1.
Polymers (Basel) ; 15(24)2023 Dec 14.
Article in English | MEDLINE | ID: mdl-38139961

ABSTRACT

The design of musical instruments is a discipline that is still carried out in an artisanal way, with limitations and high costs. With the additive manufacturing technique, it is possible to obtain results for the generation of not only electrical but also acoustic instruments. However, it is necessary to generate a procedure to evaluate the influence of the process on the final result of the acoustics obtained. This study focuses on investigating the relationship between the construction of acoustic guitars and their final sound. The reinforcement structures at the top of the instrument are analysed, as well as how this design affects the vibratory behaviour of the top in the first five vibratory modes. Specifically, this article presents a procedure for the design of customised acoustic guitars using additive manufacturing through parametrisation and a vibrational analysis of the designed tops using finite element (FEA) and experimental physical tests, in order to develop a methodology for the study of stringed instruments. As a result, an 11% increase in the high-frequency response was achieved with a printing direction of +45°, and a reduction in the high-frequency response with ±45°. In addition, at high frequencies, a relative error of 5% was achieved with respect to the simulation. This work fulfils an identified need to study the manufacture of acoustic guitars using polylactic acid (PLA), and to be able to offer the musician a customised instrument. This represents a breakthrough in the use of this manufacturing technology, extending its relationship with product design.

2.
Front Pediatr ; 10: 955553, 2022.
Article in English | MEDLINE | ID: mdl-36160787

ABSTRACT

The objective of this work focuses on the study of the main sources of noise associated with incubators and the acoustic effects that derive from them. The method that has been established is based on tests carried out under different operating conditions of the incubators. Noise levels are analyzed under different boundary conditions (Neonatal ICU and "Controlled environment rooms"). Under normal operating conditions, the levels inside the incubator are around 56 dB (A), values that exceed the maximum limits recommended by the American Academy of Pediatrics. The scope of this study is to evaluate the existing noise levels in the incubator and analyze possible design improvements. The study was carried out in the hospitals of Cádiz, Huelva, and Malaga.

3.
Article in English | MEDLINE | ID: mdl-35162140

ABSTRACT

Environmental legislation in Ecuador is advancing with the legitimate aspiration of providing citizens with new standards of quality and environmental health. In the context of environmental noise, these legislative advances are based on the experience accumulated in other countries, which is an advantage that must be managed with caution by incorporating local factors into noise management procedures. This study advances two lines of work. The first is to survey the population about their attitude towards noise from a major road to try to detect local factors in the annoyance and sleep disturbances. The second uses this information to compare noise indicators for the detection and ranking of hot-spots from major roads. The interviewees exhibited a high level of annoyance and sleep disturbance due to noise compared with the results of other studies. Results show that there are small differences in the definition of hot-spots when using WHO's dose-response curves for Lden ≥ 68 dB for and for Lnight ≥ 58 dB, in comparison with the curves generated in this study (CS). Regarding the application of both dose-response curves (WHO vs. CS) to the estimation of the population at risk of the harmful effect of nighttime traffic noise (HSD), small oscillations are also observed even when Lnight ≥ 58 dB and Lnoche ≥ 60 dB are used.


Subject(s)
Noise, Transportation , Sleep Wake Disorders , Ecuador , Environmental Exposure , Humans , Noise, Transportation/adverse effects , Sleep Wake Disorders/epidemiology , Surveys and Questionnaires
4.
Article in English | MEDLINE | ID: mdl-36613032

ABSTRACT

The acoustic environment has been pointed out as a possible distractor during student activities in the online academic modality; however, it has not been specifically studied, nor has it been studied in relation to parameters frequently used in academic-quality evaluations. The objective of this study is to characterize the acoustic environment and relate it to students' satisfaction with the online learning modality. For that, three artificial neural networks were calculated, using as target variables the students' satisfaction and the noise interference with autonomous and synchronous activities, using acoustic variables as predictors. The data were obtained during the COVID-19 lockdown, through an online survey addressed to the students of the Universidad de Las Américas (Quito, Ecuador). Results show that the noise interference with comprehensive reading or with making exams and that the frequency of noises, which made the students lose track of the lesson, were relevant factors for students' satisfaction. The perceived loudness also had a remarkable influence on engaging in autonomous and synchronous activities. The performance of the models on students' satisfaction and on the noise interference with autonomous and synchronous activities was satisfactory given that it was built only with acoustic variables, with correlation coefficients of 0.567, 0.853, and 0.865, respectively.


Subject(s)
COVID-19 , Education, Distance , Humans , Universities , COVID-19/epidemiology , Communicable Disease Control , Students , Personal Satisfaction
5.
Front Pediatr ; 9: 584736, 2021.
Article in English | MEDLINE | ID: mdl-33898352

ABSTRACT

Low frequency noises are predominant in neonatal intensive care units (NICUs). Some studies affirm that neonates can perceive noises from 113 Hz, and can therefore be affected by sound sources with high spectral content at low frequencies (e.g., incubator engine, air fan). Other studies suggest that reverberation amplifies noise within incubators. In this paper, the reverberation time (T, T 30) within an incubator with standard dimensions was measured in one-third octave bands. To get reliable results, the T was measured in 15 positions at the neonate's ear height, in a room with low T values (to reduce the influence of the room in the results), using an impulsive sound method. Results show a heterogeneous T distribution at the neonate's ear height, with maximum average T differences between positions of 1.07 s. The highest average T of all microphone positions is 2.27 s at 125 Hz, an extremely high mean value for such a small space. As the frequency of electrical devices in America is 60 Hz, some harmonics lay within the one-third octave band of 125 Hz, and therefore may create a very reverberant and inappropriate acoustic environment within the audible spectrum of neonates. As the acoustic environment of the incubator and the room are coupled, it is expected that the results are higher in the NICUs than in the room where the measurements were conducted, as NICUs are more reverberant. Therefore, it is recommended that the T will be limited in the international standards, and that incubator designers take it into account.

6.
Front Pediatr ; 8: 588, 2020.
Article in English | MEDLINE | ID: mdl-33072664

ABSTRACT

The neonatal intensive care unit (NICU) is a very noisy place as compared to the intrauterine environment. To protect the neonate's health, international guidelines suggest avoiding noise levels above 45 dB in NICUs, but this recommendation is not normally met. The incubator acoustic isolation and the acoustic features of the NICU play important roles in determining the noise measured inside the incubator. In this study, the influence of two types of rooms, one with sound-absorbent covering and the other with reverberant surfaces, on the acoustic isolation of a neonatal incubator was evaluated using three acoustic isolation indexes: the level difference, the apparent sound reduction index, and the standardized level difference. Results show that the acoustic isolation of the incubator is very poor, with a level difference below 11 dBA at all frequencies. At 62.5 Hz, the level difference measured in both rooms exhibits a negative value, indicating that the incubator amplifies the noise coming from the NICU. Isolation of the incubator is poor, and the reverberation time (RT) of the containing room influences RT of the incubator, which is consequently higher when the containing room is reverberant; for example, the incubator RT in the reverberant NICU is 0.72 s higher at 500 Hz than that in a room with sound-absorbent covering.

7.
Noise Health ; 19(86): 20-23, 2017.
Article in English | MEDLINE | ID: mdl-28164935

ABSTRACT

INTRODUCTION: One of the problems that the delivery of continuous positive airway pressure (CPAP) via a helmet poses is the generation of noise. The objective of our study was to assess the effect that the use of filter has on sound pressure levels generated by the delivery of positive airway pressure at different gas flow rates. MATERIALS AND METHODS: Sound pressure levels generated by neonatal helmet CPAP delivery were measured at different gas flows (20, 30, and 40 l/min) with and without a breathing filter. Noise intensity was measured by installing microphones in the inner ear of dummy heads wearing helmets. RESULTS: The sound pressure level increased by 38% at a gas flow of 40 l/min, as compared to a gas flow of 20 l/min {74 dBA [interquartile range (IQR) 2,2] vs 52 dBA (IQR 5,9), respectively}. Using the breathing filter as a diffuser has a variety of effects on sound pressure levels according to the gas flow rate. CONCLUSION: The intensity of the noise generated by helmet delivery of positive airway pressure depends on the type of helmet used, gas flow, and use or not of a diffuser filter. Breathing filters with gas flows over 30 l/min might not be recommended since they would not attenuate but will rather amplify sound pressure.