Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Br J Radiol ; 82(977): 386-91, 2009 May.
Article in English | MEDLINE | ID: mdl-19153187

ABSTRACT

Atrial septum defects (ASDs), ventricular septum defects (VSDs) and patent ductus arteriosus (PDA) are the most common adult congenital heart defects. The degree of left-to-right shunting as assessed by the ratio of flow in the pulmonary (Qp) and systemic circulation (Qs) is crucial in the management of these conditions. This study compared phase-contrast cine magnetic resonance imaging (PC-MRI), a non-invasive imaging technique, with invasive oximetry for the measurement of shunt volumes during cardiac catheterisation in adults with left-to-right shunting. Both invasive oximetry and shunt quantification by PC-MRI (1.5 T scanner; Sonata, Siemens Medical Solutions) were performed on 21 patients with left-to-right shunting (14 ASD, 5 VSD, 2 PDA) and data on Qp/Qs ratios and left-to-right shunt fraction compared. Mean Qp/Qs ratios assessed by PC-MRI and oximetry were 2.10+/-0.76 and 1.96+/-0.77, respectively (p = 0.37). Mean shunt fraction was 46.3+/-19.6% when calculated by PC-MRI and 42.3+/-20.1% when obtained by oximetry (p = 0.12). There was a strong correlation of Qp/Qs ratios and shunt fraction between both methods (r = 0.61, p < 0.01 and r = 0.84, p < 0.0001, respectively). The two methods had a good agreement according to Bland and Altman plots with a small but non-significant overestimation of Qp/Qs-ratios and shunt fraction by PC-MRI. On receiver operating characteristic analysis, the sensitivity and specificity of PC-MRI to detect an oximetry-derived Qp/Qs ratio of > or =1.5:1 were 93% and 100% at a PC-MRI threshold of a Qp/Qs ratio > or =1.75:1 (area under curve (AUC) = 0.99). Quantification of left-to-right shunting can be performed reliably and accurately by PC-MRI and the data obtained by this method correlate closely to those from invasive oximetry.


Subject(s)
Ductus Arteriosus, Patent/physiopathology , Heart Septal Defects, Atrial/physiopathology , Heart Septal Defects, Ventricular/physiopathology , Magnetic Resonance Imaging, Cine/methods , Oximetry/methods , Adult , Aged , Aorta/physiopathology , Cardiac Catheterization , Coronary Circulation/physiology , Ductus Arteriosus, Patent/diagnosis , Female , Heart Septal Defects, Atrial/diagnosis , Heart Septal Defects, Ventricular/diagnosis , Humans , Male , Middle Aged , Pulmonary Artery/physiopathology , Pulmonary Circulation/physiology , Reproducibility of Results , Sensitivity and Specificity
2.
Rofo ; 180(11): 983-7, 2008 Nov.
Article in English | MEDLINE | ID: mdl-18814102

ABSTRACT

PURPOSE: Congenitally malformed aortic valves are a common finding in adults with aortic valve disease. Most of these patients have bicuspid aortic valve disease. Unicuspid aortic valve disease (UAV) is rare. The aim of our study was to describe valve morphology and the dimensions of the proximal aorta in a cohort of 12 patients with UAV in comparison to tricuspid aortic valve disease (TAV) using magnetic resonance imaging (MRI). MATERIALS AND METHODS/RESULTS: MRI studies were performed on a 1.5 T scanner in a total of 288 consecutive patients with aortic valve disease. 12 aortic valves were retrospectively classified as UAV. Annulus areas and dimensions of the thoracic aorta were retrospectively compared to a cohort of 103 patients with TAV. In UAV, valve morphology was unicuspid unicommissural with a posterior commissure in all patients. Mean annulus areas and mean diameters of the ascending aorta were significantly greater in UAV compared to TAV (12.6 +/- 4.7 cm (2) vs. 8.7 +/- 2.3 cm (2), p < 0.01 and 4.6 +/- 0.7 cm vs. 3.6 +/- 0.5 cm, p < 0.0001, respectively), while no differences were observed in the mean diameters of the aortic arch (2.3 +/- 0.6 cm vs. 2.3 +/- 0.4 cm, p = 0.69). The diameters of the descending aorta were slightly smaller in UAV compared to TAV (2.2 +/- 0.5 cm vs. 2.6 +/- 0.3 cm, p < 0.05). CONCLUSION: In UAV, visualization of valve morphology by MRI is possible with good image quality. Valve morphology was classified as unicuspid unicommissural in all UAV patients. Dilatation of the proximal aorta > 4.5 cm is a frequent finding in UAV. Additional assessment of aortic dimensions is therefore recommended in patients with UAV.


Subject(s)
Aortic Valve Stenosis/pathology , Aortic Valve/abnormalities , Heart Valve Diseases/pathology , Rheumatic Heart Disease/pathology , Adult , Aortic Valve/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Blood Pressure , Diastole , Female , Heart Valve Diseases/diagnostic imaging , Heart Valve Diseases/surgery , Humans , Magnetic Resonance Imaging , Male , Middle Aged , Mitral Valve/pathology , Radiography , Retrospective Studies , Rheumatic Heart Disease/diagnostic imaging , Rheumatic Heart Disease/surgery , Systole
3.
Heart ; 94(3): e8, 2008 Mar.
Article in English | MEDLINE | ID: mdl-17686805

ABSTRACT

BACKGROUND: The aim of our study was to determine whether planimetry of the anatomic regurgitant orifice (ARO) in patients with aortic regurgitation (AR) by magnetic resonance imaging (MRI) is feasible and whether ARO by MRI correlates with the severity of AR. METHODS AND RESULTS: Planimetry of ARO by MRI was performed on a clinical magnetic resonance system (1.5 T Sonata, Siemens Medical Solutions) in 45 patients and correlated with the regurgitant fraction (RgF) and regurgitant volume (RgV) determined by MRI phase velocity mapping (PVM; MRI-RgF, MRI-RgV, n = 45) and with invasively quantified AR by supravalvular aortography (n = 32) and RgF upon cardiac catheterisation (CATH-RgF, n = 15). Determination of ARO was possible in 98% (44/45) of the patients with adequate image quality. MRI-RgF and CATH-RgF were modestly correlated (n = 15, r = 0.71, p<0.01). ARO was closely correlated with MRI-RgF (n = 44, r = 0.88, p<0.001) and was modestly correlated with CATH-RgF (n = 14, r = 0.66, p = 0.01). Sensitivity and specificity of ARO to detect moderately severe and severe aortic regurgitation (defined as MRI-RgF > or =40%) were 96% and 95% at a threshold of 0.28 cm2 (AUC = 0.99). Of note, sensitivity and specificity of ARO to detect moderately severe and severe AR at catheterisation (defined as CATH-RgF > or =40% or supravalvular aortography > or =3+) were 90% and 91% at a similar threshold of 0.28 cm2 (AUC = 0.95). Lastly, sensitivity and specificity of ARO to detect severe aortic regurgitation (defined as MRI-RgF > or =50% and/or regurgitant volume > or =60 ml) were 83% and 97% at a threshold of 0.48 cm2 (AUC = 0.97). CONCLUSIONS: Visualisation and planimetry of the ARO in patients with AR are feasible by MRI. There is a strong correlation of ARO with RgV and RgF assessed by PVM and with invasively graded AR at catheterisation. Therefore, determination of ARO by MRI is a new non-invasive measure for assessing the severity of AR.


Subject(s)
Aortic Valve Insufficiency/diagnosis , Magnetic Resonance Angiography/methods , Adult , Aged , Cardiac Catheterization/methods , Epidemiologic Methods , Female , Humans , Magnetic Resonance Angiography/standards , Male , Middle Aged
4.
Clin Res Cardiol ; 95(12): 650-6, 2006 Dec.
Article in English | MEDLINE | ID: mdl-16998740

ABSTRACT

BACKGROUND: In the diagnosis of coronary artery disease (CAD) with Dobutamine Stress Echocardiography (DSE), regional wall motion abnormalities (RWMA) are assumed to indicate a perfusion deficit. METHODS AND RESULTS: For a more particular examination of RWMAs, we compared simultaneous echo-contrast (Optisone)-enhanced DSE (0-40 microg/kg Dobutamine, 16-segment- model) and MiBi-SPECT in a prospective double-blinded study design in 69 non-selected consecutive patients (44 male, 25 female, age 64+/-12 years). Additionally, all patients were examined by coronary-angiography. The prevalence of significant CAD (stenosis >50% lumen diameter) was 52%. DSE had a sensitivity of 78% and a specificity of 66% for the detection of significant CAD with a positive and negative predictive value of 72 and 73%, respectively. Among 28 patients with significant CAD and positive DSE study (true positive), 78% displayed a corresponding perfusion deficit in MiBi-SPECT. Among 11 patients with a positive DSE study but no current significant coronary stenosis (false positive), 82% showed stress-induced RWMAs in the inferior/posterior region, 73% displayed left ventricular hypertrophy, 54% resting-ECG abnormalities and 45% resting-RWMA (3 previous MI, 2 previous CABG surgery). Among 8 patients with negative DSE study but significant coronary stenosis (false negative), 75% had a stenosis of the LCX, 63% displayed resting- WMA, 63% displayed left bundle branch block or ST-segment depression, 50% displayed only peripheral coronary stenosis, and DSE visualization was suboptimal in 38%. CONCLUSION: This prospective study in non-selected patients shows that the majority of RWMAs in DSE are matched to a perfusion deficit detectable by nuclear imaging. Nevertheless, pre-existing cardiac abnormalities may also lead to stress-induced RWMA not associated with a perfusion deficit or mask a perfusion deficit upon DSE. Particularly in patients with LV hypertrophy, resting-RWMA, bundle branch block or ST segment depression, the predictive value of DSE may, therefore, be limited.


Subject(s)
Coronary Artery Disease/physiopathology , Cardiotonic Agents , Chi-Square Distribution , Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Dobutamine , Female , Humans , Male , Middle Aged , Predictive Value of Tests , Radiopharmaceuticals , Sensitivity and Specificity , Technetium Tc 99m Sestamibi , Tomography, Emission-Computed, Single-Photon
SELECTION OF CITATIONS
SEARCH DETAIL
...