Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 282
Filter
1.
Neurology ; 102(10): e209388, 2024 May 28.
Article in English | MEDLINE | ID: mdl-38701403

ABSTRACT

BACKGROUND AND OBJECTIVES: Whether patent foramen ovale (PFO) closure benefits older patients with PFO and cryptogenic stroke is unknown because randomized controlled trials (RCTs) have predominantly enrolled patients younger than 60 years of age. Our objective was to estimate anticipated effects of PFO closure in older patients to predict the numbers needed to plan an RCT. METHODS: Effectiveness estimates are derived from major observational studies (Risk of Paradoxical Embolism [RoPE] Study and Oxford Vascular Study, together referred to as the "RoPE-Ox" database) and all 6 major RCTs (Systematic, Collaborative, PFO Closure Evaluation [SCOPE] Consortium). To estimate stroke recurrence risk, observed outcomes were calculated for patients older than 60 years in the age-inclusive observational databases (n = 549). To estimate the reduction in the rate of recurrent stroke associated with PFO closure vs medical therapy based on the RoPE score and the presence of high-risk PFO features, a Cox proportional hazards regression model was developed on the RCT data in the SCOPE database (n = 3,740). These estimates were used to calculate sample sizes required for a future RCT. RESULTS: Five-year risk of stroke recurrence using Kaplan-Meier estimates was 13.7 (95% CI 10.5-17.9) overall, 14.9% (95% CI 10.2-21.6) in those with high-risk PFO features. Predicted relative reduction in the event rate with PFO closure was 12.9% overall, 48.8% in those with a high-risk PFO feature. Using these estimates, enrolling all older patients with cryptogenic stroke and PFO would require much larger samples than those used for prior PFO closure trials, but selectively enrolling patients with high-risk PFO features would require totals of 630 patients for 90% power and 471 patients for 80% power, with an average of 5 years of follow-up. DISCUSSION: Based on our projections, anticipated effect sizes in older patients with high-risk features make a trial in these subjects feasible. With lengthening life expectancy in almost all regions of the world, the utility of PFO closure in older adults is increasingly important to explore.


Subject(s)
Feasibility Studies , Foramen Ovale, Patent , Patient Selection , Stroke , Humans , Foramen Ovale, Patent/complications , Foramen Ovale, Patent/surgery , Aged , Stroke/etiology , Male , Female , Middle Aged , Randomized Controlled Trials as Topic , Recurrence , Treatment Outcome , Age Factors , Aged, 80 and over
2.
Article in English | MEDLINE | ID: mdl-38693866

ABSTRACT

AIMS: Evaluation of left and right ventricular longitudinal systolic function may enhance risk stratification following aortic valve replacement (AVR). The study objective was to evaluate the changes in left and right ventricular longitudinal systolic function and RV-pulmonary artery (RV-PA) coupling from baseline to 30-days and 1-year after aortic valve replacement (AVR). METHODS AND RESULTS: LV longitudinal strain (LS), tricuspid annulus plane systolic excursion (TAPSE), and RV-PA coupling were evaluated in patients from the PARTNER-2A surgical AVR (SAVR) arm (n=985) and from the PARTNER-2 SAPIEN-3 registry (n=719). TAPSE and RV-PA coupling decreased significantly following SAVR, but remained stable following TAVR. Lower LV LS, TAPSE, or RV-PA coupling at baseline were associated with increased risk of the composite of death, hospitalization, and stroke at 5-years (Adjusted-HRs for LV LS<15%: 1.24 95%CI 1.05-1.45, p=0.001; TAPSE<14mm: 1.44 95%CI 1.21-1.73, p<0.001; RV/PA coupling<0.55mm/mmHg: 1.32 95% CI 1.07-1.63, p=0.011). Reduced TAPSE at baseline was the most powerful predictor of the composite endpoint at 5-years. Patients with LV ejection fraction <50% at baseline had increased risk of the primary endpoint with SAVR (HR: 1.34, 95%CI 1.08-1.68, p=0.009) but not with TAVR (HR: 1.12, 95%CI 0.88-1.42). Lower RV-PA coupling at 30-days showed the strongest association with cardiac mortality. CONCLUSION: SAVR but not TAVR was associated with a marked deterioration in RV longitudinal systolic function and RV-PA coupling. Lower TAPSE and RV-PA coupling at 30-days were associated with inferior clinical outcomes at 5-years. In patients with LVEF<50%, TAVR was associated with superior 5-year outcomes.

3.
N Engl J Med ; 2024 Apr 07.
Article in English | MEDLINE | ID: mdl-38587261

ABSTRACT

BACKGROUND: Patients with severe aortic stenosis and a small aortic annulus are at risk for impaired valvular hemodynamic performance and associated adverse cardiovascular clinical outcomes after transcatheter aortic-valve replacement (TAVR). METHODS: We randomly assigned patients with symptomatic severe aortic stenosis and an aortic-valve annulus area of 430 mm2 or less in a 1:1 ratio to undergo TAVR with either a self-expanding supraannular valve or a balloon-expandable valve. The coprimary end points, each assessed through 12 months, were a composite of death, disabling stroke, or rehospitalization for heart failure (tested for noninferiority) and a composite end point measuring bioprosthetic-valve dysfunction (tested for superiority). RESULTS: A total of 716 patients were treated at 83 sites in 13 countries (mean age, 80 years; 87% women; mean Society of Thoracic Surgeons Predicted Risk of Mortality, 3.3%). The Kaplan-Meier estimate of the percentage of patients who died, had a disabling stroke, or were rehospitalized for heart failure through 12 months was 9.4% with the self-expanding valve and 10.6% with the balloon-expandable valve (difference, -1.2 percentage points; 90% confidence interval [CI], -4.9 to 2.5; P<0.001 for noninferiority). The Kaplan-Meier estimate of the percentage of patients with bioprosthetic-valve dysfunction through 12 months was 9.4% with the self-expanding valve and 41.6% with the balloon-expandable valve (difference, -32.2 percentage points; 95% CI, -38.7 to -25.6; P<0.001 for superiority). The aortic-valve mean gradient at 12 months was 7.7 mm Hg with the self-expanding valve and 15.7 mm Hg with the balloon-expandable valve, and the corresponding values for additional secondary end points through 12 months were as follows: mean effective orifice area, 1.99 cm2 and 1.50 cm2; percentage of patients with hemodynamic structural valve dysfunction, 3.5% and 32.8%; and percentage of women with bioprosthetic-valve dysfunction, 10.2% and 43.3% (all P<0.001). Moderate or severe prosthesis-patient mismatch at 30 days was found in 11.2% of the patients in the self-expanding valve group and 35.3% of those in the balloon-expandable valve group (P<0.001). Major safety end points appeared to be similar in the two groups. CONCLUSIONS: Among patients with severe aortic stenosis and a small aortic annulus who underwent TAVR, a self-expanding supraannular valve was noninferior to a balloon-expandable valve with respect to clinical outcomes and was superior with respect to bioprosthetic-valve dysfunction through 12 months. (Funded by Medtronic; SMART ClinicalTrials.gov number, NCT04722250.).

4.
Article in English | MEDLINE | ID: mdl-38553277

ABSTRACT

BACKGROUND: Studies comparing transcatheter and surgical aortic valve replacement (TAVR and SAVR) for patients with trileaflet aortic stenosis (AS) have found similar or larger effective orifice area (EOA) for TAVR prostheses. To our knowledge, no studies have compared EOA in patients undergoing TAVR versus SAVR for bicuspid AS. METHODS: We retrospectively compared prosthetic valvular sizing and predicted EOA for patients with bicuspid AS undergoing TAVR or SAVR at our institution between January 1, 2016, and December 31, 2021. We excluded patients undergoing procedures for indications other than AS and those without a pre-procedural gated Chest CT. Comparisons included demographics, comorbidities, annular size, prosthetic valve size, predicted EOA and prosthesis-patient mismatch (PPM) for TAVR (N = 78) and SAVR (N = 74) cohorts. RESULTS: TAVR patients had smaller pre-procedural annular area (501.7 mm2 vs. 571.8 mm2, p < 0.05) and annular perimeter (80.6 mm vs. 86.5 mm, p < 0.05), but larger mean implanted prosthetic valve size (26.4 mm vs 24.2 mm, p < 0.001) compared to SAVR patients. No differences were observed in predicted EOA, predicted EOA indexed to patient body surface area (EOAi), or predicted PPM grade between TAVR and SAVR groups, including in cohorts sorted by pre-procedural annular size. CONCLUSIONS: For bicuspid AS patients undergoing aortic valve replacement, TAVR achieves similar predicted EOA to SAVR. These data support the use of TAVR in selected patients with bicuspid AS and can inform heart team discussions.

5.
Ann Thorac Surg ; 117(6): 1164-1171, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38316377

ABSTRACT

BACKGROUND: Our objective was to compare the impact of patient-prosthesis mismatch (PPM) for 2 years after surgical aortic valve replacement within the prospective, randomized Placement of Aortic Transcatheter Valves (PARTNER) trials. METHODS: Surgical aortic valve replacement patients from the PARTNER 1, 2, and 3 trials were included. PPM was classified as moderate (indexed effective orifice area ≤0.85 cm2/m2) or severe (indexed effective orifice area ≤0.65 cm2/m2). The primary endpoint was the composite of all-cause death and heart failure rehospitalization at 2 years. RESULTS: By the predicted PPM method (PPMP), 59.1% had no PPM, 38.8% moderate PPM, and 2.1% severe PPM; whereas by the measured PPM method (PPMM), 42.4% had no PPM, 36.0% moderate, and 21.6% severe. Patients with no PPMP (23.6%) had a lower rate of the primary endpoint compared with patients with moderate (28.2%, P = .03) or severe PPMP (38.8%, P = .02). Using the PPMM method, there was no difference between the no (17.7%) and moderate PPMM groups (21.1%) in the primary outcome (P = .16). However, those with no PPMM or moderate PPMM were improved compared with severe PPMM (27.4%, P < .001 and P = .02, respectively). CONCLUSIONS: Severe PPM analyzed by PPMP was only 2.1% for surgical aortic valve replacement patients. The PPMM method overestimated the incidence of severe PPM relative to PPMP, but was also associated with worse outcome. There was higher all-cause mortality in patients with severe PPM, thus surgical techniques to minimize PPM remain critical.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Humans , Female , Male , Aged , Aortic Valve Stenosis/surgery , Prospective Studies , Transcatheter Aortic Valve Replacement/methods , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve/surgery , Postoperative Complications/epidemiology , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis Implantation/adverse effects , Prosthesis Design , Aged, 80 and over , Treatment Outcome , Prosthesis Fitting
7.
Eur Heart J ; 44(46): 4862-4873, 2023 Dec 07.
Article in English | MEDLINE | ID: mdl-37930776

ABSTRACT

BACKGROUND AND AIMS: For patients with symptomatic, severe tricuspid regurgitation (TR), early results of transcatheter tricuspid valve (TV) intervention studies have shown significant improvements in functional status and quality of life associated with right-heart reverse remodelling. Longer-term follow-up is needed to confirm sustained improvements in these outcomes. METHODS: The prospective, single-arm, multicentre TRISCEND study enrolled 176 patients to evaluate the safety and performance of transcatheter TV replacement in patients with ≥moderate, symptomatic TR despite medical therapy. Major adverse events, reduction in TR grade and haemodynamic outcomes by echocardiography, and clinical, functional, and quality-of-life parameters are reported to one year. RESULTS: Enrolled patients were 71.0% female, mean age 78.7 years, 88.0% ≥ severe TR, and 75.4% New York Heart Association classes III-IV. Tricuspid regurgitation was reduced to ≤mild in 97.6% (P < .001), with increases in stroke volume (10.5 ± 16.8 mL, P < .001) and cardiac output (0.6 ± 1.2 L/min, P < .001). New York Heart Association class I or II was achieved in 93.3% (P < .001), Kansas City Cardiomyopathy Questionnaire score increased by 25.7 points (P < .001), and six-minute walk distance increased by 56.2 m (P < .001). All-cause mortality was 9.1%, and 10.2% of patients were hospitalized for heart failure. CONCLUSIONS: In an elderly, highly comorbid population with ≥moderate TR, patients receiving transfemoral EVOQUE transcatheter TV replacement had sustained TR reduction, significant increases in stroke volume and cardiac output, and high survival and low hospitalization rates with improved clinical, functional, and quality-of-life outcomes to one year. Funded by Edwards Lifesciences, TRISCEND ClinicalTrials.gov number, NCT04221490.


Subject(s)
Heart Valve Prosthesis Implantation , Tricuspid Valve Insufficiency , Humans , Female , Aged , Male , Tricuspid Valve Insufficiency/epidemiology , Tricuspid Valve Insufficiency/surgery , Tricuspid Valve/surgery , Heart Valve Prosthesis Implantation/methods , Prospective Studies , Quality of Life , Treatment Outcome , Cardiac Catheterization/methods , Severity of Illness Index
8.
N Engl J Med ; 389(21): 1949-1960, 2023 Nov 23.
Article in English | MEDLINE | ID: mdl-37874020

ABSTRACT

BACKGROUND: A previous analysis in this trial showed that among patients with severe, symptomatic aortic stenosis who were at low surgical risk, the rate of the composite end point of death, stroke, or rehospitalization at 1 year was significantly lower with transcatheter aortic-valve replacement (TAVR) than with surgical aortic-valve replacement. Longer-term outcomes are unknown. METHODS: We randomly assigned patients with severe, symptomatic aortic stenosis and low surgical risk to undergo either TAVR or surgery. The first primary end point was a composite of death, stroke, or rehospitalization related to the valve, the procedure, or heart failure. The second primary end point was a hierarchical composite that included death, disabling stroke, nondisabling stroke, and the number of rehospitalization days, analyzed with the use of a win ratio analysis. Clinical, echocardiographic, and health-status outcomes were assessed through 5 years. RESULTS: A total of 1000 patients underwent randomization: 503 patients were assigned to undergo TAVR, and 497 to undergo surgery. A component of the first primary end point occurred in 111 of 496 patients in the TAVR group and in 117 of 454 patients in the surgery group (Kaplan-Meier estimates, 22.8% in the TAVR group and 27.2% in the surgery group; difference, -4.3 percentage points; 95% confidence interval [CI], -9.9 to 1.3; P = 0.07). The win ratio for the second primary end point was 1.17 (95% CI, 0.90 to 1.51; P = 0.25). The Kaplan-Meier estimates for the components of the first primary end point were as follows: death, 10.0% in the TAVR group and 8.2% in the surgery group; stroke, 5.8% and 6.4%, respectively; and rehospitalization, 13.7% and 17.4%. The hemodynamic performance of the valve, assessed according to the mean (±SD) valve gradient, was 12.8±6.5 mm Hg in the TAVR group and 11.7±5.6 mm Hg in the surgery group. Bioprosthetic-valve failure occurred in 3.3% of the patients in the TAVR group and in 3.8% of those in the surgery group. CONCLUSIONS: Among low-risk patients with severe, symptomatic aortic stenosis who underwent TAVR or surgery, there was no significant between-group difference in the two primary composite outcomes. (Funded by Edwards Lifesciences; PARTNER 3 ClinicalTrials.gov number, NCT02675114.).


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/surgery , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/methods , Postoperative Complications/etiology , Risk Factors , Stroke/epidemiology , Stroke/etiology , Stroke/surgery , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome , Follow-Up Studies , Patient Readmission , Heart Failure/etiology
11.
J Am Coll Cardiol ; 82(2): 109-123, 2023 07 11.
Article in English | MEDLINE | ID: mdl-37407110

ABSTRACT

BACKGROUND: Previous studies demonstrated transcatheter aortic valve replacement (TAVR) with an earlier generation balloon-expandable valve to be noninferior to surgical aortic valve replacement (SAVR) for death and disabling stroke in intermediate-risk patients with symptomatic, severe aortic stenosis at 5 years. However, limited long-term data are available with the more contemporary SAPIEN 3 (S3) bioprosthesis. OBJECTIVES: The aim of this study was to compare 5-year risk-adjusted outcomes in intermediate-risk patients undergoing S3 TAVR vs SAVR. METHODS: Propensity score matching was performed to account for baseline differences in intermediate-risk patients undergoing S3 TAVR in the PARTNER 2 (Placement of Aortic Transcatheter Valves) S3 single-arm study and SAVR in the PARTNER 2A randomized clinical trial. The primary composite endpoint consisted of 5-year all-cause death and disabling stroke. RESULTS: A total of 783 matched pairs of intermediate-risk patients with severe aortic stenosis were studied. There were no differences in the primary endpoint between S3 TAVR and SAVR at 5 years (40.2% vs 42.7%; HR: 0.87; 95% CI: 0.74-1.03; P = 0.10). The incidence of mild or greater paravalvular regurgitation was more common after S3 TAVR. There were no differences in structural valve deterioration-related stage 2 and 3 hemodynamic valve deterioration or bioprosthetic valve failure. CONCLUSIONS: In this propensity-matched analysis of intermediate-risk patients, 5-year rates of death and disabling stroke were similar between S3 TAVR and SAVR. Rates of structural valve deterioration-related hemodynamic valve deterioration were similar, but paravalvular regurgitation was more common after S3 TAVR. Longer-term follow-up is needed to further evaluate differences in late adverse clinical events and bioprosthetic valve durability. (PII S3i [PARTNER II Trial: Placement of Aortic Transcatheter Valves II - S3 Intermediate], NCT03222128; PII A (PARTNER II Trial: Placement of Aortic Transcatheter Valves II - XT Intermediate and High Risk], NCT01314313).


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Stroke , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Heart Valve Prosthesis Implantation/adverse effects , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/etiology , Treatment Outcome , Surgical Instruments , Stroke/epidemiology , Stroke/etiology , Stroke/surgery
12.
JACC Cardiovasc Interv ; 16(13): 1626-1635, 2023 07 10.
Article in English | MEDLINE | ID: mdl-37438029

ABSTRACT

BACKGROUND: The latest-generation Evolut FX TAVR system (Medtronic) offers several potential design improvements over its predecessors, but early reported experience has been limited. OBJECTIVES: This study sought to report our multicenter, limited market release, first-in-human experience of transcatheter aortic valve replacement (TAVR) with the Evolut FX system and compare it with a single-center PRO+ (Medtronic) experience. METHODS: From June 27 to September 16, 2022, 226 consecutive patients from 9 US centers underwent transfemoral TAVR with the Evolut FX system for native aortic stenosis (89.4%) or prosthetic valve degeneration (10.6%). Commissural alignment was defined as 0° to 30° between native and FX commissures. Patient, anatomical, and procedural characteristics were retrospectively reviewed, and 30-day clinical and echocardiographic outcomes per Valve Academic Research Consortium-3 definitions were reported. RESULTS: Of 226 patients, 34.1% were low risk, 4% had a bicuspid valve, and 11.5% had a horizontal root (≥60°). Direct Inline sheath (Medtronic) was used in 67.6% and Lunderquist stiff wire (Cook Medical) in 35.4% of cases. Optimal hat marker orientation during deployment was achieved in 98.4%, with commissural alignment in 96.5%. At 30 days, 14.3% mild, 0.9% moderate, and no severe paravalvular leak were observed. Compared with the Evolut PRO+ experience from 1 center, FX had a more symmetrical implantation with shallower depth at the left coronary cusp (P < 0.001), fewer device recaptures (26.1% vs 39.5%; P = 0.004), and improved commissural alignment (96.5% vs 80.2%; P < 0.001). CONCLUSIONS: The Evolut FX system demonstrated favorable 30-day outcomes with a significant improvement over PRO+ in achieving commissural alignment, fewer device recaptures, and more symmetrical implantation. These features may benefit younger patients undergoing TAVR with the supra-annular, self-expanding valve, where lifetime management would be important.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Retrospective Studies , Treatment Outcome , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Catheters
13.
JACC Heart Fail ; 11(10): 1351-1362, 2023 10.
Article in English | MEDLINE | ID: mdl-37480877

ABSTRACT

BACKGROUND: Atrial fibrillation (AF) is a common comorbidity in patients with heart failure with preserved ejection fraction (HFpEF) and in heart failure with mildly reduced ejection fraction (HFmrEF). OBJECTIVES: This study sought to describe AF burden and its clinical impact among individuals with HFpEF and HFmrEF who participated in a randomized clinical trial of atrial shunt therapy (REDUCE LAP-HF II [A Study to Evaluate the Corvia Medical, Inc IASD System II to Reduce Elevated Left Atrial Pressure in Patients with Heart Failure]) and to evaluate the effect of atrial shunt therapy on AF burden. METHODS: Study investigators characterized AF burden among patients in the REDUCE LAP-HF II trial by using ambulatory cardiac patch monitoring at baseline (median patch wear time, 6 days) and over a 12-month follow-up (median patch wear time, 125 days). The investigators determined the association of baseline AF burden with long-term clinical events and examined the effect of atrial shunt therapy on AF burden over time. RESULTS: Among 367 patients with cardiac monitoring data at baseline and follow-up, 194 (53%) had a history of AF or atrial flutter (AFL), and median baseline AF burden was 0.012% (IQR: 0%-1.3%). After multivariable adjustment, baseline AF burden ≥0.012% was significantly associated with heart failure (HF) events (HR: 2.00; 95% CI: 1.17-3.44; P = 0.01) both with and without a history of AF or AFL (P for interaction = 0.68). Adjustment for left atrial reservoir strain attenuated the baseline AF burden-HF event association (HR: 1.71; 95% CI: 0.93-3.14; P = 0.08). Of the 367 patients, 141 (38%) had patch-detected AF during follow-up without a history of AF or AFL. Atrial shunt therapy did not change AF incidence or burden during follow-up. CONCLUSIONS: In HFpEF and HFmrEF, nearly 40% of patients have subclinical AF by 1 year. Baseline AF burden, even at low levels, is associated with HF events. Atrial shunt therapy does not affect AF incidence or burden. (A Study to Evaluate the Corvia Medical, Inc IASD System II to Reduce Elevated Left Atrial Pressure in Patients with Heart Failure [REDUCE LAP-HF II]; NCT03088033).


Subject(s)
Atrial Fibrillation , Heart Failure , Humans , Atrial Fibrillation/epidemiology , Stroke Volume , Heart Atria , Prosthesis Implantation , Prognosis
14.
JAMA Cardiol ; 8(9): 871-878, 2023 09 01.
Article in English | MEDLINE | ID: mdl-37494015

ABSTRACT

Importance: Inadequate representation of older patients, women, and racial minority individuals in cardiovascular clinical trials limits both the generalizability of trial findings and inclusivity in access to novel therapies and therapeutic strategies. Objective: To report on temporal trends in the representation of older patients, women, and racial and ethnic minority individuals in clinical trials studying treatments for valvular heart disease. Evidence Review: All published clinical trials enrolling more than 100 adults with any valvular heart disease published between 2005 and 2020 were included after searches with PubMed and ClinicalTrials.gov. Data on age, sex, race, and ethnicity reported in the included studies were collected. Trials were assigned to 4 time periods based on the publication date, and temporal trends were analyzed in the representation of older patients, women, and racial and ethnic minority individuals. Findings: A total of 139 clinical trials with 51 527 participants were identified. Of these trials, 103 (74%) investigated aortic valve disease and the remainder mitral valve disease. Overall, 63 trials (45.3%) enrolled patients only in Europe, 24 (17.3%) only in North America, and 19 (13.7%) in multiple geographical regions. The weighted mean (SD) age of enrolled patients was 68.4 (11.4) years, increasing nonsignificantly from 61.9 (5.9) years in 2005-2008 to 72.8 (9.6) years in 2017-2020 (P = .09 for trend). The overall proportion of women enrolled in valvular heart disease trials was 41.1%, with no significant changes over time. Data on race and ethnicity of trial participants were reported in 13 trials (9.4%), in which trial-level representation of American Indian/Alaska Native, Asian, Black/African American, Hispanic, and Native Hawaiian/Pacific Islander patients ranged from 0.27% to 43.9%. There were no significant temporal trends noted in the enrollment of racial and ethnic minority populations. The representation of women in clinical trials was positively associated with enrollment rates of older patients and underrepresented racial and ethnic groups. Conclusions and Relevance: This review found that over the past 2 decades, women and racial and ethnic minority individuals have remained underrepresented in North American valvular heart disease clinical trials. Further work is needed to improve the reporting of race and ethnicity data and address barriers to trial enrollment for older patients, women, and racial and ethnic minority individuals.


Subject(s)
Ethnicity , Heart Valve Diseases , Adult , Humans , Female , Aged , Minority Groups , Ethnic and Racial Minorities , Hispanic or Latino
16.
Circulation ; 147(21): 1594-1605, 2023 05 23.
Article in English | MEDLINE | ID: mdl-37154049

ABSTRACT

BACKGROUND: In patients with severe symptomatic aortic stenosis at low surgical risk, transfemoral transcatheter aortic valve replacement (TAVR) with the SAPIEN 3 valve has been shown to reduce the composite of death, stroke, or rehospitalization at 2-year follow-up compared with surgical aortic valve replacement (SAVR). Whether TAVR is cost-effective compared with SAVR for low-risk patients remains uncertain. METHODS: Between 2016 and 2017, 1000 low-risk patients with aortic stenosis were randomly assigned to TAVR with the SAPIEN 3 valve or SAVR in the PARTNER 3 trial (Placement of Aortic Transcatheter Valves). Of these patients, 929 underwent valve replacement, were enrolled in the United States, and were included in the economic substudy. Procedural costs were estimated using measured resource use. Other costs were determined by linkage with Medicare claims or by regression models when linkage was not feasible. Health utilities were estimated using the EuroQOL 5-item questionnaire. With the use of a Markov model informed by in-trial data, lifetime cost-effectiveness from the perspective of the US health care system was estimated in terms of cost per quality-adjusted life-year gained. RESULTS: Although procedural costs were nearly $19 000 higher with TAVR, total index hospitalization costs were only $591 more with TAVR compared with SAVR. Follow-up costs were lower with TAVR such that TAVR led to 2-year cost savings of $2030/patient compared with SAVR (95% CI, -$6222 to $1816) and a gain of 0.05 quality-adjusted life-years (95% CI, -0.003 to 0.102). In our base-case analysis, TAVR was projected to be an economically dominant strategy with a 95% probability that the incremental cost-effectiveness ratio for TAVR would be <$50 000/quality-adjusted life-year gained (consistent with high economic value from a US health care perspective). These findings were sensitive to differences in long-term survival, however, such that a modest long-term survival advantage with SAVR would render SAVR cost-effective (although not cost saving) compared with TAVR. CONCLUSIONS: For patients with severe aortic stenosis and low surgical risk similar to those enrolled in the PARTNER 3 trial, transfemoral TAVR with the SAPIEN 3 valve is cost saving compared with SAVR at 2 years and is projected to be economically attractive in the long run as long as there are no substantial differences in late death between the 2 strategies. Long-term follow-up will be critical to ultimately determine the preferred treatment strategy for low-risk patients from both a clinical and economic perspective.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Transcatheter Aortic Valve Replacement , Humans , Aged , United States , Aortic Valve/surgery , Heart Valve Prosthesis Implantation/methods , Treatment Outcome , Medicare , Transcatheter Aortic Valve Replacement/methods , Risk Factors
17.
JACC Cardiovasc Interv ; 16(8): 927-941, 2023 04 24.
Article in English | MEDLINE | ID: mdl-37100556

ABSTRACT

BACKGROUND: Valve reintervention after transcatheter aortic valve replacement (TAVR) failure has not been studied in detail. OBJECTIVES: The authors sought to determine outcomes of TAVR surgical explantation (TAVR-explant) vs redo-TAVR because they are largely unknown. METHODS: From May 2009 to February 2022, 396 patients in the international EXPLANTORREDO-TAVR registry underwent TAVR-explant (181, 46.4%) or redo-TAVR (215, 54.3%) for transcatheter heart valve (THV) failure during a separate admission from the initial TAVR. Outcomes were reported at 30 days and 1 year. RESULTS: The incidence of reintervention after THV failure was 0.59% with increasing volume during the study period. Median time from index-TAVR to reintervention was shorter in TAVR-explant vs redo-TAVR (17.6 months [IQR: 5.0-40.7 months] vs 45.7 months [IQR: 10.6-75.6 months]; P < 0.001], respectively. TAVR-explant had more prosthesis-patient mismatch (17.1% vs 0.5%; P < 0.001) as the indication for reintervention, whereas redo-TAVR had more structural valve degeneration (63.7% vs 51.9%; P = 0.023), with a similar incidence of ≥moderate paravalvular leak between groups (28.7% vs 32.8% in redo-TAVR; P = 0.44). There was a similar proportion of balloon-expandable THV failures (39.8% TAVR-explant vs 40.5% redo-TAVR; P = 0.92). Median follow-up was 11.3 (IQR: 1.6-27.1 months) after reintervention. Compared with redo-TAVR, TAVR-explant had higher mortality at 30 days (13.6% vs 3.4%; P < 0.001) and 1 year (32.4% vs 15.4%; P = 0.001), with similar stroke rates between groups. On landmark analysis, mortality was similar between groups after 30 days (P = 0.91). CONCLUSIONS: In this first report of the EXPLANTORREDO-TAVR global registry, TAVR-explant had a shorter median time to reintervention, with less structural valve degeneration, more prosthesis-patient mismatch, and similar paravalvular leak rates compared with redo-TAVR. TAVR-explant had higher mortality at 30 days and 1 year, but similar rates on landmark analysis after 30 days.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Treatment Outcome , Risk Factors , Registries , Prosthesis Design
SELECTION OF CITATIONS
SEARCH DETAIL
...