Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Chemosphere ; 121: 47-53, 2015 Feb.
Article in English | MEDLINE | ID: mdl-25434271

ABSTRACT

This work investigated the capability of using a boron-doped diamond (BDD) electrode for bacterial disinfection in different water matrices containing varying amounts of chloride. The feed water containing Pseudomonas aeruginosa was electrochemically treated while applying different electrode conditions. Depending on the applied current density and the exposure time, inactivation between 4- and 8-log of the targeted microorganisms could be achieved. The disinfection efficiency was driven by the generation of free chlorine as a function of chloride concentration in the water. A synergetic effect of generating both free chlorine and ozone in situ during the disinfection process resulted in an effective bactericidal impact. The formation of the undesired by-products chlorate and perchlorate depended on the water matrix, the applied current density and the desired target disinfection level. In case of synthetic water with a low chloride concentration (20 mg L(-1)) and an applied current density of 167 mA cm(-2), a 6-log inactivation of Pseudomonas aeruginosa could be achieved after 5 min of exposure. The overall energy consumption ranged between 0.3 and 0.6 kW h m(-3) depending on the applied current density and water chemistry. Electrochemical water disinfection represents a suitable and efficient process for producing pathogen-free water without the use of any chemicals.


Subject(s)
Boron/chemistry , Chlorine/chemistry , Diamond/chemistry , Disinfection/methods , Ozone/chemistry , Water Microbiology , Water Purification/methods , Disinfection/instrumentation , Electrochemical Techniques , Electrodes , Equipment Design , Kinetics , Pseudomonas aeruginosa/drug effects , Pseudomonas aeruginosa/growth & development , Water Microbiology/standards , Water Purification/instrumentation
2.
J Sep Sci ; 36(18): 3011-8, 2013 Sep.
Article in English | MEDLINE | ID: mdl-23857646

ABSTRACT

The presence of pollutants and their transformation products (TPs) in the water system is a big concern because of possible adverse effects on the aquatic environment. Their identification is still a challenge that requires the combination of different chromatographic techniques. In the current research, serial coupling of RPLC and zwitterionic hydrophilic interaction LC with TOF-MS was investigated as a single separation technique for the screening of suspected TPs from electrochemical oxidation of diclofenac using a boron-doped diamond electrode. Diclofenac oxidation was performed in three water matrices in order to study its transformation in different chemical contexts. 47 TPs resulting from similar oxidation methods were selected from the literature. As in most cases standards were not available, an identification procedure based on accurate mass data and chromatographic behavior was proposed. According to this procedure, 11 suspected TPs, previously analyzed by LC, GC, or ion chromatography, were detected in a single injection. The method was proved to be reliable and versatile and it could be efficiently employed as a comprehensive analytical tool for the simultaneous analysis of compounds in a wide polarity range.


Subject(s)
Boron/chemistry , Diamond/chemistry , Diclofenac/isolation & purification , Chromatography, High Pressure Liquid , Diclofenac/chemistry , Electrodes , Hydrophobic and Hydrophilic Interactions , Mass Spectrometry , Oxidation-Reduction
3.
BMC Med Genomics ; 4: 24, 2011 Mar 25.
Article in English | MEDLINE | ID: mdl-21439033

ABSTRACT

BACKGROUND: Proteomic technologies applied for profiling human biofluids and blood cells are considered to reveal new biomarkers of exposure or provide insights into novel mechanisms of adaptation. METHODS: Both a non-targeted (classical 2D-electrophoresis combined with mass spectrometry) as well as a targeted proteomic approach (multiplex immunoassay) were applied to investigate how fasting for 36 h, as compared to 12 h, affects the proteome of platelets, peripheral blood mononuclear cells (PBMC), plasma, urine and saliva collected from ten healthy volunteers. RESULTS: Between-subject variability was highest in the plasma proteome and lowest in the PBMC proteome. Random Forests analysis performed on the entire dataset revealed that changes in the level of the RhoGDI2 protein in PBMC and plasma ApoA4 levels were the two most obvious biomarkers of an extended fasting. Random Forests (RF) analysis of the multiplex immunoassay data revealed leptin and MMP-3 as biomarkers for extended fasting. However, high between-subject variability may have masked the extended fasting effects in the proteome of the biofluids and blood cells. CONCLUSIONS: Identification of significantly changed proteins in biofluids and blood cells using a non-targeted approach, together with the outcome of targeted analysis revealed both known and novel markers for a 36 h fasting period, including the cellular proteins RhoGDI2 and CLIC1, and plasma proteins ApoA4, leptin and MMP-3. The PBMC proteome exhibited the lowest between-subject variability and therefore these cells appear to represent the best biosamples for biomarker discovery in human nutrigenomics.


Subject(s)
Blood Cells/metabolism , Body Fluids/metabolism , Fasting , Proteome/metabolism , Proteomics/methods , Apolipoproteins A/blood , Biomarkers/metabolism , Cluster Analysis , Electrophoresis, Gel, Two-Dimensional , Guanine Nucleotide Dissociation Inhibitors/metabolism , Humans , Immunoassay , Leptin/metabolism , Mass Spectrometry , Matrix Metalloproteinase 3/metabolism , Principal Component Analysis , Time Factors , Tumor Suppressor Proteins/metabolism , rho Guanine Nucleotide Dissociation Inhibitor beta , rho-Specific Guanine Nucleotide Dissociation Inhibitors
4.
Genes Nutr ; 4(2): 95-102, 2009 Jun.
Article in English | MEDLINE | ID: mdl-19408033

ABSTRACT

Blood cells and biofluid proteomics are emerging as a valuable tool to assess effects of interventions on health and disease. This study is aimed to assess the amount and variability of proteins from platelets, peripheral blood mononuclear cells (PBMC), plasma, urine and saliva from ten healthy volunteers for proteomics analysis, and whether protein yield is affected by prolonged fasting. Volunteers provided blood, saliva and morning urine samples once a week for 4 weeks after an overnight fast. Volunteers were fasted for a further 24 h after the fourth sampling before providing their final samples. Each 10 mL whole blood provided 400-1,500 mug protein from platelets, and 100-600 mug from PBMC. 30 muL plasma depleted of albumin and IgG provided 350-650 mug protein. A sample of morning urine provided 0.9-8.6 mg protein/dL, and a sample of saliva provided 70-950 mug protein/mL. None of these yields were influenced by the degree of fasting (overnight or 36 h). In conclusion, in contrast to the yields from plasma, platelets and PBMC, the protein yields of urine and saliva samples were highly variable within and between subjects. Certain disease conditions may cause higher or lower PBMC counts and thus protein yields, or increased urinary protein levels.

6.
J Proteome Res ; 7(6): 2280-90, 2008 Jun.
Article in English | MEDLINE | ID: mdl-18489134

ABSTRACT

This study was designed to develop, optimize and validate protocols for blood processing prior to proteomic analysis of plasma, platelets and peripheral blood mononuclear cells (PBMC) and to determine analytical variation of a single sample of depleted plasma, platelet and PBMC proteins within and between four laboratories each using their own standard operating protocols for 2D gel electrophoresis. Plasma depleted either using the Beckman Coulter IgY-12 proteome partitioning kit or the Amersham albumin and IgG depletion columns gave good quality gels, but reproducibility appeared better with the single-use immuno-affinity column. The use of the Millipore Filter Device for protein concentration gave a 16% ( p < 0.005) higher recovery of protein in flow-through sample compared with acetone precipitation. The use of OptiPrep gave the lowest level of platelet contamination (1:0.8) during the isolation of PBMC from blood. Several proteins (among which are alpha-tropomyosin, fibrinogen and coagulation factor XIII A) were identified that may be used as biomarkers of platelet contamination in future studies. When identifying preselected spots, at least three out of the four centers found similar identities for 10 out of the 10 plasma proteins, 8 out of the 10 platelet proteins and 8 out of the 10 PBMC proteins. The discrepancy in spot identifications has been described before and may be explained by the mis-selection of spots due to laboratory-to-laboratory variation in gel formats, low scores on the peptide analysis leading to no or only tentative identifications, or incomplete resolution of different proteins in what appears as a single abundant spot. The average within-laboratory coefficient of variation (CV) for each of the matched spots after automatic matching using either PDQuest or ProteomWeaver software ranged between 18 and 69% for depleted plasma proteins, between 21 and 55% for platelet proteins, and between 22 and 38% for PBMC proteins. Subsequent manual matching improved the CV with on average between 1 and 16%. The average between laboratory CV for each of the matched spots after automatic matching ranged between 4 and 54% for depleted plasma proteins, between 5 and 60% for platelet proteins, and between 18 and 70% for PBMC proteins. This variation must be considered when designing sufficiently powered studies that use proteomics tools for biomarker discovery. The use of tricine in the running buffer for the second dimension appears to enhance the resolution of proteins especially in the high molecular weight range.


Subject(s)
Blood Platelets/chemistry , Blood Proteins/analysis , Leukocytes, Mononuclear/chemistry , Proteomics/methods , Blood Proteins/isolation & purification , Cell Separation/methods , Electrophoresis, Gel, Two-Dimensional/methods , Humans , Proteome/analysis , Proteome/isolation & purification , Reproducibility of Results , Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization/methods , Staining and Labeling/methods , Tandem Mass Spectrometry/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...