Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Comput Biol Med ; 159: 106920, 2023 06.
Article in English | MEDLINE | ID: mdl-37119551

ABSTRACT

BACKGROUND: Repetitive atrial activation patterns (RAAPs) during atrial fibrillation (AF) may be associated with localized mechanisms that maintain AF. Current electro-anatomical mapping systems are unsuitable for analyzing RAAPs due to the trade-off between spatial coverage and electrode density in clinical catheters. This work proposes a technique to overcome this trade-off by constructing composite maps from spatially overlapping sequential recordings. METHODS: High-density epicardial contact mapping was performed during open-chest surgery in goats (n=16, left and right atria) with 3 or 22 weeks of sustained AF (249-electrode array, electrode distance 2.4 mm). A dataset mimicking sequential recordings was generated by segmenting the grid into four spatially overlapping regions (each region 6.5 cm2, 48±10% overlap) without temporal overlap. RAAPs were detected in each region using recurrence plots of activation times. RAAPs in two different regions were joined in case of RAAP cross-recurrence between overlapping electrodes. We quantified the reconstruction success rate and quality of the composite maps. RESULTS: Of 1021 RAAPs found in the full mapping array (32±13 per recording), 328 spatiotemporally stable RAAPs were analyzed. 247 composite maps were generated (75% success) with a quality of 0.86±0.21 (Pearson correlation). Success was significantly affected by the RAAP area. Quality was weakly correlated with the number of repetitions of RAAPs (r=0.13, p<0.05) and not affected by the atrial side (left or right) or AF duration (3 or 22 weeks of AF). CONCLUSIONS: Constructing composite maps by combining spatially overlapping sequential recordings is feasible. Interpretation of these maps can play a central role in ablation planning.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Catheter Ablation , Humans , Atrial Fibrillation/surgery , Heart Atria , Epicardial Mapping/methods , Action Potentials
2.
PLoS One ; 14(8): e0221220, 2019.
Article in English | MEDLINE | ID: mdl-31437178

ABSTRACT

The conclusion of our recent paper that performance of the STAN device in clinical practice is potentially limited by high false-negative and high false-positive STAN-event rates and loss of ST waveform assessment capacity during severe hypoxemia, evoked comments by Kjellmer, Lindecrantz and Rosén. These comments can be summarized as follows: 1) STAN analysis is based on a unipolar lead but the authors used a negative aVF lead, and they did not validate this methodology; 2) The fetuses used in the study were too young to display the signals that the authors were trying to detect. In response to these comments we now provide both a theoretical and an experimental underpinning of our approach. In an in vivo experiment in human we placed several electrodes over the head (simulating different places of a scalp electrode), simultaneously recorded Einthoven lead I and II, and constructed -aVF from these two frontal leads. Irrespective of scalp electrode placement, the correlation between any of unipolar scalp electrode-derived signals and constructed-aVF was excellent (≥ 0.92). In response to the second comment we refer to a study which demonstrated that umbilical cord occlusion resulted in rapid increase in T/QRS ratio that coincided with initial hypertension and bradycardia at all gestational ages which were tested from 0.6-0.8 gestation. The animals of our study were in this gestational range and, hence, our experimental setup can be used to assess STAN's quality to detect fetal hypoxia. In conclusion, we have clearly demonstrated the appropriateness of using-aVF as a proxy for a scalp electrode-derived signal in STAN in these preterm lambs. Investigation why STAN could not detect relevant ST-changes and instead produced erroneous alarms in our experimental setup is hampered by the fact that the exact STAN algorithm (signal processing and analysis) is not in the public domain.


Subject(s)
Electrocardiography , Scalp , Animals , Electrodes , Female , Fetus , Humans , Hypoxia , Pregnancy , Sheep , Umbilical Cord
3.
Pediatr Res ; 79(6): 907-15, 2016 06.
Article in English | MEDLINE | ID: mdl-26866904

ABSTRACT

BACKGROUND: Current methods for assessing perinatal hypoxic conditions did not improve infant outcomes. Various waveform-based and interval-based ECG markers have been suggested, but not directly compared. We compare performance of ECG markers in a standardized ovine model for fetal hypoxia. METHODS: Sixty-nine fetal sheep of 0.7 gestation had ECG recorded 4 h before, during, and 4 h after a 25-min period of umbilical cord occlusion (UCO), leading to severe hypoxia. Various ECG markers were calculated, among which were heart rate (HR), HR-corrected ventricular depolarization/repolarization interval (QTc), and ST-segment analysis (STAN) episodic and baseline rise markers, analogue to clinical STAN device alarms. Performance of interval- and waveform-based ECG markers was assessed by correlating predicted and actual hypoxic/normoxic state. RESULTS: Of the markers studied, HR and QTc demonstrated high sensitivity (≥86%), specificity (≥96%), and positive predictive value (PPV) (≥86%) and detected hypoxia in ≥90% of fetuses at 4 min after UCO. In contrast, STAN episodic and baseline rise markers displayed low sensitivity (≤20%) and could not detect severe fetal hypoxia in 65 and 28% of the animals, respectively. CONCLUSION: Interval-based HR and QTc markers could assess the presence of severe hypoxia. Waveform-based STAN episodic and baseline rise markers were ineffective as markers for hypoxia.


Subject(s)
Electrocardiography , Hypoxia/diagnosis , Ischemia/diagnosis , Animals , Animals, Newborn , Disease Models, Animal , Female , Heart Rate , Hydrogen-Ion Concentration , Male , ROC Curve , Sensitivity and Specificity , Sheep , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...