1.
Am J Physiol Lung Cell Mol Physiol ; 324(2): L102-L113, 2023 02 01.
Article in English | MEDLINE | ID: mdl-36511508

ABSTRACT

Assessment of native cardiac output during extracorporeal circulation is challenging. We assessed a modified Fick principle under conditions such as dead space and shunt in 13 anesthetized swine undergoing centrally cannulated veno-arterial extracorporeal membrane oxygenation (V-A ECMO, 308 measurement periods) therapy. We assumed that the ratio of carbon dioxide elimination (V̇co2) or oxygen uptake (V̇o2) between the membrane and native lung corresponds to the ratio of respective blood flows. Unequal ventilation/perfusion (V̇/Q̇) ratios were corrected towards unity. Pulmonary blood flow was calculated and compared to an ultrasonic flow probe on the pulmonary artery with a bias of 99 mL/min (limits of agreement -542 to 741 mL/min) with blood content V̇o2 and no-shunt, no-dead space conditions, which showed good trending ability (least significant change from 82 to 129 mL). Shunt conditions led to underestimation of native pulmonary blood flow (bias -395, limits of agreement -1,290 to 500 mL/min). Bias and trending further depended on the gas (O2, CO2) and measurement approach (blood content vs. gas phase). Measurements in the gas phase increased the bias (253 [LoA -1,357 to 1,863 mL/min] for expired V̇o2 bias 482 [LoA -760 to 1,724 mL/min] for expired V̇co2) and could be improved by correction of V̇/Q̇ inequalities. Our results show that common assumptions of the Fick principle in two competing circulations give results with adequate accuracy and may offer a clinically applicable tool. Precision depends on specific conditions. This highlights the complexity of gas exchange in membrane lungs and may further deepen the understanding of V-A ECMO.


Subject(s)
Extracorporeal Membrane Oxygenation , Pulmonary Gas Exchange , Animals , Swine , Pulmonary Gas Exchange/physiology , Extracorporeal Membrane Oxygenation/methods , Lung/blood supply , Cardiac Output/physiology , Pulmonary Artery , Carbon Dioxide
2.
Anesthesiology ; 133(4): 879-891, 2020 10 01.
Article in English | MEDLINE | ID: mdl-32657798

ABSTRACT

BACKGROUND: Veno-arterial extracorporeal membrane oxygenation therapy is a growing treatment modality for acute cardiorespiratory failure. Cardiac output monitoring during veno-arterial extracorporeal membrane oxygenation therapy remains challenging. This study aims to validate a new thermodilution technique during veno-arterial extracorporeal membrane oxygenation therapy using a pig model. METHODS: Sixteen healthy pigs were centrally cannulated for veno-arterial extracorporeal membrane oxygenation, and precision flow probes for blood flow assessment were placed on the pulmonary artery. After chest closure, cold boluses of 0.9% saline solution were injected into the extracorporeal membrane oxygenation circuit, right atrium, and right ventricle at different extracorporeal membrane oxygenation flows (4, 3, 2, 1 l/min). Rapid response thermistors in the extracorporeal membrane oxygenation circuit and pulmonary artery recorded the temperature change. After calculating catheter constants, the distributions of injection volumes passing each circuit were assessed and enabled calculation of pulmonary blood flow. Analysis of the exponential temperature decay allowed assessment of right ventricular function. RESULTS: Calculated blood flow correlated well with measured blood flow (r2 = 0.74, P < 0.001). Bias was -6 ml/min [95% CI ± 48 ml/min] with clinically acceptable limits of agreement (668 ml/min [95% CI ± 166 ml/min]). Percentage error varied with extracorporeal membrane oxygenation blood flow reductions, yielding an overall percentage error of 32.1% and a percentage error of 24.3% at low extracorporeal membrane oxygenation blood flows. Right ventricular ejection fraction was 17 [14 to 20.0]%. Extracorporeal membrane oxygenation flow reductions increased end-diastolic and end-systolic volumes with reductions in pulmonary vascular resistance. Central venous pressure and right ventricular ejection fractions remained unchanged. End-diastolic and end-systolic volumes correlated highly (r2 = 0.98, P < 0.001). CONCLUSIONS: Adapted thermodilution allows reliable assessment of cardiac output and right ventricular behavior. During veno-arterial extracorporeal membrane oxygenation weaning, the right ventricle dilates even with stable function, possibly because of increased venous return.


Subject(s)
Blood Flow Velocity/physiology , Extracorporeal Membrane Oxygenation/methods , Models, Animal , Thermodilution/methods , Ventricular Function, Right/physiology , Animals , Female , Lung/blood supply , Lung/physiology , Male , Swine