1.
J Foot Ankle Surg ; 62(5): 785-787, 2023.
Article in English | MEDLINE | ID: mdl-37062505

ABSTRACT

Consensus has not been reached for the optimal postoperative care after high ankle sprain and syndesmotic fixation. A potential drawback of earlier return to activity is greater instability of the ankle and fixation failure. The controlled ankle motion (CAM) boot has been an effective implementation to stabilize the leg and may aid in safe early weightbearing status. However, there is insufficient study of its effect on motion in the syndesmosis following injury. Hence, the aim of this cadaveric study was to determine the stability of the ankle with a CAM boot at 3 levels of injury: syndesmosis ligaments intact (no injury), syndesmosis ligaments cut, and syndesmosis and fibula cut. Six cadaveric legs were subjected to each level of injury and axially loaded at 1 Hz between 100 N-1.5 times body weight for 50 seconds, and axial force, axial displacement, and optical tracking data were recorded. It was found that the ankle, when protected by the CAM boot, maintained syndesmosis motion with no difference (p > .05) from the uninjured state, regardless of syndesmotic ligament and fibular injury. This finding was consistent across anterior-posterior, medial-lateral, and superior-inferior axes. Overall, our study may suggest that early weightbearing with a CAM boot maintains a physiologically range of motion in the syndesmosis.


Subject(s)
Ankle , Joint Instability , Humans , Joint Instability/prevention & control , Ankle Joint/surgery , Ankle Joint/physiology , Fibula/surgery , Weight-Bearing/physiology , Cadaver
3.
Eur J Orthop Surg Traumatol ; 33(1): 67-72, 2023 Jan.
Article in English | MEDLINE | ID: mdl-34739600

ABSTRACT

PURPOSE: Augmentation strategies for surgical fixation of proximal humerus fractures (PHF) are available to address their relatively high failure rate. The purpose of this study was to compare two medial-buttress augmentation strategies for PHF fixation. METHODS: A two-part PHF model with loss of medial buttress was created in 16 synthetic bones. The PHFs were fixed with locking plates and either calcium phosphate cement (CPC) or fibula strut (FS) augmentation. After cadaveric validations, the fixation constructs were subjected to nondestructive axial compression tests, followed by a cyclic test. Construct stiffness and angular displacement of the humerus head were recorded. RESULTS: Humeral head angular displacement was statistically greater in the CPC group than in the FS group at the applied force of 300 N and higher (p < 0.05). Axial stiffness was statistically greater in the FS fixation group than in the CPC group at initial and final phases of cyclic loading protocol (p < 0.05). CONCLUSIONS: In an osteoporotic cadaveric model of a 2-part PHF with loss of a medial buttress, locked plate constructs augmented with FS have a higher resistance to varus collapse compared to those augmented with CPC.


Subject(s)
Humeral Fractures , Shoulder Fractures , Humans , Biomechanical Phenomena , Bone Cements/therapeutic use , Bone Plates , Cadaver , Calcium Phosphates/therapeutic use , Fibula/surgery , Fracture Fixation, Internal/methods , Shoulder Fractures/surgery
4.
Sensors (Basel) ; 22(16)2022 Aug 19.
Article in English | MEDLINE | ID: mdl-36016004

ABSTRACT

There is an unmet need for improved, clinically relevant methods to longitudinally quantify bone healing during fracture care. Here we develop a smart bone plate to wirelessly monitor healing utilizing electrical impedance spectroscopy (EIS) to provide real-time data on tissue composition within the fracture callus. To validate our technology, we created a 1-mm rabbit tibial defect and fixed the bone with a standard veterinary plate modified with a custom-designed housing that included two impedance sensors capable of wireless transmission. Impedance magnitude and phase measurements were transmitted every 48 h for up to 10 weeks. Bone healing was assessed by X-ray, µCT, and histology. Our results indicated the sensors successfully incorporated into the fracture callus and did not impede repair. Electrical impedance, resistance, and reactance increased steadily from weeks 3 to 7-corresponding to the transition from hematoma to cartilage to bone within the fracture gap-then plateaued as the bone began to consolidate. These three electrical readings significantly correlated with traditional measurements of bone healing and successfully distinguished between union and not-healed fractures, with the strongest relationship found with impedance magnitude. These results suggest that our EIS smart bone plate can provide continuous and highly sensitive quantitative tissue measurements throughout the course of fracture healing to better guide personalized clinical care.


Subject(s)
Fracture Healing , Fractures, Bone , Animals , Bone Plates , Bony Callus/diagnostic imaging , Bony Callus/pathology , Dielectric Spectroscopy/methods , Fractures, Bone/diagnostic imaging , Rabbits
6.
J Foot Ankle Surg ; 59(1): 86-90, 2020.
Article in English | MEDLINE | ID: mdl-31882153

ABSTRACT

Currently, Achilles tendon rupture repair is surgically addressed with an open or minimally invasive approach using a heavy, nonabsorbable suture in a locking stitch configuration. However, these sutures have low stiffness and a propensity to stretch, which can result in gapping at the repair site. Our study compares a new multifilament stainless steel cable-crimp repair method to a standard Krackow repair using multistrand, ultra-high molecular weight polyethylene polyester sutures. Eight matched pairs of cadavers were randomly assigned for Achilles tendon repair using either Krackow technique with polyethylene polyester sutures or the multifilament stainless steel cable-crimp technique. Each repair was cyclically loaded from 10 to 50 N for 100 loading cycles, followed by a linear increase in load until complete failure of the repair. During cyclic loading, 4 of the 8 Krackow polyethylene polyester suture repairs failed, whereas none of the multifilament stainless steel cable crimp repairs failed. Load to failure was greater for the multifilament stainless steel cable crimp repairs (321.03 ± 118.71 N) than for the Krackow polyethylene polyester suture repairs (132.47 ± 103.39 N, p = .0078). The ultimate tensile strength of the multifilament stainless steel cable crimp repairs was also greater than that of the Krackow polyethylene polyester suture repairs (485.69 ± 47.93 N vs 378.71 ± 107.23 N, respectively, p = .12). The mode of failure was by suture breakage at the crimp for all cable-crimp repairs and by suture breakage at the knot, within the tendon, or suture pullout for the polyethylene polyester suture repairs. The multifilament stainless steel cable crimp construct may be a better alternative for Achilles tendon rupture repairs.


Subject(s)
Achilles Tendon/surgery , Polyethylenes , Stainless Steel , Suture Techniques , Sutures , Tendon Injuries/surgery , Achilles Tendon/injuries , Aged , Aged, 80 and over , Female , Humans , Male , Materials Testing , Middle Aged , Tensile Strength
7.
Hand (N Y) ; 15(6): 842-849, 2020 11.
Article in English | MEDLINE | ID: mdl-30813805

ABSTRACT

Background: The aim of this study was to quantify the stabilizing properties of a 3-dimensional (3D)-printed short-arm cast and compare those properties with traditional fiberglass casts in a cadaveric subacute distal radius fracture model. Methods: A cadaveric subacute fracture model was created in 8 pairs of forearms. The specimens were equally allocated to a fiberglass cast or 3D-printed cast group. All specimens were subjected to 3 biomechanical testing modalities simulating daily life use: flexion and extension of digits, pronation and supination of the hand, and 3-point bending. Between each loading modality, radiological evaluation of the specimens was performed to evaluate possible interval displacement. Interfragmentary motion was quantified using a 3D motion-tracking system. Results: Radiographic assessment did not reveal statistically significant differences in radiographic parameters between the 2 groups before and after biomechanical testing. A statistically significant difference in interfragmentary motion was calculated with the 3-point bending test, with a mean difference of 0.44 (±0.48) mm of motion. Conclusions: A statistically significant difference in interfragmentary motion between the 2 casting groups was only identified in 3-point bending. However, the clinical relevance of this motion remains unclear as the absolute motion is less than 1 mm. The results of this study show noninferiority of the 3D-printed casts compared with the traditional fiberglass casts in immobilizing a subacute distal radius fracture model. These results support the execution of a prospective randomized clinical trial comparing both casting techniques.


Subject(s)
Casts, Surgical/classification , Printing, Three-Dimensional , Radius Fractures/therapy , Aged , Biomechanical Phenomena , Cadaver , Female , Forearm Injuries/physiopathology , Forearm Injuries/therapy , Humans , Male , Middle Aged , Prospective Studies , Radius Fractures/physiopathology , Range of Motion, Articular
8.
J Orthop Trauma ; 34(1): 55-61, 2020 Jan.
Article in English | MEDLINE | ID: mdl-31436615

ABSTRACT

BACKGROUND: Primary total hip arthroplasty (THA) has been suggested for posterior wall (PW) fractures with unfavorable features in the geriatric population. There is a paucity of studies reporting on postoperative protocols for primary THA after PW fractures. The purpose of this study was to test the biomechanical effect of immediate assisted weight-bearing on acetabulum THA cup fixation in an osteoporotic PW fracture model. METHODS: Computed tomography scans of 18 geriatric PW fractures (mean age, 77 ± 8 years) were used to generate representative PW fracture. This fracture pattern, comprising 50% of the PW and 25% of the acetabulum rim, was then created in 6 female cadaveric pelves. A multihole acetabulum THA cup was implanted with line-to-line reaming and fixed with four 5-mm screws. The pelves were cyclically loaded to up to 1.8× body weight (BW) in the intact form, after fracture creation and fracture fixation. Optical markers were used to determine acceptable cup motion of less than 150 µm. RESULTS: Five specimens withstood 3.6× BW loading after implantation and before fracture creation. At 1.8× BW load, cup motion was nonfractured: 50 ± 24 µm (range, 5-128 µm), fractured with no fixation: 37 ± 22 µm (range, 8-74 µm), or fractured with fixation: 62 ± 39 µm (range, 5-120 µm) (P = 0.0097). Cup motion was <150 µm for all groups. CONCLUSION: This study supports the practice of allowing immediate assisted weight-bearing in patients undergoing THA with PW fractures involving up to 50% of the PW and up to 25% of the acetabular rim, with or without fixation of the PW fragment.


Subject(s)
Arthroplasty, Replacement, Hip , Fractures, Bone , Acetabulum/diagnostic imaging , Acetabulum/surgery , Aged , Aged, 80 and over , Cadaver , Female , Fractures, Bone/diagnostic imaging , Fractures, Bone/surgery , Humans , Weight-Bearing
9.
J Am Acad Orthop Surg ; 28(13): e573-e579, 2020 Jul 01.
Article in English | MEDLINE | ID: mdl-31567899

ABSTRACT

BACKGROUND: The optimal treatment of acetabular fractures in the senior cohort is undetermined. Total hip arthroplasty in the setting of an acetabular fracture is increasing in popularity. However, there is concern regarding the fixation of a prosthetic cup in a fractured acetabulum. The purpose of this study is to map the area of stable articular surface and bone corridors available for cup fixation in this fracture cohort. METHODS: CT scans of acetabular fractures in 131 consecutive geriatric patients older than 65 years from two level 1 academic trauma centers were analyzed. Acetabular fractures were classified using the Letournel classification, the available stable articular surface, and the bone corridors available for fixation. RESULTS: Fractures involving the anterior column were the most common fracture type seen. The dome only pattern was the most common stable articular surface pattern. The sciatic corridor was available for fixation in all fracture types, followed by the gluteal pillar corridor. Most fractures had at least two corridors (93%) available for screw fixation. CONCLUSIONS: The findings of this study may aid in the development and evaluation of fixation strategies for acetabular cups allowing geriatric acetabular fracture patients earlier weight bearing after primary hip arthroplasty.


Subject(s)
Acetabulum/injuries , Acetabulum/surgery , Arthroplasty, Replacement, Hip/methods , Fracture Fixation, Internal/methods , Fractures, Bone/surgery , Prostheses and Implants , Prosthesis Design , Acetabulum/diagnostic imaging , Acetabulum/pathology , Aged , Bone Screws , Cohort Studies , Female , Fractures, Bone/classification , Fractures, Bone/diagnostic imaging , Fractures, Bone/pathology , Humans , Male , Time Factors , Tomography, X-Ray Computed , Weight-Bearing
10.
Injury ; 50(3): 627-632, 2019 Mar.
Article in English | MEDLINE | ID: mdl-30745127

ABSTRACT

INTRODUCTION: Acute compartment syndrome (ACS) is a limb-threatening condition often associated with leg injury. The only treatment of ACS is fasciotomy with the purpose of reducing muscle compartment pressures (MCP). Patient discomfort and low reliability of invasive MCP measurements, has led to the search for alternative methods. Our goal was to test the feasibility of using ultrasound to diagnose elevated MCP. METHODS: A cadaver model of elevated MCPs was used in 6 cadaver legs. An ultrasound transducer was combined with a pressure sensing transducer to obtain a B-mode image of the anterior compartment, while controlling the amount of pressure applied to the skin. MCP was increased from 0 to 75 mmHg. The width of the anterior compartment (CW) and the pressure needed to flatten the bulging superficial compartment fascia (CFFP) were measured. RESULTS: Both the CW and CFFP showed high correlations to MCP in the individual cadavers. Average CW and CFFP significantly increased between baseline and the first elevated MCP states. Both Inter-observer and intra-observer agreements for the ultrasound measurements were good to excellent. DISCUSSION: Ultrasound indexes showed excellent correlations in compartment pressures, suggesting that there is a potential for the clinical use of this modality in the future.


Subject(s)
Anterior Compartment Syndrome/diagnostic imaging , Leg Injuries/diagnostic imaging , Leg/diagnostic imaging , Muscle, Skeletal/diagnostic imaging , Ultrasonography, Interventional , Aged , Anterior Compartment Syndrome/pathology , Cadaver , Fasciotomy , Feasibility Studies , Female , Humans , Leg/physiopathology , Leg Injuries/pathology , Male , Muscle, Skeletal/pathology , Observer Variation , Reproducibility of Results
11.
Sci Rep ; 9(1): 2122, 2019 02 14.
Article in English | MEDLINE | ID: mdl-30765721

ABSTRACT

There are currently no standardized methods for assessing fracture healing, with physicians relying on X-rays which are only useful at later stages of repair. Using in vivo mouse fracture models, we present the first evidence that microscale instrumented implants provide a route for post-operative fracture monitoring, utilizing electrical impedance spectroscopy (EIS) to track the healing tissue with high sensitivity. In this study, we fixed mouse long bone fractures with external fixators and bone plates. EIS measurements taken across two microelectrodes within the fracture gap were able to track longitudinal differences between individual mice with good versus poor healing. We additionally present an equivalent circuit model that combines the EIS data to classify fracture repair states. Lastly, we show that EIS measurements strongly correlated with standard quantitative µCT values and that these correlations validate clinically-relevant operating frequencies for implementation of this technique. These results demonstrate that EIS can be integrated into current fracture management strategies such as bone plating, providing physicians with quantitative information about the state of fracture repair to guide clinical decision-making for patients.


Subject(s)
Bone Plates , Dielectric Spectroscopy/methods , Electric Impedance , Fracture Healing , Fractures, Bone/physiopathology , Monitoring, Physiologic/methods , Animals , Dielectric Spectroscopy/instrumentation , Fractures, Bone/surgery , Male , Mice , Mice, Inbred C57BL , Monitoring, Physiologic/instrumentation
12.
OTA Int ; 2(3): e034, 2019 Sep.
Article in English | MEDLINE | ID: mdl-33937656

ABSTRACT

OBJECTIVE: Mini-fragment plates (MFPs) are increasingly used in fracture surgery to provide provisional fixation. After definitive fixation, the surgeon decides whether to remove the plates or leave them in place as additional fixation, based on the perceived biomechanical influence of the MFP. However, there are no current biomechanical studies to guide this decision. Therefore, the purpose of this study was to evaluate the influence of MFPs on the four-point bending and torsional stiffness of long bone transverse and simple wedge fracture fixation constructs. METHODS: Fourth-generation composite bone cylinders were cut to produce transverse (AO-OTA classification 12-A3) and simple wedge (AO-OTA classification 12-B2) fracture models. The specimens were fixed using a low-contact dynamic compression plate (LC-DCP) and MFPs. Specimens were tested in four-point bending and torsion utilizing 3 different MFP orientations. RESULTS: No statistically significant differences in bending stiffness were found between control and MFP groups for transverse fracture constructs. MFPs significantly increased the bending stiffness for wedge fracture constructs under certain loading conditions. This increase was observed when MFPs were positioned both orthogonal (85.1% increase, P = .034) and opposite (848.2% increase, P < .001) to the LC-DCP. MFPs significantly increased the torsional stiffness for both transverse and wedge fracture constructs when MFPs were positioned both orthogonal (transverse: 27.7% increase, wedge: 16.7% increase) and opposite (transverse: 28.4%, wedge: 24.2% increase) to the LC-DCP. CONCLUSIONS: Our results indicate that including MFPs in definitive fixation can increase the bending and torsional stiffness of a long-bone fracture fixation construct. This suggests that the biomechanical influence of MFPs should be considered. However, clinical studies will be required to test the applicability of these findings to the clinical setting.

13.
Dev Biol ; 444 Suppl 1: S219-S236, 2018 12 01.
Article in English | MEDLINE | ID: mdl-29753626

ABSTRACT

How does form arise during development and change during evolution? How does form relate to function, and what enables embryonic structures to presage their later use in adults? To address these questions, we leverage the distinct functional morphology of the jaw in duck, chick, and quail. In connection with their specialized mode of feeding, duck develop a secondary cartilage at the tendon insertion of their jaw adductor muscle on the mandible. An equivalent cartilage is absent in chick and quail. We hypothesize that species-specific jaw architecture and mechanical forces promote secondary cartilage in duck through the differential regulation of FGF and TGFß signaling. First, we perform transplants between chick and duck embryos and demonstrate that the ability of neural crest mesenchyme (NCM) to direct the species-specific insertion of muscle and the formation of secondary cartilage depends upon the amount and spatial distribution of NCM-derived connective tissues. Second, we quantify motility and build finite element models of the jaw complex in duck and quail, which reveals a link between species-specific jaw architecture and the predicted mechanical force environment. Third, we investigate the extent to which mechanical load mediates FGF and TGFß signaling in the duck jaw adductor insertion, and discover that both pathways are mechano-responsive and required for secondary cartilage formation. Additionally, we find that FGF and TGFß signaling can also induce secondary cartilage in the absence of mechanical force or in the adductor insertion of quail embryos. Thus, our results provide novel insights on molecular, cellular, and biomechanical mechanisms that couple musculoskeletal form and function during development and evolution.


Subject(s)
Fibroblast Growth Factors/metabolism , Jaw/embryology , Transforming Growth Factor beta/metabolism , Animals , Biological Evolution , Cartilage/metabolism , Cell Movement , Chick Embryo , Chondrogenesis , Ducks/embryology , Embryo, Nonmammalian/metabolism , Fibroblast Growth Factors/physiology , Gene Expression Regulation, Developmental/genetics , Jaw/physiology , Mandible/embryology , Mesoderm/embryology , Neural Crest/embryology , Neural Crest/physiology , Quail/embryology , Signal Transduction/physiology , Species Specificity , Transforming Growth Factor beta/physiology
14.
Hand (N Y) ; 13(3): 336-340, 2018 05.
Article in English | MEDLINE | ID: mdl-28387161

ABSTRACT

BACKGROUND: The goal of this study was to compare the biomechanical stability of a 2.4-mm dorsal spanning bridge plate with a volar locking plate (VLP) in a distal radius fracture model, during simulated crutch weight-bearing. METHODS: Five paired cadaveric forearms were tested. A 1-cm dorsal wedge osteotomy was created to simulate an unstable distal radius fracture with dorsal comminution. Fractures were fixed with a VLP or a dorsal bridge plate (DBP). Specimens were mounted to a crutch handle, and optical motion-tracking sensors were attached to the proximal and distal segments. Specimens were loaded in compression at 1 mm/s on a servohydraulic test frame until failure, defined as 2 mm of gap site displacement. RESULTS: The VLP construct was significantly more stable to axial load in a crutch weight-bearing model compared with the DBP plate (VLP: 493 N vs DBP: 332 N). Stiffness was higher in the VLP constructs, but this was not statistically significant (VLP: 51.4 N/mm vs DBP: 32.4 N/mm). With the crutch weight-bearing model, DBP failed consistently with wrist flexion and plate bending, whereas VLP failed with axial compression at the fracture site and dorsal collapse. CONCLUSIONS: Dorsal spanning bridge plating is effective as an internal spanning fixator in treating highly comminuted intra-articular distal radius fracture and prevents axial collapse at the radiocarpal joint. However, bridge plating may not offer advantages in early weight-bearing or transfer in polytrauma patients, with less axial stability in our crutch weight-bearing model compared with volar plating. A stiffer 3.5-mm DBP or use of a DBP construct without the central holes may be considered for distal radius fractures if the goal is early crutch weight-bearing through the injured extremity.


Subject(s)
Bone Plates , Fracture Fixation, Internal/instrumentation , Fractures, Comminuted/surgery , Materials Testing , Radius Fractures/surgery , Weight-Bearing , Aged , Cadaver , Female , Humans , Male , Prosthesis Design
15.
Annu Int Conf IEEE Eng Med Biol Soc ; 2017: 1724-1727, 2017 Jul.
Article in English | MEDLINE | ID: mdl-29060219

ABSTRACT

Fracture injuries are highly prevalent worldwide, with treatment of problematic fractures causing a significant burden on the U.S. healthcare system. Physicians typically monitor fracture healing by conducting physical examinations and taking radiographic images. However, nonunions currently take over 6 months to be diagnosed because these techniques are not sensitive enough to adequately assess fracture union. In this study, we display the utility of impedance spectroscopy to track different healing rates in a pilot study of an in vivo mouse tibia fracture model. We have developed small (56 µm) sensors and implanted them in an externally-stabilized fracture for twice-weekly measurement. We found that impedance magnitude increases steadily over time in healing mice but stalls in non-healing mice, and phase angle displays frequency-dependent behavior that also reflects the extent of healing at the fracture site. Our results demonstrate that impedance can track differences in healing rates early on, highlighting the potential of this technique as a method for early detection of fracture nonunion.


Subject(s)
Fracture Healing , Animals , Electric Impedance , Fractures, Ununited , Mice , Pilot Projects , Tibial Fractures
16.
J Orthop Res ; 35(12): 2620-2629, 2017 12.
Article in English | MEDLINE | ID: mdl-28383765

ABSTRACT

Accurate evaluation of fracture healing is important for clinical decisions on when to begin weight-bearing and when early intervention is necessary in cases of fracture nonunion. While the stages of healing involving hematoma, cartilage, trabecular bone, and cortical bone have been well characterized histologically, physicians typically track fracture healing by using subjective physical examinations and radiographic techniques that are only able to detect mineralized stages of bone healing. This exposes the need for a quantitative, reliable technique to monitor fracture healing, and particularly to track healing progression during the early stages of repair. The goal of this study was to validate the use of impedance spectroscopy to monitor fracture healing and perform comprehensive evaluation comparing measurements with histological evidence. Here, we show that impedance spectroscopy not only can distinguish between cadaver tissues involved throughout fracture repair, but also correlates to fracture callus composition over the middle stages of healing in wild-type C57BL/6 mice. Specifically, impedance magnitude has a positive relationship with % trabecular bone and a negative relationship with % cartilage, and the opposite relationships are found when comparing phase angle to these same volume fractions of tissues. With this information, we can quantitatively evaluate how far a fracture has progressed through the healing stages. Our results demonstrate the feasibility of impedance spectroscopy for detection of fracture callus composition and reveals its potential as a method for early detection of bone healing and fracture nonunion. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:2620-2629, 2017.


Subject(s)
Bony Callus/pathology , Dielectric Spectroscopy , Fracture Healing , Fractures, Bone/pathology , Animals , Bone Plates , Electric Impedance , Humans , Male , Mice, Inbred C57BL
17.
J Orthop Trauma ; 31(2): e49-e54, 2017 Feb.
Article in English | MEDLINE | ID: mdl-28129271

ABSTRACT

OBJECTIVES: The goal of this study is to compare the fatigue strength of a locking intramedullary nail (LN) construct with a double locking plate (DLP) construct in comminuted proximal extra-articular tibia fractures. METHODS: Eight pairs of fresh frozen cadaveric tibias with low bone mineral density [age: 80 ± 7 (SD) years, T-score: -2.3 ± 1.2] were used. One tibia from each pair was fixed with LN, whereas the contralateral side was fixed with DLP for complex extra-articular multifragmentary metaphyseal fractures (simulating OTA 41-A3.3). Specimens were cyclically loaded under compression simulating single-leg stance by staircase method out to 260,000 cycles. Every 2500 cycles, localized gap displacements were measured with a 3D motion tracking system, and x-ray images of the proximal tibia were acquired. To allow for mechanical settling, initial metrics were calculated at 2500 cycles. The 2 groups were compared regarding initial construct stiffness, initial medial and lateral gap displacements, stiffness at 30,000 cycles, medial and lateral gap displacements at 30,000 cycles, failure load, number of cycles to failure, and failure mode. Failure metrics were reported for initial and catastrophic failures. RESULTS: DLP constructs exhibited higher initial stiffness and stiffness at 30,000 cycles compared with LN constructs (P < 0.03). There were no significant differences between groups for loads at failure or cycles to failure. CONCLUSIONS: For the fixation of extra-articular proximal tibia fractures, a LN provides a similar fatigue performance to double locked plates. The locked nail could be safely used for fixation of proximal tibia fractures with the advantage of limited extramedullary soft tissue damage.


Subject(s)
Bone Plates , Bone Screws , Fracture Fixation, Intramedullary/instrumentation , Prosthesis Failure , Tibial Fractures/physiopathology , Tibial Fractures/surgery , Aged , Aged, 80 and over , Cadaver , Equipment Failure Analysis , Female , Friction , Humans , Male , Motion , Prosthesis Design , Stress, Mechanical , Tensile Strength
18.
Spine (Phila Pa 1976) ; 40(23): E1219-25, 2015 Dec.
Article in English | MEDLINE | ID: mdl-26192728

ABSTRACT

STUDY DESIGN: Biomechanical. OBJECTIVE: Evaluate spinal stability achieved with different levels of posterior percutaneous fixation (postPerc) for thoracolumbar fractures in cadavers subjected to ICU activities. SUMMARY OF BACKGROUND DATA: "Spine damage control" involves postPerc performed within 24 hours of injury and staged, elective, definitive stabilization. Amount of instrumentation needed to initially achieve adequate spinal stability, minimize morbidity, and accommodate ICU care needs between stages are not defined. METHODS: In full-unembalmed cadavers motion-tracking sensors were placed at T11 and L1. A T12 corpectomy with PLC injury was stabilized with 1, 2, and 3 levels of PostPerc above/below the injury. Motions between T11 and L1 were measured during Log-Roll and Sit-Up on an ICU bed. After in situ testing, anatomic spinal motion ranges were determined under pure moment loads. RESULTS: 5 cadavers were evaluated. For Log-Roll, 2 and 3 levels above/below restored stability to intact, whereas 1 level above/below did not for axial rotation. For translation, all instrumentation restored stability to intact. During Sit-Up, a linear increase in flexion was observed. At 45° Sit-Up, 2 and 3 levels above/below were similar to intact for flexion; 1 level above/below had significantly more flexion. All instrumentations restored translation to intact for Sit-Up; significantly more axial collapse occurred for instrumentation compared with intact. During ex situ testing, 2 and 3 levels above/below were similar; 1 level above/below had significantly greater laxity in flexion, extension, and axial rotation. CONCLUSION: Posterior instrumentation 2 or 3 levels above/below a severe thoracolumbar fracture model can restore spinal stability back to its intact condition. 2 levels of fixation above/below this "worst-case scenario" is minimum fixation sufficient to provide absolute spinal stability in the ICU setting as a "Damage Control" technique in patients with polytrauma. In less severe injury models, 1 level of fixation above/below may provide adequate spinal stability; although this should be confirmed in future investigations. LEVEL OF EVIDENCE: N/A.


Subject(s)
Biomechanical Phenomena/physiology , Lumbar Vertebrae , Spinal Fusion , Thoracic Vertebrae , Aged , Aged, 80 and over , Female , Humans , Lumbar Vertebrae/injuries , Lumbar Vertebrae/physiopathology , Lumbar Vertebrae/surgery , Male , Middle Aged , Models, Biological , Thoracic Vertebrae/injuries , Thoracic Vertebrae/physiopathology , Thoracic Vertebrae/surgery
19.
Injury ; 46(6): 963-9, 2015.
Article in English | MEDLINE | ID: mdl-25818058

ABSTRACT

OBJECTIVES: Short and long cephalomedullary (CM) nails are commonly used construct for fixation of intertrochanteric (IT) fractures. Each of these constructs has its advantages and its shortcomings. The extended-short (ES) CM nail offers a hybrid between long and short nail design that aims to combine their respective benefits. The goals of this study were to (1) biomechanically evaluate and compare construct stiffness for the long, short and ES constructs in the fixation of IT fractures, and to (2) investigate the nature of periprosthetic fractures of constructs implanted with these various designs. METHODS: Eighteen synthetic femora were used to evaluate three types of fracture fixation constructs. Axial compression, bending, and torsional stiffness were reported for both stable and comminuted IT fracture models. All comminuted fracture constructs were loaded to failure in axial compression to measure failure loads and evaluate periprosthetic fracture patterns. RESULTS: Stiffness were similar among constructs with few exceptions. Axial stiffness was significantly higher for the short nail compared to the long nail for the comminuted model (p= 0.020). ES nail constructs exhibited a significantly higher failure load than short nail constructs (p = 0.039). Periprosthetic fractures occurred around the distal interlocking screw in all constructs. CONCLUSIONS: Nail length and position of interlocking screw did not alter the biomechanical properties of the fixation construct in the presented IT fracture model. Periprosthetic fractures generated in this study had similar patterns to those seen clinically. This study also suggests that if a periprosthetic fracture is to occur, there is an increased probability of it happening around the site of the interlocking screw, regardless of nail design.


Subject(s)
Bone Nails , Femoral Fractures/surgery , Fracture Fixation, Intramedullary , Fractures, Comminuted/surgery , Hip Fractures/surgery , Biomechanical Phenomena , Fracture Fixation, Intramedullary/methods , Humans
20.
Article in English | MEDLINE | ID: mdl-26737448

ABSTRACT

An estimated 7.9 million fracture injuries occur each year in the United States, of which a substantial fraction result in delayed or non-union. Current methods of monitoring fracture healing include taking x-rays and making clinical observations. However, x-ray confirmation of bone healing typically lags behind biologic healing, and physician assessment of healing is fraught with subjectivity. No standardized methods exist to assess the extent of healing that has taken place in a fracture. Without such knowledge, interventions to aid healing and prevent fracture non-union are often delayed, leading to increased morbidity and suffering to patients. We are developing an objective measurement tool that utilizes electrical impedance spectroscopy to distinguish between the various types of tissue present during the different stages of fracture healing. Preliminary measurements of cadaveric tissues reveal adequate spread in impedance measurements and differences in frequency response among different tissue types. Electrodes implanted in a simulated fracture created in an ex vivo cadaver model yield promising results for our system's ability to differentiate between the stages of fracture healing.


Subject(s)
Dielectric Spectroscopy/methods , Fracture Healing/physiology , Fractures, Bone/physiopathology , Monitoring, Physiologic/methods , Dielectric Spectroscopy/instrumentation , Equipment Design , Feasibility Studies , Humans , Monitoring, Physiologic/instrumentation