1.
MAGMA ; 25(5): 391-9, 2012 Oct.
Article in English | MEDLINE | ID: mdl-22644411

ABSTRACT

OBJECT: To demonstrate that adenosine triphosphate (ATP), which provides a valuable biomarker for kidney viability in the context of donation after cardiac death (DCD) transplantation, can be detected by means of (31)P magnetic resonance spectroscopy (MRS) if kidneys are perfused with oxygenated hypothermic pulsatile perfusion (O(2)+HPP). MATERIALS AND METHODS: Porcine kidney perfusion was carried out using a home made, MR-compatible HPP-machine. Consequently, kidney perfusion could be performed continuously during magnetic resonance imaging and magnetic resonance spectroscopy recording. (31)P MR spectroscopy consisted of 3-dimensional chemical shift imaging (CSI), which allowed for the detection of ATP level in line. (31)P CSI was performed at 3 tesla in 44 min with a nominal voxel size of 6.1 cc. RESULTS: (31)P CSI enabled the detection of renal ATP when pO(2) was equal to 100 kPa. With pO(2) of 20 kPa, only phosphomonoester, inorganic phosphate and nicotinamide adenine dinucleotide could be found. Semi-quantitative analysis showed that ATP level was 1.3 mM in normal kidney perfused with pO(2) of 100 kPa. CONCLUSIONS: This combined technology may constitute a new advance in DCD organ diagnostics prior to transplantation, as it allows direct assessment of ATP concentration, which provides a reliable indicator for organ bioenergetics and viability. In this study, kidneys presenting no warm ischemia were tested in order to establish values in normal organs. The test could be easily integrated into the clinical environment and would not generate any additional delay into the transplantation clinical workflow.


Subject(s)
Adenosine Triphosphate/analysis , Kidney/metabolism , Magnetic Resonance Spectroscopy/methods , Oxygen/chemistry , Phosphorus Isotopes/pharmacology , Pulsatile Flow , Adenosine Triphosphate/chemistry , Animals , Cell Survival , Death , Equipment Design , Ischemia/pathology , Kidney Transplantation/methods , Magnetic Resonance Imaging/methods , Organ Preservation/methods , Swine , Time Factors
2.
Magn Reson Imaging ; 27(8): 1011-8, 2009 Oct.
Article in English | MEDLINE | ID: mdl-19261421

ABSTRACT

In this investigation, high-resolution, 1x1x1-mm(3) functional magnetic resonance imaging (fMRI) at 7 T is performed using a multichannel array head coil and a surface coil approach. Scan geometry was optimized for each coil separately to exploit the strengths of both coils. Acquisitions with the surface coil focused on partial brain coverage, while whole-brain coverage fMRI experiments were performed with the array head coil. BOLD sensitivity in the occipital lobe was found to be higher with the surface coil than with the head array, suggesting that restriction of signal detection to the area of interest may be beneficial for localized activation studies. Performing independent component analysis (ICA) decomposition of the fMRI data, we consistently detected BOLD signal changes and resting state networks. In the surface coil data, a small negative BOLD response could be detected in these resting state network areas. Also in the data acquired with the surface coil, two distinct components of the positive BOLD signal were consistently observed. These two components were tentatively assigned to tissue and venous signal changes.


Subject(s)
Brain Mapping/instrumentation , Brain/physiology , Evoked Potentials/physiology , Image Enhancement/instrumentation , Magnetic Resonance Imaging/instrumentation , Magnetics/instrumentation , Transducers , Brain/anatomy & histology , Brain Mapping/methods , Computer-Aided Design , Equipment Design , Equipment Failure Analysis , Humans , Magnetic Resonance Imaging/methods , Radio Waves , Reproducibility of Results , Sensitivity and Specificity
3.
Magn Reson Med ; 61(6): 1279-85, 2009 Jun.
Article in English | MEDLINE | ID: mdl-19319893

ABSTRACT

Recently, the spin-echo full-intensity acquired localized (SPECIAL) spectroscopy technique was proposed to unite the advantages of short TEs on the order of milliseconds (ms) with full sensitivity and applied to in vivo rat brain. In the present study, SPECIAL was adapted and optimized for use on a clinical platform at 3T and 7T by combining interleaved water suppression (WS) and outer volume saturation (OVS), optimized sequence timing, and improved shimming using FASTMAP. High-quality single voxel spectra of human brain were acquired at TEs below or equal to 6 ms on a clinical 3T and 7T system for six volunteers. Narrow linewidths (6.6 +/- 0.6 Hz at 3T and 12.1 +/- 1.0 Hz at 7T for water) and the high signal-to-noise ratio (SNR) of the artifact-free spectra enabled the quantification of a neurochemical profile consisting of 18 metabolites with Cramér-Rao lower bounds (CRLBs) below 20% at both field strengths. The enhanced sensitivity and increased spectral resolution at 7T compared to 3T allowed a two-fold reduction in scan time, an increased precision of quantification for 12 metabolites, and the additional quantification of lactate with CRLB below 20%. Improved sensitivity at 7T was also demonstrated by a 1.7-fold increase in average SNR (= peak height/root mean square [RMS]-of-noise) per unit-time.


Subject(s)
Algorithms , Brain Chemistry , Magnetic Resonance Spectroscopy/methods , Neurotransmitter Agents/analysis , Humans , Protons , Reproducibility of Results , Sensitivity and Specificity
4.
MAGMA ; 22(1): 1-4, 2009 Feb.
Article in English | MEDLINE | ID: mdl-18949497

ABSTRACT

OBJECT: To determine whether glycine can be measured at 7 T in human brain with (1)H magnetic resonance spectroscopy (MRS). MATERIALS AND METHODS: The glycine singlet is overlapped by the larger signal of myo-inositol. Density matrix simulations were performed to determine the TE at which the myo-inositol signal was reduced the most, following a single spin-echo excitation. (1)H MRS was performed on an actively shielded 7 T scanner, in five healthy volunteers. RESULTS: At the TE of 30 ms, the myo-inositol signal intensity was substantially reduced. Quantification using LCModel yielded a glycine-to-creatine ratio of 0.14 +/- 0.01, with a Cramér-Rao lower bound (CRLB) of 7 +/- 1%. Furthermore, quantification of metabolites other than glycine was possible as well, with a CRLB mostly below 10%. CONCLUSION: It is possible to detect glycine at 7 T in human brain, at the short TE of 30 ms with a single spin-echo excitation scheme.


Subject(s)
Algorithms , Brain/metabolism , Glycine/analysis , Magnetic Resonance Spectroscopy/methods , Neurotransmitter Agents/analysis , Humans , Protons , Reproducibility of Results , Sensitivity and Specificity