Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 49
Filter
1.
JAMA Cardiol ; 9(4): 346-356, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38416472

ABSTRACT

Importance: The effectiveness and safety of computed tomography (CT) and invasive coronary angiography (ICA) in different age groups is unknown. Objective: To determine the association of age with outcomes of CT and ICA in patients with stable chest pain. Design, Setting, and Participants: The assessor-blinded Diagnostic Imaging Strategies for Patients With Stable Chest Pain and Intermediate Risk of Coronary Artery Disease (DISCHARGE) randomized clinical trial was conducted between October 2015 and April 2019 in 26 European centers. Patients referred for ICA with stable chest pain and an intermediate probability of obstructive coronary artery disease were analyzed in an intention-to-treat analysis. Data were analyzed from July 2022 to January 2023. Interventions: Patients were randomly assigned to a CT-first strategy or a direct-to-ICA strategy. Main Outcomes and Measures: MACE (ie, cardiovascular death, nonfatal myocardial infarction, or stroke) and major procedure-related complications. The primary prespecified outcome of this secondary analysis of age was major adverse cardiovascular events (MACE) at a median follow-up of 3.5 years. Results: Among 3561 patients (mean [SD] age, 60.1 [10.1] years; 2002 female [56.2%]), 2360 (66.3%) were younger than 65 years, 982 (27.6%) were between ages 65 to 75 years, and 219 (6.1%) were older than 75 years. The primary outcome was MACE at a median (IQR) follow-up of 3.5 (2.9-4.2) years for 3523 patients (99%). Modeling age as a continuous variable, age, and randomization group were not associated with MACE (hazard ratio, 1.02; 95% CI, 0.98-1.07; P for interaction = .31). Age and randomization group were associated with major procedure-related complications (odds ratio, 1.15; 95% CI, 1.05-1.27; P for interaction = .005), which were lower in younger patients. Conclusions and Relevance: Age did not modify the effect of randomization group on the primary outcome of MACE but did modify the effect on major procedure-related complications. Results suggest that CT was associated with a lower risk of major procedure-related complications in younger patients. Trial Registration: ClinicalTrials.gov Identifier: NCT02400229.


Subject(s)
Coronary Artery Disease , Female , Humans , Middle Aged , Chest Pain/etiology , Chest Pain/diagnosis , Coronary Angiography/methods , Coronary Artery Disease/complications , Coronary Artery Disease/diagnostic imaging , Tomography, X-Ray Computed , Male , Aged
2.
Open Heart ; 10(2)2023 Dec 07.
Article in English | MEDLINE | ID: mdl-38065586

ABSTRACT

Smoking cessation is the most effective intervention to reduce mortality in patients with established atherosclerotic cardiovascular disease (ASCVD), with 'e-cigarettes' becoming an increasingly used intervention to achieve smoking cessation. The current review aims to summarise the current evidence base for their efficacy and safety in the ASCVD cohort. A search of the PUBMED and MEDLINE databases using the terms 'e-cigarette', 'cessation', 'safety' and 'efficacy' since 2012 yielded 706 results. Both observational and experimental studies were included, while those with an unavailable full text, non-English or duplicates were excluded, yielding 78 relevant articles, with 13 subsequent additional articles included from a search of reference lists, for a total of 91 included papers. E-cigarette vapour contains many known pro-atherosclerotic substances and has been demonstrated to potentiate traditional atherosclerotic mechanisms. While e-cigarettes may be more effective in promoting smoking cessation in the general population over a medium term (>6 months), when compared with nicotine replacement therapy (NRT), few studies specifically examined those with ASCVD, despite the latter having a higher baseline quit rate (52% vs 2%). Most studies compare e-cigarettes with NRT alone and do not include pharmacotherapy, which may be more effective in the ASCVD cohort. The single randomised controlled trial addressing the research question favoured traditional methods. Those that successfully quit smoking using e-cigarettes are more likely to continue to use the intervention at 1 year (90% vs 9%). Conflicting advice exists regarding the utilisation of e-cigarettes for smoking cessation. E-cigarettes may be inferior to standard care for smoking cessation in those with ASCVD, and their use is likely to promote the key drivers of the atherosclerotic process already active in this cohort.


Subject(s)
Electronic Nicotine Delivery Systems , Smoking Cessation , Humans , Smoking Cessation/methods , Nicotinic Agonists/therapeutic use , Tobacco Use Cessation Devices , Smoking
5.
Echo Res Pract ; 10(1): 3, 2023 Feb 22.
Article in English | MEDLINE | ID: mdl-36810286

ABSTRACT

BACKGROUND: Deformation imaging represents a method of measuring myocardial function, including global longitudinal strain (GLS), peak atrial longitudinal strain (PALS) and radial strain. This study aimed to assess subclinical improvements in left ventricular function in patients undergoing transcatheter aortic valve implantation (TAVI) by comparing GLS, PALS and radial strain pre and post procedure. METHODS: We conducted a single site prospective observational study of 25 patients undergoing TAVI, comparing baseline and post-TAVI echocardiograms. Individual participants were assessed for differences in GLS, PALS and radial strain in addition to changes in left ventricular ejection fraction (LVEF) (%). RESULTS: Our results revealed a significant improvement in GLS (mean change pre-post of 2.14% [95% CI 1.08, 3.20] p = 0.0003) with no significant change in LVEF (0.96% [95% CI - 2.30, 4.22], p = 0.55). There was a statistically significant improvement in radial strain pre and post TAVI (mean 9.68% [95% CI 3.10, 16.25] p = 0.0058). There was positive trend towards improvements in PALS pre and post TAVI (mean change of 2.30% [95% CI - 0.19, 4.80] p = 0.068). CONCLUSION: In patients undergoing TAVI, measuring GLS and radial strain provided statistically significant information regarding subclinical improvements in LV function, which may have prognostic implications. The incorporation of deformation imaging in addition to standard echocardiographic measurements may have an important role in guiding future management in patients undergoing TAVI and assessing response.

6.
Ir J Med Sci ; 192(3): 1085-1090, 2023 Jun.
Article in English | MEDLINE | ID: mdl-35809156

ABSTRACT

BACKGROUND: Despite the increased uptake of intravascular lithotripsy (IVL) for treating severely calcified coronary lesions, there is limited patient-level data examining the effect of IVL on quality of life, symptomatology, and outcomes beyond 30 days. We sought to assess demographics, procedural characteristics, outcomes, and impact of IVL on patient-reported angina after a minimum of 6 months follow-up. METHODS: A retrospective single-center study was conducted of patients treated with coronary IVL between January and October 2020. Baseline demographics were obtained from electronic patient records and SYNTAX scores were calculated from index coronary angiograms. Technical success and complications were assessed along with clinical outcomes, which included all-cause mortality, myocardial infarction (MI), target lesion revascularization (TLR), and MACE (composite of death, stroke, MI, and TLR). Canadian Cardiovascular Society (CCS) angina classification was assessed at virtual clinical follow-up. RESULTS: Forty-seven consecutive patients were included. At a mean follow-up of 306 ± 74 days, the mean CCS angina score was reduced by 53% post-IVL-assisted PCI (2.9 vs 1.4, p < 0.001). Technical and procedural success were high (94% and 92%, respectively). One patient (2%) met the pre-specified criteria for in-hospital MACE and 4 (9%) met pre-specified MACE at follow-up, including 2 deaths and 2 TLR. Procedural complications included coronary dissection (11%) and coronary perforation (6%) and were managed either conservatively or with PCI. CONCLUSIONS: Coronary IVL is a safe and effective adjunctive therapy for treating heavily calcified coronary lesions. This cohort shows high procedural success and a significant reduction in CCS angina at follow-up.


Subject(s)
Coronary Artery Disease , Lithotripsy , Myocardial Infarction , Percutaneous Coronary Intervention , Vascular Calcification , Humans , Coronary Artery Disease/surgery , Percutaneous Coronary Intervention/adverse effects , Retrospective Studies , Quality of Life , Treatment Outcome , Vascular Calcification/diagnostic imaging , Vascular Calcification/therapy , Vascular Calcification/etiology , Canada , Lithotripsy/adverse effects
8.
N Engl J Med ; 386(17): 1591-1602, 2022 04 28.
Article in English | MEDLINE | ID: mdl-35240010

ABSTRACT

BACKGROUND: In the diagnosis of obstructive coronary artery disease (CAD), computed tomography (CT) is an accurate, noninvasive alternative to invasive coronary angiography (ICA). However, the comparative effectiveness of CT and ICA in the management of CAD to reduce the frequency of major adverse cardiovascular events is uncertain. METHODS: We conducted a pragmatic, randomized trial comparing CT with ICA as initial diagnostic imaging strategies for guiding the treatment of patients with stable chest pain who had an intermediate pretest probability of obstructive CAD and were referred for ICA at one of 26 European centers. The primary outcome was major adverse cardiovascular events (cardiovascular death, nonfatal myocardial infarction, or nonfatal stroke) over 3.5 years. Key secondary outcomes were procedure-related complications and angina pectoris. RESULTS: Among 3561 patients (56.2% of whom were women), follow-up was complete for 3523 (98.9%). Major adverse cardiovascular events occurred in 38 of 1808 patients (2.1%) in the CT group and in 52 of 1753 (3.0%) in the ICA group (hazard ratio, 0.70; 95% confidence interval [CI], 0.46 to 1.07; P = 0.10). Major procedure-related complications occurred in 9 patients (0.5%) in the CT group and in 33 (1.9%) in the ICA group (hazard ratio, 0.26; 95% CI, 0.13 to 0.55). Angina during the final 4 weeks of follow-up was reported in 8.8% of the patients in the CT group and in 7.5% of those in the ICA group (odds ratio, 1.17; 95% CI, 0.92 to 1.48). CONCLUSIONS: Among patients referred for ICA because of stable chest pain and intermediate pretest probability of CAD, the risk of major adverse cardiovascular events was similar in the CT group and the ICA group. The frequency of major procedure-related complications was lower with an initial CT strategy. (Funded by the European Union Seventh Framework Program and others; DISCHARGE ClinicalTrials.gov number, NCT02400229.).


Subject(s)
Coronary Angiography , Coronary Artery Disease , Tomography, X-Ray Computed , Angina Pectoris/diagnostic imaging , Angina Pectoris/etiology , Chest Pain/diagnostic imaging , Chest Pain/etiology , Coronary Angiography/adverse effects , Coronary Artery Disease/complications , Coronary Artery Disease/diagnostic imaging , Female , Humans , Male , Tomography, X-Ray Computed/adverse effects
9.
Future Cardiol ; 18(4): 275-283, 2022 04.
Article in English | MEDLINE | ID: mdl-34875868

ABSTRACT

Transcatheter aortic valve implantation and implantation of other transcatheter heart valves, generally requires insertion of a temporary venous pacemaker. Implantation of a temporary venous pacemaker adds complexity, time and risk to the procedure. Guidewire modification to allow pacing is increasingly popular, however it requires technical expertise and provides unipolar pacing resulting in high thresholds and potential capture loss. The Wattson temporary pacing guidewire is a novel device which offers guidewire support for valve delivery and concomitant bipolar pacing. It may offer a safe and effective solution to guidewire pacing for transcatheter aortic valve implantation and other transcatheter heart valve implantations. Herein, we review the literature surrounding left ventricular guidewire pacing along with the features and clinical data of the Wattson wire.


Replacing a heart valve, such as in transcatheter aortic valve implantation, requires the use of a pacemaker. This is often inserted through the veins into the opposite side of the heart to the valve being replaced. However, this method adds risk, time and complexity. New technologies have been developed to simplify this process, by using one wire in only one side of the heart to stimulate the heart muscle and support the valve replacement. The Wattson wire is a new device which acts this way and promises to make the transcatheter aortic valve implantation procedure safer and more efficient.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Pacemaker, Artificial , Transcatheter Aortic Valve Replacement , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Cardiac Pacing, Artificial , Humans , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome
10.
JACC Cardiovasc Interv ; 14(5): 489-500, 2021 03 08.
Article in English | MEDLINE | ID: mdl-33663778

ABSTRACT

Growing clinical data support the use of transcatheter therapies for significant mitral valve disease. Currently, edge-to-edge repair is the transcatheter treatment of choice, but many anatomies are not suitable. Transcatheter mitral valve replacement offers several potential advantages over transcatheter repair, most notably a greater and more sustained reduction in mitral regurgitation post-implantation, but also potential disadvantages. To enable the successful treatment of mitral valve disease in a wide range of patients and anatomies, we require an armory of transcatheter devices, including transcatheter mitral valve replacement systems.


Subject(s)
Heart Valve Prosthesis Implantation , Mitral Valve Annuloplasty , Mitral Valve Insufficiency , Cardiac Catheterization/adverse effects , Heart Valve Prosthesis Implantation/adverse effects , Humans , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Annuloplasty/adverse effects , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Treatment Outcome
11.
JACC Cardiovasc Interv ; 14(5): 501-511, 2021 03 08.
Article in English | MEDLINE | ID: mdl-33582084

ABSTRACT

OBJECTIVES: The purpose of this observational first-in-human experience was to investigate the feasibility and safety of the EVOQUE tricuspid valve replacement system and its impact on short-term clinical outcomes. BACKGROUND: Transcatheter tricuspid intervention is a promising option for selected patients with severe tricuspid regurgitation (TR). Although transcatheter leaflet repair is an option for some, transcatheter tricuspid valve replacement (TTVR) may be applicable to a broader population. METHODS: Twenty-five patients with severe TR underwent EVOQUE TTVR in a compassionate-use experience. The primary outcome was technical success, with NYHA (NYHA) functional class, TR grade, and major adverse cardiac and cerebrovascular events assessed at 30-day follow-up. RESULTS: All patients (mean age 76 ± 3 years, 88% women) were at high surgical risk (mean Society of Thoracic Surgeons risk score 9.1 ± 2.3%), with 96% in NYHA functional class III or IV. TR etiology was predominantly functional, with mean tricuspid annular diameter of 44.8 ± 7.8 mm and mean tricuspid annular plane systolic excursion of 16 ± 2 mm. Technical success was 92%, with no intraprocedural mortality or conversion to surgery. At 30-day follow-up, mortality was 0%, 76% of patients were in NYHA functional class I or II, and TR grade was ≤2+ in 96%. Major bleeding occurred in 3 patients (12%), 2 patients (8%) required pacemaker implantation, and 1 patient (4%) required dialysis. CONCLUSIONS: This first-in-human experience evaluating EVOQUE TTVR demonstrated high technical success, acceptable safety, and significant clinical improvement. Larger prospective studies are needed to confirm durability and safety and the impact on long-term clinical outcomes.


Subject(s)
Heart Valve Prosthesis Implantation , Tricuspid Valve Insufficiency , Aged , Cardiac Catheterization/adverse effects , Female , Heart Valve Prosthesis Implantation/adverse effects , Humans , Male , Time Factors , Treatment Outcome , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/surgery , Tricuspid Valve Insufficiency/diagnostic imaging , Tricuspid Valve Insufficiency/surgery
12.
JACC Cardiovasc Interv ; 13(20): 2344-2357, 2020 10 26.
Article in English | MEDLINE | ID: mdl-33092709

ABSTRACT

OBJECTIVES: The authors report the CLASP (Edwards PASCAL Transcatheter Mitral Valve Repair System Study) expanded experience, 1-year outcomes, and analysis by functional mitral regurgitation (FMR) and degenerative mitral regurgitation (DMR). BACKGROUND: The 30-day results from the CLASP study of the PASCAL transcatheter valve repair system for clinically significant mitral regurgitation (MR) have been previously reported. METHODS: Eligible patients had symptomatic MR ≥3+, were receiving optimal medical therapy, and were deemed candidates for transcatheter mitral repair by the local heart team. Primary endpoints included procedural success, clinical success, and major adverse event rate at 30 days. Follow-up was continued to 1 year. RESULTS: One hundred nine patients were treated (67% FMR, 33% DMR); the mean age was 75.5 years, and 57% were in New York Heart Association functional class III or IV. At 30 days, there was 1 cardiovascular death (0.9%), MR ≤1+ was achieved in 80% of patients (77% FMR, 86% DMR) and MR ≤2+ in 96% (96% FMR, 97% DMR), 88% of patients were in New York Heart Association functional class I or II, 6-min walk distance had improved by 28 m, and Kansas City Cardiomyopathy Questionnaire score had improved by 16 points (p < 0.001 for all). At 1 year, Kaplan-Meier survival was 92% (89% FMR 96% DMR) with 88% freedom from heart failure hospitalization (80% FMR, 100% DMR), MR was ≤1+ in 82% of patients (79% FMR, 86% DMR) and ≤2+ in 100% of patients, 88% of patients were in New York Heart Association functional class I or II, and Kansas City Cardiomyopathy Questionnaire score had improved by 14 points (p < 0.001 for all). CONCLUSIONS: The PASCAL transcatheter valve repair system demonstrated a low complication rate and high survival, with robust sustained MR reduction accompanied by significant improvements in functional status and quality of life at 1 year. (The CLASP Study Edwards PASCAL Transcatheter Mitral Valve Repair System Study [CLASP]; NCT03170349).


Subject(s)
Cardiac Surgical Procedures , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Aged , Humans , Mitral Valve/surgery , Mitral Valve Insufficiency/surgery , Quality of Life , Treatment Outcome
13.
JACC Cardiovasc Interv ; 13(20): 2418-2426, 2020 10 26.
Article in English | MEDLINE | ID: mdl-33092713

ABSTRACT

OBJECTIVES: The aim of this study was to examine the initial experience with a novel transseptal transcatheter mitral valve replacement (TMVR) system. BACKGROUND: Transseptal TMVR may offer a less invasive option than surgery for mitral regurgitation (MR) with greater efficacy and fewer anatomic limitations than transcatheter repair. METHODS: Patients were treated with the EVOQUE TMVR system from September 2018 to October 2019. Key inclusion criteria were moderate or greater MR, New York Heart Association functional class ≥II, and high or prohibitive surgical risk. The primary outcome was technical success, defined by Mitral Valve Academic Research Consortium criteria. RESULTS: Fourteen patients were treated, all with at least moderate to severe MR. The median age was 84 years, and the median Society of Thoracic Surgeons score was 4.6%. MR was degenerative in 4 (28.6%), functional in 3 (21.4%), and mixed in 7 (50%). Technical success was achieved in 13 patients (92.9%), and 1 patient was converted to surgery. At 30 days there was 1 noncardiovascular mortality (7.1%), 2 strokes (14.3%), no myocardial infarctions, and no rehospitalizations. Two patients (14.3%) underwent paravalvular leak closure. One patient (7.1%) underwent alcohol septal ablation for left ventricular outflow tract obstruction. Including the 2 patients with paravalvular leak closure, MR was mild or less in all implanted patients at 30 days, with no MR in 10 (83.3%). Mean mitral gradient was 5.8 mm Hg (median). New York Heart Association functional class improved to ≤II in 9 patients (81.8%). CONCLUSIONS: This first-in-human experience has demonstrated the feasibility of the transseptal EVOQUE TMVR system. Further clinical studies are required to establish safety and clinical outcomes.


Subject(s)
Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Mitral Valve Insufficiency , Mitral Valve , Aged, 80 and over , Humans , Mitral Valve/surgery , Mitral Valve Insufficiency/surgery , Treatment Outcome
16.
Health Qual Life Outcomes ; 18(1): 140, 2020 05 14.
Article in English | MEDLINE | ID: mdl-32410687

ABSTRACT

BACKGROUND: Health-related quality of life (HRQoL) is impaired in patients with stable angina but patients often present with other forms of chest pain. The aim of this study was to compare the pre-diagnostic HRQoL in patients with suspected coronary artery disease (CAD) according to angina type, gender, and presence of obstructive CAD. METHODS: From the pilot study for the European DISCHARGE trial, we analysed data from 24 sites including 1263 patients (45.9% women, 61.1 ± 11.3 years) who were clinically referred for invasive coronary angiography (ICA; 617 patients) or coronary computed tomography angiography (CTA; 646 patients). Prior to the procedures, patients completed HRQoL questionnaires: the Short Form (SF)-12v2, the EuroQoL (EQ-5D-3 L) and the Hospital Anxiety and Depression Scale. RESULTS: Fifty-five percent of ICA and 35% of CTA patients had typical angina, 23 and 33% had atypical angina, 18 and 28% had non-anginal chest discomfort and 5 and 5% had other chest discomfort, respectively. Patients with typical angina had the poorest physical functioning compared to the other angina groups (SF-12 physical component score; 41.2 ± 8.8, 43.3 ± 9.1, 46.2 ± 9.0, 46.4 ± 11.4, respectively, all age and gender-adjusted p < 0.01), and highest anxiety levels (8.3 ± 4.1, 7.5 ± 4.1, 6.5 ± 4.0, 4.7 ± 4.5, respectively, all adjusted p < 0.01). On all other measures, patients with typical or atypical angina had lower HRQoL compared to the two other groups (all adjusted p < 0.05). HRQoL did not differ between patients with and without obstructive CAD while women had worse HRQoL compared with men, irrespective of age and angina type. CONCLUSIONS: Prior to a diagnostic procedure for stable chest pain, HRQoL is associated with chest pain characteristics, but not with obstructive CAD, and is significantly lower in women. TRIAL REGISTRATION: Clinicaltrials.gov, NCT02400229.


Subject(s)
Angina Pectoris/physiopathology , Coronary Artery Disease/physiopathology , Quality of Life , Aged , Angina Pectoris/classification , Angina Pectoris/diagnosis , Coronary Artery Disease/diagnosis , Female , Humans , Male , Middle Aged , Pilot Projects , Sex Distribution , Surveys and Questionnaires
18.
Catheter Cardiovasc Interv ; 96(4): 981-986, 2020 10 01.
Article in English | MEDLINE | ID: mdl-32118351

ABSTRACT

BACKGROUND: Valve-in-valve (VIV) treatment with transcatheter aortic valve replacement (TAVR) is a viable option for patients with failing aortic bioprosthetic valves. Optimal management of those with concomitant mitral regurgitation (MR) remains undetermined. Therefore, we sought to assess the implications of concomitant MR in patients undergoing VIV-TAVR. METHODS AND RESULTS: The PARTNER 2 VIV registry enrolled patients with degenerated surgical aortic bioprosthesis at high risk for reoperation. Patients with core-laboratory echocardiographic assessment of MR were analyzed; severe MR was excluded. We compared patients with ≤mild MR versus moderate MR and assessed changes in MR severity and clinical outcomes. A total of 339 patients (89 initial registry, 250 continued access) underwent VIV procedures; mean age 79.0 ± 10.2 years, mean Society of Thoracic Surgeon score 8.9 ± 4.5%. At baseline, 228/339 (67.3%) had ≤mild MR and 111/339 (32.7%) had moderate MR. In paired analysis, there was significant improvement in ≥moderate MR from baseline to 30 days (32.6% vs. 14.5%, p < .0001 [n = 304]), and no significant change between 30 days and 1 year (13.4% vs. 12.1%, p = .56 [n = 224]) or 1 year and 2 years (11.0% vs. 10.4%, p = .81 [n = 182]). There was no difference in death or stroke between ≤mild MR and moderate MR at 30 days (4.0% vs. 7.2%, p = .20), 1 year (15.5% vs. 15.3%, p = .98) or 2 years (26.5% vs. 23.5%, p = .67). CONCLUSION: Moderate concomitant MR tends to improve with VIV-TAVR, and was not a predictor of long-term adverse outcomes in this cohort. In selected patients undergoing VIV-TAVR, it may be appropriate to conservatively manage concomitant MR. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov NCT# 03225001.


Subject(s)
Aortic Valve Insufficiency/surgery , Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Bioprosthesis , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis , Mitral Valve Insufficiency/physiopathology , Mitral Valve/physiopathology , Prosthesis Failure , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/mortality , Aortic Valve Insufficiency/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/physiopathology , Female , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/mortality , Humans , Male , Mitral Valve/diagnostic imaging , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/mortality , Recovery of Function , Registries , Risk Assessment , Risk Factors , Severity of Illness Index , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome
19.
JACC Cardiovasc Interv ; 13(6): 667-678, 2020 03 23.
Article in English | MEDLINE | ID: mdl-32113932

ABSTRACT

OBJECTIVES: The aim of this study was to examine the effect of different transcatheter heart valves (THVs) on valve leaflet displacement when deployed within bioprosthetic surgical valves and, thereby, risk for coronary obstruction. BACKGROUND: Coronary obstruction is a potentially devastating complication during valve-in-valve (ViV) transcatheter aortic valve replacement. Strategies such as provisional stenting and intentional bioprosthetic valve leaflet laceration have been developed to mitigate this risk. Alternatively, the use of a THV that retracts the bioprosthetic leaflet away from the coronary ostium may prevent coronary obstruction. METHODS: A 25-mm J-Valve, a 26-mm Evolut Pro, and a 23-mm JenaValve were implanted into both a 25-mm Trifecta surgical valve and a 25-mm Mitroflow surgical valve. A 23-mm and a 26-mm SAPIEN 3 were deployed into the Trifecta and Mitroflow, respectively. Displacement of the surgical valve leaflets (retraction vs. expansion) was measured with implantation of each THV by measuring displacement angle and maximal displacement distance. RESULTS: Within both the Trifecta and Mitroflow valves, implantation of the J-Valve and JenaValve resulted in retraction of the surgical valve leaflets, and placement of the Evolut Pro and SAPIEN 3 resulted in tubular expansion of the surgical valve leaflets. There were significant differences in displacement angles and distances between both the J-Valve and JenaValve and the SAPIEN 3 and Evolut Pro (p < 0.0001). CONCLUSIONS: ViV implantation with new-generation THVs that directly interact with bioprosthetic valve leaflets results in surgical valve leaflet retraction. This might mitigate the risk for coronary obstruction in selected cases of ViV transcatheter aortic valve replacement and also facilitate coronary reaccess after ViV TAVR.


Subject(s)
Bioprosthesis , Coronary Stenosis/prevention & control , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis , Prosthesis Failure , Transcatheter Aortic Valve Replacement/instrumentation , Coronary Stenosis/etiology , Equipment Failure Analysis , Heart Valve Prosthesis Implantation/adverse effects , Humans , Materials Testing , Prosthesis Design , Risk Assessment , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effects
20.
Catheter Cardiovasc Interv ; 96(4): 968-971, 2020 10 01.
Article in English | MEDLINE | ID: mdl-32150334

ABSTRACT

OBJECTIVES: To assess the safety and efficacy of the Wattson temporary pacing guidewire. BACKGROUND: Transcatheter aortic valve replacement (TAVR) requires a guidewire for device delivery and generally requires temporary pacing wire for burst and back-up pacing. The Wattson wire provides concomitant support and bipolar pacing without the need to place a temporary venous pacemaker (TVP). METHODS: This was a single-center nonrandomized prospective clinical trial enrolling 20 patients. The primary endpoint was defined as successful rapid pacing and transcatheter heart valve (THV) delivery with no loss of capture. Safety, qualitative and quantitative secondary outcomes were also analyzed. RESULTS: Mean age was 77.4 ± 9.0 years. Mean Society of Thoracic Surgery (STS) score was 3.0 ± 1.5%. All patients received a balloon-expandable valve via a transfemoral approach. All patients met the primary end-point. One patient (5%) had balloon predilatation and six patients (30%) had postdilatation, all using the wire. Mean pacing threshold was 2.2 ± 1.2 mA that was evaluated prior to placing an insulating catheter over the wire. One patient required TVP placement and subsequent permanent pacemaker implantation due to complete heart block post THV deployment. There were no incidences of cardiac perforation or tamponade. One patient required valve reintervention, which was not related to the device. CONCLUSIONS: The Wattson wire offered predictable guidewire support with concomitant reliable bipolar pacing at low thresholds to allow safe THV delivery in this patient cohort. It has the potential to make TAVR a safer and more efficient procedure.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Cardiac Catheters , Cardiac Pacing, Artificial , Pacemaker, Artificial , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Equipment Design , Female , Humans , Male , Prospective Studies , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...