Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Pain Physician ; 24(5): E631-E638, 2021 08.
Article in English | MEDLINE | ID: mdl-34323451

ABSTRACT

BACKGROUND: There are controversies about the optimal management of AO subtype A3 burst fractures. The most common surgical treatment consists of posterior fixation with pedicle screw and rod augmentation. Nevertheless, a loss of correction in height restoration and kyphotic reduction has been observed. OBJECTIVES: The aim of this study was to assess long-term outcomes of a minimally invasive technique using a percutaneous intravertebral expandable titanium implant (PIETI). STUDY DESIGN: This prospective, single center, pilot study was carried out on a consecutive case series of 44 patients with acute (< 2 weeks) traumatic thoracolumbar fractures AO type A3. The average follow-up was 5.6 years. SETTING: A single center in Castilla y Leon, SpainMETHODS: Clinical outcomes (pain intensity on visual analog scale [VAS], Oswestry Disability Index [ODI], analgesic consumption) and radiographic outcomes (anterior/mid/posterior vertebral body height, vertebral area, local kyphosis angle, traumatic regional angulation) were analyzed before surgery, at one month after surgery, and at the end of the follow-up period. RESULTS: At one-month postsurgery, significant improvements in VAS score and ODI score were observed. PIETI achieved significant vertebral body height restoration with median height increases of 2.9 mm/4.3 mm/2.3 mm for anterior/middle/posterior parts, respectively. Significant correction of the local kyphotic angle and improvement of the traumatic regional angulation were accomplished. All these improvements were maintained throughout the follow-up period. The only complication reported was a case of cement leakage. LIMITATIONS: In our opinion, the main limitation of the study is the small number of patients. However, the sample is superior to that shown in other papers. CONCLUSIONS: This study showed that using a PIETI in the treatment of fractures type A3 is a safe and effective method that allows marked clinical improvement, as well as anatomical vertebral body restoration. Unlike with other treatments, results were maintained over time, allowing a better long-term clinical and functional improvement. The rate of cement leakage was lower than other reports.


Subject(s)
Spinal Fractures , Titanium , Follow-Up Studies , Fracture Fixation, Internal , Humans , Lumbar Vertebrae/diagnostic imaging , Lumbar Vertebrae/injuries , Lumbar Vertebrae/surgery , Pilot Projects , Prospective Studies , Spinal Fractures/surgery , Thoracic Vertebrae/diagnostic imaging , Thoracic Vertebrae/injuries , Thoracic Vertebrae/surgery , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...