Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
J Tissue Eng Regen Med ; 12(5): 1273-1284, 2018 05.
Article in English | MEDLINE | ID: mdl-29499107

ABSTRACT

Hepatic differentiation of human-induced pluripotent stem cells (hiPSCs) under flow conditions in a 3D scaffold is expected to be a major step forward for construction of bioartificial livers. The aims of this study were to induce hepatic differentiation of hiPSCs under perfusion conditions and to perform functional comparisons with fresh human precision-cut liver slices (hPCLS), an excellent benchmark for the human liver in vivo. The majority of the mRNA expression of CYP isoenzymes and transporters and the tested CYP activities, Phase II metabolism, and albumin, urea, and bile acid synthesis in the hiPSC-derived cells reached values that overlap those of hPCLS, which indicates a higher degree of hepatic differentiation than observed until now. Differentiation under flow compared with static conditions had a strong inducing effect on Phase II metabolism and suppressed AFP expression but resulted in slightly lower activity of some of the Phase I metabolism enzymes. Gene expression data indicate that hiPSCs differentiated into both hepatic and biliary directions. In conclusion, the hiPSC differentiated under flow conditions towards hepatocytes express a wide spectrum of liver functions at levels comparable with hPCLS indicating excellent future perspectives for the development of a bioartificial liver system for toxicity testing or as liver support device for patients.


Subject(s)
Cell Differentiation , Hepatocytes/cytology , Induced Pluripotent Stem Cells/cytology , Liver/physiology , Rheology , Tissue Engineering/methods , Albumins/biosynthesis , Bile Acids and Salts/metabolism , Biomarkers/metabolism , Cells, Cultured , Gene Expression Regulation , Hepatocytes/metabolism , Humans , Induced Pluripotent Stem Cells/metabolism , Tissue Scaffolds/chemistry , Urea/metabolism
2.
Biomacromolecules ; 17(4): 1321-9, 2016 Apr 11.
Article in English | MEDLINE | ID: mdl-26902925

ABSTRACT

Scaffolds with multiple functionalities have attracted widespread attention in the field of tissue engineering due to their ability to control cell behavior through various cues, including mechanical, chemical, and electrical. Fabrication of such scaffolds from clinically approved materials is currently a huge challenge. The goal of this work was to fabricate a tissue engineering scaffold from clinically approved materials with the capability of delivering biomolecules and direct cell fate. We have used a simple 3D printing approach, that combines polymer casting with supercritical fluid technology to produce 3D interpenetrating polymer network (IPN) scaffold of silicone-poly(2-hydroxyethyl methacrylate)-co-poly(ethylene glycol) methyl ether acrylate (pHEMA-co-PEGMEA). The pHEMA-co-PEGMEA IPN materials were employed to support growth of human mesenchymal stem cells (hMSC), resulting in high cell viability and metabolic activity over a 3 weeks period. In addition, the IPN scaffolds support 3D tissue formation inside the porous scaffold with well spread cell morphology on the surface of the scaffold. As a proof of concept, sustained doxycycline (DOX) release from pHEMA-co-PEGMEA IPN was demonstrated and the biological activity of released drug from IPN was confirmed using a DOX regulated green fluorescent reporter (GFP) gene expression assay with HeLa cells. Given its unique mechanical and drug releasing characteristics, IPN scaffolds may be used for directing stem cell differentiation by releasing various chemicals from its hydrogel network.


Subject(s)
Biocompatible Materials/pharmacology , Cell Differentiation/drug effects , Hydrogels/pharmacology , Mesenchymal Stem Cells/cytology , Silicones/chemistry , Tissue Engineering/methods , Tissue Scaffolds/chemistry , Biocompatible Materials/chemistry , Cell Line, Tumor , Cell Proliferation/drug effects , Cell Survival/drug effects , Doxycycline/chemistry , Drug Liberation , HeLa Cells , Humans , Hydrogels/chemistry , Mesenchymal Stem Cells/drug effects , Methacrylates/chemistry , Printing, Three-Dimensional
3.
Biosens Bioelectron ; 63: 72-79, 2015 Jan 15.
Article in English | MEDLINE | ID: mdl-25058941

ABSTRACT

A bioimpedance platform is presented as a promising tool for non-invasive real-time monitoring of the entire process of three-dimensional (3D) cell culturing in a hydrogel scaffold. In this study, the dynamics involved in the whole process of 3D cell culturing, starting from polymerisation of a bare 3D gelatin scaffold, to human mesenchymal stem cell (MSC) encapsulation and proliferation, was monitored over time. The platform consists of a large rectangular culture chamber with four embedded vertical gold plate electrodes that were exploited in two- and three terminal (2T and 3T) measurement configurations. By switching between the different combinations of electrode couples, it was possible to generate a multiplexing-like approach, which allowed for collecting spatially distributed information within the 3D space. Computational finite element (FE) analysis and electrochemical impedance spectroscopic (EIS) characterisation were used to determine the configurations' sensitivity field localisation. The 2T setup gives insight into the interfacial phenomena at both electrode surfaces and covers the central part of the 3D cell culture volume, while the four 3T modes provide focus on the dynamics at the corners of the 3D culture chamber. By combining a number of electrode configurations, complementary spatially distributed information on a large 3D cell culture can be obtained with maximised sensitivity in the entire 3D space. The experimental results show that cell proliferation can be monitored within the tested biomimetic environment, paving the way to further developments in bioimpedance tracking of 3D cell cultures and tissue engineering.


Subject(s)
Biosensing Techniques , Cell Culture Techniques , Mesenchymal Stem Cells/cytology , Tissue Engineering , Dielectric Spectroscopy , Electrodes , Finite Element Analysis , Gelatin/chemistry , Humans , Hydrogel, Polyethylene Glycol Dimethacrylate/chemistry , Mesenchymal Stem Cells/chemistry
4.
PLoS One ; 8(5): e63638, 2013.
Article in English | MEDLINE | ID: mdl-23723991

ABSTRACT

INTRODUCTION: High cell density is known to enhance adipogenic differentiation of mesenchymal stem cells, suggesting secretion of signaling factors or cell-contact-mediated signaling. By employing microfluidic biochip technology, we have been able to separate these two processes and study the secretion pathways. METHODS AND RESULTS: Adipogenic differentiation of human adipose-derived stem cells (ASCs) cultured in a microfluidic system was investigated under perfusion conditions with an adipogenic medium or an adipogenic medium supplemented with supernatant from differentiating ASCs (conditioned medium). Conditioned medium increased adipogenic differentiation compared to adipogenic medium with respect to accumulation of lipid-filled vacuoles and gene expression of key adipogenic markers (C/EBPα, C/EBPß, C/EBPδ, PPARγ, LPL and adiponectin). The positive effects of conditioned medium were observed early in the differentiation process. CONCLUSIONS: Using different cell densities and microfluidic perfusion cell cultures to suppress the effects of cell-released factors, we have demonstrated the significant role played by auto- or paracrine signaling in adipocyte differentiation. The cell-released factor(s) were shown to act in the recruitment phase of the differentiation process.


Subject(s)
Adipogenesis , Adipose Tissue/cytology , Autocrine Communication , Paracrine Communication , Stem Cells/cytology , Stem Cells/metabolism , Adipogenesis/drug effects , Autocrine Communication/drug effects , Biomarkers/metabolism , Computer Simulation , Culture Media, Conditioned/pharmacology , Humans , Lipid Metabolism/drug effects , Models, Biological , Paracrine Communication/drug effects , Stem Cells/drug effects , Time Factors
5.
J Lab Autom ; 18(3): 212-28, 2013 Jun.
Article in English | MEDLINE | ID: mdl-23015520

ABSTRACT

A microfluidic component library for building systems driving parallel or serial microfluidic-based assays is presented. The components are a miniaturized eight-channel peristaltic pump, an eight-channel valve, sample-to-waste liquid management, and interconnections. The library of components was tested by constructing various systems supporting perfusion cell culture, automated DNA hybridizations, and in situ hybridizations. The results showed that the MainSTREAM components provided (1) a rapid, robust, and simple method to establish numerous fluidic inputs and outputs to various types of reaction chips; (2) highly parallel pumping and routing/valving capability; (3) methods to interface pumps and chip-to-liquid management systems; (4) means to construct a portable system; (5) reconfigurability/flexibility in system design; (6) means to interface to microscopes; and (7) compatibility with tested biological methods. It was found that LEGO Mindstorms motors, controllers, and software were robust, inexpensive, and an accessible choice as compared with corresponding custom-made actuators. MainSTREAM systems could operate continuously for weeks without leaks, contamination, or system failures. In conclusion, the MainSTREAM components described here meet many of the demands on components for constructing and using microfluidics systems.


Subject(s)
Cell Culture Techniques/instrumentation , Holistic Health , In Situ Hybridization/instrumentation , Microfluidic Analytical Techniques , Animals , Automation, Laboratory , Cost-Benefit Analysis , HeLa Cells , Humans , Miniaturization , Point-of-Care Systems , Reproducibility of Results
6.
Biomed Microdevices ; 14(2): 385-99, 2012 Apr.
Article in English | MEDLINE | ID: mdl-22160447

ABSTRACT

Utilizing microfluidics is a promising way for increasing the throughput and automation of cell biology research. We present a complete self-contained system for automated cell culture and experiments with real-time optical read-out. The system offers a high degree of user-friendliness, stability due to simple construction principles and compactness for integration with standard instruments. Furthermore, the self-contained system is highly portable enabling transfer between work stations such as laminar flow benches, incubators and microscopes. Accommodation of 24 individual inlet channels enables the system to perform parallel, programmable and multiconditional assays on a single chip. A modular approach provides system versatility and allows many different chips to be used dependent upon application. We validate the system's performance by demonstrating on-chip passive switching and mixing by peristaltically driven flows. Applicability for biological assays is demonstrated by on-chip cell culture including on-chip transfection and temporally programmable gene expression.


Subject(s)
Cell Culture Techniques/methods , Microfluidic Analytical Techniques/instrumentation , Microfluidic Analytical Techniques/methods , Microfluidics/instrumentation , Microscopy/methods , Equipment Design/methods , Gene Expression Regulation , HeLa Cells , Humans , Reproducibility of Results , Transfection
SELECTION OF CITATIONS
SEARCH DETAIL
...