Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
2.
Clin Chem ; 24(10): 1740-3, 1978 Oct.
Article in English | MEDLINE | ID: mdl-699281

ABSTRACT

We report a liquid-chromatographic procedure for determining free nicotinic acid and a metabolite, nicotinuric acid, in plasma and urine. Five-tenths milliliter of urine or deproteinized plasma is evaporated and the residue analyzed isocratically by reversed-phase ion-pair chromatography, with measurement of the eluted nicotinic acid and nicotinuric acid at 254 nm. Nicotinic acid, nicotinuric acid, and the internal standard (isonicotinic acid) have retention times of 7.8, 8.4, and 6.8 min, respectively, in plasma, and 12.3, 13.1, and 10.8 min in urine, because of double column length. Day-to-day reproducibilities (CV) for nicotinic acid and nicotinuric acid within 7.5% are attainable for the concentration ranges 0.1--20 mg/liter, equivalent to 0.81--162 micromol of nicotinic acid and 0.55--11 micromol of nicotinuric acid per liter for plasma; in urine for the range 0.5--100 mg/liter, equivalent to 4--810 micromol of nicotinic acid and 2.8--555 micromol of nicotinuric acid per liter. Metabolites of nicotinic acid such as nicotinamide, N-methylnicotinamide, 2-hydroxypyridine-5-carboxylic acid, and other structurally related substances do not interfere.


Subject(s)
Glycine/analogs & derivatives , Nicotinic Acids/analysis , Chromatography, Liquid/methods , Glycine/analysis , Glycine/blood , Glycine/urine , Humans , Nicotinic Acids/blood , Nicotinic Acids/urine
3.
Clin Chem ; 24(1): 50-3, 1978 Jan.
Article in English | MEDLINE | ID: mdl-618667

ABSTRACT

We report a procedure for determining nicotine and cotinine in plasma. Nicotine is extracted from 1 ml of plasma with diethyl ether, back extracted, and analyzed by gas-liquid chromatography with a nitrogen/phosphorus detector. Nicotine and its internal standard, modaline, had retention times of 1.9 and 2.9 min, respectively. Cotinine is then extracted from the same plasma with dichloromethane and similarly analyzed. Cotinine and its internal standard, lidocaine, had retention times of 3.8 and 4.9 min. Day-to-day reproducibilities (CV) within 14% for nicotine and within 6% for cotinine are attainable for the respective concentration ranges 1-100 microgram/liter and 1-200 microgram/liter. Nornicotine and related alkaloids do not interfere. The sensitivity was such that less than 0.1 microgram (0.62 nmol) of nicotine and 0.1 microgram (0.62 nmol) of nicotine and 0.1 microgram (0.57 nmol) of cotinine could be detected per liter.


Subject(s)
Cotinine/blood , Nicotine/blood , Pyrrolidinones/blood , Chromatography, Gas/methods , Humans , Smoking
SELECTION OF CITATIONS
SEARCH DETAIL
...