1.
Intensive Care Med Exp ; 12(1): 21, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38424411

ABSTRACT

BACKGROUND: Obtaining a properly fitting non-invasive ventilation (NIV) mask to treat acute respiratory failure is a major challenge, especially in young children and patients with craniofacial abnormalities. Personalization of NIV masks holds promise to improve pediatric NIV efficiency. As current customization methods are relatively time consuming, this study aimed to test the air leak and surface pressure performance of personalized oronasal face masks using 3D printed soft materials. Personalized masks of three different biocompatible materials (silicone and photopolymer resin) were developed and tested on three head models of young children with abnormal facial features during preclinical bench simulation of pediatric NIV. Air leak percentages and facial surface pressures were measured and compared for each mask. RESULTS: Personalized NIV masks could be successfully produced in under 12 h in a semi-automated 3D production process. During NIV simulation, overall air leak performance and applied surface pressures were acceptable, with leak percentages under 30% and average surface pressure values mostly remaining under normal capillary pressure. There was a small advantage of the masks produced with soft photopolymer resin material. CONCLUSION: This first, proof-of-concept bench study simulating NIV in children with abnormal facial features, showed that it is possible to obtain biocompatible, personalized oronasal masks with acceptable air leak and facial surface pressure performance using a relatively short, and semi-automated production process. Further research into the clinical value and possibilities for application of personalized NIV masks in critically ill children is needed.

2.
Intensive Care Med Exp ; 11(1): 25, 2023 May 01.
Article in English | MEDLINE | ID: mdl-37121963

ABSTRACT

BACKGROUND: Perioperative acute kidney injury (AKI) caused by ischemia-reperfusion (IR) is a significant contributor to mortality and morbidity after major surgery. Furosemide is commonly used in postoperative patients to promote diuresis and reduce tissue edema. However, the effects of furosemide on renal microcirculation, oxygenation and function are poorly understood during perioperative period following ischemic insult. Herein, we investigated the effects of furosemide in rats subjected IR insult. METHODS: 24 Wistar albino rats were divided into 4 groups, with 6 in each; Sham-operated Control (C), Control + Furosemide (C + F), ischemia/reperfusion (IR), and IR + F. After induction of anesthesia (BL), supra-aortic occlusion was applied to IR and IR + F groups for 45 min followed by ongoing reperfusion for 15 min (T1) and 2 h (T2). Furosemide infusion was initiated simultaneously in the intervention groups after ischemia. Renal blood flow (RBF), vascular resistance (RVR), oxygen delivery (DO2ren) and consumption (VO2ren), sodium reabsorption (TNa+), oxygen utilization efficiency (VO2/TNa+), cortical (CµO2) and medullary (MµO2) microvascular oxygen pressures, urine output (UO) and creatinine clearance (Ccr) were measured. Biomarkers of inflammation, oxidative and nitrosative stress were measured and kidneys were harvested for histological analysis. RESULTS: IR significantly decreased RBF, mainly by increasing RVR, which was exacerbated in the IR + F group at T2 (2198 ± 879 vs 4233 ± 2636 dyne/s/cm5, p = 0.07). CµO2 (61.6 ± 6.8 vs 86 ± 6.6 mmHg) and MµO2 (51.1 ± 4.1 vs 68.7 ± 4.9 mmHg, p < 0.05) were both reduced after IR and did not improve by furosemide. Moreover, VO2/TNa+ increased in the IR + F group at T2 with respect to the IR group (IR: 3.3 ± 2 vs IR + F: 8.2 ± 10 p = 0.07) suggesting a possible deterioration of oxygen utilization. Ccr did not change, but plasma creatinine increased significantly in IR + F groups. Histopathology revealed widespread damage both in the cortex and medulla in IR, IR + F and C + F groups. CONCLUSION: Renal microvascular oxygenation, renal function, renal vascular resistance, oxygen utilization and damage were not improved by furosemide administration after IR insult. Our study suggests that furosemide may cause additional structural and functional impairment to the kidney following ischemic injury and should be used with caution.

3.
Am J Physiol Renal Physiol ; 318(5): F1271-F1283, 2020 05 01.
Article in English | MEDLINE | ID: mdl-32281418

ABSTRACT

PEGylated carboxyhemoglobin (PEGHbCO), which has carbon monoxide-releasing properties and plasma expansion and oxygen-carrying properties, may improve both skeletal microcirculatory flow and renal cortical microcirculatory Po2 (CµPo2) and, subsequently, limit endotoxemia-induced acute kidney injury. Anesthetized, ventilated Wistar albino rats (n = 44) underwent endotoxemic shock. CµPo2 was measured in exposed kidneys using a phosphorescence-quenching method. Rats were randomly assigned to the following five groups: 1) unresuscitated lipopolysaccharide (LPS), 2) LPS + Ringer's acetate (RA), 3) LPS + RA + 0.5 µg·kg·-1min-1 norepinephrine (NE), 4) LPS + RA + 320 mg/kg PEGHbCO, and 5) LPS + RA + PEGHbCO + NE. The total volume was 30 mL/kg in each group. A time control animal group was used. Skeletal muscle microcirculation was assessed by handheld intravital microscopy. Kidney immunohistochemistry and myeloperoxidase-stained leukocytes in glomerular and peritubular areas were analyzed. Endotoxemia-induced histological damage was assessed. Plasma levels of IL-6, heme oxygenase-1, malondialdehyde, and syndecan-1 were assessed by ELISA. CµPo2 was higher in the LPS + RA + PEGHbCO-resuscitated group, at 35 ± 6mmHg compared with 21 ± 12 mmHg for the LPS+RA group [mean difference: -13.53, 95% confidence interval: (-26.35; -0.7156), P = 0.035]. The number of nonflowing, intermittent, or sluggish capillaries was smaller in groups infused with PEGHbCO compared with RA alone (P < 0.05), while the number of normally perfused vessels was greater (P < 0.05). The addition of NE did not further improve CµPo2 or microcirculatory parameters. Endotoxemia-induced kidney immunohistochemistry and histological alterations were not mitigated by PEGHbCO 1 h after resuscitation. Renal leukocyte infiltration and plasma levels of biomarkers were similar across groups. PEGHbCO enhanced CµPo2 while restoring skeletal muscle microcirculatory flow in previously nonflowing capillaries. PEGHbCO should be further evaluated as a resuscitation fluid in mid- to long-term models of sepsis-induced acute kidney injury.


Subject(s)
Acute Kidney Injury/prevention & control , Blood Substitutes/administration & dosage , Carboxyhemoglobin/administration & dosage , Endotoxemia/therapy , Fluid Therapy , Kidney Cortex/blood supply , Microcirculation/drug effects , Muscle, Skeletal/blood supply , Oxygen Consumption/drug effects , Polyethylene Glycols/administration & dosage , Renal Circulation/drug effects , Resuscitation , Acute Kidney Injury/blood , Acute Kidney Injury/etiology , Acute Kidney Injury/physiopathology , Animals , Biomarkers/blood , Disease Models, Animal , Endotoxemia/blood , Endotoxemia/chemically induced , Endotoxemia/physiopathology , Kidney Cortex/metabolism , Lipopolysaccharides , Male , Rats, Wistar , Time Factors
4.
J Appl Physiol (1985) ; 122(2): 307-316, 2017 Feb 01.
Article in English | MEDLINE | ID: mdl-27932672

ABSTRACT

Quantitative measurements of microcirculatory and tissue oxygenation are of prime importance in experimental research. The noninvasive phosphorescence quenching method has given further insight into the fundamental mechanisms of oxygen transport to healthy tissues and in models of disease. Phosphorimeters are devices dedicated to the study of phosphorescence quenching. The experimental applications of phosphorimeters range from measuring a specific oxygen partial pressure (Po2) in cellular organelles such as mitochondria, finding values of Po2 distributed over an organ or capillaries, to measuring microcirculatory Po2 changes simultaneously in several organ systems. Most of the current phosphorimeters use flash lamps as a light excitation source. However, a major drawback of flash lamps is their inherent plasma glow that persists for tens of microseconds after the primary discharge. This complex distributed excitation pattern generated by the flash lamp can lead to inaccurate Po2 readings unless a deconvolution analysis is performed. Using light-emitting diode (LED), a rectangular shaped light pulse can be generated that provides a more uniformly distributed excitation signal. This study presents the design and calibration process of an LED-based phosphorimeter (LED-P). The in vitro calibration of the LED-P using palladium(II)-meso-tetra(4-carboxyphenyl)-porphyrin (Pd-TCCP) as a phosphorescent dye is presented. The pH and temperature were altered to assess whether the decay times of the Pd-TCCP measured by the LED-P were significantly influenced. An in vivo validation experiment was undertaken to measure renal cortical Po2 in a rat subjected to hypoxic ventilation conditions and ischemia/reperfusion. The benefits of using LEDs as a light excitation source are presented.


Subject(s)
Microcirculation/physiology , Oxygen/metabolism , Animals , Calibration , Capillaries/metabolism , Capillaries/physiology , Hydrogen-Ion Concentration , Light , Luminescent Measurements/methods , Male , Partial Pressure , Rats , Rats, Sprague-Dawley , Temperature
5.
Eur J Nucl Med Mol Imaging ; 31(2): 222-8, 2004 Feb.
Article in English | MEDLINE | ID: mdl-15129704

ABSTRACT

A realistic 3-D gated cardiac phantom with known left ventricular (LV) volumes and ejection fractions (EFs) was produced to evaluate quantitative measurements obtained from gated myocardial single-photon emission tomography (SPET). The 3-D gated cardiac phantom was designed and constructed to fit into the Data Spectrum anthropomorphic torso phantom. Flexible silicone membranes form the inner and outer walls of the simulated left ventricle. Simulated LV volumes can be varied within the range 45-200 ml. The LV volume curve has a smooth and realistic clinical shape that is produced by a specially shaped cam connected to a piston. A fixed 70-ml stroke volume is applied for EF measurements. An ECG signal is produced at maximum LV filling by a controller unit connected to the pump. This gated cardiac phantom will be referred to as the Amsterdam 3-D gated cardiac phantom, or, in short, the AGATE cardiac phantom. SPET data were acquired with a triple-head SPET system. Data were reconstructed using filtered back-projection following pre-filtering and further processed with the Quantitative Gated SPECT (QGS) software to determine LV volume and EF values. Ungated studies were performed to measure LV volumes ranging from 45 ml to 200 ml. The QGS-determined LV volumes were systematically underestimated. For different LV combinations, the stroke volumes measured were consistent at 60-61 ml for 8-frame studies and 63-65 ml for 16-frame studies. QGS-determined EF values were slightly overestimated between 1.25% EF units for 8-frame studies and 3.25% EF units for 16-frame studies. In conclusion, the AGATE cardiac phantom offers possibilities for quality control, testing and validation of the whole gated cardiac SPET sequence, and testing of different acquisition and processing parameters and software.


Subject(s)
Equipment Failure Analysis , Gated Blood-Pool Imaging/instrumentation , Heart/diagnostic imaging , Imaging, Three-Dimensional/instrumentation , Phantoms, Imaging , Tomography, Emission-Computed, Single-Photon/instrumentation , Equipment Design , Gated Blood-Pool Imaging/methods , Gated Blood-Pool Imaging/standards , Heart Ventricles/diagnostic imaging , Humans , Netherlands , Reproducibility of Results , Sensitivity and Specificity , Stroke Volume , Tomography, Emission-Computed, Single-Photon/methods , Tomography, Emission-Computed, Single-Photon/standards