Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
J Thorac Cardiovasc Surg ; 164(3): 867-876.e5, 2022 09.
Article in English | MEDLINE | ID: mdl-33168163

ABSTRACT

PURPOSE: Degenerative mitral regurgitation repair using a measured algorithm could increase the precision and reproducibility of repair outcomes. METHODS: Direct and echocardiographic measurements guide the repair to achieve a coaptation length of 5 to 10 mm and minimize the risk of systolic anterior motion. Leaflet reconstruction restored the normal 2 to 1 ratio of anterior to posterior leaflet length without residual prolapse or restriction. The choice of ring size was based on anterior leaflet length, the distance from the leaflet coaptation point to the septum, and the anterior-posterior ring dimension. Freedom from reoperation and mitral regurgitation recurrence were based on multistate models. RESULTS: One thousand fifty-one patients had mitral surgery and 1026 (97.6%) were repaired. A2 length was 27.2 ± 4.5 mm; and the reconstructed posterior leaflet was 13.9 ± 2.3 mm. Median ring size was 34 mm and strongly correlated to A2 length (R = 0.76; P < .001). The coaptation length at P2 after repair was 6.4 ± 1.7 mm and 87% of measurements were between 5 and 10 mm. Results at predischarge and 10 years, respectively, included mild regurgitation (7.5% and 26.1%), moderate (0.7% and 15.6%), moderate to severe (0% and 1.4%), and severe (0% and 0%), with mean mitral gradient values 3.5 ± 1.5 and 2.9 ± 1.2 mm Hg, respectively. Systolic anterior motion at discharge and last follow-up were 0.2% and 1.1%, respectively. Ten-year freedom from mitral valve reoperation was 99.7%. CONCLUSIONS: A simple, reproducible, measured algorithm for degenerative mitral valve repair provides excellent early and late results and is a useful adjunct to established surgical techniques.


Subject(s)
Mitral Valve Insufficiency , Mitral Valve Prolapse , Algorithms , Humans , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Mitral Valve Prolapse/surgery , Reoperation , Reproducibility of Results , Treatment Outcome
2.
Anesthesiol Clin ; 35(3): 539-553, 2017 Sep.
Article in English | MEDLINE | ID: mdl-28784225

ABSTRACT

As solid organ transplantation increases and patient survival improves, it will become more common for these patients to present for nontransplant surgery. Recipients may present with medical problems unique to the transplant, and important considerations are necessary to keep the transplanted organ functioning. A comprehensive preoperative examination with specific focus on graft functioning is required, and the anesthesiologist needs pay close attention to considerations of immunosuppressive regimens, blood product administration, and the risk benefits of invasive monitoring in these immunosuppressed patients. This article reviews the posttransplant physiology and anesthetic considerations for patients after solid organ transplantation.


Subject(s)
Anesthesia/methods , Transplant Recipients , Anesthesia, Conduction/methods , Blood Coagulation , Humans , Immunosuppressive Agents , Intraoperative Care , Organ Transplantation , Risk Assessment
3.
J Cardiothorac Vasc Anesth ; 28(3): 635-9, 2014 Jun.
Article in English | MEDLINE | ID: mdl-24447499

ABSTRACT

OBJECTIVE: To characterize contemporary practice patterns in the use of transesophageal echocardiography during adult liver transplantation and to identify factors preventing more frequent use. DESIGN: Online questionnaire. SETTING: Liver transplantation centers in the United States performing 12 or more adult liver transplants in 2011. PARTICIPANTS: One representative from each qualifying center: The transplant anesthesiology director, a transplant anesthesiologist personally known to the authors, or the department of anesthesiology chair. INTERVENTIONS: Three e-mail attempts were made to solicit participation in the study between June and August 2012. MEASUREMENTS AND MAIN RESULTS: Of the 97 institutions identified, an anesthesiologist from each of 79 (81.4%) centers completed the questionnaire; 38.0% of centers reported routine use and 57.0% for special circumstances or rescue situations, yielding an overall use rate of 94.9%. This distribution was consistent regardless of operative volume, practice size, or academic affiliation. The sole factor predictive of routine transesophageal echocardiography use was an overlap between an institution's cardiac and transplant anesthesiology teams. In practices not routinely employing the technology, the most compelling reason was a sense that it was not necessary. Although 69.9% of transplant anesthesiologists reportedly were proficient in echocardiography, inadequate anesthesiologist training was also a strongly cited hindrance. CONCLUSIONS: Transesophageal echocardiography during adult liver transplantation in the United States has become widely prevalent, with notable growth in its use as a routine diagnostic and monitoring modality. Almost all institutions now use the technology at least occasionally, with the participation of cardiac anesthesiologists being predictive of a center's routine use.


Subject(s)
Echocardiography, Transesophageal/statistics & numerical data , Liver Transplantation/statistics & numerical data , Attitude of Health Personnel , Health Care Surveys , Humans , Internet , Liver Transplantation/methods , Monitoring, Intraoperative , Perioperative Care , Surveys and Questionnaires , Treatment Outcome , United States
SELECTION OF CITATIONS
SEARCH DETAIL
...