Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 60
Filter
1.
Catheter Cardiovasc Interv ; 68(5): 677-83, 2006 Nov.
Article in English | MEDLINE | ID: mdl-17039508

ABSTRACT

BACKGROUND: The StarClose Vascular Closure System is a femoral access site closure technology that uses a flexible nitinol clip to complete a circumferential, extravascular arteriotomy close. The Clip CLosure In Percutaneous Procedures study was initiated to study the safety and efficacy of the StarClose device in subjects undergoing diagnostic and interventional catheterization procedures. METHODS: A total of 17 U.S. sites enrolled 596 subjects, with 483 subjects randomized at a 2:1 ratio to receive StarClose or standard compression of the arteriotomy after the percutaneous procedure. The study included roll-in (n = 113), diagnostic (n = 208), and interventional (n = 275) arms with a primary safety endpoint of major vascular complications through 30 days and a primary efficacy endpoint of postprocedure time to hemostasis. RESULTS: The results of the diagnostic StarClose cohort have been reported separately. Results for the interventional arm revealed major vascular complications occurring in 1.1% of StarClose subjects (2/184) and 1.1% in manual compression subjects (1/91; P = 1.00). No infections were seen in either cohort. Minor complications in the StarClose interventional group occurred at a rate of 4.3% (8/184) and with compression at 9.9% (9/91; P = 0.107). Pseudoaneurysm or arteriovenous fistula was not seen with StarClose. With StarClose, procedural success was 100% (136/136) for the diagnostic group and 98.9% (181/183) in the interventional group. Device success for the treatment group was 86.8%. In the interventional cohort, 87.3% (158/181) of StarClose subjects reported a pain scale of 0-3 compared with 93.3% (84/90) in the compression group, which was not statistically different. CONCLUSIONS: The clinical results of this study demonstrate that the StarClose Vascular Closure System is noninferior to manual compression with respect to the primary safety endpoint of major vascular events in subjects who undergo percutaneous interventional procedures. StarClose significantly reduced time to hemostasis, ambulation, and dischargeability when compared with compression.


Subject(s)
Cardiac Catheterization/instrumentation , Femoral Artery/surgery , Hemostatic Techniques/instrumentation , Surgical Instruments , Aged , Alloys , Cardiac Catheterization/adverse effects , Equipment Design , Equipment Safety , Female , Follow-Up Studies , Hemostasis , Humans , Male , Middle Aged , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Prospective Studies , Surgical Instruments/adverse effects , Treatment Outcome , United States/epidemiology , Vascular Diseases/epidemiology , Vascular Diseases/etiology
2.
Catheter Cardiovasc Interv ; 68(5): 684-9, 2006 Nov.
Article in English | MEDLINE | ID: mdl-17039509

ABSTRACT

BACKGROUND: The StarClose Vascular Closure System (Abbott Vascular, Redwood City, CA) features a nitinol clip that is designed to achieve closure of the femoral arteriotomy access site. The CLIP Study was performed to assess the safety and efficacy of StarClose when compared with standard manual compression following 5-6 French diagnostic or interventional percutaneous procedures. A substudy of this trial was designed to assess the utility of duplex ultrasonography to assess patency of the femoral artery and to determine access site complications (pseudoaneurysm, arteriovenous fistula, hematoma, deep vein thrombosis) in a multicenter prospective trial. This is the report of the duplex ultrasound (DUS) substudy of the CLIP trial. METHODS: A total of 17 U.S. sites enrolled 596 subjects with 483 subjects randomized at a 2:1 ratio to receive StarClose or manual compression of the arteriotomy after a percutaneous procedure. The study included roll-in (n = 113), diagnostic (n = 208), and interventional (n = 275) arms with a primary safety endpoint of major vascular complications through 30 days and a primary efficacy endpoint of postprocedure time to hemostasis. A substudy of the CLIP interventional arm evaluated DUS images of the closure site at five study sites, targeting 100 subjects at day 30 following hemostasis. The DUS protocol was devised and implemented by an independent vascular ultrasound core laboratory with extensive experience in vascular device trials. DUS inguinal region from 6 cm proximal to 6 cm distal to the arteriotomy puncture was performed. A qualitative examination was performed to determine the presence of iatrogenic vascular injuries: hematoma, pseudoaneurysm (PSA), arteriovenous fistula (AVF), and arterial/venous thrombosis or stenosis using 2-dimensional gray scale, color, and focused Doppler images. RESULTS: DUS of 96 subjects randomized to StarClose (n = 71) and compression (n = 25) were performed and evaluated. There was no evidence of hematoma, PSA, or AVF observed in the StarClose group. No StarClose subjects in the substudy had a PSA or AVF. All patients in the substudy demonstrated patency of the access site artery and vein without thrombosis or stenosis. Finally, in the entire study cohort, no clinically-driven DUS studies demonstrated iatrogenic vascular injury or vessel thrombosis in the StarClose treated patients. CONCLUSION: DUS, a safe and reliable method for determining the safety and efficacy of access site closure devices, is a reliable, safe, inexpensive and accurate method of assessing vascular access site complications in multicenter trials. In this substudy of the CLIP study, DUS found no statistical difference in access site complications between the StarClose and manual compression groups. Both groups maintained vessel patency without stenosis, thrombosis, hematoma, pseudoaneurysm, or AV fistula.


Subject(s)
Cardiac Catheterization/instrumentation , Hemostatic Techniques/instrumentation , Surgical Instruments , Ultrasonography, Doppler, Duplex , Ultrasonography, Interventional , Adult , Aged , Alloys , Aneurysm, False/diagnostic imaging , Aneurysm, False/etiology , Arterial Occlusive Diseases/diagnostic imaging , Arterial Occlusive Diseases/etiology , Arteriovenous Fistula/diagnostic imaging , Arteriovenous Fistula/etiology , Collateral Circulation , Equipment Design/instrumentation , Equipment Safety/instrumentation , Female , Femoral Artery/diagnostic imaging , Femoral Artery/surgery , Femoral Vein/diagnostic imaging , Femoral Vein/surgery , Follow-Up Studies , Hematoma/diagnostic imaging , Hematoma/etiology , Hemostasis , Humans , Male , Middle Aged , Postoperative Complications/diagnostic imaging , Postoperative Complications/etiology , Prospective Studies , Reproducibility of Results , Saphenous Vein/diagnostic imaging , Saphenous Vein/surgery , Surgical Instruments/adverse effects , Treatment Outcome , Vascular Patency , Venous Thrombosis/diagnostic imaging , Venous Thrombosis/etiology
3.
Am J Cardiol ; 88(2): 192-5, A6-7, 2001 Jul 15.
Article in English | MEDLINE | ID: mdl-11448424

ABSTRACT

The Therapeutic Angiogenesis With Recombinant Fibroblast Growth Factor-2 for Intermittent Claudication (TRAFFIC) is a large, randomized, placebo-controlled, regimen-finding trial of intra-arterial recombinant fibroblast growth factor-2 in patients with intermittent claudication. This report describes the major design considerations and end points in TRAFFIC.


Subject(s)
Fibroblast Growth Factor 2/therapeutic use , Intermittent Claudication/drug therapy , Neovascularization, Physiologic/drug effects , Double-Blind Method , Humans , Recombinant Proteins/therapeutic use , Research Design
4.
Am J Cardiol ; 87(2): 152-6, 2001 Jan 15.
Article in English | MEDLINE | ID: mdl-11152830

ABSTRACT

The NIR stent is a novel second generation tubular stent that was designed to overcome some of the limitations of the earlier Palmaz-Schatz (PS) stent design. The NIR Vascular Advanced North American (NIRVANA) trial randomized 849 patients with single coronary lesions to treatment with the NIR stent or the PS stent. The study was an "equivalency" trial, designed to demonstrate that the NIR stent was not inferior to (i.e., equivalent or better than) the PS stent, for the primary end point of target vessel failure (defined as death, myocardial infarction, or target vessel revascularization) by 9 months. Successful stent delivery was achieved in 100% versus 98.8%, respectively, with a slightly lower postprocedural diameter stenosis (7% vs. 9%, p = 0.04) after NIR and PS stent placement, respectively. Major adverse cardiac events (death, myocardial infarction, repeat target lesion revascularization) were not different at 30 days (4.3% vs. 4.4%). The primary end point of target vessel failure at 9 months was seen in 16.0% of NIR versus 17.2% of PS patients, with the NIR proving to be equal or superior to the PS stent (p <0.001 by test for equivalency). Angiographic restudy in 71% of a prespecified cohort showed no significant difference in restenosis (19.3% vs 22.4%). Thus, the NIR stent showed excellent deliverability with slightly better acute angiographic results and equivalent or better 9-month target vessel failure rate when compared with the PS stent.


Subject(s)
Angioplasty, Balloon, Coronary , Coronary Disease/therapy , Stents , Aged , Coronary Angiography , Equipment Design , Female , Humans , Male , Middle Aged , Recurrence , Regression Analysis , Survival Analysis , Treatment Outcome
7.
Am J Cardiol ; 86(3): 336-41, 2000 Aug 01.
Article in English | MEDLINE | ID: mdl-10922447

ABSTRACT

The cumulative experience of 4 clinical trials using the MULTI-LINK coronary stent design was analyzed. Multivariable logistic regression identified postprocedure in-stent minimum lumen diameter (p = 0.0001), stent length (p = 0.0038), smoking (p = 0.0105). and diabetes (p = 0.0803) as the most important predictors of in-stent restenosis at late (6- to 9-month) angiographic follow-up.


Subject(s)
Angioplasty, Balloon, Coronary/instrumentation , Coronary Disease/therapy , Stents , Adult , Aged , Clinical Trials as Topic , Coronary Angiography , Coronary Disease/diagnostic imaging , Equipment Failure , Female , Follow-Up Studies , Humans , Male , Middle Aged , Prosthesis Design , Recurrence
8.
Circulation ; 101(18): 2172-7, 2000 May 09.
Article in English | MEDLINE | ID: mdl-10801758

ABSTRACT

BACKGROUND: Previous in vitro and in vivo studies have suggested an association between thrombus-related events and type of contrast media. Low osmolar contrast agents appear to improve the safety of diagnostic and coronary artery interventional procedures. However, no data are available on PTCA outcomes with an isosmolar contrast agent. METHODS AND RESULTS: A multicenter prospective randomized double-blind trial was performed in 856 high-risk patients undergoing coronary artery intervention. The objective was to compare the isosmolar nonionic dimer iodixanol (n=405) with the low osmolar ionic agent ioxaglate (n=410). A composite variable of in-hospital major adverse clinical events (MACE) was the primary end point. A secondary objective was to evaluate major angiographic and procedural events during and after PTCA. The composite in-hospital primary end point was less frequent in those receiving iodixanol compared with those receiving ioxaglate (5.4% versus 9.5%, respectively; P=0.027). Core laboratory defined angiographic success was more frequent in patients receiving iodixanol (92.2% versus 85. 9% for ioxaglate, P=0.004). There was a trend toward lower total clinical events at 30 days in patients randomized to iodixanol (9.1% versus 13.2% for ioxaglate, P=0.07). Multivariate predictors of in-hospital MACE were use of ioxaglate (P=0.01) and treatment of a de novo lesion (P=0.03). CONCLUSIONS: In this contemporary prospective multicenter trial of PTCA in the setting of acute coronary syndromes, there was a low incidence of in-hospital clinical events for both treatment groups. The cohort receiving the nonionic dimer iodixanol experienced a 45% reduction in in-hospital MACE when compared with the cohort receiving ioxaglate.


Subject(s)
Angioplasty, Balloon, Coronary , Contrast Media/adverse effects , Coronary Disease/therapy , Ioxaglic Acid/adverse effects , Triiodobenzoic Acids/adverse effects , Aged , Angioplasty, Balloon, Coronary/methods , Double-Blind Method , Female , Humans , Male , Middle Aged , Treatment Outcome
9.
Am J Cardiol ; 85(4): 435-40, 2000 Feb 15.
Article in English | MEDLINE | ID: mdl-10728946

ABSTRACT

Abciximab, an Fab monoclonal antibody fragment that blocks the platelet glycoprotein IIb/IIIa receptor, is increasingly used as an adjunct to coronary intervention. Little is known, however, about the efficacy and safety of readministration of abciximab. This study examined and characterized outcomes of patients receiving abciximab for a second time. From April 1995 to June 1997, 164 consecutive patients were readministered abciximab at our 3 institutions. We retrospectively examined and analyzed in-hospital outcomes in this cohort. The median time to readministration was 95 days. The angiographic success rate of percutaneous intervention was 99.5%. Rates and 95% confidence intervals of in-hospital events were death 2% (0.7% to 6.1%), myocardial infarction 3% (1% to 7%), coronary bypass surgery 0% (0% to 2.2%), and intracranial hemorrhage 2% (0.4% to 5.3%). Severe thrombocytopenia was observed in 4% of patients (1.4% to 7.8%) after readministration. Allergic or anaphylactic reactions were not observed. Major bleeding was associated with excessive concomitant antithrombotic therapy. Patients undergoing readministration of abciximab within 2 weeks of first administration experienced a higher incidence of severe thrombocytopenia (12% vs. 2%, p = 0.046). Thus, abciximab remains clinically efficacious when readministered as an adjunct to percutaneous coronary intervention. However, concomitant heparin administration must be carefully monitored and warfarin therapy should be avoided. Vigilant surveillance for thrombocytopenia should be employed. Reduced dosing may be necessary when abciximab is readministered within days of the initial administration.


Subject(s)
Antibodies, Monoclonal/administration & dosage , Coronary Disease/drug therapy , Immunoglobulin Fab Fragments/administration & dosage , Platelet Aggregation Inhibitors/administration & dosage , Abciximab , Aged , Antibodies, Monoclonal/adverse effects , Coronary Angiography , Coronary Disease/diagnostic imaging , Coronary Disease/surgery , Electrocardiography , Female , Humans , Immunoglobulin Fab Fragments/adverse effects , Injections, Intravenous , Intracranial Hemorrhages/chemically induced , Male , Middle Aged , Myocardial Revascularization , Platelet Aggregation Inhibitors/adverse effects , Platelet Glycoprotein GPIIb-IIIa Complex/antagonists & inhibitors , Postoperative Period , Retrospective Studies , Safety , Thrombocytopenia/chemically induced , Treatment Outcome
10.
Am J Cardiol ; 84(12): 1385-90, 1999 Dec 15.
Article in English | MEDLINE | ID: mdl-10606109

ABSTRACT

The MULTI-LINK DUET is the next generation MULTI-LINK stent with modified strut geometry. Safety and efficacy of the MULTI-LINK DUET were evaluated in a prospective multicenter registry and were compared with prior MULTI-LINK stent experience from the ASCENT randomized trial. A total of 270 patients received 302 MULTI-LINK DUET stents and were evaluated using a composite primary end point of major cardiac events (death, Q-wave and non-Q-wave myocardial infarction, and requirement for coronary revascularization) attributable to the target stenosis cumulative to 30 days following enrollment. Quantitative coronary angiography was performed at a mean follow-up of 6 +/- 2 (+/-SD) months. No difference in primary end point or in angiographic restenosis to 6 months was observed between MULTI-LINK DUET and MULTI-LINK experiences. The MULTI-LINK DUET demonstrated improved device and procedural success, less postprocedural in-stent stenosis, larger postprocedural minimal lumen diameter, and fewer postprocedural marginal dissections compared with the MULTI-LINK stent. Multivariate regression modeling identified stent length, diabetes mellitus, poststent minimal lumen diameter, lesion eccentricity, and current smoking as independent predictors of in-stent restenosis. Thus, the MULTI-LINK DUET Registry demonstrates enhanced procedural performance with clinical and angiographic outcomes similar to those previously observed for the MULTI-LINK stent in the ASCENT randomized trial.


Subject(s)
Angioplasty, Balloon, Coronary/instrumentation , Coronary Disease/therapy , Stents , Aged , Cause of Death , Coronary Disease/diagnostic imaging , Coronary Disease/mortality , Equipment Failure Analysis , Female , Follow-Up Studies , Humans , Male , Middle Aged , Myocardial Infarction/mortality , Prospective Studies , Prosthesis Design , Radiography , Survival Rate , Treatment Outcome
11.
Am J Cardiol ; 83(3): 311-6, 1999 Feb 01.
Article in English | MEDLINE | ID: mdl-10072214

ABSTRACT

Angiographic studies have demonstrated that perfusion balloon percutaneous transluminal coronary angioplasty (PTCA) may result in modestly improved luminal gains and fewer major dissections than conventional balloon PTCA. However, intracoronary ultrasound (ICUS), which is more sensitive than angiography in evaluating the incidence, extent, and severity of dissection, was not used. We randomized 48 patients with 54 coronary stenoses to conventional or perfusion balloon PTCA. Four 2-minute inflations were permitted with conventional balloon PTCA. Two 10-minute inflations were allowed with perfusion balloon PTCA. Quantitative coronary angiography and ICUS were performed before and after treatment. In-hospital clinical events were recorded. Conventional and perfusion balloon PTCA achieved similar improvements in lumen diameter (1.25+/-0.51 vs 1.28+/-0.51 mm) and reductions in percent stenosis (-45+/-21% vs -44+/-15%) by quantitative coronary angiography. Comparable gains in lumen diameter (0.62+/-0.39 vs 0.50+/-0.38 mm) and lumen area (2.70+/-1.96 vs 2.05+/-1.52 mm2) were observed on ICUS. Angiography demonstrated similar rates of any dissection (36% vs 21%) and major dissection (12% vs 7%). ICUS identified a similar incidence of any dissection (60% vs 76%) and type II dissection (52% vs 62%). The relative dissection area was also similar (9.2+/-5.6% vs 7.8+/-5.8%). One conventional balloon patient experienced postprocedural chest pain. No patient in either group died, or had myocardial infarction, abrupt closure, or urgent revascularization.


Subject(s)
Angioplasty, Balloon, Coronary , Coronary Disease/diagnostic imaging , Coronary Disease/therapy , Ultrasonography, Interventional , Angioplasty, Balloon, Coronary/mortality , Coronary Angiography , Coronary Disease/mortality , Cross-Over Studies , Female , Follow-Up Studies , Hospital Mortality , Humans , Male , Middle Aged , Prospective Studies , Recurrence , Sensitivity and Specificity , Treatment Outcome , Ultrasonography, Interventional/mortality
12.
J Am Coll Cardiol ; 31(1): 50-6, 1998 Jan.
Article in English | MEDLINE | ID: mdl-9426017

ABSTRACT

OBJECTIVES: The purpose of this study was to evaluate the safety, feasibility, optimal deployment technique and 1-year clinical outcome for the Advanced Cardiovascular Systems (ACS) MultiLink stent. BACKGROUND: Optimal stent deployment assessed by quantitative coronary angiography and intravascular ultrasound (IVUS) is associated with improved clinical outcome. METHODS: Forty-nine consecutive patients with a discrete stenosis in a native coronary artery 3 to 4 mm in diameter were treated with the new, balloon-expandable ACS MultiLink stent. Stent expansion was assessed in all patients using quantitative coronary angiography and serial IVUS imaging after 8-, 12- and 16-atm inflations. Clinical follow-up was obtained at 30 days and 1 year. RESULTS: All 49 patients had successful placement of a MultiLink stent without death, emergency coronary artery bypass graft surgery or Q wave myocardial infarction. After placement of the MultiLink stent, the minimal lumen diameter increased from 1.24 to 2.98 mm (p < 0.001), and diameter stenosis decreased from 61% to 7% (p = 0.001). Minimal lumen cross-sectional area by IVUS increased progressively after 8, 12 and 16 atm (5.6 to 6.8 to 7.4 mm2, respectively, p < 0.001). However, only 64% of stents achieved a lumen/reference area ratio > or = 70%. No adverse clinical events occurred by 30 days, and by 1 year only one patient (2.0%) required revascularization of the stented artery. CONCLUSIONS: Treatment of stenoses in native coronary arteries with the MultiLink stent is associated with a high success rate and a low incidence of adverse events by 1 year, despite the fact that the majority of stents did not meet IVUS-defined criteria for "optimal stenting" derived from first-generation devices.


Subject(s)
Coronary Angiography , Coronary Disease/therapy , Stents , Ultrasonography, Interventional , Aged , Equipment Design , Feasibility Studies , Female , Humans , Male , Middle Aged , Pilot Projects , Treatment Outcome
13.
Curr Opin Cardiol ; 13(4): 232-9, 1998 Jul.
Article in English | MEDLINE | ID: mdl-10091018

ABSTRACT

Intracoronary stenting improves the acute and long-term safety and efficacy of percutaneous coronary interventions by minimizing the risks of abrupt closure and late restenosis. Enhanced designs of new coronary stents will continue to expand the spectrum of coronary anatomy and clinical settings amenable to nonsurgical revascularization. Improvements in deliverability, application to complex lesions, and durability of results are direct effects of improved design characteristics. Future design features may also include incorporating adjunctive therapies such as antithrombotic or antiproliferative agents with stent-based delivery systems. Results of new stent registries and randomized clinical trials are reviewed.


Subject(s)
Biocompatible Materials , Blood Vessel Prosthesis Implantation/instrumentation , Coronary Disease/surgery , Stents , Humans , Prosthesis Design , Randomized Controlled Trials as Topic , Registries/statistics & numerical data , Secondary Prevention , United States
14.
Am J Cardiol ; 80(8): 998-1001, 1997 Oct 15.
Article in English | MEDLINE | ID: mdl-9352967

ABSTRACT

We studied 1,238 patients receiving 1,880 coronary stents. In-hospital outcomes were divided by age into <65 years (n = 747, group 1), 65 to 75 years (n = 326, group 2), and >75 years (n = 165, group 3). Procedural success was 97.2%, 95.1%, and 98.8% in groups 1, 2, and 3, respectively (p = NS). There was 1 death (group 1). Myocardial infarction occurred in 1.2%, 2.8%, and 1.8%, bypass surgery occurred in 0.9%, 1.8%, and 1.2%, and repeat balloon angioplasty in 0.3%, 0.6%, and 0% of patients in groups 1, 2, and 3, respectively (p = NS for all comparisons). Vascular complications occurred in 2.8%, 4.9%, and 6.1% in groups 1, 2, and 3, respectively (p <0.05). Six-month follow-up of patients was divided by age: <65 years (n = 564, group 1); 65 to 75 years (n = 221, group 2); and >75 years (n = 122, group 3). Event-free survival was 94.5%, 90.5%, and 89.3% for groups 1, 2, and 3, respectively (p = NS). Death occurred in 0.4%, 0.5%, and 1.6%; myocardial infarction occurred in 1.2%, 2.3%, and 1.6%, and target vessel revascularization in 4.3%, 8.6%, and 7.4% for groups 1, 2, and 3, respectively (p = NS for all comparisons). Thus, coronary stenting produced favorable in-hospital and 6-month outcomes in all 3 age groups. Age itself should not preclude patients from undergoing coronary stenting.


Subject(s)
Coronary Disease/complications , Coronary Vessels/surgery , Stents/adverse effects , Age Factors , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Retrospective Studies , Survival Rate , Treatment Outcome
15.
J Am Coll Cardiol ; 30(2): 452-8, 1997 Aug.
Article in English | MEDLINE | ID: mdl-9247518

ABSTRACT

OBJECTIVES: The purpose of the study was to describe the configuration, and investigate the mechanisms, of QRS changes occurring during percutaneous transluminal coronary angioplasty (PTCA). BACKGROUND: QRS changes during PTCA have been attributed to both a passive ST segment shift and conduction disturbances (peri-ischemic block). The direct relation between ST segment shift and QRS changes, however, has not been established, and the definition of conduction disturbances remains to be clarified. METHODS: Twelve-lead electrocardiograms (ECGs) were recorded before PTCA, at the end of 2 min of PTCA and after return to baseline values in 29 patients (left anterior descending coronary artery [LAD] in 13 patients, right coronary artery [RCA] in 14 and left circumflex coronary artery in 2). Electrocardiographic complexes before and during PTCA were superimposed to determine the amplitudes of initial, terminal and total QRS deflection; the relations of QRS changes to baseline (TP segment) and ST segment shift; and the duration of QRS and corrected QT intervals. RESULTS. 1) The direction of the initial QRS deflection was unchanged, but changes of its amplitude occurred. 2) Terminal QRS deflection changed in all patients with a ST segment shift > 17% of the R amplitude, and the correlation between the decrease in the S amplitude and ST segment shift was significant (r = 0.9, p < 0.01) in patients with LAD PTCA. Correlation between changes in total QRS amplitude and ST segment shift in patients with RCA PTCA was weaker (r = 0.54, p = 0.056). 3) Transient conduction disturbance manifested by QRS widening in selected leads occurred in 2 of 29 patients. CONCLUSIONS. 1) Changes in terminal QRS deflection during PTCA are proportional to the magnitude of the ST segment shift. 2) Conduction disturbances manifested by increased QRS duration occurred infrequently. We suggest that the term peri-ischemic block be applied only to changes in QRS configuration associated with QRS widening.


Subject(s)
Angioplasty, Balloon, Coronary , Electrocardiography , Heart Conduction System/physiopathology , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged
16.
Clin Cardiol ; 20(2): 153-60, 1997 Feb.
Article in English | MEDLINE | ID: mdl-9034645

ABSTRACT

Catheter balloon angioplasty is a well accepted form of nonsurgical treatment of acutely and chronically obstructed coronary artery vessels. It is also the centerpiece for various new intervention techniques. Their morphologic effects on the site of obstruction has been termed "remodeling." Part VI of this six-part series focuses on atherectomy and restenosis tissue obtained by atherectomy procedures.


Subject(s)
Atherectomy, Coronary/methods , Coronary Disease/therapy , Coronary Vessels/pathology , Graft Occlusion, Vascular/therapy , Saphenous Vein/pathology , Angioplasty, Balloon/methods , Coronary Disease/etiology , Coronary Disease/pathology , Coronary Vessels/transplantation , Graft Occlusion, Vascular/etiology , Graft Occlusion, Vascular/pathology , Humans , Saphenous Vein/transplantation , Treatment Outcome
17.
Clin Cardiol ; 20(1): 67-74, 1997 Jan.
Article in English | MEDLINE | ID: mdl-8994741

ABSTRACT

Catheter balloon angioplasty is a well accepted form of nonsurgical treatment of acutely and chronically obstructed coronary artery vessels. It is also the centerpiece for various new intervention techniques. Their morphologic effect on the site of obstruction has been termed "remodeling." Part V of this six-part series focuses on remodeling effects of balloon angioplasty on obstructed young (< or = 1 year) and old (> 1 year) saphenous vein bypass grafts.


Subject(s)
Angioplasty, Balloon, Coronary , Graft Occlusion, Vascular/therapy , Saphenous Vein/pathology , Arteriosclerosis/pathology , Arteriosclerosis/therapy , Atherectomy , Coronary Artery Bypass , Coronary Disease/pathology , Coronary Disease/therapy , Graft Occlusion, Vascular/pathology , Humans , Recurrence , Saphenous Vein/transplantation , Stents
18.
Am Heart J ; 134(6): 1099-106, 1997 Dec.
Article in English | MEDLINE | ID: mdl-9424071

ABSTRACT

OBJECTIVES: Intracoronary ultrasonography was used to assess coronary arteries before and after balloon percutaneous transluminal coronary angioplasty (PTCA) to determine whether the mode of coronary atherosclerotic remodeling affects the mechanism of balloon dilation. BACKGROUND: Coronary arteries may enlarge or shrink in response to atherosclerotic plaque development. The effect of coronary remodeling on the mechanism of balloon PTCA has not yet been studied. METHODS: Forty-one patients with 47 native de novo coronary artery lesions were studied with a 30 MHz intracoronary ultrasound catheter before and after balloon PTCA. Images were analyzed at the lesion site and the adjacent reference segments. At each site the lumen, vessel, and plaque area and the percent area stenosis were measured. Lesions were separated into two groups based on relative vessel area (lesion vessel area/reference vessel area). A relative vessel area >1.0 defines adaptive enlargement (group 1, n = 25), whereas a relative vessel area < or =1.0 reflects coronary shrinkage (group 2, n = 22). Regression analysis examined whether elastic recoil and the PTCA balloon/vessel area ratio correlated. RESULTS: After balloon PTCA was performed, both the enlargement and shrinkage groups had similar gains in luminal area (2.3 +/- 1.8 mm2 [mean +/- SD] vs 2.8 +/- 1.7 mm2, p = 0.32), reduction in percent stenosis (-19.2% +/- 11.5% vs -14.4 +/- 12.7, p = 0.18), and final lumen area (4.9 +/- 1.7 mm2 vs 4.7 +/- 1.9 mm2, p = 0.73). However, the mechanism of luminal enlargement was different in each group. Reduction in plaque area was significantly greater in the enlargement group (group 1, -2.0 +/- 1.7 mm2 vs group 2, 0.04 +/- 2.2 mm2; p = 0.001), whereas increased vessel area was more important in the shrinkage group (group 1, 0.8 +/- 1.5 mm2 vs group 2, 2.4 +/- 2.3 mm2; p = 0.009). Positive correlation was seen between elastic recoil and the balloon/vessel area ratio in lesions with vessel enlargement (r = 0.80, p < 0.0001). No such correlation was observed in shrinkage vessels (r = 0.28, p = 0.21 ). CONCLUSIONS: The acute luminal gain after balloon PTCA is similar regardless of the type of coronary remodeling. However, the mode of remodeling affects the mechanism of balloon dilation such that enlargement vessels exhibit plaque compression, whereas shrinkage arteries demonstrate vessel stretch. The post-PTCA elastic recoil correlates linearly to the balloon/vessel area ratio in arteries that have undergone adaptive enlargement.


Subject(s)
Angioplasty, Balloon, Coronary , Coronary Artery Disease/pathology , Coronary Artery Disease/therapy , Coronary Vessels/pathology , Constriction, Pathologic , Coronary Artery Disease/diagnostic imaging , Coronary Vessels/diagnostic imaging , Humans , Prospective Studies , Regression Analysis , Ultrasonography, Interventional
19.
Clin Cardiol ; 19(12): 960-6, 1996 Dec.
Article in English | MEDLINE | ID: mdl-8957601

ABSTRACT

Catheter balloon angioplasty is a well accepted form of nonsurgical treatment of acutely and chronically obstructed coronary artery vessels. It is also the centerpiece for various new intervention techniques. Their morphologic effects on the site of obstruction has been termed "remodeling." Part IV of this six-part series focuses on morphologic correlates of coronary angiographic patterns of remodeling after balloon angioplasty and discusses effects of angioplasty on adjacent, nondilated vessels.


Subject(s)
Angioplasty, Balloon/adverse effects , Coronary Angiography , Coronary Vessels/injuries , Coronary Vessels/pathology , Adult , Animals , Humans , Myocardial Infarction/therapy , Myocardial Reperfusion , Rupture , Saphenous Vein/transplantation
20.
Clin Cardiol ; 19(11): 857-68, 1996 Nov.
Article in English | MEDLINE | ID: mdl-8914779

ABSTRACT

While abundant clinical and angiographic data are available regarding features of acute or abrupt closure at the site of balloon angioplasty, little morphologic information is available. This study discusses morphologic-histologic causes for acute closure after angioplasty in 130 necropsy patients. Intimal-medial flaps, elastic recoil, and primary thrombosis were the three leading morphologic causes for closure. Data were subdivided into time categories: abrupt (< 1 day), acute (< 1 week), and early (< 1 month). Intimal-medial flaps remained the most common cause for angioplasty closure despite time from angioplasty to documented occlusion. Morphologic recognition of types and frequencies of angioplasty closure are discussed, and specific mechanical, pharmacologic, or combined treatments are reviewed.


Subject(s)
Angioplasty, Balloon, Coronary , Coronary Disease/pathology , Coronary Vessels/pathology , Adult , Aged , Coronary Disease/etiology , Female , Humans , Male , Middle Aged , Recurrence , Time Factors , Tunica Intima/pathology , Tunica Media/pathology
SELECTION OF CITATIONS
SEARCH DETAIL
...