Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 39
Filter
1.
JACC Cardiovasc Interv ; 17(8): 979-988, 2024 Apr 22.
Article in English | MEDLINE | ID: mdl-38658126

ABSTRACT

BACKGROUND: Symptomatic patients with severe aortic stenosis (AS) at high risk for surgical aortic valve replacement (SAVR) sustain comparable improvements in health status over 5 years after transcatheter aortic valve replacement (TAVR) or SAVR. Whether a similar long-term benefit is observed among intermediate-risk AS patients is unknown. OBJECTIVES: The purpose of this study was to assess health status outcomes through 5 years in intermediate risk patients treated with a self-expanding TAVR prosthesis or SAVR using data from the SURTAVI (Surgical Replacement and Transcatheter Aortic Valve Implantation) trial. METHODS: Intermediate-risk patients randomized to transfemoral TAVR or SAVR in the SURTAVI trial had disease-specific health status assessed at baseline, 30 days, and annually to 5 years using the Kansas City Cardiomyopathy Questionnaire (KCCQ). Health status was compared between groups using fixed effects repeated measures modelling. RESULTS: Of the 1,584 patients (TAVR, n = 805; SAVR, n = 779) included in the analysis, health status improved more rapidly after TAVR compared with SAVR. However, by 1 year, both groups experienced large health status benefits (mean change in KCCQ-Overall Summary Score (KCCQ-OS) from baseline: TAVR: 20.5 ± 22.4; SAVR: 20.5 ± 22.2). This benefit was sustained, albeit modestly attenuated, at 5 years (mean change in KCCQ-OS from baseline: TAVR: 15.4 ± 25.1; SAVR: 14.3 ± 24.2). There were no significant differences in health status between the cohorts at 1 year or beyond. Similar findings were observed in the KCCQ subscales, although a substantial attenuation of benefit was noted in the physical limitation subscale over time in both groups. CONCLUSIONS: In intermediate-risk AS patients, both transfemoral TAVR and SAVR resulted in comparable and durable health status benefits to 5 years. Further research is necessary to elucidate the mechanisms for the small decline in health status noted at 5 years compared with 1 year in both groups. (Safety and Efficacy Study of the Medtronic CoreValve® System in the Treatment of Severe, Symptomatic Aortic Stenosis in Intermediate Risk Subjects Who Need Aortic Valve Replacement [SURTAVI]; NCT01586910).


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Femoral Artery , Health Status , Heart Valve Prosthesis , Quality of Life , Recovery of Function , Severity of Illness Index , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Female , Male , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Treatment Outcome , Aged , Aged, 80 and over , Risk Factors , Aortic Valve/surgery , Aortic Valve/physiopathology , Aortic Valve/diagnostic imaging , Risk Assessment , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/adverse effects , Catheterization, Peripheral/adverse effects , Punctures , Prosthesis Design
2.
Open Heart ; 10(1)2023 05.
Article in English | MEDLINE | ID: mdl-37173100

ABSTRACT

OBJECTIVE: To evaluate whether transcatheter or surgical aortic valve replacement (TAVR or SAVR) affects clinical and haemodynamic outcomes in symptomatic patients with moderately-severe aortic stenosis (AS). METHODS: Echocardiographic evidence of severe AS for enrolment in the Evolut Low Risk trial was based on site-reported measurements. For this post hoc analysis, core laboratory measurements identified patients with symptomatic moderately-severe AS (1.0

Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Heart Valve Prosthesis Implantation/adverse effects , Quality of Life , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/etiology , Treatment Outcome
3.
Article in English | MEDLINE | ID: mdl-36933787

ABSTRACT

OBJECTIVE: Evaluate the feasibility of prophylactic radiofrequency isolation of the pulmonary veins, with left atrial appendage amputation, to reduce the incidence of postoperative atrial fibrillation (POAF) after cardiac surgery in patients aged 70 and older. METHODS: The Federal Food and Drug Administration granted an investigational device exemption to utilize a bipolar radiofrequency clamp for prophylactic pulmonary vein isolation in a limited, feasibility trial. Sixty-two patients without prior dysrhythmias, were prospectively randomized to undergo either their index cardiac surgical procedure, or bilateral pulmonary vein isolation and left atrial appendage amputation during their cardiac operation. The primary outcome was occurrence of in-hospital POAF. Subjects were on 24-hour telemetry until discharge. Dysrhythmias, any episode of atrial fibrillation > 30 seconds, were confirmed by electrophysiologists blinded to the study. RESULTS: Sixty patients, mean age 75 years and mean CHA2DS2-VASc score 4, were analyzed. Thirty-one patients randomized to control and twenty-nine to the treatment group. Majority of cases in each group were isolated CABG. No perioperative complications related to the treatment procedure, need for permanent pacemaker, or mortality occurred. The in-hospital incidence of POAF was 55% (17/31) in the control group and 7% (2/29) in the treatment group. (p<0.001) The control group had a significantly higher requirement for antiarrhythmic medications at discharge, 45% (14/31) vs 7% (2/29) in the treatment group (p<0.001). CONCLUSIONS: Prophylactic radiofrequency isolation of the pulmonary veins with left atrial appendage amputation, during the primary cardiac surgical operation, reduced the incidence of POAF in patients 70 years and older with no history of atrial arrhythmias.

4.
JAMA Cardiol ; 8(2): 111-119, 2023 02 01.
Article in English | MEDLINE | ID: mdl-36515976

ABSTRACT

Importance: The frequency and clinical importance of structural valve deterioration (SVD) in patients undergoing self-expanding transcatheter aortic valve implantation (TAVI) or surgery is poorly understood. Objective: To evaluate the 5-year incidence, clinical outcomes, and predictors of hemodynamic SVD in patients undergoing self-expanding TAVI or surgery. Design, Setting, and Participants: This post hoc analysis pooled data from the CoreValve US High Risk Pivotal (n = 615) and SURTAVI (n = 1484) randomized clinical trials (RCTs); it was supplemented by the CoreValve Extreme Risk Pivotal trial (n = 485) and CoreValve Continued Access Study (n = 2178). Patients with severe aortic valve stenosis deemed to be at intermediate or increased risk of 30-day surgical mortality were included. Data were collected from December 2010 to June 2016, and data were analyzed from December 2021 to October 2022. Interventions: Patients were randomized to self-expanding TAVI or surgery in the RCTs or underwent self-expanding TAVI for clinical indications in the nonrandomized studies. Main Outcomes and Measures: The primary end point was the incidence of SVD through 5 years (from the RCTs). Factors associated with SVD and its association with clinical outcomes were evaluated for the pooled RCT and non-RCT population. SVD was defined as (1) an increase in mean gradient of 10 mm Hg or greater from discharge or at 30 days to last echocardiography with a final mean gradient of 20 mm Hg or greater or (2) new-onset moderate or severe intraprosthetic aortic regurgitation or an increase of 1 grade or more. Results: Of 4762 included patients, 2605 (54.7%) were male, and the mean (SD) age was 82.1 (7.4) years. A total of 2099 RCT patients, including 1128 who received TAVI and 971 who received surgery, and 2663 non-RCT patients who received TAVI were included. The cumulative incidence of SVD treating death as a competing risk was lower in patients undergoing TAVI than surgery (TAVI, 2.20%; surgery, 4.38%; hazard ratio [HR], 0.46; 95% CI, 0.27-0.78; P = .004). This lower risk was most pronounced in patients with smaller annuli (23 mm diameter or smaller; TAVI, 1.32%; surgery, 5.84%; HR, 0.21; 95% CI, 0.06-0.73; P = .02). SVD was associated with increased 5-year all-cause mortality (HR, 2.03; 95% CI, 1.46-2.82; P < .001), cardiovascular mortality (HR, 1.86; 95% CI, 1.20-2.90; P = .006), and valve disease or worsening heart failure hospitalizations (HR, 2.17; 95% CI, 1.23-3.84; P = .008). Predictors of SVD were developed from multivariate analysis. Conclusions and Relevance: This study found a lower rate of SVD in patients undergoing self-expanding TAVI vs surgery at 5 years. Doppler echocardiography was a valuable tool to detect SVD, which was associated with worse clinical outcomes. Trial Registration: ClinicalTrials.gov Identifiers: NCT01240902, NCT01586910, and NCT01531374.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Transcatheter Aortic Valve Replacement , Male , Humans , Aged, 80 and over , Female , Aortic Valve/surgery , Treatment Outcome , Transcatheter Aortic Valve Replacement/adverse effects
5.
JAMA Cardiol ; 7(10): 1000-1008, 2022 10 01.
Article in English | MEDLINE | ID: mdl-36001335

ABSTRACT

Importance: In patients with severe aortic valve stenosis at intermediate surgical risk, transcatheter aortic valve replacement (TAVR) with a self-expanding supra-annular valve was noninferior to surgery for all-cause mortality or disabling stroke at 2 years. Comparisons of longer-term clinical and hemodynamic outcomes in these patients are limited. Objective: To report prespecified secondary 5-year outcomes from the Symptomatic Aortic Stenosis in Intermediate Risk Subjects Who Need Aortic Valve Replacement (SURTAVI) randomized clinical trial. Design, Setting, and Participants: SURTAVI is a prospective randomized, unblinded clinical trial. Randomization was stratified by investigational site and need for revascularization determined by the local heart teams. Patients with severe aortic valve stenosis deemed to be at intermediate risk of 30-day surgical mortality were enrolled at 87 centers from June 19, 2012, to June 30, 2016, in Europe and North America. Analysis took place between August and October 2021. Intervention: Patients were randomized to TAVR with a self-expanding, supra-annular transcatheter or a surgical bioprosthesis. Main Outcomes and Measures: The prespecified secondary end points of death or disabling stroke and other adverse events and hemodynamic findings at 5 years. An independent clinical event committee adjudicated all serious adverse events and an independent echocardiographic core laboratory evaluated all echocardiograms at 5 years. Results: A total of 1660 individuals underwent an attempted TAVR (n = 864) or surgical (n = 796) procedure. The mean (SD) age was 79.8 (6.2) years, 724 (43.6%) were female, and the mean (SD) Society of Thoracic Surgery Predicted Risk of Mortality score was 4.5% (1.6%). At 5 years, the rates of death or disabling stroke were similar (TAVR, 31.3% vs surgery, 30.8%; hazard ratio, 1.02 [95% CI, 0.85-1.22]; P = .85). Transprosthetic gradients remained lower (mean [SD], 8.6 [5.5] mm Hg vs 11.2 [6.0] mm Hg; P < .001) and aortic valve areas were higher (mean [SD], 2.2 [0.7] cm2 vs 1.8 [0.6] cm2; P < .001) with TAVR vs surgery. More patients had moderate/severe paravalvular leak with TAVR than surgery (11 [3.0%] vs 2 [0.7%]; risk difference, 2.37% [95% CI, 0.17%- 4.85%]; P = .05). New pacemaker implantation rates were higher for TAVR than surgery at 5 years (289 [39.1%] vs 94 [15.1%]; hazard ratio, 3.30 [95% CI, 2.61-4.17]; log-rank P < .001), as were valve reintervention rates (27 [3.5%] vs 11 [1.9%]; hazard ratio, 2.21 [95% CI, 1.10-4.45]; log-rank P = .02), although between 2 and 5 years only 6 patients who underwent TAVR and 7 who underwent surgery required a reintervention. Conclusions and Relevance: Among intermediate-risk patients with symptomatic severe aortic stenosis, major clinical outcomes at 5 years were similar for TAVR and surgery. TAVR was associated with superior hemodynamic valve performance but also with more paravalvular leak and valve reinterventions.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Stroke , Aged , Aortic Valve/surgery , Aortic Valve Stenosis/complications , Female , Heart Valve Prosthesis/adverse effects , Humans , Male , Prospective Studies , Stroke/epidemiology , Stroke/etiology
6.
JACC Cardiovasc Interv ; 15(5): 511-522, 2022 03 14.
Article in English | MEDLINE | ID: mdl-35272776

ABSTRACT

OBJECTIVES: The aim of this study was to compare 1-year outcomes after transcatheter aortic valve replacement (TAVR) in low surgical risk patients with bicuspid aortic stenosis to patients with tricuspid aortic stenosis. BACKGROUND: The pivotal TAVR trials excluded patients with bicuspid aortic valves. The Low Risk Bicuspid Study 30-day primary endpoint of death or disabling stroke was 1.3%. METHODS: The Low Risk Bicuspid Study is a prospective, single-arm, TAVR trial that enrolled patients from 25 U.S. sites. A screening committee confirmed bicuspid anatomy and valve classification on computed tomography using the Sievers classification. Valve sizing was by annular measurements. An independent clinical events committee adjudicated all serious adverse events, and an independent core laboratory assessed all echocardiograms. The 150 patients from the Low Risk Bicuspid Study were propensity matched to the TAVR patients in the randomized Evolut Low Risk Trial using the 1:1 5- to-1-digit greedy method, resulting in 145 pairs. RESULTS: All-cause mortality or disabling stroke at 1 year was 1.4% in the bicuspid and 2.8% in the tricuspid group (P = 0.413). A pacemaker was implanted in 16.6% of bicuspid and 17.9% of tricuspid patients (P = 0.741). The effective orifice area was similar between groups at 1 year (2.2 ± 0.7 cm2 vs 2.3 ± 0.6 cm2, P = 0.677) as was the mean gradient (8.7 ± 3.9 mm Hg vs 8.5 ± 3.1 mm Hg, P = 0.754). Fewer patients in the bicuspid group had mild or worse paravalvular leak (21.3% vs 42.6%, P < 0.001). CONCLUSIONS: There were no significant differences in clinical or forward flow hemodynamic outcomes between the propensity-matched groups at 1 year.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/etiology , Aortic Valve Stenosis/surgery , Humans , Prospective Studies , Risk , Treatment Outcome
7.
J Am Coll Cardiol ; 79(9): 882-896, 2022 03 08.
Article in English | MEDLINE | ID: mdl-35241222

ABSTRACT

BACKGROUND: The Evolut Low Risk Trial (Medtronic Evolut Transcatheter Aortic Valve Replacement in Low Risk Patients) showed that transcatheter aortic valve replacement (TAVR) with a supra-annular, self-expanding valve was noninferior to surgery for the primary endpoint of all-cause mortality or disabling stroke at 2 years. This finding was based on a Bayesian analysis performed after 850 patients had reached 1 year of follow-up. OBJECTIVES: The goal of this study was to report the full 2-year clinical and echocardiographic outcomes for patients enrolled in the Evolut Low Risk Trial. METHODS: A total of 1,414 low-surgical risk patients with severe aortic stenosis were randomized to receive TAVR or surgical AVR. An independent clinical events committee adjudicated adverse events, and a central echocardiographic core laboratory assessed hemodynamic endpoints. RESULTS: An attempted implant was performed in 730 TAVR and 684 surgical patients from March 2016 to May 2019. The Kaplan-Meier rates for the complete 2-year primary endpoint of death or disabling stroke were 4.3% in the TAVR group and 6.3% in the surgery group (P = 0.084). These rates were comparable to the interim Bayesian rates of 5.3% with TAVR and 6.7% with surgery (difference: -1.4%; 95% Bayesian credible interval: -4.9% to 2.1%). All-cause mortality rates were 3.5% vs 4.4% (P = 0.366), and disabling stroke rates were 1.5% vs 2.7% (P = 0.119), respectively. Between years 1 and 2, there was no convergence of the primary outcome curves. CONCLUSIONS: The complete 2-year follow-up from the Evolut Low Risk Trial found that TAVR is noninferior to surgery for the primary endpoint of all-cause mortality or disabling stroke, with event rates that were slightly better than those predicted by using the Bayesian analysis. (Medtronic Evolut Transcatheter Aortic Valve Replacement in Low Risk Patients [Evolut Low Risk Trial]; NCT02701283).


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Stroke , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Bayes Theorem , Heart Valve Prosthesis/adverse effects , Humans , Prosthesis Design , Risk Factors , Stroke/epidemiology , Stroke/etiology , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
8.
Am J Cardiol ; 168: 110-116, 2022 04 01.
Article in English | MEDLINE | ID: mdl-35101271

ABSTRACT

Transcatheter aortic valve implantation (TAVI) has comparable outcomes with surgical aortic valve replacement (SAVR) in symptomatic patients with severe aortic stenosis, including those at low risk for surgery. Less is known about TAVI outcomes in asymptomatic patients. This analysis compares clinical, hemodynamic, and quality of life (QOL) outcomes after TAVI or SAVR for low-risk asymptomatic patients. The randomized Evolut Low Risk trial enrolled asymptomatic patients treated with TAVI (n = 76) and SAVR (n = 62). New York Heart Association functional class I identified patients without symptoms. Clinical outcomes, echocardiographic findings, and QOL in both groups were compared 30 days and 12 months after AVR. Asymptomatic patients had a mean Society of Thoracic Surgeons score of 1.7 ± 0.6, 73% were men, and mean age was 74.2 ± 5.8 years. The composite end point of all-cause mortality or disabling stroke was similar at 12 months in patients with TAVI (1.3%) and SAVR (6.5%; p = 0.11), although patients with SAVR tended to have higher rates of all-cause mortality (4.8%) compared with patients with TAVI (0.0%, p = 0.05). Patients with TAVI had lower mean aortic valve gradients (8.1 ± 3.2 mm Hg) and larger mean effective orifice area (2.3 ± 0.6 mm Hg) than patients with SAVR (10.8 ± 3.8; p <0.001 and 1.9 ± 0.6; p = 0.001, respectively), and showed significant improvement in Kansas City Cardiomyopathy Questionnaire scores from baseline to 30 days (∆12.1 ± 23.6; p <0.001), whereas patients with SAVR did not (∆2.2 ± 20.3; p = 0.398). Patients with TAVI and SAVR had a significant improvement in QOL by 12 months compared with baseline. In conclusion, low risk asymptomatic patients with severe aortic stenosis who underwent TAVI had comparable clinical outcomes to SAVR, with superior valve performance and faster QOL improvement.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Female , Humans , Male , Quality of Life , Risk Factors , Treatment Outcome
9.
JACC Cardiovasc Interv ; 15(1): 80-89, 2022 01 10.
Article in English | MEDLINE | ID: mdl-34747699

ABSTRACT

OBJECTIVES: The aim of this study was to evaluate outcomes of transcatheter mitral valve replacement (TMVR) with transfemoral access in patients at prohibitive or high surgical risk. BACKGROUND: Prohibitive surgical risk may preclude mitral valve replacement surgery in some patients. The investigational Intrepid TMVR system has previously been evaluated using transapical access for delivery of a self-expanding bioprosthetic valve. METHODS: This prospective, multicenter, nonrandomized early feasibility study evaluated the safety and performance of the Intrepid valve using transfemoral access enabling transseptal delivery in patients with moderate to severe or severe symptomatic mitral regurgitation at high surgical risk. Candidacy was determined by heart teams, with approval by a central screening committee. Echocardiographic data were evaluated by an independent core laboratory. Clinical events were adjudicated by a clinical events committee. RESULTS: Fifteen patients were enrolled at 6 sites from February 2020 to May 2021. The median age was 80 years, and median Society of Thoracic Surgeons Predicted Risk of Mortality was 4.7%; 87% of patients were men, and 53% had undergone prior sternotomy. Fourteen implants were successful. One patient was converted to surgery during the index procedure. Patients stayed a median of 5 days postprocedure. There were 6 access site bleeds (40%) and 11 iatrogenic atrial septal defect closures (73%). At 30 days, there were no deaths, strokes, or reinterventions. All patients undergoing implantation had trace or no valvular or paravalvular mitral regurgitation, and the mean gradient was 4.7 mm Hg (IQR: 3.0-6.7 mm Hg). CONCLUSIONS: Thirty-day results from the Intrepid transfemoral TMVR early feasibility study demonstrate excellent valve function and no mortality or stroke. Additional patients and longer follow-up are needed to confirm these findings. ([The Early Feasibility Study of the Intrepid™ TMVR Transseptal System]; NCT02322840).


Subject(s)
Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Mitral Valve Insufficiency , Aged, 80 and over , Cardiac Catheterization/adverse effects , Cardiac Catheterization/methods , Feasibility Studies , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/methods , Humans , Male , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/etiology , Mitral Valve Insufficiency/surgery , Prospective Studies , Treatment Outcome
10.
Semin Thorac Cardiovasc Surg ; 34(3): 870-877, 2022.
Article in English | MEDLINE | ID: mdl-34380081

ABSTRACT

Evaluate outcomes of the Freestyle stentless aortic bioprosthesis in patients 60 years old and younger. All patients, 60 years old and younger, between January 1, 1998 to December 31, 2015 who underwent implantation of a Freestyle aortic valve at a single institution were reviewed. Medical records and telephone interviews were utilized for data collection. 515 patients were identified with an average age of 51.3 years. Mean follow up was 11.1 years. 225 full root replacements and 290 subcoronary implants were performed. Overall survival, including patients with concomitant procedures, at 15 years was 63.7% (95% CI 58.3-68.5). Isolated subcoronary implants (58%,167/290) had a 15-year survival of 71.6% (95% CI 62.6-78.7) vs 78.4% (95% CI 69.7, 84.9) for isolated root replacements (63%,141/225) which was not statistically significant (P = 0.397). No significant difference in operative SVD at 15 years occurred between full root replacements 37.6% (95% CI 27.2-50.2) vs subcoronary implants 39.4% (95% CI31.1, 49.0). 110 patients required reoperation solely for intrinsic SVD. 93% (102/110) failed due to aortic insufficiency. Of reoperative interventions for SVD, 37% (41/110) of patients required urgent reoperation and 4.5% (5/110) required emergent reoperation. Pseudoaneurysms developed in six of the full root replacements. Freestyle aortic valves have a high rate of acute failure requiring urgent or emergent reintervention in patients 60 years old and younger. This has led our group to shift practice away from their implantation.


Subject(s)
Bioprosthesis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Follow-Up Studies , Humans , Middle Aged , Prosthesis Design , Treatment Outcome
11.
Ann Cardiothorac Surg ; 10(1): 141-148, 2021 Jan.
Article in English | MEDLINE | ID: mdl-33575184

ABSTRACT

BACKGROUND: Reductive annuloplasty repair of ischemic mitral regurgitation (IMR) is associated with high rates of recurrent MR, which may be improved with etiology-specific annuloplasty rings. METHODS: From October 2005 to May 2015, 128 consecutive patients underwent repair of IMR with the GeoForm ring. Clinical data was extracted from our local Society of Thoracic Surgeons database and electronic medical records. Mortality data was obtained from the Michigan State Social Security Death Index. RESULTS: The average age of patients was 65±11 years with mean pre-op left ventricular ejection fraction (LVEF) of 30%±10% and MR grade of 3.1±0.9 (0-4+). Thirty-day mortality was 4.7%, rate of renal failure 7.9%, rate of atrial fibrillation 27.3%, and no strokes were observed. Of the surviving patients, 89% (109/122) had a follow-up echocardiogram beyond 1 month with a mean echocardiographic follow-up of 59±39 months. LVEF improved from 30%±10% to 38%±14%, P<0.001) while end-diastolic (5.9±0.0 to 5.3±0.9 cm, P<0.001) and end-systolic (5.0±1.0 to 4.4±1.1 cm, P<0.001) left ventricular (LV) diameters decreased, as compared to pre-operative values. Seven patients were found to have recurrent moderate or greater IMR in follow-up to 10 years with three being due to ring dehiscence. One-, 5-, and 10-year freedom from recurrent moderate or severe IMR was 98%, 94%, and 80% respectively. One-, 5-, and 10-year survival was 91%, 77%, and 44%, respectively. CONCLUSIONS: Overall, etiology-specific ring repair of IMR was associated with low rates of recurrent MR on long-term follow-up, coupled with significant LV reverse remodeling and improvement in ejection fraction.

12.
EuroIntervention ; 16(10): 833-841, 2020 Nov 20.
Article in English | MEDLINE | ID: mdl-32715995

ABSTRACT

AIMS: In patients with aortic stenosis randomised to transcatheter aortic valve implantation (TAVI) or surgical aortic valve replacement (SAVR), sex-specific differences in complication rates are unclear in intermediate-risk patients. The purpose of this analysis was to identify sex-specific differences in outcome for patients at intermediate surgical risk randomised to TAVI or SAVR in the international Surgical Replacement and Transcatheter Aortic Valve Implantation (SURTAVI) trial. METHODS AND RESULTS: A total of 1,660 intermediate-risk patients underwent TAVI with a supra-annular, self-expanding bioprosthesis or SAVR. The population was stratified by sex and treatment modality (female TAVI=366, male TAVI=498, female SAVR=358, male SAVR=438). The primary endpoint was a composite of all-cause mortality or disabling stroke at two years. Compared to males, females had a smaller body surface area, a higher Society of Thoracic Surgeons score (4.7±1.6% vs 4.3±1.6%, p<0.01) and were more frail. Men required more concomitant revascularisation (23% vs 16%). All-cause mortality or disabling stroke at two years was similar between TAVI and SAVR for females (10.2% vs 10.5%, p=0.90) and males (14.5% vs 14.4%, p=0.99); the difference between females and males was 10.2% vs 14.5%, for TAVI (p=0.08) and 10.5% vs 14.4%, SAVR (p=0.13). Functional status improvement was more pronounced after TAVI in females than in males. CONCLUSIONS: Aortic valve replacement, either by surgical or transcatheter approach, appears similarly effective and safe for males and females at intermediate surgical risk. Functional status appears to improve most in females after TAVI. CLINICAL TRIAL REGISTRATION: http://clinicaltrials.gov NCT01586910.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Female , Humans , Male , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
13.
Ann Thorac Surg ; 110(6): 1951-1957, 2020 12.
Article in English | MEDLINE | ID: mdl-32442615

ABSTRACT

BACKGROUND: Valve-in-valve (ViV) transcatheter aortic valve replacement (TAVR) is acceptable in patients at high risk for reoperation. Studies suggest that ViV TAVR in stentless valves may be technically more challenging. This study sought to evaluate midterm outcomes for ViV TAVR in the degenerative Freestyle ((Medtronic, Minneapolis, MN)) stentless bioprosthesis. METHODS: Between October 2014 and January 2019, 56 patients underwent ViV TAVR for a failed Freestyle valve at a single institution using a commercially available self-expanding transcatheter aortic valve. Patient baseline characteristics and clinical outcomes data were collected retrospectively. Valve Academic Research Consortium-2 definitions were applied. RESULTS: Mean patient age was 75 ± 8 years and The Society of Thoracic Surgeons mean risk score was 9% ± 8%. The predominant mode of Freestyle valve failure was regurgitation (77%), and 36 patients (64%) required urgent intervention for refractory acute heart failure. Device success using a self-expanding TAVR was 82%, with 6 cases (11%) requiring deployment of two transcatheter valves. There were 3 operative mortalities (5%). At 30-day follow-up, no patient had greater than moderate perivalvular regurgitation. Device success was higher in the later patients compared with patients done earlier (P = .02). Mean aortic valve gradients at 30 days and 1 year were 11 ± 8 and 9 ± 8 mm Hg, respectively. For patients alive beyond day 30, 3-year survival was 82%. CONCLUSIONS: Performing ViV TAVR in the Freestyle valve using a self-expanding transcatheter valve presents a technical challenge, but may be feasible with good midterm results. Procedural success is associated with an early hazard learning curve.


Subject(s)
Aortic Valve Stenosis/surgery , Bioprosthesis/adverse effects , Heart Valve Prosthesis/adverse effects , Prosthesis Failure/adverse effects , Transcatheter Aortic Valve Replacement/methods , Aged , Aged, 80 and over , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Female , Humans , Male , Middle Aged , Prosthesis Design , Reoperation , Retrospective Studies , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Treatment Outcome
14.
Ann Thorac Surg ; 110(2): 508-515, 2020 08.
Article in English | MEDLINE | ID: mdl-31866480

ABSTRACT

BACKGROUND: The objective of this study was to compare long-term outcomes of Mosaic (Medtronic, Minneapolis, MN) porcine mitral valves to Carpentier-Edwards (Edwards Lifesciences, Irving, CA) bovine pericardial mitral valves. METHODS: From 2001 through 2017 at a single institution, 940 patients received a mitral bioprosthesis, of which 463 (49.3%) were porcine and 477 (50.7%) were bovine pericardial. Retrospective review of the procedure and the postoperative clinical course, including echocardiography, through August 2018 were analyzed. All consecutive mitral valve replacements over the study period were included. Follow-up was 99% (929 patients) complete for a total of 6045 patient-years (mean, 6.4 ± 4.5 years). A propensity-matched cohort of 802 mitral bioprosthesis was used for outcome analyses. RESULTS: Operative mortality of the 940 patients was 5.4% (n = 51) and incidence of postoperative stroke was 2.1% (n = 20). Overall survival of the propensity-matched patients at 10 and 15 years was 49.7% (95% confidence interval [CI] 45.5%-53.7%) and 23.3% (95% CI 17.9%-29.3%), respectively. Survival at 15 years was 24.0% (95% CI 18.0%-30.5%) for porcine and 16.5% (95% CI 5.5%-32.6%) for bovine implants, which was not significantly different (P = .67). Overall cumulative incidence for reoperative structural valve deterioration at 15 years was 7.9% (95% CI 4.7%-12.3%) for porcine valves versus 13.2% (95% CI 8.1%-19.5%) for pericardial valves (P < .001). For patients age younger than 65 years, structural valve deterioration at 15 years was 15.8% (95% CI 7.4%-27.0%) versus 30.2% (95% CI 15.1%-46.8%) for porcine and pericardial valves, respectively (P = .009). Overall average time to reoperation for structural valve deterioration for porcine valves was 11.1 ± 2.3 years vs 6.8 ± 2.3 years for bovine pericardial valves (P < .001). CONCLUSIONS: In long-term follow-up, of patients younger than 65 years of age undergoing mitral valve replacement, bovine pericardial valves experienced earlier and more frequent structural valve deterioration than porcine valves.


Subject(s)
Bioprosthesis , Forecasting , Heart Valve Diseases/surgery , Heart Valve Prosthesis Implantation/methods , Mitral Valve/surgery , Postoperative Complications/mortality , Propensity Score , Aged , Animals , Echocardiography , Female , Follow-Up Studies , Heart Valve Diseases/diagnosis , Heart Valve Diseases/mortality , Humans , Male , Michigan/epidemiology , Mitral Valve/diagnostic imaging , Prosthesis Design , Reoperation , Retrospective Studies , Risk Factors , Swine
15.
N Engl J Med ; 380(18): 1706-1715, 2019 05 02.
Article in English | MEDLINE | ID: mdl-30883053

ABSTRACT

BACKGROUND: Transcatheter aortic-valve replacement (TAVR) is an alternative to surgery in patients with severe aortic stenosis who are at increased risk for death from surgery; less is known about TAVR in low-risk patients. METHODS: We performed a randomized noninferiority trial in which TAVR with a self-expanding supraannular bioprosthesis was compared with surgical aortic-valve replacement in patients who had severe aortic stenosis and were at low surgical risk. When 850 patients had reached 12-month follow-up, we analyzed data regarding the primary end point, a composite of death or disabling stroke at 24 months, using Bayesian methods. RESULTS: Of the 1468 patients who underwent randomization, an attempted TAVR or surgical procedure was performed in 1403. The patients' mean age was 74 years. The 24-month estimated incidence of the primary end point was 5.3% in the TAVR group and 6.7% in the surgery group (difference, -1.4 percentage points; 95% Bayesian credible interval for difference, -4.9 to 2.1; posterior probability of noninferiority >0.999). At 30 days, patients who had undergone TAVR, as compared with surgery, had a lower incidence of disabling stroke (0.5% vs. 1.7%), bleeding complications (2.4% vs. 7.5%), acute kidney injury (0.9% vs. 2.8%), and atrial fibrillation (7.7% vs. 35.4%) and a higher incidence of moderate or severe aortic regurgitation (3.5% vs. 0.5%) and pacemaker implantation (17.4% vs. 6.1%). At 12 months, patients in the TAVR group had lower aortic-valve gradients than those in the surgery group (8.6 mm Hg vs. 11.2 mm Hg) and larger effective orifice areas (2.3 cm2 vs. 2.0 cm2). CONCLUSIONS: In patients with severe aortic stenosis who were at low surgical risk, TAVR with a self-expanding supraannular bioprosthesis was noninferior to surgery with respect to the composite end point of death or disabling stroke at 24 months. (Funded by Medtronic; ClinicalTrials.gov number, NCT02701283.).


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Bioprosthesis , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis , Prosthesis Design , Stroke/etiology , Transcatheter Aortic Valve Replacement/instrumentation , Aged , Aortic Valve Insufficiency/etiology , Aortic Valve Stenosis/complications , Aortic Valve Stenosis/mortality , Atrial Fibrillation/etiology , Bayes Theorem , Echocardiography , Female , Heart Valve Prosthesis Implantation/adverse effects , Humans , Kaplan-Meier Estimate , Length of Stay , Male , Postoperative Complications/epidemiology , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effects
16.
J Am Coll Cardiol ; 72(22): 2687-2696, 2018 12 04.
Article in English | MEDLINE | ID: mdl-30249462

ABSTRACT

BACKGROUND: The CoreValve U.S. Pivotal High Risk Trial was the first randomized trial to show superior 1-year mortality of transcatheter aortic valve replacement (TAVR) compared with surgical aortic valve replacement (SAVR) among high operative mortality-risk patients. OBJECTIVES: The authors sought to compare TAVR to SAVR for mid-term 5-year outcomes of safety, performance, and durability. METHODS: Surgical high-risk patients were randomized (1:1) to TAVR with the self-expanding bioprosthesis or SAVR. VARC-1 (Valve Academic Research Consortium I) definitions were applied. Severe hemodynamic structural valve deterioration was defined as a mean gradient ≥40 mm Hg or a change in gradient ≥20 mm Hg or new severe aortic regurgitation. Five-year follow-up was planned. RESULTS: A total of 797 patients were randomized at 45 U.S. centers, of whom 750 underwent an attempted implant (TAVR = 391, SAVR = 359). The overall mean age was 83 years, and the STS score was 7.4%. All-cause mortality rates at 5 years were 55.3% for TAVR and 55.4% for SAVR. Subgroup analysis showed no differences in mortality. Major stroke rates were 12.3% for TAVR and 13.2% for SAVR. Mean aortic valve gradients were 7.1 ± 3.6 mm Hg for TAVR and 10.9 ± 5.7 mm Hg for SAVR. No clinically significant valve thrombosis was observed. Freedom from severe SVD was 99.2% for TAVR and 98.3% for SAVR (p = 0.32), and freedom from valve reintervention was 97.0% for TAVR and 98.9% for SAVR (p = 0.04). A permanent pacemaker was implanted in 33.0% of TAVR and 19.8% of SAVR patients at 5 years. CONCLUSIONS: This study shows similar mid-term survival and stroke rates in high-risk patients following TAVR or SAVR. Severe structural valve deterioration and valve reinterventions were uncommon. (Safety and Efficacy Study of the Medtronic CoreValve® System in the Treatment of Symptomatic Severe Aortic Stenosis in High Risk and Very High Risk Subjects Who Need Aortic Valve Replacement; NCT01240902).


Subject(s)
Aortic Valve Insufficiency/mortality , Aortic Valve Insufficiency/surgery , Self Expandable Metallic Stents/trends , Transcatheter Aortic Valve Replacement/mortality , Transcatheter Aortic Valve Replacement/trends , Aged , Aged, 80 and over , Aortic Valve Insufficiency/diagnosis , Cohort Studies , Female , Follow-Up Studies , Humans , Male , Mortality/trends , Prospective Studies , Risk Factors , Self Expandable Metallic Stents/adverse effects , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
17.
J Thorac Cardiovasc Surg ; 155(5): 1991-1999, 2018 05.
Article in English | MEDLINE | ID: mdl-29429630

ABSTRACT

OBJECTIVES: Patients with symptomatic severe aortic stenosis and severe mitral regurgitation or severe tricuspid regurgitation were excluded from the major transcatheter aortic valve replacement trials. We studied these 2 subgroups in patients at extreme risk for surgery in the prospective, nonrandomized, single-arm CoreValve US Expanded Use Study. METHODS: The primary end point was all-cause mortality or major stroke at 1 year. A favorable medical benefit was defined as a Kansas City Cardiomyopathy Questionnaire overall summary score greater than 45 at 6 months and greater than 60 at 1 year and with a less than 10-point decrease from baseline. RESULTS: There were 53 patients in each group. Baseline characteristics for the severe mitral regurgitation and severe tricuspid regurgitation cohorts were age 84.2 ± 6.4 years and 84.9 ± 6.5 years; male, 29 (54.7%) and 22 (41.5%), and mean Society of Thoracic Surgeons score 9.9% ± 5.0% and 9.2% ± 4.0%, respectively. Improvement in valve regurgitation from baseline to 1 year occurred in 72.7% of the patients with severe mitral regurgitation and in 61.8% of patients with severe tricuspid regurgitation. A favorable medical benefit occurred in 31 of 47 patients (66.0%) with severe mitral regurgitation and 33 of 47 patients (70.2%) with severe tricuspid regurgitation at 6 months, and in 25 of 44 patients (56.8%) with severe mitral regurgitation and 24 of 45 patients (53.3%) with severe tricuspid regurgitation at 1 year. All-cause mortality or major stroke for the severe mitral regurgitation and severe tricuspid regurgitation cohorts were 11.3% and 3.8% at 30 days and 21.0% and 19.2% at 1 year, respectively. There were no major strokes in either group at 1 year. CONCLUSIONS: Transcatheter aortic valve replacement in patients with severe mitral regurgitation or severe tricuspid regurgitation is reasonable and safe and leads to improvement in atrioventricular valve regurgitation.


Subject(s)
Aortic Valve Stenosis/surgery , Transcatheter Aortic Valve Replacement , Tricuspid Valve Insufficiency/surgery , Aortic Valve/surgery , Cost-Benefit Analysis , Humans , Male , Prospective Studies , Treatment Outcome
18.
Ann Thorac Surg ; 105(4): 1129-1136, 2018 04.
Article in English | MEDLINE | ID: mdl-29307456

ABSTRACT

BACKGROUND: This analysis evaluates the relationship of annular size to hemodynamics and the incidence of prosthesis-patient mismatch (PPM) in surgical aortic valve replacement (SAVR) and transcatheter aortic valve replacement (TAVR) patients. METHODS: The CoreValve US Pivotal High Risk Trial, described previously, compared TAVR using a self-expanding valve with SAVR. Multislice computed tomography was used to categorize TAVR and SAVR subjects according to annular perimeter-derived diameter: large (≥26 mm), medium (23 to <26 mm), and small (<23 mm). Hemodynamics, PPM, and clinical outcomes were assessed. RESULTS: At all postprocedure visits, mean gradients were significantly lower for TAVR compared with SAVR in small and medium size annuli (p < 0.001). Annular size was significantly associated with mean gradient after SAVR, with small annuli having the highest gradients (p < 0.05 at all timepoints); gradients were similar across all annular sizes after TAVR. In subjects receiving SAVR, the frequency of PPM was significantly associated with annular size, with small annuli having the greatest incidence. No difference in PPM incidence by annular sizing was observed with TAVR. In addition, TAVR subjects had significantly less PPM than SAVR subjects in small and medium annuli (p < 0.001), with no difference in the incidence of PPM between TAVR and SAVR in large annuli (p = 0.10). CONCLUSIONS: Annular size has a significant effect on hemodynamics and the incidence of PPM in SAVR subjects, not observed in TAVR subjects. With respect to annular size, TAVR results in better hemodynamics and less PPM for annuli less than 26 mm and should be strongly considered when choosing a tissue valve for small and medium size annuli.


Subject(s)
Aortic Valve Stenosis/surgery , Heart Valve Prosthesis , Postoperative Complications/epidemiology , Transcatheter Aortic Valve Replacement , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/physiopathology , Echocardiography, Doppler , Female , Hemodynamics , Humans , Incidence , Male , Multidetector Computed Tomography , Prosthesis Design , Treatment Outcome
19.
Semin Thorac Cardiovasc Surg ; 30(3): 262-268, 2018.
Article in English | MEDLINE | ID: mdl-29158054

ABSTRACT

Transcatheter aortic valve replacement (TAVR) is used increasingly to treat bioprosthetic valve failure. A paucity of data exists regarding valve-in-valve (ViV) TAVR in degenerated Freestyle stentless bioprostheses (FSBs). This study sought to evaluate the feasibility and short-term outcomes of ViV TAVR in previously placed FSB. From October 2014 to September 2016, 22 patients at a single institution underwent ViV TAVR with a self-expanding transcatheter valve for a failing FSB. Patient baseline characteristics and clinical outcomes data were collected retrospectively and entered into a dedicated database. The mean patient age was 74 ± 9 years, and the mean Society of Thoracic Surgeons' Risk score was 9.0 ± 7.4%. Ten patients presented with acute heart failure requiring urgent intervention. The most common mode of failure of the FSB was regurgitation caused by a flail or malcoapting leaflet. Seventeen (77%) patients had a modified subcoronary implantation, 3 (14%) had a full root replacement, and 2 (9%) had a root inclusion. Device success using a self-expanding transcatheter valve was 95%, all via transfemoral approach. The mean implant depth was 7 ± 3 mm. Thirty-day survival was 100%. No patient had more than mild paravalvular regurgitation at 30 days, and the permanent pacemaker rate was 9%. The mean hospital stay after intervention was 5 ± 2 days. ViV TAVR using a self-expanding transcatheter valve is safe, feasible, and can be used successfully to treat a failed FSB. Procedural challenges suggest referral to valve centers of excellence.


Subject(s)
Aortic Valve Insufficiency/surgery , Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Bioprosthesis , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis , Prosthesis Failure , Transcatheter Aortic Valve Replacement/instrumentation , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/mortality , Aortic Valve Insufficiency/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/physiopathology , Feasibility Studies , Female , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/mortality , Humans , Male , Middle Aged , Prosthesis Design , Retrospective Studies , Risk Factors , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome
20.
J Cardiothorac Surg ; 12(1): 45, 2017 May 31.
Article in English | MEDLINE | ID: mdl-28569201

ABSTRACT

BACKGROUND: To compare the perioperative and long term survival after aortic valve replacement using stentless versus stented valves in a large cohort of patients grouped using propensity score matching. METHODS: From 1991 to 2012, 4,563 patients underwent aortic valve replacement with stentless and stented valves at our institution. Propensity score matching identified 444 pairs using 13 independent variables: incidence of operation, smoking status, renal failure, hypertension, diabetes, peripheral vascular disease, cerebrovascular disease, chronic lung disease, ejection fraction, gender, age, valve status, and use of coronary artery bypass graft. Data were collected from our Society of Thoracic Surgeons database and the Social Security Death Index. Groups were compared using univariate and Kaplan-Meier analysis. RESULTS: The two groups demonstrated no significant differences for the 13 matching variables and the majority of 30-day outcomes (p > 0.05). The stented valve group showed a higher incidence of postoperative bleeding (3.6% vs 1.1%, p = 0.015), but a lower incidence of stroke (0.9% vs. 2.9%, p = 0.028). One, five, and 10-year survival was 95.0, 80.7, and 52.8% for stented and 93.2, 80.5, and 51.3% for stentless valves. Overall survival did not differ significantly between the two groups (p = 0.641). CONCLUSIONS: Stentless and stented valves had identical 30-day outcomes except for a higher postoperative incidence of bleeding and a lower incidence of stroke in the stented group. There was no significant difference in long term survival between valve types. Both valves may be used for aortic valve replacement with low morbidity and excellent long term survival.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Bioprosthesis , Heart Valve Prosthesis , Postoperative Complications/epidemiology , Propensity Score , Stents , Aged , Aortic Valve Stenosis/mortality , Female , Follow-Up Studies , Humans , Incidence , Kaplan-Meier Estimate , Male , Time Factors , United States/epidemiology
SELECTION OF CITATIONS
SEARCH DETAIL
...