Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Chemosphere ; 214: 729-737, 2019 Jan.
Article in English | MEDLINE | ID: mdl-30293026

ABSTRACT

Per- and polyfluoroalkyl substances (PFASs) are utilized in specific firefighting foams. The objectives of this study were i) to map PFAS distribution in the soil and groundwater of a firefighter training site active for more than 3 decades, ii) to locate the main points of entry of PFASs into the aquifer and iii) to identify which PFASs seeped most deeply into the soil. A total of 44 soil cores and 17 groundwater samples were collected. Perfluorooctane sulfonate (PFOS), 6:2 fluorotelomer sulfonic acid (6:2 FTSA) and 6:2 Fluorotelomer sulfonamide alkylbetaine (6:2 FTAB) were the most predominant PFASs in surface soil. The highest total PFAS concentrations (up to 357 µg/g) were measured in two areas. Both areas were considered as potential points of entry of PFASs into the aquifer since PFASs were detected in soil 15 m below the surface, despite the presence of clay layers. The highest total PFAS concentrations were recorded in the monitoring wells located in the perimeter of the firefighter training site and in the spring located downgradient in the direction of groundwater flow. They ranged from 300 to 8300 ng/L. The fluorotelomer 6:2 FTAB was quantified in 6 monitoring wells, suggesting that this FT can reach a water table 20 m below the ground's surface.


Subject(s)
Flame Retardants/analysis , Groundwater/chemistry , Soil Pollutants/analysis , Soil/chemistry , Sulfonic Acids/analysis , Water Pollutants, Chemical/analysis , Alkanesulfonic Acids/analysis , Firefighters , Fluorocarbons/analysis
2.
Sci Total Environ ; 583: 393-400, 2017 Apr 01.
Article in English | MEDLINE | ID: mdl-28117151

ABSTRACT

Perfluoroalkyl and polyfluoroalkyl substances (PFASs) are emerging contaminants that have been detected in the environment, biota and humans. Drinking water is a route of exposure for populations using water contaminated by PFAS discharges. This research entailed measuring concentrations, mass flows and investigating the fate of dozens PFASs in a river receiving effluents from a fluorochemical manufacturing facility. To measure the total concentration of perfluoroalkyl carboxylic acid (PFCA) precursors, an oxidative conversion method was used. Several dozen samples were collected in the river (water and sediment), in drinking water resources and at different treatment steps on four sampling dates. One PFCA and three fluorotelomers (FTs) were detected up to 62km downstream from the manufacturing facility. 6:2 Fluorotelomer sulfonamide alkylbetaine (6:2 FTAB) was the predominant PFAS with a mass flow of 3830g/day 5.2km downstream from the facility. At all sampling points, PFAS concentrations in sediment were quite low (<6ng/g dw). Five of the 11 investigated wells showed detectable concentrations of PFASs. Interestingly, their profile patterns were different from those observed in the river, suggesting a transformation of PFCA precursors in the sediments of alluvial groundwater. Conventional drinking water treatments (aeration, sand or granular activated carbon filtration, ozonation or chlorination) did not efficiently remove PFASs. Furthermore, an increase in concentration of certain PFASs was observed after ozonation, suggesting that some FTs such as 6:2 FTAB can break down. Only nanofiltration was able to remove all the analyzed PFASs. In the treated water, total PFAS concentrations never exceeded 60ng/L. The oxidative conversion method revealed the presence of unidentified PFCA precursors in the river. Therefore, 18 to 77% of the total PFCA content after oxidation consisted of unidentified chemical species. In the treated water, these percentages ranged from 0 to 29%, relatively and reassuringly low values.


Subject(s)
Drinking Water/chemistry , Environmental Monitoring , Fluorocarbons/analysis , Water Pollutants, Chemical/analysis , Water Purification , Alkanesulfonic Acids/analysis , Groundwater/chemistry
3.
Environ Sci Pollut Res Int ; 24(5): 4916-4925, 2017 Feb.
Article in English | MEDLINE | ID: mdl-27988902

ABSTRACT

Perfluoroalkyl and polyfluoroalkyl substances (PFASs) are emerging contaminants that have been detected in the environment, biota, and humans. Drinking water is a route of exposure for populations consuming water contaminated by PFAS discharges. This research study reports environmental measurement concentrations, mass flows, and the fate of dozens of PFASs in a river receiving effluents from two fluoropolymer manufacturing facilities. In addition to quantified levels of PFASs using LC- and GC-MS analytical methods, the total amount of unidentified PFASs and precursors was assessed using two complementary analytical methods, absorbable organic fluorine (AOF) determination and oxidative conversion of perfluoroalkyl carboxylic acid (PFCA) precursors. Several dozen samples were collected in the river (water and sediment) during four sampling campaigns. In addition, samples were collected in two well fields and from the outlet of the drinking water treatment plants after chlorination. We estimated that 4295 kg PFHxA, 1487 kg 6:2FTSA, 965 kg PFNA, 307 kg PFUnDA, and 14 kg PFOA were discharged in the river by the two facilities in 2013. High concentrations (up to 176 ng/g dw) of odd long-chain PFASs (PFUnDA and PFTrDA) were found in sediment samples. PFASs were detected in all 15 wells, with concentrations varying based on the location of the well in the field. Additionally, the presence of previously discharged PFASs was still measurable. Significant discrepancies between PFAS concentration profiles in the wells and in the river suggest an accumulation and transformation of PFCA precursors in the aquifer. Chlorination had no removal efficiency and no unidentified PFASs were detected in the treated water with either complementary analytical method. Although the total PFAS concentrations were high in the treated water, ranging from 86 to 169 ng/L, they did not exceed the currently available guideline values.


Subject(s)
Drinking Water , Fluorocarbons/analysis , Rivers , Water Pollutants, Chemical/analysis , Fluorine , Groundwater , Humans , Manufacturing and Industrial Facilities , Water Purification , Water Resources
4.
Sci Total Environ ; 576: 549-558, 2017 Jan 15.
Article in English | MEDLINE | ID: mdl-27810744

ABSTRACT

Although industrial sites producing perfluoroalkyl and polyfluoroalkyl substances (PFASs) may introduce these chemicals into the aquatic environment, they are rarely investigated. This study entailed measuring concentrations, mass flows and the fate of 51 PFASs in an industrial wastewater treatment plant receiving raw effluents from a fluorochemical manufacturing facility. Grab and 24-h composite samples were collected at various stages of wastewater treatment over four sampling campaigns. One perfluoroalkyl carboxylic acid (PFCA) and nine fluorotelomers (FTs) were systematically detected in the facility's raw effluent. The overall PFCA mass flow ranged from 0.6 to 8.6g/day and was negligible compared to the overall mass flow of FTs (from 647 to 2,892g/day). PFCA mass flows increased drastically after secondary treatment (degradation of precursors) and decreased notably after the floatation tank (adsorption onto floatation sludge), but remained at relatively high levels in the final effluent (from 21 to 247g/day). Similar patterns in mass flow were observed for the FTs, with mass loadings discharged into the river ranging from 1,623 to 6,963g/day. Despite analyzing dozens of PFASs, adsorbable organic fluorine determination and oxidative conversion of PFCA precursors showed that a significant part of PFASs remained unidentified. Nevertheless, two overwhelmingly predominant PFASs-6:2 Fluorotelomer sulfonamide alkylbetaine (6:2 FTAB) and 6:2 Fluorotelomer sulfonamide propyl N,N dimethylamine (M4)-were detected and quantified for the first time in water samples, accounting for >75% of the total PFAS mass flow in the final effluent. This study also provided evidence of soil contamination by the aerosol produced over the aeration basin and inadvertent spillage of pieces of sludge cake.

5.
J Chromatogr A ; 1448: 98-106, 2016 May 27.
Article in English | MEDLINE | ID: mdl-27125188

ABSTRACT

Here, we developed and validated a headspace-solid-phase microextraction-gas chromatography/mass spectrometry (HS-SPME-GC/MS) method for the determination of 14 volatile perfluorinated alkylated substances (PFASs) in water and sediment samples according to SANTE 11945/2015 guidelines. Three fluorotelomer alcohols (FTOHs), two perfluoroalkyl iodides (PFIs), three fluorotelomer iodides (FTIs), four fluorotelomer acrylates and methacrylates (FTACs and FTMACs) and two perfluoroalkyl sulfonamides (FASAs) were analysed simultaneously to assess the occurrence of these compounds from their emission sources to the outlets in water treatment plants. Several SPME parameters were optimised for both water and sediment to maximise responses and keep analysis time to a minimum. In tap water, the limits of quantification (LOQs) were found to be between 20ng/L and 100ng/L depending on the analyte, with mean recoveries ranging from 76 to 126%. For sediments, LOQs ranged from 1 to 3ng/g dry weight depending on the target compound, with mean recoveries ranging from 74 to 125%. SPME considerably reduced sample preparation time and its use provided a sensitive, fast and simple technique. We then used this HS-SPME-GC/MS method to investigate the presence of volatile PFASs in the vicinity of an industrial facility. Only 8:2 FTOH and 10:2 FTOH were detected in a few water and sediment samples at sub-ppb concentration levels. Moreover, several non-target fluorotelomers (12:2 FTOH, 14:2 FTOH and 10:2 FTI) were identified in raw effluent samples. These long-chain fluorotelomers have high bioaccumulative potential in the aquatic environment compared with short-chain fluorotelomers such as 6:2 FTOH and 6:2 FTI.


Subject(s)
Acrylates/analysis , Hydrocarbons, Fluorinated/analysis , Methacrylates/analysis , Water Pollutants, Chemical/analysis , Alcohols/chemistry , Fluorocarbon Polymers , Gas Chromatography-Mass Spectrometry/methods , Geologic Sediments/chemistry , Solid Phase Microextraction , Sulfonamides/analysis
SELECTION OF CITATIONS
SEARCH DETAIL
...