preserved high image quality.


Subject(s)
Gamma Cameras , Image Processing, Computer-Assisted/methods , Tomography, Emission-Computed, Single-Photon/methods , Aged , Body Weight , Cadmium/chemistry , Coronary Artery Disease/diagnosis , Coronary Artery Disease/diagnostic imaging , Female , Humans , Likelihood Functions , Male , Middle Aged , Myocardial Perfusion Imaging/instrumentation , Myocardial Perfusion Imaging/methods , Organophosphorus Compounds , Organotechnetium Compounds , Perfusion , Radiation Dosage , Radiometry , Radiopharmaceuticals , Tellurium/chemistry , Time Factors , Tomography, Emission-Computed, Single-Photon/instrumentation , Treatment Outcome , Zinc/chemistry
16.
J Nucl Cardiol ; 18(5): 874-85, 2011 Oct.
Article in English | MEDLINE | ID: mdl-21761374

ABSTRACT

BACKGROUND: By gating image acquisition in myocardial perfusion SPECT (MPS) to ECG, left ventricular (LV) volumes and function can be determined. Several previous studies have shown that existing MPS software packages underestimate LV volumes compared to cardiac magnetic resonance (CMR). The aim of this study was therefore to develop a new LV segmentation algorithm for gated MPS using CMR as reference standard. METHODS AND RESULTS: A total of 126 patients with suspected coronary artery disease, who underwent both gated MPS and CMR were retrospectively included. The proposed LV segmentation algorithm (Segment) was trained in 26 patients, and tested in 100 patients in comparison to four commercially available MPS software packages (QGS, MyoMetrix, ECTb, and Exini) using CMR as reference standard. Mean bias ± SD between MPS and CMR was for EDV -5% ± 12%, -43% ± 8%, -40% ± 8%, -42% ± 9%, -32% ± 7%, for ESV 0% ± 17%, -41% ± 16%, -34% ± 15%, -54% ± 13%, -41% ± 10%, for EF -2% ± 13%, -1% ± 14%, -7% ± 15%, 17% ± 16%, 10% ± 17% for Segment, QGS, MyoMetrix, ECTb, and Exini, respectively, and for LVM 3% ± 18%, 33% ± 25%, 37% ± 24% for Segment, QGS, and ECTb, respectively. Correlation between MPS by Segment and CMR were for EDV R (2) = 0.89, for ESV R (2) = 0.92, for EF R (2) = 0.69, and for LVM R (2) = 0.72, with no difference compared to the correlation between the other MPS software packages and CMR (EDV R (2) = 0.86-0.92, ESV R (2) = 0.91-0.93, EF R (2) = 0.64-0.65, and LVM R (2) = 0.68-0.70). CONCLUSION: The Segment software quantifies LV volumes and EF by MPS with similar correlation and a low bias compared to other MPS software packages, using CMR as reference standard. Hence, the Segment software shows potential to provide clinically relevant volumes and functional values from MPS.


Subject(s)
Magnetic Resonance Imaging , Myocardial Perfusion Imaging/standards , Tomography, Emission-Computed, Single-Photon/standards , Ventricular Function, Left , Adult , Aged , Algorithms , Female , Humans , Linear Models , Male , Middle Aged , Reference Standards , Retrospective Studies , Software
17.
BMC Med Imaging ; 10: 10, 2010 May 25.
Article in English | MEDLINE | ID: mdl-20500866

ABSTRACT

BACKGROUND: We sought to compare quantification of left ventricular volumes and ejection fraction by different gated myocardial perfusion SPECT (MPS) programs with each other and to magnetic resonance (MR) imaging. METHODS: N = 100 patients with known or suspected coronary artery disease were examined at rest with 99 mTc-tetrofosmin gated MPS and cardiac MR imaging. Left ventricular end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV) and ejection fraction (EF) were obtained by analysing gated MPS data with four different programs: Quantitative Gated SPECT (QGS), GE MyoMetrix, Emory Cardiac Toolbox (ECTb) and Exini heart. RESULTS: All programs showed a mean bias compared to MR imaging of approximately -30% for EDV (-22 to -34%, p < 0.001 for all), ESV (-12 to -37%, p < 0.001 for ECTb, p < 0.05 for Exini, p = ns for QGS and MyoMetrix) and SV (-21 to -41%, p < 0.001 for all). Mean bias +/- 2 SD for EF (% of EF) was -9 +/- 27% (p < 0.01), 6 +/- 29% (p = ns), 15 +/- 27% (p < 0.001) and 0 +/- 28% (p = ns) for QGS, ECTb, MyoMetrix, and Exini, respectively. CONCLUSIONS: Gated MPS, systematically underestimates left ventricular volumes by approximately 30% and shows a high variability, especially for ESV. For EF, accuracy was better, with a mean bias between -15 and 6% of EF. It may be of value to take this into consideration when determining absolute values of LV volumes and EF in a clinical setting.


Subject(s)
Gated Blood-Pool Imaging/methods , Image Interpretation, Computer-Assisted/methods , Magnetic Resonance Imaging, Cine/methods , Software , Stroke Volume , Tomography, Emission-Computed, Single-Photon/methods , Ventricular Dysfunction, Left/diagnosis , Adult , Aged , Algorithms , False Negative Reactions , Female , Humans , Image Enhancement/methods , Imaging, Three-Dimensional/methods , Male , Middle Aged , Pattern Recognition, Automated/methods , Perfusion Imaging/methods , Reproducibility of Results , Sensitivity and Specificity , Software Validation
SELECTION OF CITATIONS