2.
Article in English | MEDLINE | ID: mdl-38864809

ABSTRACT

BACKGROUND: Atrial fibrillation (AF) and heart failure (HF) coexist, increasing morbidity and mortality. Studies have demonstrated improved outcomes following AF ablation in HF patients with reduced ejection fraction (EF). OBJECTIVE: This study sought to assess the outcomes of pulsed field ablation (PFA) in HF. METHODS: MANIFEST-PF (Multi-National Survey on the Methods, Efficacy, and Safety on the Post-Approval Clinical Use of Pulsed Field Ablation) is a multicenter, patient-level registry of consecutive patients undergoing PFA for paroxysmal AF or persistent AF (PerAF). In this substudy, patients were stratified as no history of HF (no-HF), HF with preserved EF (HFpEF) (left ventricular EF of ≥50%) or HF with reduced/mildly reduced EF (HFmr/rEF) (left ventricular EF of <50%). The primary effectiveness and safety endpoints were freedom from documented atrial arrhythmias lasting ≥30 seconds and major adverse events, respectively. RESULTS: Of the 1,381 patients, 85% (n = 1,174) were no-HF, 6.2% (n = 87) were HFpEF, and 8.6% (n = 120) were HFmr/rEF. No-HF patients had less PerAF than patients with HF (P < 0.001), with no difference between HF subtypes (P = >0.99). The 1-year freedom from atrial arrhythmia was significantly higher in no-HF patients than in those with HFpEF or HFmr/rEF (79.9%, 71.3%, and 67.5%, respectively; P < 0.001) but similar between patients with HFmr/rEF and HFpEF (P = 0.26). However, there was no significant difference in freedom from atrial arrhythmia among patients with no-HF vs HFpEF vs HFmr/rEF for those with paroxysmal AF (82.8%, 82.4%, and 71.7%, respectively; P = 0.09) and PerAF (73.3%, 64.2%, and 64.9%, respectively; P = 0.14). Major adverse event rates were similar between the no-HF, HFpEF, and HFmr/rEF groups (1.9%, 0%, and 2.5%, respectively). CONCLUSIONS: PFA appears to be potentially safe and effective in AF patients with HF. Freedom from atrial arrhythmia post-PFA was higher in patients without a history of HF, with no significant difference between HF subtypes.

5.
Article in English | MEDLINE | ID: mdl-38869506

ABSTRACT

BACKGROUND: Atrial fibrillation (AF) and heart failure (HF) coexist, increasing morbidity and mortality. Studies have demonstrated improved outcomes following AF ablation in HF patients with reduced ejection fraction (EF). OBJECTIVE: To assess the outcomes of pulsed-field ablation (PFA) in HF. METHODS: MANIFEST-PF is a multicenter patient-level registry of consecutive patients undergoing PFA for paroxysmal (PAF) or persistent AF (PerAF). In this sub-study, patients were stratified as: no history of HF (no-HF), HF with preserved EF (HFPEF; LVEF≥50%) or HF with reduced/mildly-reduced EF (HFMR/REF; LVEF<50%). The primary effectiveness and safety endpoints were freedom from documented atrial arrhythmias lasting ≥30s and major adverse events (MAEs), respectively. RESULTS: Of the 1,381 patients, 85% (n=1,174) were no-HF, 6.2% (n=87) were HFPEF, and 8.6% (n=120) were HFMR/REF. No-HF patients had less PerAF than patients with HF (p<0.001), with no difference between HF subtypes (p=1.00). The 1-year freedom from atrial arrhythmia was significantly higher in no-HF than with HFPEF or HFMR/REF (79.9%, 71.3%, 67.5%, p<0.001), but similar between HFMR/REF and HFPEF (p=0.26). However, there was no significant difference in freedom from atrial arrhythmia among patients with no-HF vs HFPEF vs HFMR/REF for those with PAF (82.8%/82.4%/71.7%, p=0.09) and PerAF (73.3%, 64.2%, and 64.9%, p=0.14.MAE rates were similar between the no-HF, HFPEF and HFMR/REF groups (1.9%, 0%, and 2.5%, respectively). CONCLUSION: PFA appears to be potentially safe and effective in AF patients with HF. Freedom from atrial arrhythmia post-PFA was higher in patients without a history of HF, with no significant difference between HF subtypes.

7.
Herzschrittmacherther Elektrophysiol ; 35(2): 155-164, 2024 Jun.
Article in German | MEDLINE | ID: mdl-38748284

ABSTRACT

The implantation of electrodes for cardiac implantable electronic devices (CIED) requires profound technical understanding and precise execution. The positioning of electrodes in the right ventricle and atrium has significant implications for patient safety and the effectiveness of CIED therapy. Particular focus is given to the distinction between apical and septal stimulation in ventricular positioning. Based on current data, this article provides a practice-oriented guide that leads implanters through the individual steps of electrode positioning. The implantation of electrodes for physiological stimulation (cardiac resynchronization therapy, CRT, and conduction system pacing, CSP) is not addressed in this article.


Subject(s)
Cardiac Surgical Procedures , Electrodes, Implanted , Humans , Evidence-Based Medicine , Prosthesis Implantation/methods , Cardiac Surgical Procedures/instrumentation , Cardiac Surgical Procedures/methods
8.
Eur Heart J Digit Health ; 5(3): 356-362, 2024 May.
Article in English | MEDLINE | ID: mdl-38774365

ABSTRACT

Aims: Electroanatomical mapping (EAM) systems are essential for the treatment of cardiac arrhythmias. The EAM system is usually operated by qualified staff or field technical engineers from the control room. Novel remote support technology allows for remote access of EAM via online services. Remote access increases the flexibility of the electrophysiological lab, reduces travel time, and overcomes hospital access limitations especially during the COVID-19 pandemic. Here, we report on the feasibility and safety of EAM remote access for cardiac ablation procedures. Methods and results: Mapping and ablation were achieved by combining the EnsiteX™ EAM system and the integrated Ensite™ Connect Remote Support software, together with an integrated audiovisual solution system for remote support (Medinbox). Communication between the operator and the remote support was achieved using an incorporated internet-based common communication platform (Zoom™), headphones, and high-resolution cameras. We investigated 50 remote access-assisted consecutive electrophysiological procedures from September 2022 to February 2023 (remote group). The data were compared with matched patients (n = 50) with onsite support from the control room (control group). The median procedure time was 100 min (76, 120; remote) vs. 86 min (60, 110; control), P = 0.090. The procedural success (both groups 100%, P = 0.999) and complication rate (remote: 2%, control: 0%, P = 0.553) were comparable between the groups. Travel burden could be reduced by 11 280 km. Conclusion: Remote access for EAM was feasible and safe in this single-centre study. Procedural data were comparable to procedures with onsite support. In the future, this new solution might have a great impact on facilitating electrophysiological procedures.

9.
Europace ; 26(5)2024 May 02.
Article in English | MEDLINE | ID: mdl-38647070

ABSTRACT

AIMS: Simplified ablation technologies for pulmonary vein isolation (PVI) are increasingly performed worldwide. One of the most common complications following PVI are vascular access-related complications. Lately, venous closure systems (VCSs) were introduced into clinical practice, aiming to reduce the time of bed rest, to increase the patients' comfort, and to reduce vascular access-related complications. The aim of the present study is to compare the safety and efficacy of using a VCS to achieve haemostasis following single-shot PVI to the actual standard of care [figure-of-eight suture and manual compression (MC)]. METHODS AND RESULTS: This is a prospective, multicentre, randomized, controlled, open-label trial performed at three German centres. Patients were randomized 1:1 to undergo haemostasis either by means of VCS (VCS group) or of a figure-of-eight suture and MC (F8 group). The primary efficacy endpoint was the time to ambulation, while the primary safety endpoint was the incidence of major periprocedural adverse events until hospital discharge. A total of 125 patients were randomized. The baseline characteristics were similar between the groups. The VCS group showed a shorter time to ambulation [109.0 (82.0, 160.0) vs. 269.0 (243.8, 340.5) min; P < 0.001], shorter time to haemostasis [1 (1, 2) vs. 5 (2, 10) min; P < 0.001], and shorter time to discharge eligibility [270 (270, 270) vs. 340 (300, 458) min; P < 0.001]. No major vascular access-related complication was reported in either group. A trend towards a lower incidence of minor vascular access-related complications on the day of procedure was observed in the VCS group [7 (11.1%) vs. 15 (24.2%); P = 0.063] as compared to the control group. CONCLUSION: Following AF ablation, the use of a VCS results in a significantly shorter time to ambulation, time to haemostasis, and time to discharge eligibility. No major vascular access-related complications were identified. The use of MC and a figure-of-eight suture showed a trend towards a higher incidence of minor vascular access-related complications.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Suture Techniques , Humans , Atrial Fibrillation/surgery , Female , Male , Middle Aged , Catheter Ablation/adverse effects , Catheter Ablation/methods , Prospective Studies , Pulmonary Veins/surgery , Suture Techniques/adverse effects , Aged , Treatment Outcome , Germany , Time Factors , Vascular Closure Devices , Early Ambulation , Hemostatic Techniques/instrumentation
10.
Eur Heart J Case Rep ; 8(3): ytae113, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38487587

ABSTRACT

Background: Despite modern techniques for ablation of ventricular tachycardia (VT), the procedure faces challenges such as deep intramural substrates or inaccessibility of the pericardial space. We aim to present a case of successful surgical treatment of a patient with drug-refractory VT, an apical aneurysm, large left ventricular (LV) thrombus, and recurrent implantable cardioverter defibrillator (ICD) shocks following failed epicardial catheter ablation. Case summary: A 67-year-old male with a history of ischaemic cardiomyopathy was brought to the emergency room after a syncope because of VT. The VT was terminated by an external cardioversion prior to admission. The ICD interrogation showed an episode of sustained monomorphic VT with eight appropriate but mostly ineffective ICD shocks. An echocardiogram revealed an apical aneurysm with a thrombus. Anticoagulation and antiarrhythmic drug therapy were initiated. Days later, the patient suffered recurrent episodes of sustained VTs, refractory to pharmacological therapy, and epicardial ablation; therefore, following aneurysmectomy and thrombus removal, a reconstruction of the LV and surgical endocardial cryoablation were performed. In addition, ICD extraction was done due to recurrent bacteraemia with Staphylococcus aureus. A subcutaneous ICD was later implanted. After surgery, the patient remained free of any VT episodes during 44 months of follow-up. Conclusion: Combined surgical ventricular reconstruction and intraoperative cryoablation may be considered as an alternative, highly effective therapy in patients with drug-refractory VTs in the setting of a LV thrombus.

11.
JACC Clin Electrophysiol ; 10(5): 900-912, 2024 May.
Article in English | MEDLINE | ID: mdl-38430087

ABSTRACT

BACKGROUND: Pulmonary vein isolation (PVI) alone is insufficient to treat many patients with persistent atrial fibrillation (PersAF). Adjunctive left atrial posterior wall (LAPW) ablation with thermal technologies has revealed lack of efficacy, perhaps limited by the difficulty in achieving lesion durability amid concerns of esophageal injury. OBJECTIVES: This study aims to compare the safety and effectiveness of PVI + LAPW ablation vs PVI in patients with PersAF using pulsed-field ablation (PFA). METHODS: In a retrospective analysis of the MANIFEST-PF (Multi-National Survey on the Methods, Efficacy, and Safety on the Post-approval Clinical Use of Pulsed Field Ablation) registry, we studied consecutive PersAF patients undergoing post-approval treatment with a pentaspline PFA catheter. The primary effectiveness outcome was freedom from any atrial arrhythmia of ≥30 seconds. Safety outcomes included the composite of acute and chronic major adverse events. RESULTS: Of the 547 patients with PersAF who underwent PFA, 131 (24%) received adjunctive LAPW ablation. Compared to PVI-alone, patients receiving adjunctive LAPW ablation were younger (65 vs 67 years of age, P = 0.08), had a lower CHA2DS2-VASc score (2.3 ± 1.6 vs 2.6 ± 1.6, P = 0.08), and were more likely to receive electroanatomical mapping (48.1% vs 39.0%, P = 0.07) and intracardiac echocardiography imaging (46.1% vs 17.1%, P < 0.001). The 1-year Kaplan-Meier estimate for freedom from atrial arrhythmias was not statistically different between groups in the full (PVI + LAPW: 66.4%; 95% CI: 57.6%-74.4% vs PVI: 73.1%; 95% CI: 68.5%-77.2%; P = 0.68) and propensity-matched cohorts (PVI + LAPW: 71.7% vs PVI: 68.5%; P = 0.34). There was also no significant difference in major adverse events between the groups (2.2% vs 1.4%, respectively, P = 0.51). CONCLUSIONS: In patients with PersAF undergoing PFA, as compared to PVI-alone, adjunctive LAPW ablation did not improve freedom from atrial arrhythmia at 12 months.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Heart Atria , Pulmonary Veins , Humans , Atrial Fibrillation/surgery , Male , Female , Aged , Catheter Ablation/methods , Catheter Ablation/adverse effects , Middle Aged , Retrospective Studies , Heart Atria/surgery , Pulmonary Veins/surgery , Treatment Outcome , Registries
12.
Int J Cardiol Heart Vasc ; 50: 101325, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38419611

ABSTRACT

Background: Very high-power short-duration (vHP-SD) radiofrequency (RF) ablation of atrial fibrillation (AF) treatment by pulmonary vein isolation (PVI) aims for safer, more effective and faster procedures. Although acute efficacy and safety for PVI was recently shown data on chronic PVI durability is limited. Here chronic PVI durability was evaluated during repeat electrophysiological procedures in patients after initial vHP-SD and conventional RF based PVI. Methods: A total of 25 consecutive patients with repeat left atrial procedures after initial vHP-SD based PVI were included in this study. Twenty-five patients with previous conventional RF based PVI and repeat left atrial procedures served as control (control group). Results: For index procedures the median RF time was 328 (277, 392) seconds (vHP-SD) and 1470 (1310, 1742) seconds (control); p < 0.001, the median procedure time was 55 (53, 68) minutes (vHP-SD) and 110 (94, 119) (control); p < 0.001). First pass isolation rate was 84 % (vHP-SD) and 88 % (control, p = 0.888). No differences for severe adverse events (vHP-SD: 1/25, 4 % vs. control: 0/25, 0 %; p = 0.676 were detected.Chronic durability of all PVs was assessed in vHP-SD: 16/25 (64 %) and control: 8/25 (32 %) patients (p = 0.023) and vHP-SD: 81 % and control: 62 % of PVs were found to be isolated (p = 0.003). For right PVs vHP-SD: 84 % vs. control: 60 % of PVs (p < 0.001) and for left PVs vHP-SD: 78 % vs. control: 64 % (p = 0.123) were found to be isolated. Conclusions: PVI solely utilizing vHP-SD via a very close-protocol provides fast, safe and effective acute PVI. High rates of chronically isolated pulmonary veins have been detected.

13.
Herzschrittmacherther Elektrophysiol ; 35(Suppl 1): 102-109, 2024 Mar.
Article in German | MEDLINE | ID: mdl-38407580

ABSTRACT

This article focuses on ventricular arrythmias without evidence for structural heart disease. There are many different reasons for this type of arrythmia and there is still a gap of knowledge. Starting with the first description of this disease, we present the diagnosis and management with medication, and finally catheter ablation procedures from the beginning to how it is currently treated and how it possibly will be treated in the near future.


Subject(s)
Catheter Ablation , Heart Diseases , Tachycardia, Ventricular , Humans , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/surgery , Arrhythmias, Cardiac/surgery
14.
J Cardiovasc Electrophysiol ; 35(1): 78-85, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37942843

ABSTRACT

INTRODUCTION: Atrio-esophageal fistula after esophageal thermal injury (ETI) is one of the most devastating complications of available energy sources for atrial fibrillation (AF) ablation. Pulsed field ablation (PFA) uses electroporation as a new energy source for catheter ablation with promising periprocedural safety advantages over existing methods due to its unique myocardial tissue sensitivity. In preclinical animal studies, a dose-dependent esophageal temperature rise has been reported. In the TESO-PFA registry intraluminal esophageal temperature (TESO) changes in a clinical setting are evaluated. METHODS: Consecutive symptomatic AF patients (62 years, 67% male, 61% paroxysmal AF, CHA2 DS2 Vasc Score 2) underwent first-time PFA and were prospectively enrolled into our registry. Eight pulse trains (2 kV/2.5 s, bipolar, biphasic, x4 basket/flower configuration each) were delivered to each pulmonary vein (PV). Two extra pulse trains per PV in flower configuration were added for wide antral circumferential ablation. Continuous intraluminal esophageal temperature (TESO) was monitored with a 12-pole temperature probe. RESULTS: Median TESO change was statistically significant and increased by 0.8 ± 0.6°C, p < .001. A TESO increase ≥ 1°C was observed in 10/43 (23%) patients. The highest TESO measured was 40.3°C. The largest TESO difference (∆TESO) was 3.7°C. All patients remained asymptomatic considering possible ETI. No atrio-esophageal fistula was reported on follow-up. CONCLUSION: A small but significant intraluminal esophageal temperature rise can be observed in most patients during PFA. TESO rise over 40°C is rare. The clinical implications of the observed findings need to be further evaluated.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Esophageal Fistula , Pulmonary Veins , Animals , Humans , Male , Female , Temperature , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Heart Rate , Esophageal Fistula/diagnosis , Esophageal Fistula/etiology , Catheter Ablation/adverse effects , Catheter Ablation/methods , Pulmonary Veins/surgery , Treatment Outcome
16.
J Cardiovasc Electrophysiol ; 35(3): 547-556, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37855621

ABSTRACT

The QDOT MICRO™ Catheter is a novel open-irrigated contact force-sensing radiofrequency ablation catheter. It offers very high-power short-duration (vHPSD) ablation with 90 W for 4 s to improve safety and efficacy of catheter ablation procedures. Although the QDOT MICRO™ Catheter was mainly designed for pulmonary vein isolation (PVI) its versatility to treat atrial fibrillation (AF) and other types of arrhythmias was recently evaluated by the FAST and FURIOUS study series and other studies and will be presented in this article. Available study and registry data as well as case reports concerning utilization of the QDOT MICRO™ Catheter for the treatment of cardiac arrhythmias including AF, focal and macroreentry atrial tachycardia, typical atrial flutter by cavotricuspid isthmus block, premature ventricular contractions, and accessory pathways were reviewed and summarized. In summary, the QDOT MICRO™ Catheter showed safety and efficacy for PVI and is able to treat also other types of arrhythmias as is was recently evaluated by case reports and the FAST and FURIOUS studies.


Subject(s)
Atrial Fibrillation , Atrial Flutter , Catheter Ablation , Pulmonary Veins , Tachycardia, Supraventricular , Humans , Treatment Outcome , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Atrial Flutter/diagnosis , Atrial Flutter/surgery , Catheter Ablation/adverse effects , Catheter Ablation/methods , Pulmonary Veins/surgery
17.
JAMA Cardiol ; 8(12): 1142-1151, 2023 12 01.
Article in English | MEDLINE | ID: mdl-37910101

ABSTRACT

Importance: Previous studies evaluating the association of patient sex with clinical outcomes using conventional thermal ablative modalities for atrial fibrillation (AF) such as radiofrequency or cryoablation are controversial due to mixed results. Pulsed field ablation (PFA) is a novel AF ablation energy modality that has demonstrated preferential myocardial tissue ablation with a unique safety profile. Objective: To compare sex differences in patients undergoing PFA for AF in the Multinational Survey on the Methods, Efficacy, and Safety on the Postapproval Clinical Use of Pulsed Field Ablation (MANIFEST-PF) registry. Design, Setting, and Participants: This was a retrospective cohort study of MANIFEST-PF registry data, which included consecutive patients undergoing postregulatory approval treatment with PFA to treat AF between March 2021 and May 2022 with a median follow-up of 1 year. MANIFEST-PF is a multinational, retrospectively analyzed, prospectively enrolled patient-level registry including 24 European centers. The study included all consecutive registry patients (age ≥18 years) who underwent first-ever PFA for paroxysmal or persistent AF. Exposure: PFA was performed on patients with AF. All patients underwent pulmonary vein isolation and additional ablation, which was performed at the discretion of the operator. Main Outcomes and Measures: The primary effectiveness outcome was freedom from clinically documented atrial arrhythmia for 30 seconds or longer after a 3-month blanking period. The primary safety outcome was the composite of acute (<7 days postprocedure) and chronic (>7 days) major adverse events (MAEs). Results: Of 1568 patients (mean [SD] age, 64.5 [11.5] years; 1015 male [64.7%]) with AF who underwent PFA, female patients, as compared with male patients, were older (mean [SD] age, 68 [10] years vs 62 [12] years; P < .001), had more paroxysmal AF (70.2% [388 of 553] vs 62.4% [633 of 1015]; P = .002) but had fewer comorbidities such as coronary disease (9% [38 of 553] vs 15.9% [129 of 1015]; P < .001), heart failure (10.5% [58 of 553] vs 16.6% [168 of 1015]; P = .001), and sleep apnea (4.7% [18 of 553] vs 11.7% [84 of 1015]; P < .001). Pulmonary vein isolation was performed in 99.8% of female (552 of 553) and 98.9% of male (1004 of 1015; P = .90) patients. Additional ablation was performed in 22.4% of female (124 of 553) and 23.1% of male (235 of 1015; P = .79) patients. The 1-year Kaplan-Meier estimate for freedom from atrial arrhythmia was similar in male and female patients (79.0%; 95% CI, 76.3%-81.5% vs 76.3%; 95% CI, 72.5%-79.8%; P = .28). There was also no significant difference in acute major AEs between groups (male, 1.5% [16 of 1015] vs female, 2.5% [14 of 553]; P = .19). Conclusion and Relevance: Results of this cohort study suggest that after PFA for AF, there were no significant sex differences in clinical effectiveness or safety events.


Subject(s)
Atrial Fibrillation , Humans , Male , Female , Middle Aged , Aged , Adolescent , Atrial Fibrillation/drug therapy , Retrospective Studies , Cohort Studies , Sex Factors , Treatment Outcome
19.
Circ J ; 87(12): 1722-1726, 2023 11 24.
Article in English | MEDLINE | ID: mdl-37532529

ABSTRACT

BACKGROUND: Pulsed field ablation (PFA) is a non-thermal energy source with promising safety and efficacy advantages. We aimed to develop a convenient, safe, effective and fast method of pulmonary vein isolation (PVI) utilizing a penta-spline PFA catheter via a single femoral vein and a venous closure system.Methods and Results: Consecutive patients (n=50; mean age: 63.6±10.7 years, 38% female) presenting with AF (paroxysmal AF: 56%) underwent first-time PVI via PFA. A single ultrasound-guided femoral vein puncture and a single transseptal puncture were used. After PVI using the penta-spline PFA catheter, extra pulse trains were added to the posterior wall for wide antral circumferential ablation. A venous closure system was used and a Donati suture was performed. The pressure bandage was removed after 1 h. A total of 196 PVs were identified and isolated with PFA only. The mean procedural time was 27.4±6.6 min, and the mean dwelling time was 14.4±5.5 min. Time to ambulation was 3.3±3.1 h. No severe complications occurred. During a mean follow-up of 6.5±2.1 months, 41/50 patients (82%) remained in sinus rhythm. CONCLUSIONS: The combination of a single venous puncture, single transseptal puncture approach using PFA and vascular closure device resulted in a 100% rate of acute PVI and an extraordinarily fast procedure and time to ambulation. The rate of periprocedural complications was low.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Female , Middle Aged , Aged , Male , Pulmonary Veins/surgery , Treatment Outcome , Catheter Ablation/methods , Atrial Fibrillation/surgery , Catheters
20.
Europace ; 25(9)2023 08 02.
Article in English | MEDLINE | ID: mdl-37589146

ABSTRACT

AIMS: Catheter ablation with a cryoballoon (CB) provides effective and durable pulmonary vein (PV) isolation (PVI) associated with encouraging clinical outcome data. The novel POLARx CB incorporates unique features, which may translate into improved safety, efficacy, and outcomes. The ICE-AGE-1 study aimed to assess the efficacy, safety, and 1-year clinical follow-up of the POLARx CB in comparison to the Arctic Front Advance Pro CB (AF-CB4). METHODS AND RESULTS: A total of 103 consecutive patients with paroxysmal or persistent atrial fibrillation (AF) who underwent POLARx-based PVI (POLARx group) were prospectively enrolled and were compared to 102 consecutive patients previously treated with the AF-CB4 (AF-CB4 group). The mean age was 68.7 ± 10.2 (POLARx) and 65.7 ± 12 (AF-CB4, P = 0.0551) years. A total of 412 (POLARx) and 404 (AF-CB4) PVs were identified. All PVs, except for one PV in the POLARx group, were successfully isolated. A significant difference regarding the mean minimal CB temperature reached using the POLARx CB (-56.1 ± 8.3°C) and AF-CB4 (-46.9 ± 10.1°C) was observed (P < 0.0001). Real-time PVI was visualized in 71% of PVs in the POLARx group and 46% of them in the AF-CB4 group (P < 0.001). The mean procedure time was comparable: 54.5 ± 17.1 min for POLARx and 59.4 ± 18.6 min for AF-CB4 (P = 0.0509). No differences were observed in terms of periprocedural complications. There were comparable rates in freedom of AF or atrial tachycardia recurrence after 12 months, beyond a 90-day long blanking period: 78.9% in the POLARx group vs. 77.2% in the AF-CB4 group (P = 0.804). CONCLUSION: The novel POLARx CB showed similar safety, efficacy, and 1-year recurrence-free survival rates compared to the AF-CB4. A higher rate of real-time electrical PV recordings and significantly lower balloon temperatures were observed using the POLARx as compared to AF-CB4.


Subject(s)
Catheter Ablation , Pulmonary Veins , Humans , Middle Aged , Aged , Infant , Pulmonary Veins/surgery , Prospective Studies , Catheter Ablation/adverse effects , Temperature
SELECTION OF CITATIONS