Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Acta Derm Venereol ; 100(6): adv00084, 2020 Mar 18.
Article in English | MEDLINE | ID: mdl-32128598

ABSTRACT

The treatment of choice for cutaneous squamous cell carcinoma is complete surgical excision. Incomplete excision of cutaneous squamous cell carcinoma has an increased risk of local recurrence, deep subclinical progression, and metastasis. This study aimed to investigate the proportion and risk factors of incomplete excised cutaneous squamous cell carcinoma. A systematic review of the literature was performed. Incomplete excision rates for cutaneous squamous cell carcinoma ranged from 0.4% to 35.7%. The pooled incomplete excision risk estimate was 13% (95% confidence interval 9-17%). Risk factors noted in more than one study for incomplete excision included tumor depth and size, type of operator, head and neck localization, and former incomplete excision. We found an overall incomplete excision rate of 13% for cutaneous squamous cell carcinoma. Risk factors should be taken into account in the management of cutaneous squamous cell carcinoma surgical treatment.


Subject(s)
Carcinoma, Squamous Cell/pathology , Carcinoma, Squamous Cell/surgery , Head and Neck Neoplasms/surgery , Skin Neoplasms/pathology , Skin Neoplasms/surgery , Clinical Competence , Humans , Neoplasm Invasiveness , Neoplasm, Residual , Reoperation , Risk Factors , Tumor Burden
2.
J Hand Surg Am ; 39(9): 1683-1691.e2, 2014 Sep.
Article in English | MEDLINE | ID: mdl-25091335

ABSTRACT

PURPOSE: To provide an overview of available clinical evaluation tests for scaphoid fractures and to compare their diagnostic accuracies. METHODS: PWe performed a systematic review of all studies assessing diagnostic characteristics of clinical evaluation in scaphoid fractures by searching MEDLINE, EMBASE, Cochrane, and CINAHL databases. Only studies on clinical testing prior to radiographic evaluation and with acceptable reference standard for occult fractures were included. Thirteen relevant articles were analyzed that described a total of 25 tests. Diagnostic characteristics of the tests were used to construct contingency tables. If possible, data were pooled and summary receiver operating characteristic curves were fitted. RESULTS: Anatomic snuff-box tenderness (ASB, 8 studies, 1,164 patients) and longitudinal thumb compression (LTC, 8 studies, 961 patients) had sufficient data for statistical analyses. Sensitivity for ASB ranged from 0.87 to 1.00; for LTC, 0.48 to 1.00. Specificity of ASB ranged from 0.03 to 0.98; for LTC, 0.22 to 0.97. Owing to considerable heterogeneity, pooled estimate points were not calculated. Other high-sensitivity tests were scaphoid tubercle tenderness, with sensitivity and specificity ranging from 0.82 to 1.00 and 0.17 to 0.57, respectively, and painful ulnar deviation, ranging from 0.67 to 1.00 and 0.17 to 0.60, respectively. Three studies showed that combining tests increased the specificity and post-test fracture probability while maintaining high sensitivity. Quality assessment showed high or unclear risk of bias and applicability concerns in reference standard and patient selection. Twelve study designs were prospective, and 1 was retrospective. CONCLUSIONS: Anatomical snuff box tenderness was the most sensitive clinical test. The low specificity of the clinical tests may result in a considerable number of overtreated patients. Combining tests improved the post-test fracture probability. This can be used to limit unnecessary immobilization, number of hospital visits, and use of imaging. The data presented herein may help to develop clinical prediction rules that could increase specificity without reducing sensitivity. TYPE OF STUDY/LEVEL OF EVIDENCE: Diagnostic II.


Subject(s)
Fractures, Bone/diagnosis , Scaphoid Bone/injuries , Diagnostic Imaging , Humans , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...