Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 18 de 18
Filter
Add more filters










Publication year range
1.
J Environ Manage ; 342: 118214, 2023 Sep 15.
Article in English | MEDLINE | ID: mdl-37311345

ABSTRACT

Package plants (PP) are implemented around the world to provide on-site sanitation in areas not connected to a sewage network. The efficiency of PP has not been comprehensively studied at full scale, and the limited number of available studies have shown that their performance varies greatly. Their performance under cold climate conditions and the occurrence of micropollutants in PP effluents have not been sufficiently explored. PP are exposed to environmental factors such as low temperature, especially in cold regions with low winter temperatures and deep frost penetration, that can adversely influence the biochemical processes. The aim of this study was to investigate the treatment efficiency and possible effects of cold temperatures on PP performance, with focus on traditional contaminants (organics, solids, nutrients and indicator bacteria) and an additional assessment of micropollutants on two PP. Eleven PP hosting different treatment processes were monitored. Removal of biological oxygen demand (BOD) was high in all plants (>91%). Six out of the 11 PP provided good phosphorus removal (>71%). Small degrees of nitrification were observed in almost all the facilities, despite the low temperatures, while denitrification was only observed in two plants which achieved the highest nitrification rates (>51%) and had sludge recirculation. No strong correlation between wastewater temperature and BOD, nutrients and indicator bacteria concentration in the effluents was found. The high data variability and the effects of other process parameters as well as snow-melt water infiltration are suggested as possible reasons for the lack of correlation. However, weak negative relations between effluent concentrations and wastewater temperatures were detected in specific plants, indicating that temperature does have effects. When managed adequately, package plants can provide high BOD and phosphorus removal, but nitrogen and bacteria removal remain challenging, especially at low temperatures. Pharmaceutical compounds were detected in the effluents at concentrations within or above ranges reported for large treatment plants while phthalate ester concentrations were below commonly reported effluent concentrations.


Subject(s)
Wastewater , Water Purification , Waste Disposal, Fluid , Cold Climate , Sewage/chemistry , Nitrification , Phosphorus , Bacteria , Nitrogen , Bioreactors , Denitrification
2.
J Environ Manage ; 340: 117949, 2023 Aug 15.
Article in English | MEDLINE | ID: mdl-37167081

ABSTRACT

Bioretention systems for urban drainage are one type of blue-green infrastructure that have gained more attention in recent decades. There are numerous design options for these systems, including various construction components, filter material mixtures, and plants. However, the research focus on the impacts of these many design options has mainly been technical, i.e., how different bioretention designs affect runoff pollution treatment and hydraulic control. Knowledge of the effects of various design elements on other sustainability criteria, such as economic, social, and environmental aspects, needs to be developed. This research aimed to evaluate and compare various design elements and bioretention types to gain a better understanding of the relative sustainability of various bioretention systems. This was accomplished by identifying relevant criteria and sub-criteria, covering social, economic, and technical-environmental indicators, in a multicriteria analysis. To evaluate the sustainability performance of various bioretention designs, 12 sub-criteria were allotted -100 to 100 points in a scoring process. The main finding was that while design features had a major impact on bioretention performance, no single design configuration excelled in all criteria. High scores in the social criteria were correlated with the use of trees and smaller volumes of pumice in the filter material mixture. In the economic criteria, extensive use of concrete and a complex mixture of filter material increased the costs. The system with a water-saturated zone and a variety of plant species outperformed the other systems in the technical-environmental criteria. The results can be utilized as a reference to assess design configurations that best satisfy specific needs for each unique bioretention implementation.


Subject(s)
Nitrogen , Rain , Nitrogen/analysis , Plants , Environmental Pollution , Trees
3.
Water Res ; 236: 119912, 2023 Jun 01.
Article in English | MEDLINE | ID: mdl-37037179

ABSTRACT

Due to structural and hydraulic deterioration, urban water pipe networks have annual rehabilitation needs. Worldwide, these needs are often significantly larger than the actual amount of rehabilitation being performed, leading to increased risks of serious failures, lower performance and a growing techno-financial burden for future generations. It is well accepted that, in order to limit the multiple impacts of utility works in the urban environment, rehabilitation projects should be coordinated between water, transport, energy and telecommunication infrastructures. In practice, such coordination means that public utilities must rehabilitate assets earlier or later than technically needed, in order to engage in joint projects in which digging and resurfacing expenditures are shared. Hence, at the municipal scale, such coordination influences two variables that are key to strategic decision support: average costs (€/metre) for asset rehabilitation, and the service lifetimes of those assets. However, current models for strategic asset management do not enable practitioners to estimate how changes in the coordination process may influence the long-term financial and environmental impacts of infrastructure rehabilitation. The present study aimed at addressing this methodological gap by introducing the concept of a coordination window that quantifies to what extent utilities compromise asset rehabilitation times in order to join multi-utility projects. An algorithm for modelling the influence of the coordination window size on long-term sustainability costs is presented and applied to one Swedish municipality. The results suggested that total capital costs and carbon emissions can be lowered by 34% and 16% with a coordination window of 35 and 25 year, in comparison to the no-coordination case.


Subject(s)
Conservation of Natural Resources , Water Supply , Conservation of Natural Resources/methods , Cities
4.
Environ Technol ; 44(11): 1600-1612, 2023 Apr.
Article in English | MEDLINE | ID: mdl-34839790

ABSTRACT

Synthetic stormwater was tested to determine the ageing effects on dissolved metal concentrations and used in a column experiment to determine efficiency of four different filter materials (milkweed, bark, peat, polypropylene) in removing total and dissolved metals. Synthetic stormwater was created by adding metal salts, oil and collected stormwater sediment to tap water. Two ageing experiments were performed to determine the change of synthetic stormwater quality over time. One experiment lasted for 11 days and another focused on rapid concentration changes one day after preparation. The one-day ageing experiment showed rapid decrease in dissolved concentration of certain metals, specifically Cu. To consider this change, correction coefficients for each metal were developed and used to estimate the average dissolved metal concentration in the synthetic stormwater during the experiment to determine filter treatment efficiency. During the 11-day experiment on metal concentrations, no noticeable quality changes were observed for at least six days after the preparation of synthetic stormwater. Furthermore, a column experiment was run with duplicate filter columns. Inflow and outflow samples were analysed for total and dissolved metals, turbidity, particle size distribution, and pH. High removal of total metal concentrations was noticed in all tested filter media (58-94%). Dissolved metal concentration removal varied among different filter media. In general, columns with bark and peat media were able to treat dissolved metals better than polypropylene and milkweed. The level of treatment of dissolved metals between the different filter media columns were bark > peat > milkweed > polypropylene.


Subject(s)
Metals, Heavy , Water Pollutants, Chemical , Water Purification , Polypropylenes , Metals , Soil , Salts , Water Pollutants, Chemical/analysis , Rain , Filtration , Metals, Heavy/analysis
5.
Water Sci Technol ; 86(1): 1-16, 2022 Jul.
Article in English | MEDLINE | ID: mdl-35838279

ABSTRACT

Infiltration and inflow (I/I) into sanitary sewers causes numerous negative effects on the whole wastewater management system and ultimately, on the receiving waters. Consequently, a number of methods have been developed to analyse the performance of sewer systems with respect to I/I, including: distributed temperature sensing (DTS), closed-circuit television (CCTV) inspections, flow and conductivity measurements, automatic or grab sampling of ammonium, smoke testing, and visual inspection of manholes. Such methods were compared in an application to sanitary sewers in a small community and assessed with respect to their accuracy and ability to identify locations of sources of I/I, as well as temporal and spatial resolutions of the obtained results. Furthermore, different approaches to ammonium sampling during I/I monitoring campaigns were discussed. It was concluded that among the methods tested in this study, DTS had the highest temporal and spatial resolution, while ammonium grab sampling showed promise for initial screening of large catchments.


Subject(s)
Ammonium Compounds , Sewage , Wastewater
6.
Water Res ; 199: 117167, 2021 Jul 01.
Article in English | MEDLINE | ID: mdl-34015748

ABSTRACT

The presence of SARS-CoV-2 RNA in wastewater was first reported in March 2020. Over the subsequent months, the potential for wastewater surveillance to contribute to COVID-19 mitigation programmes has been the focus of intense national and international research activities, gaining the attention of policy makers and the public. As a new application of an established methodology, focused collaboration between public health practitioners and wastewater researchers is essential to developing a common understanding on how, when and where the outputs of this non-invasive community-level approach can deliver actionable outcomes for public health authorities. Within this context, the NORMAN SCORE "SARS-CoV-2 in sewage" database provides a platform for rapid, open access data sharing, validated by the uploading of 276 data sets from nine countries to-date. Through offering direct access to underpinning meta-data sets (and describing its use in data interpretation), the NORMAN SCORE database is a resource for the development of recommendations on minimum data requirements for wastewater pathogen surveillance. It is also a tool to engage public health practitioners in discussions on use of the approach, providing an opportunity to build mutual understanding of the demand and supply for data and facilitate the translation of this promising research application into public health practice.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , Public Health , RNA, Viral , Wastewater
7.
Water Res ; 182: 115919, 2020 Sep 01.
Article in English | MEDLINE | ID: mdl-32622122

ABSTRACT

As the understanding of how stormwater pollutants are fractioned and need for mitigation has increased, so has the investigation into more advanced treatment techniques. The present study investigated the treatment efficiency of coagulation/flocculation and sedimentation in semi-synthetic stormwater. Five coagulants were evaluated in terms of reducing particle content, organic carbon, total and dissolved metals, hydrocarbon oil index, and polycyclic aromatic hydrocarbons (PAHs). Changes in the resulting particle size distribution as a consequence of the coagulation treatment were also investigated. The pollutants in the semi-synthetic stormwater were predominantly in the particulate phase. The medium and longer chained hydrocarbons dominated the hydrocarbon oil index, while medium to high molecular weight PAHs were most abundant. Iron chloride was the only coagulant that affected particle size distribution post-treatment, shifting the distribution toward larger particles. In terms of total metal removal, the performance of the coagulants was similar, with over 90% removal on average. Concentration of zdissolved copper, one of the metals found in the dissolved phase, was reduced by 40% via coagulation treatment. The iron chloride coagulant increased dissolved Zn, a change attributed to a considerable drop in pH resulting in higher ion mobility. Similarly, the reduction in organic content (total organic carbon, oil, and PAHs) was over 90% for most coagulants.


Subject(s)
Polycyclic Aromatic Hydrocarbons/analysis , Water Pollutants, Chemical/analysis , Flocculation , Iron , Metals
8.
Water Sci Technol ; 81(2): 274-282, 2020 Jan.
Article in English | MEDLINE | ID: mdl-32333660

ABSTRACT

Stormwater sediments of various sizes and densities are recognised as one of the most important stormwater quality parameters that can be conventionally controlled by settling in detention ponds. The bottom grid structure (BGS) is an innovative concept proposed in this study to enhance removal of stormwater sediments entering ponds and reduce sediment resuspension. This concept was studied in a hydraulic scale model with the objective of elucidating the effects of the BGS geometry on stormwater sediment trapping. Towards this end, the BGS cell size and depth, and the cell cross-wall angle were varied for a range of flow rates, and the sediment trapping efficiency was measured in the model. The main value of the observed sediment trapping efficiencies, in the range from 13 to 55%, was a comparative assessment of various BGS designs. In general, larger cells (footprint 10 × 10 cm) were more effective than the smaller cells (5 × 5 cm), the cell depth exerted small influence on sediment trapping, and the cells with inclined cross-walls proved more effective in sediment trapping than the vertical cross-walls. However, the BGS with inclined cross-walls would be harder to maintain. Future studies should address an optimal cell design and testing in an actual stormwater pond.


Subject(s)
Geologic Sediments , Ponds , Bays
9.
Data Brief ; 21: 1204-1208, 2018 Dec.
Article in English | MEDLINE | ID: mdl-30456233

ABSTRACT

The article presents input data that were used in Pericault et al. (2018) for life cycle impact assessment and total cost assessment of five technical alternatives for heat and water services provision in a suburban development in Sweden. The data consists of a list of environmental impacts (cumulative exergy demand of energy carriers - CExDe, global warming potential - GWP, abiotic depletion potential of elements - ADPE), costs, amortisation periods, lifetimes and output flows of the system processes composing the alternatives. The data was derived from values collected in lifecycle databases, environmental product declarations, scientific publications and personal communications with companies.

10.
Water Sci Technol ; 76(2): 294-301, 2017 Jul.
Article in English | MEDLINE | ID: mdl-28726696

ABSTRACT

The burial of sewer and water pipes below the maximum ground frost depth can be very costly and laborious in regions with cold winters. If a freeze protection measure is applied, the utility lines can be installed in a shallower trench to reduce the excavation needs. One freeze protection measure, so called heat tracing, consists of supplying heat along the pipes. In this work, the use of 4th generation district heating as a heat tracing solution was investigated at a pilot site in Kiruna, Sweden. The influence of the system on sewer and water pipe temperatures was studied at a snow-free and snow-covered cross section. To this end, five heat tracing temperatures were tested and the corresponding sewer and water pipe temperatures were measured. The field experiment was also simulated with a two dimensional finite volume model. The study showed that, under the climatic conditions of the experiment, a heat tracing temperature of 25 °C allowed prevention of freezing of the pipes while keeping drinking water pipes in a safe temperature range at both cross sections. The other main result was that the developed finite volume model of the sections showed a good fitting to the experimental data.


Subject(s)
Drainage, Sanitary/methods , Models, Chemical , Waste Disposal, Fluid/methods , Cold Temperature , Temperature
11.
J Environ Manage ; 161: 188-197, 2015 Sep 15.
Article in English | MEDLINE | ID: mdl-26182992

ABSTRACT

Ever since the advent of major sewer construction in the 1850s, the issue of increased solids deposition in sewers due to changes in domestic wastewater inputs has been frequently debated. Three recent changes considered here are the introduction of kitchen sink food waste disposers (FWDs); rising levels of inputs of fat, oil and grease (FOG); and the installation of low-flush toilets (LFTs). In this review these changes have been examined with regard to potential solids depositional impacts on sewer systems and the managerial implications. The review indicates that each of the changes has the potential to cause an increase in solids deposition in sewers and this is likely to be more pronounced for the upstream reaches of networks that serve fewer households than the downstream parts and for specific sewer features such as sags. The review has highlighted the importance of educational campaigns directed to the public to mitigate deposition as many of the observed problems have been linked to domestic behaviour in regard to FOGs, FWDs and toilet flushing. A standardized monitoring procedure of repeat sewer blockage locations can also be a means to identify depositional hot-spots. Interactions between the various changes in inputs in the studies reviewed here indicated an increased potential for blockage formation, but this would need to be further substantiated. As the precise nature of these changes in inputs have been found to be variable, depending on lifestyles and type of installation, the additional problems that may arise pose particular challenges to sewer operators and managers because of the difficulty in generalizing the nature of the changes, particularly where retrofitting projects in households are being considered. The three types of changes to inputs reviewed here highlight the need to consider whether or not more or less solid waste from households should be diverted into sewers.


Subject(s)
Sewage/chemistry , Waste Disposal, Fluid/methods , Wastewater/chemistry , Water Purification/methods , Household Articles , Humans , Models, Theoretical , Waste Disposal, Fluid/instrumentation , Water Movements
12.
J Environ Manage ; 152: 241-50, 2015 Apr 01.
Article in English | MEDLINE | ID: mdl-25662485

ABSTRACT

Even in separate sewer systems, wastewater may find its way into the receiving waters through stormwater sewers. The main reasons for this are cross-connections, illicit connections, overflows and leakages through broken sewers. Such discharges may affect receiving water quality and increase risks to public health and aquatic organisms. Detecting wastewater contamination and locating its points of ingress into storm sewer systems can be a challenging task, which should be addressed using proper methods and indicator parameters. A number of detection methods have already been proposed in this area, yet there is a lack of a general overview of such methods. This literature review summarizes and evaluates the methods used for detecting wastewater in stormwater, including those recently developed. The advantages, weaknesses and limitations of individual methods are discussed. It is concluded that while no single method can as yet produce results in a precise, fast and inexpensive way, the use of human waste specific chemical and microbiological markers, and their innovative sampling, offer the way forward. Guidance for selecting the most effective combinations of detection methods, under specific conditions, is also provided.


Subject(s)
Environmental Monitoring/methods , Rain , Wastewater/analysis , Water Quality , Wastewater/microbiology
13.
Environ Technol ; 35(21-24): 2643-51, 2014.
Article in English | MEDLINE | ID: mdl-25176297

ABSTRACT

To increase biogas generation and decrease vehicle transportation of solid waste, the integration of food waste disposers (FWDs) into the wastewater system has been proposed. However, concerns have been raised about the long-term impact of the additional load of the FWDs on sewer systems. To examine the said impact, this study has used closed-circuit television inspection techniques to evaluate the status of 181 concrete pipes serving single family housing areas with a diameter of 225 mm, ranging from a 100% connection rate of households with an FWD to none. A minor study was also performed on a multi-family housing area, where mainly plastic pipes (200 mm) were used. The extent and distribution of deposits related to the ratio of FWDs, inclination and pipe sagging (backfalls) were ascertained by using linear regression and analysis of variance. The results showed that FWDs have had an impact on the level of deposits in the sewer, but this has, in turn, been of minor significance. With a high connection rate of FWDs upstream of a pipe, the extent of the total level of deposits, as well as finer sediments, was statistically determined to be greater. However, the majority of the deposits were observed to be small, which would suggest the impact of FWDs on sewer performance to be minor. As food waste not compatible with the FWD was seen in the sewers, educational campaigns could be beneficial to further lower the risks of sewer blocking.


Subject(s)
Drainage, Sanitary , Waste Disposal, Fluid/instrumentation , Biofilms , Fats , Food , Housing , Oils
14.
J Environ Manage ; 146: 29-41, 2014 Dec 15.
Article in English | MEDLINE | ID: mdl-25156263

ABSTRACT

Individual and organisational receptivity for change towards the use of sustainable stormwater management systems has been previously examined, but the significance of the different contexts for achieving this has been largely unexplored. This paper examines the significance of contexts associated to the actions to bring this about by proposing and evaluating an emerging framework based on two related receptivity theories: the individual or organisational approach and the contextual approach. Results from a Swedish national questionnaire with professionals in stormwater management have been used, together with a limited number of interviews to develop and understand the validity of the framework. The analysis has indicated that the respondents were professionally prepared for change (action) but not practically prepared due to inadequate supportive contexts. In response, a number of potential contexts associated to the necessary actions were identified. The framework was found to provide new insights into the influence of receptive contexts for a change in water management practice. These insights can be used by policy makers and others to better support the realization of professional openness for change and thus accelerate the process of change to sustainable stormwater practice.


Subject(s)
Policy , Rain , Water Movements , Water Supply , Conservation of Natural Resources , Humans , Surveys and Questionnaires , Sweden , Urban Health
15.
Chemosphere ; 117: 360-6, 2014 Dec.
Article in English | MEDLINE | ID: mdl-25155452

ABSTRACT

P-sorbing filter beds appear to be viable options for treating wastewater to reduce P discharges and recover this non-renewable resource. However, greater knowledge of filters' responses to temperature variations is required to assess their likely performance in full-scale applications and facilitate the transfer of laboratory results to the field. Thus, in the present study two filter materials (Top16 and Polonite) were characterized physicochemically and effects of temperature on their performance were investigated under controlled laboratory conditions. Using a 2(2) factorial design and secondary wastewater eight filter columns were tested at temperatures of 4.3°C and 16.5°C. Temperature significantly (α=0.05) and strongly affected the P binding capacity of both materials, as it was 1.2- and 1.5-fold higher at 16.5°C than at 4.3°C for Top16 and Polonite, respectively. This is probably due to the enhanced precipitation of calcium phosphates at higher temperature. Observed reductions in total organic carbon content in the wastewater were also positively correlated with temperature, while the pH and reduction of dissolved organic carbon remained unaffected. The physicochemical analyses indicated that several calcium phases dissolved from the filter materials, primarily gypsum and bassanite from Top16 and Portlandite from Polonite. No clear evidence of any crystalline calcium phosphates was observed in the used materials. The results clearly show that temperature strongly influences the retention of P in filters and its effects should be carefully considered before using candidate filters in full-scale applications.


Subject(s)
Filtration/methods , Phosphorus/chemistry , Waste Disposal, Fluid/methods , Calcium Compounds/chemistry , Ferrous Compounds/chemistry , Oxides/chemistry , Temperature
16.
J Contam Hydrol ; 154: 70-7, 2013 Nov.
Article in English | MEDLINE | ID: mdl-24090737

ABSTRACT

Phosphorus filter units containing mineral-based sorbents with a high phosphate (PO4) binding capacity have been shown to be appropriate for removing PO4 in the treatment of domestic wastewater in on-site facilities. However, a better understanding of their PO4 removal mechanisms, and reactions that could lead to the formation of PO4 compounds, is required to evaluate the potential utility of candidate sorbents. Models based on data obtained from laboratory-scale experiments with columns of selected materials can be valuable for acquiring such understanding. Thus, in this study the transport and removal of PO4 in experiments with a laboratory-scale column filled with a commercial silicate-based sorbent were modeled, using the hydro-geochemical transport code PHREEQC. The resulting models, that incorporated the dissolution of calcite, kinetic constrains for the dissolution of calcium oxide (CaO) and wollastonite (CaSiO3), and the precipitation of amorphous tricalcium phosphate, Ca3(PO4)2, successfully simulated the removal of PO4 observed in the experiments.


Subject(s)
Models, Theoretical , Phosphates/chemistry , Waste Disposal, Fluid , Water Pollutants, Chemical/chemistry , Adsorption , Calcium Carbonate/chemistry , Calcium Compounds/chemistry , Filtration , Oxides/chemistry , Silicates/chemistry , Silicon Dioxide/chemistry , Wastewater/chemistry
17.
PLoS One ; 8(8): e69017, 2013.
Article in English | MEDLINE | ID: mdl-23936313

ABSTRACT

Sorption by active filter media can be a convenient option for phosphorus (P) removal and recovery from wastewater for on-site treatment systems. There is a need for a robust laboratory method for the investigation of filter materials to enable a reliable estimation of their longevity. The objectives of this study were to (1) investigate and (2) quantify the effect of hydraulic loading rate and influent source (secondary wastewater and synthetic phosphate solution) on P binding capacity determined in laboratory column tests and (3) to study how much time is needed for the P to react with the filter material (reaction time). To study the effects of these factors, a 2(2) factorial experiment with 11 filter columns was performed. The reaction time was studied in a batch experiment. Both factors significantly (α = 0.05) affected the P binding capacity negatively, but the interaction of the two factors was not significant. Increasing the loading rate from 100 to 1200 L m(-2) d(-1) decreased P binding capacity from 1.152 to 0.070 g kg(-1) for wastewater filters and from 1.382 to 0.300 g kg(-1) for phosphate solution filters. At a loading rate of 100 L m(-2) d(-1), the average P binding capacity of wastewater filters was 1.152 g kg(-1) as opposed to 1.382 g kg(-1) for phosphate solution filters. Therefore, influent source or hydraulic loading rate should be carefully controlled in the laboratory. When phosphate solution and wastewater were used, the reaction times for the filters to remove P were determined to be 5 and 15 minutes, respectively, suggesting that a short residence time is required. However, breakthrough in this study occurred unexpectedly quickly, implying that more time is needed for the P that has reacted to be physically retained in the filter.


Subject(s)
Chemical Phenomena , Filtration/methods , Phosphorus/metabolism , Waste Disposal, Fluid/methods , Water Purification/methods , Phosphorus/isolation & purification
18.
Environ Technol ; 33(7-9): 1013-9, 2012.
Article in English | MEDLINE | ID: mdl-22720428

ABSTRACT

Recent guidelines from the Swedish Environmental Protection Agency recommend stricter regulations for phosphorus (P) reduction in small-scale wastewater treatment, which raises the need for additional and novel treatment steps in small-scale facilities. Following a biological pretreatment, filter systems can be a convenient option. In this study, the P binding capacity of the filter material Filtra P was investigated in batch tests. The batch test method was evaluated with respect to the effects of liquid-to-solid ratio and particle size on P binding capacity. For initial concentrations (c(i)) between 3 and 100 mg L(-1), the P in the solution was completely and rapidly bound to the material, indicating that Filtra P was an efficient substrate for this process. The maximum amount of bound P was 4.3 +/- 0.64 g kg(-1) at c(i) = 300 mg L(-1). The P binding capacity and turbidity measured in the supernatant correlated positively. Turbidity was probably caused by calcium-P precipitates, suggesting precipitation was the major removal mechanism. Neither the liquid-to-solid ratio nor the particle size affected P binding capacity significantly (alpha = 0.05) at c(i) = 1000 mg L(-1), confirming that the conditions used in the batch tests were appropriate. In full-scale applications, the precipitate formed may be at risk of being washed out of the filter, leading to low total P reduction and recovery.


Subject(s)
Calcium Compounds/chemistry , Filtration , Phosphorus/chemistry , Waste Disposal, Fluid/methods , Particle Size
SELECTION OF CITATIONS
SEARCH DETAIL
...