Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J Med Case Rep ; 15(1): 67, 2021 Feb 09.
Article in English | MEDLINE | ID: mdl-33557885

ABSTRACT

BACKGROUND: Rehabilitation of the entire dentition with amelogenesis imperfecta (AI) tends to pose a great challenge to the clinician. Most of the cases of amelogenesis imperfecta are reported to be associated with skeletal and dental deformities which results in severe sensitivity of the dental tissues. CASE PRESENTATION: This clinical case report marks out the total restoration of the oral condition of a young Indian patient diagnosed with the hypoplastic type of amelogenesis imperfecta. Fixed metal ceramic prosthesis were planned to strengthen the masticatory activity, aesthetics, to banish the dental sensitivity and to build up the general persona of the patient. The patient was followed-up at 6 months, 1 year and 2 years intervals. Functional and esthetic impairment was not visible after the follow up period and the treatment outcome was successful. The entire treatment plan was intended to enhance the functional, esthetic and the masticatory component of the occlusal architecture. CONCLUSION: This case report details the presentation, characteristic radiographic findings, and management of a patient with an extremely rare condition of amelogenesis imperfecta.


Subject(s)
Amelogenesis Imperfecta , Amelogenesis Imperfecta/diagnostic imaging , Amelogenesis Imperfecta/therapy , Esthetics, Dental , Humans , Patient Care Planning , Treatment Outcome
2.
Indian J Dent Res ; 31(2): 282-290, 2020.
Article in English | MEDLINE | ID: mdl-32436910

ABSTRACT

OBJECTIVE: This study evaluated the effect of chemical disinfection and microwave irradiation on the surface hardness and roughness of two commercially available hard relining materials (Ufi Gel hard, GC Kooliner) and one denture base resin (Trevalon). MATERIALS AND METHODS: A total of 72 specimens (n = 24) were divided into four groups. C: Not disinfected, Cl: disinfected with 4% chlorhexidine solution, Gl: disinfected with 2% glutaraldehyde solution, Mw: disinfected with microwave irradiation (650 W; 6 min). Hardness and roughness measurements were made after polymerisation, 1st day, 14th day and 28th day. RESULTS: Ufi Gel hard showed an increased roughness after 1st day (P = 0.021) following chemical disinfection and GC Kooliner showed similar results after 14th day (P < 0.05). Microwave irradiation showed a significant increase in surface roughness value after 1st day (P < 0.05) for both Ufi Gel hard and GC Kooliner. Hardness of both Ufi Gel (12.131 to 7.333 VHN) and Kooliner (9.133 to 5.276 VHN) was significantly reduced by chemical disinfection, while microwave irradiation resulted in an increased surface hardness of Kooliner (from 9.126 to 12.713 VHN) and Ufi Gel hard (from 11.698 to 14.940VHN). Results for Trevalon were not significant for both the disinfection methods. CONCLUSIONS: Microwave irradiation increased the surface roughness and hardness of Ufi Gel hard and Kooliner, while chemical disinfection resulted in a decreased hardness and increased roughness of both hard relining materials. There was no effect of either of the disinfection methods on Trevalon.


Subject(s)
Denture Bases , Denture Liners , Disinfection , Hardness , Materials Testing , Microwaves , Surface Properties
3.
J Prosthodont ; 28(2): e795-e805, 2019 Feb.
Article in English | MEDLINE | ID: mdl-30191668

ABSTRACT

PURPOSE: To analyze and compare the stress distribution in an implant-retained overdenture complex using ball and Locator attachments of three heights by means of a 3D finite element analysis (FEA). MATERIALS AND METHODS: Six finite element models comprising an edentulous mandible with two interforaminal bone-level implants and ball attachments of heights 1 mm (A1), 3 mm (A3), and 5 mm (A5), and Locator attachments of heights 1 mm (B1), 3 mm (B3), and 5 mm (B5), were designed using ANSYS Workbench Software. Unilateral vertical (100 N) and oblique loads (100 N at 30° to the longitudinal axis of the implant in buccolingual direction) were applied. Average von Mises stress values were evaluated quantitatively and qualitatively. RESULTS: Locator attachments showed lower stress values as compared to the ball attachments in all examined areas. The increase in the height of both resulted in increased stress values. Higher values were observed at the implant neck in all models, as compared to the body and the apex. The recorded stress was higher in the cortical bone as compared to the cancellous bone. CONCLUSIONS: Within the limitations of the study, Locator attachments demonstrated lesser and more homogenous stress distribution in the implant-overdenture complex in comparison to ball attachments. The stresses generated within the tissues increase with an increase in collar height of the attachment system and therefore, attachments should be as short as possible for more favorable stress transmission.


Subject(s)
Dental Implant-Abutment Design/methods , Dental Prosthesis, Implant-Supported/methods , Denture, Overlay , Cone-Beam Computed Tomography , Dental Abutments , Dental Stress Analysis , Finite Element Analysis , Humans , Mandible , Models, Dental , Radiography, Dental
SELECTION OF CITATIONS
SEARCH DETAIL
...