Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
J Cardiovasc Electrophysiol ; 33(5): 982-993, 2022 05.
Article in English | MEDLINE | ID: mdl-35233867

ABSTRACT

AIMS: The MicraTM transcatheter pacing system (TPS) (Medtronic) is the only leadless pacemaker that promotes atrioventricular (AV) synchrony via accelerometer-based atrial sensing. Data regarding the real-world experience with this novel system are scarce. We sought to characterize patients undergoing MicraTM -AV implants, describe percentage AV synchrony achieved, and analyze the causes for suboptimal AV synchrony. METHODS: In this retrospective cohort study, electronic medical records from 56 consecutive patients undergoing MicraTM -AV implants at the Mayo Clinic sites in Minnesota, Florida, and Arizona with a minimum follow-up of 3 months were reviewed. Demographic data, comorbidities, echocardiographic data, and clinical outcomes were compared among patients with and without atrial synchronous ventricular pacing (AsVP) ≥ 70%. RESULTS: Sixty-five percent of patients achieved AsVP ≥ 70%. Patients with adequate AsVP had smaller body mass indices, a lower proportion of congestive heart failure, and prior cardiac surgery. Echocardiographic parameters and procedural characteristics were similar across the two groups. Active device troubleshooting was associated with higher AsVP. The likely reasons for low AsVP were small A4-wave amplitude, high ventricular pacing burden, and inadequate device reprogramming. Importantly, in patients with low AsVP, subjective clinical worsening was not noted during follow-up. CONCLUSION: With the increasing popularity of leadless pacemakers, it is paramount for device implanting teams to be familiar with common predictors of AV synchrony and troubleshooting with MicraTM -AV devices.


Subject(s)
Pacemaker, Artificial , Cardiac Pacing, Artificial/adverse effects , Echocardiography , Heart Atria , Heart Ventricles , Humans , Pacemaker, Artificial/adverse effects , Retrospective Studies , Treatment Outcome
2.
J Cardiovasc Electrophysiol ; 30(9): 1602-1609, 2019 09.
Article in English | MEDLINE | ID: mdl-31190453

ABSTRACT

INTRODUCTION: Emerging medical technology has allowed for monitoring of heart rhythm abnormalities using smartphone compatible devices. The safety and utility of such devices have not been established in patients with cardiac implantable electronic devices (CIEDs). We sought to assess the safety and compatibility of the Food and Drug Administration-approved AliveCor Kardia device in patients with CIEDs. METHODS AND RESULTS: We prospectively recruited patients with CIED for a Kardia recording during their routine device interrogation. A recording was obtained in paced and nonpaced states. Adverse clinical events were noted at the time of recording. Electrograms (EGMs) from the cardiac device were obtained at the time of recording to assess for any electromagnetic interference (EMI) introduced by Kardia. Recordings were analyzed for quality and given a score of 3 (interpretable rhythm, no noise), 2 (interpretable rhythm, significant noise) or 1 (uninterpretable). A total of 251 patients were recruited (59% with a pacemaker and 41% with ICD). There were no adverse clinical events noted at the time of recording and no changes to CIED settings. Review of all EGMs revealed no EMI introduced by Kardia. Recordings were correctly interpreted in 90% of paced recordings (183 had a score of 3, 43 of 2, and 25 of 1) and 94.7% of nonpaced recordings (147 of 3, 15 of 2, and 9 of 1). CONCLUSION: The AliveCor Kardia device has an excellent safety profile when used in conjunction with most CIEDs. The quality of recordings was preserved in this population. The device, therefore, can be considered for heart rhythm monitoring in patients with CIEDs.


Subject(s)
Arrhythmias, Cardiac/therapy , Cardiac Pacing, Artificial , Defibrillators, Implantable , Electric Countershock/instrumentation , Electrophysiologic Techniques, Cardiac/instrumentation , Heart Rate , Mobile Applications , Pacemaker, Artificial , Remote Sensing Technology/instrumentation , Smartphone , Aged , Aged, 80 and over , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/physiopathology , Artifacts , Cardiac Pacing, Artificial/adverse effects , Defibrillators, Implantable/adverse effects , Electric Countershock/adverse effects , Electrophysiologic Techniques, Cardiac/adverse effects , Female , Humans , Male , Middle Aged , Pacemaker, Artificial/adverse effects , Predictive Value of Tests , Prospective Studies , Remote Sensing Technology/adverse effects , Reproducibility of Results , Risk Factors , Signal Processing, Computer-Assisted , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...