Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Type of study
Language
Publication year range
1.
Int J Nephrol ; 2020: 7586437, 2020.
Article in English | MEDLINE | ID: mdl-33425390

ABSTRACT

BACKGROUND: To measure International Normalized Ratio (INR) in hemodialysis patients with tunneled dialysis catheters (TDCs), blood sampling is frequently obtained via the catheter at the start of the session. INR measurements via finger-prick point of care testing (POCT) and via blood sampling taken from the dialysis circuit are evaluated as alternatives. METHODS: In 14 hemodialysis patients with TDCs, treated with vitamin K antagonists (VKA), INR measurements via POCT were compared with plasma INR samples taken via the catheter at the start of dialysis and via the dialysis circuit after 30 and 60 minutes during 3 nonconsecutive dialysis sessions. RESULTS: Blood samples taken at the start of dialysis at the catheter site were frequently contaminated with heparin originating from the locking solution (unfractionated heparin concentration (UFH) >1.0 IU/ml in 13.2%). POCT INR at the start of dialysis was not different from plasma INR after 30 and 60 minutes (Wilcoxon test p=0.113, n = 37, and p=0.631, n = 36, respectively). Moreover, there was no difference between POCT INR at the start of dialysis and POCT INR after 30 and 60 minutes (Wilcoxon test p=0.797 and p = 0.801, respectively; n = 36). Passing and Bablok regression equation was used, y = 0.460 + 0.733x; n = 105. Treatment decisions based on these 2 methods showed a very good overall agreement (kappa = 0.810; 95% CI: 0.732-0.889; n = 105). CONCLUSIONS: Measuring plasma INR via the TDC at the start of dialysis should be abandoned. Measuring POCT INR via a finger prick at the start or even after 30 to 60 minutes is an alternative. The most elegant alternative is to take plasma INR samples via the dialysis circuit 30 minutes or later after the start of the dialysis.

2.
Ann Clin Biochem ; 52(Pt 2): 283-7, 2015 Mar.
Article in English | MEDLINE | ID: mdl-25205856

ABSTRACT

We report a case of an ethanol and massive gamma-butyrolactone (GBL) intoxication, the precursor of the recreational drug gamma-hydroxybutyric acid (GHB), resulting in life-threatening metabolic acidosis (pH 6.5) with a highly increased anion- and osmolal gap. Rapid analysis using gas chromatography revealed a GHB plasma concentration of 4400 mg/L, far above the upper limit concentration of 1000 mg/L found in adult fatalities attributed to GBL. Full recovery was established following supportive treatment including haemodialysis. This is the first report of a combined ethanol/GBL intoxication as a cause of high serum anion- and osmolal-gap metabolic acidosis.


Subject(s)
4-Butyrolactone/toxicity , Acidosis/etiology , Alcoholic Intoxication/physiopathology , Drug Overdose/physiopathology , Illicit Drugs/toxicity , 4-Butyrolactone/blood , Acidosis/metabolism , Acidosis/physiopathology , Acidosis/therapy , Alcoholic Intoxication/complications , Coma/etiology , Combined Modality Therapy , Cyanosis/etiology , Drug Overdose/complications , Emergency Medical Services , Humans , Illicit Drugs/blood , Male , Renal Dialysis , Severity of Illness Index , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...