Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Int J Numer Method Biomed Eng ; 39(3): e3685, 2023 03.
Article in English | MEDLINE | ID: mdl-36645263

ABSTRACT

The purpose of this work is to present a patient-specific (PS) modeling approach for simulating percutaneous transluminal angioplasty (PTA) endovascular treatment and assessing the balloon sizing influence on short-term outcomes in peripheral arteries, i.e. without stent implantation. Two 3D PS stenosed femoral artery models, one with a dominant calcified atherosclerosis while the other with a lipidic plaque, were generated from pre-operative computed tomography angiography images. Elastoplastic constitutive laws were implemented within the plaque and artery models. Implicit finite element method (FEM) was used to simulate the balloon inflation and deflation for different sizings. Besides vessel strains, results were mainly evaluated in terms of the elastic recoil ratio (ERR) and lumen gain ratio (LGR) attained immediately after PTA. Higher LGR values were shown within the stenosed region of the lipidic patient. Simulated results also showed a direct and quantified correlation between balloon sizing and LGR and ERR for both patients after PTA, with a more significant influence on the lumen gain. The max principal strain values in the outer arterial wall increased at higher balloon sizes during inflation as well, with higher rates of increase when the plaque was calcified. Results show that our model could serve in finding a compromise for each stenosis type: maximizing the achieved lumen gain after PTA, but at the same time without damaging the arterial tissue. The proposed methodology can serve as a step toward a clinical decision support system to improve angioplasty balloon sizing selection prior to the surgery.


Subject(s)
Angioplasty, Balloon , Angioplasty , Humans , Finite Element Analysis , Angioplasty/methods , Femoral Artery/surgery , Constriction, Pathologic , Stents , Treatment Outcome
2.
Int J Numer Method Biomed Eng ; 37(8): e3499, 2021 08.
Article in English | MEDLINE | ID: mdl-33998779

ABSTRACT

In this work we propose a generic modeling approach for simulating percutaneous transluminal angioplasty (PTA) endovascular treatment, and evaluating the influence of balloon design, plaque composition, and balloon sizing on acute post-procedural outcomes right after PTA, without stent implantation. Clinically-used PTA balloons were classified into two categories according to their compliance characteristics, and were modeled correspondingly. Self-defined elastoplastic constitutive laws were implemented within the plaque and artery models, after calibration based on experimental and clinical data. Finite element method (FEM) implicit solver was used to simulate balloon inflation and deflation. Besides balloon profile at max inflation, results are mainly assessed in terms of the elastic recoil ratio (ERR) and lumen gain ratio (LGR) obtained immediately after PTA. No variations in ERR nor LGR values were detected when the balloon design changed, despite the differences observed in their profile at max inflation. Moreover, LGR and ERR inversely varied with the augmentation of calcification level within the plaque (-11% vs. +4% respectively, from fully lipidic to fully calcified plaque). Furthermore, results showed a direct correlation between balloon sizing and LGR and ERR, with noticeably higher rates of change for LGR (+18% and +2% for LGR and ERR respectively for a calcified plaque and a balloon pressure increasing from 10 to 14 atm). However a larger LGR comes with a higher risk of arterial rupture. This proposed methodology opens the way for evaluation of angioplasty balloon selections towards clinical procedure optimization.


Subject(s)
Angioplasty, Balloon , Plaque, Atherosclerotic , Angioplasty , Finite Element Analysis , Humans , Plaque, Atherosclerotic/therapy , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...