Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 180
Filter
1.
BJUI Compass ; 5(7): 621-635, 2024 Jul.
Article in English | MEDLINE | ID: mdl-39022654

ABSTRACT

Objectives: We aim to compare efficacy and safety of water vapour therapy (Rezum), transurethral needle ablation (TUNA) and transurethral microwave therapy (TUMT) for treating men with moderate to severe benign prostatic hyperplasia (BPH) symptoms. Materials: PubMed/MEDLINE, EMBASE and Cochrane Library were searched from inception to 30 July 2023, followed by reference searching and dual-independent study selection. We analysed only randomized clinical trials. RoB-2, NIH-quality assessment tool and GRADE guidelines were used for quality-of-evidence (QoE) assessment. Relevant prospective studies without a critical risk-of-bias were included. Results: At 12 months, Rezum showed similar efficacy to TUNA and TUMT for improvement in International Prostate Symptoms Score - Rezum versus TUMT: 1.33 points (95% CI: -1.66 to 4.35) favouring TUMT (QoE: Moderate) and Rezum versus TUNA: 0.07 points (95% CI: -3.64 to 3.88) favouring TUNA (QoE: Low). Rezum had similar outcomes to TUNA and TUMT for Maximum Peak-Flow Rate (Qmax): Rezum versus TUMT: 1.05 mL/s (95% CI: -4.88 to 2.82) favouring Rezum (QoE: Low) and Rezum versus TUNA: 0.37 mL/s (95% CI: -4.61 to 4.21) favouring TUNA (QoE: Low). Furthermore, post-void residual volume (PVR) comparisons demonstrated that Rezum was similar, or inferior to other techniques at 12 months - Rezum versus TUMT: 11.20 mL (95% CI: -32.40 to 10.30) favouring TUMT (QoE: Low) and Rezum versus TUNA: 24.10 mL (95% CI: 2.81 to 45.10) favouring TUNA (QoE: Low). Rezum also had a similar surgical retreatment rate with TUMT and TUNA up to 3-years - TUMT versus Rezum RR: 1.21 (95% CI: 0.20 to 15.90) (QoE: Low) and TUNA versus Rezum showed RR: 1.81 (95% CI: 0.2 to 24.60) (QoE: Low). In the first 12 months after treatment, Rezum had a higher rate of serious adverse events (Clavien-Dindo ≥ Grade 3) than TUMT and TUNA. TUMT versus Rezum with RR = 0.53 (95% CI: 0.13 to 3.14) (QoE: Low) and TUNA versus Rezum with RR = 0.38 (95% CI: 0.04 to 3.49) (QoE: Low). Conclusions: Moderate to weak evidence suggests that Rezum is not superior to TUNA and TUMT in all domains studied.

2.
Minerva Urol Nephrol ; 76(4): 436-441, 2024 Aug.
Article in English | MEDLINE | ID: mdl-39051891

ABSTRACT

BACKGROUND: En bloc resection of bladder tumor (ERBT) is an established surgical treatment method for patients with non-muscle invasive bladder cancer (NMIBC) in tumors less than 3 cm. Data regarding the efficacy and safety of ERBT on larger than 3 cm tumors are sparse and its efficacy compared to conventional transurethral resection (TURBT) remains unclear. The aim of this study was to prospectively compare the feasibility, safety and oncological outcomes of laser (Tm-fiber) ERBT and TURBT in patients with primary bladder lesions ≥3 cm. METHODS: A cohort of 45 patients who underwent surgery for primary NMIBC between February 2018 and March 2022 was collected prospectively. There was no randomization. All procedures were performed by two experienced surgeons. Inclusion criteria were as follows: age >18 years, primary Ta or T1 bladder tumor with a diameter of ≥3 cm, no more than 3 tumors and no history of upper tract urothelial carcinoma. Exclusion criteria were carcinoma in situ or invasion into muscle layer (≥T2). ERBT was performed with thulium fiber laser (IPG, Russia). Primary endpoints included efficacy with recurrence-free survival (RFS) at 3, 6 and 12 months. Secondary endpoints were safety parameters, perioperative data and specimen quality (the presence of muscle layer in specimens). RESULTS: Twenty-eight patients underwent laser ERBT and 17 conventional TURBT. The location and size of the tumors were comparable in both groups. The success rate was 93.3% in the ERBT group with two cases of conversion from ERBT to TURBT. Detrusor muscle was present in 92.8% patients in the ERBT group versus 70.5% in the TURBT group (P=0.04). Obturator nerve reflex was observed only in the TURBT group: 17.6% vs. 0.0% (P=0.02). The frequency of other complications was comparable between the two groups. RFS was not statistically different between the two methods at 3 (93.9% vs. 94.1%, P=0.87), 6 (89.3% vs. 82.3%, P=0.5) and 12 months (89.3% vs. 70.6%, P=0.11). CONCLUSIONS: Laser ERBT is a feasible and safe procedure to manage bladder tumors larger than 3 cm. While it seems safer than TURBT, its effect on efficacy remains to be assessed in larger trials.


Subject(s)
Cystectomy , Laser Therapy , Urinary Bladder Neoplasms , Humans , Urinary Bladder Neoplasms/surgery , Urinary Bladder Neoplasms/pathology , Urinary Bladder Neoplasms/radiotherapy , Male , Female , Prospective Studies , Aged , Cystectomy/methods , Laser Therapy/methods , Laser Therapy/adverse effects , Laser Therapy/instrumentation , Middle Aged , Treatment Outcome , Tumor Burden , Feasibility Studies , Urethra/surgery
3.
Eur Urol Focus ; 2024 Jun 18.
Article in English | MEDLINE | ID: mdl-38897872

ABSTRACT

BACKGROUND AND OBJECTIVE: Thulium fiber laser (TFL) emerged as a competitor of holmium:yttrium-aluminum-garnet (Ho:YAG) laser for anatomic enucleation of the prostate (AEEP) in men with lower urinary tract symptoms (LUTS) related to benign prostatic obstruction (BPO). The aim was to compare the surgical outcomes of Ho:YAG and TFL for AEEP. METHODS: A literature search was conducted to identify reports published from inception until January 2024. The Preferred Reporting Items for Systematic Reviews and Meta-analyses guidelines were followed to identify eligible studies. The coprimary outcomes were the postoperative International Prostate Symptom Score (IPSS), IPSS-Quality of Life (IPSS-QoL), and peak urinary flow (Qmax). KEY FINDINGS AND LIMITATIONS: Five studies met our inclusion criteria, and data from 1287 and 1555 patients who underwent AEEP with Ho:YAG (holmium laser enucleation of the prostate [HoLEP]) and TFL (thulium fiber laser enucleation of the prostate [ThuFLEP]), respectively, were reviewed. ThuFLEP was associated with a better IPSS at 3 mo even if the difference was not clinically significant (mean difference [MD] 0.59, 95% confidence interval [CI]: 0.29-0.88; p < 0.001). No difference was found for IPSS at 6-12 mo (p = 0.9), and IPSS-QoL at 3 mo (p = 0.9) and 6-12 mo (p = 0.2). HoLEP was associated with a better Qmax at 3 mo (MD 1.41 ml/s, 95% CI: 0.51-2.30; p = 0.002) and ThuFLEP at 6-12 mo (MD -2.61 ml/s, 95% CI: -4.68 to 0.59; p = 0.01), but the differences were not clinically significant. No difference was found in the major (p = 0.3) and overall (p = 0.3) complication rates. HoLEP was associated with shorter enucleation (MD -11.86, 95% CI: -22.36 to 1.36; p = 0.03) but not total operative time (p = 0.5). CONCLUSIONS AND CLINICAL IMPLICATIONS: The present review provides the most updated evidence on the impact of Ho:YAG and TFL in AEEP, demonstrating that these two energy sources are effective in relieving bothersome LUTS in men with BPO. PATIENT SUMMARY: Thulium fiber laser is a new energy source that can be used safely for performing endoscopic enucleation of the prostate in men with bothersome symptoms associated with benign prostatic enlargement.

4.
Eur Urol Focus ; 2024 04 30.
Article in English | MEDLINE | ID: mdl-38692949

ABSTRACT

5α-Reductase inhibitors (5-ARIs) are widely prescribed for treatment of benign prostatic obstruction and androgenic alopecia. Several studies with controversial findings regarding 5-ARI exposure have been published over a number of years, and concerns were recently raised about the potential risks of depression and suicide associated with 5-ARIs. To investigate this association, we conducted a systematic review of the literature and a meta-analysis. Five studies involving 2213600 patients met our inclusion criteria. We found no statistically significant association between 5-ARI exposure and the risk of depression (adjusted hazard ratio [aHR] 1.30, 95% confidence interval [CI] 0.85-2.00; p = 0.23) or suicide (aHR 1.30, 95% CI 0.65-2.61; p = 0.45). Subgroup analyses for finasteride and dutasteride revealed similar results. When restricting the analysis to patients without a prior diagnosis of depression, we observed similar findings (aHR for suicide 1.00, 95% CI 0.68-1.46; p = 0.98). PATIENT SUMMARY: We reviewed study data for more than two million patients taking drugs called 5α-reductase inhibitors (5-ARIs), which are widely prescribed for urinary problems caused by benign prostate enlargement and for male-pattern hair loss. In a pooled analysis we found no evidence of an association between 5-ARI use and the risk of depression or suicide.

6.
World J Urol ; 42(1): 299, 2024 May 06.
Article in English | MEDLINE | ID: mdl-38710824

ABSTRACT

PURPOSE: The primary aim of the study was to evaluate if en-bloc vs. non en-bloc made a difference to intra-, peri- and post-operative surgical outcomes of anatomical endoscopic enucleation (AEEP) in large (> 80 cc) and very large prostates (> 200 cc). The secondary aim was to determine the influence of energy and instruments used. METHODS: Data of patients with > 80 cc prostate who underwent surgery between 2019 and 2022 were obtained from 16 surgeons across 13 centres in 9 countries. Propensity score matching (PSM) was used to reduce confounding. Logistic regression was performed to evaluate factors associated with postoperative urinary incontinence (UI). RESULTS: 2512 patients were included with 991 patients undergoing en-bloc and 1521 patients undergoing non-en-bloc. PSM resulted in 481 patients in both groups. Total operation time was longer in the en-bloc group (p < 0.001), enucleation time was longer in the non en-bloc group (p < 0.001) but morcellation times were similar (p = 0.054). Overall, 30 day complication rate was higher in the non en-bloc group (16.4% vs. 11.4%; p = 0.032). Rate of late complications (> 30 days) was similar (2.3% vs. 2.5%; p > 0.99). There were no differences in rates of UI between the two groups. Multivariate analysis revealed that age, Qmax, pre-operative, post-void residual urine (PVRU) and total operative time were predictors of UI. CONCLUSIONS: In experienced hands, AEEP in large prostates by the en-bloc technique yields a lower rate of complication and a slightly shorter operative time compared to the non en-bloc approach. However, it does not have an effect on rates of post-operative UI.


Subject(s)
Postoperative Complications , Propensity Score , Prostatectomy , Prostatic Hyperplasia , Humans , Male , Aged , Prostatectomy/methods , Prostatic Hyperplasia/surgery , Middle Aged , Treatment Outcome , Organ Size , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Retrospective Studies , Prostate/surgery , Prostate/pathology , Urinary Incontinence/epidemiology
7.
Aktuelle Urol ; 55(3): 250-254, 2024 Jun.
Article in German | MEDLINE | ID: mdl-38653465

ABSTRACT

In En-Bloc Resection of Bladder Tumours (ERBT), tumours are not removed in fragments, but are dissected in one layer and, if possible, extracted in one piece. This method represents a significant shift in the surgical management of non-muscle-invasive bladder tumours, providing multiple benefits over the traditional transurethral resection of the bladder (TUR-B). The histological analysis of ERBT specimens is more accurate, enhancing diagnostic precision. Additionally, the presence of detrusor muscle in ERBT specimens is more frequent, indicating a more complete removal of the tumours. Recent years have seen the consolidation of a robust evidence base emphasizing the advantages of ERBT. Notably, a multicentric, prospective randomized trial has recently revealed a significant reduction in recurrence rates at 12 months follow-up compared with TUR-B. Experienced endourologists should explore this technique, as it may soon become the standard of care. The technique's elegance and effectiveness make it too important to be ignored.


Subject(s)
Cystectomy , Urinary Bladder Neoplasms , Urinary Bladder Neoplasms/surgery , Urinary Bladder Neoplasms/pathology , Humans , Cystectomy/methods , Urinary Bladder/surgery , Urinary Bladder/pathology , Neoplasm Recurrence, Local/surgery , Cystoscopy
8.
Eur Urol Open Sci ; 63: 38-43, 2024 May.
Article in English | MEDLINE | ID: mdl-38558764

ABSTRACT

Background: The use of the new thulium fiber laser in enucleation of the prostate (ThuFLEP) has been introduced recently. Objective: To evaluate complications and urinary incontinence (UI) after ThuFLEP in small and large prostate volume (PV). Design setting and participants: We retrospectively reviewed patients who underwent ThuFLEP in six centers (from January 2020 to January 2023). The exclusion criteria were concomitant lower urinary tract surgery, previous prostate/urethral surgery, prostate cancer, and pelvic radiotherapy. Outcome measurements and statistical analysis: Patients were divided into two groups: group 1: PV ≤80 ml; group 2: PV >80 ml. Univariable and multivariable logistic regression analyses were performed to evaluate the independent predictors of overall UI. Results and limitations: There were 1458 patients in group 1 and 1274 in group 2. There was no significant difference in age. The median PV was 60 (61-72) ml in group 1 and 100 (90-122) ml in group 2. En bloc enucleation was employed more in group 1, while the early apical release technique was used more in group 2. The rate of prolonged irrigation for hematuria, urinary tract infection, and acute urinary retention did not differ significantly. Blood transfusion rate was significantly higher in group 2 (0.5% vs 2.0%, p = 0.001). There was no significant difference in the overall UI rate (12.3% in group 1 vs 14.7% in group 2, p = 0.08). A multivariable regression analysis showed that preoperative postvoiding urine residual (odds ratio 1.004, 95% confidence interval 1.002-1.007, p < 0.01) was the only factor significantly associated with higher odds of UI. A limitation of this study was its retrospective nature. Conclusions: Complications and UI rates following ThuFLEP were similar in patients with a PV up to or larger than 80 ml except for the blood transfusion rate that was higher in the latter. Patient summary: In this study, we looked at outcomes after thulium fiber laser in enucleation of the prostate stratified by PV. We found that blood transfusion was higher in men with PV >80 ml, but urinary incontinence was similar.

9.
Article in English | MEDLINE | ID: mdl-38615071

ABSTRACT

BACKGROUND: The surgical landscape for Lower Urinary Tract Symptoms (LUTS) and Benign Prostatic Hyperplasia (BPH) has evolved with the introduction of Minimally Invasive Surgical Therapies (MISTs), recognizing the impact of sexual function on patients' well-being, and prioritizing ejaculation-sparing approaches. METHODS: This systematic review explored ejaculation sparing after classic endoscopic procedures and MISTs (iTind, Rezum, Urolift, Aquablation, and TPLA) and a literature search yielded 41 studies. RESULTS: While all procedures demonstrated efficacy in improving LUTS/BPH symptoms (IPSS, QoL, Qmax), a subset of studies evaluated ejaculatory function. Positive outcomes were noted, challenging the historical association of BPH surgeries with ejaculatory dysfunction. Variations in study design, patient cohorts, and limited long-term data present challenges. Notably, the lack of baseline specificity, use of alpha-blockers, and non-specific sexual function assessments underscore potential biases. CONCLUSIONS: Despite limitations, the review tentatively concluded that MISTs, including iTind, Rezum, Urolift, Aquablation, and TPLA, appear comparable in sparing ejaculation. Long-term studies are essential to validate sustainability, and comparative research should assess trade-offs between MISTs and traditional surgeries. Incorporating patient-reported outcomes and quality of life assessments will enhance future investigations, refining MISTs as standard therapeutic options for LUTS/BPH.

10.
Curr Opin Urol ; 34(4): 286-293, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38595170

ABSTRACT

PURPOSE OF REVIEW: Surgical treatment of benign prostatic hyperplasia (BPH) carries a significant risk of ejaculation dysfunction. Preservation of antegrade ejaculation while providing effective, well tolerated, and durable treatment of BPH is a paramount component of physical and sexual well being for significant number of men. We reviewed available literature with an aim of providing status on antegrade ejaculation preserving BPH surgical therapies. RECENT FINDINGS: Minimally invasive surgical therapies for BPH have been developed over the last decade, with significant marketing emphasis on their potential for preservation of antegrade ejaculation. However, the question about durability of relief of bladder outlet obstruction remains. Parallel to this technological development, the understanding of anatomical structures involved in ejaculation have resulted in technical modifications of well established surgical treatments modalities like transurethral resection of prostate, endoscopic enucleation of prostate and simple prostatectomy, thereby providing safe and durable relief of bladder outlet obstruction secondary to BPH with a satisfactory preservation of antegrade ejaculation. SUMMARY: Preservation of antegrade ejaculation is an important goal for significant number of men needing BPH surgery. Novel minimally invasive surgical technologies have been developed for this purpose; but understanding of the anatomical structures essential for antegrade ejaculation have allowed technical modification of existing surgical techniques with excellent preservation of antegrade ejaculation.


Subject(s)
Ejaculation , Prostatectomy , Prostatic Hyperplasia , Humans , Prostatic Hyperplasia/surgery , Prostatic Hyperplasia/complications , Male , Prostatectomy/methods , Prostatectomy/adverse effects , Organ Sparing Treatments/methods , Organ Sparing Treatments/adverse effects , Treatment Outcome , Urination/physiology , Sexual Dysfunction, Physiological/etiology , Sexual Dysfunction, Physiological/prevention & control , Sexual Dysfunction, Physiological/physiopathology , Urinary Bladder Neck Obstruction/surgery , Urinary Bladder Neck Obstruction/etiology , Urinary Bladder Neck Obstruction/physiopathology , Transurethral Resection of Prostate/methods , Transurethral Resection of Prostate/adverse effects , Minimally Invasive Surgical Procedures/methods , Minimally Invasive Surgical Procedures/adverse effects
11.
Urology ; 187: 154-161, 2024 May.
Article in English | MEDLINE | ID: mdl-38467289

ABSTRACT

OBJECTIVE: To evaluate outcomes after laser endoscopic enucleation of the prostate (EEP) stratified by whether early apical release (EAR) was performed or not. METHODS: We retrospectively reviewed patients with clinical benign prostatic hyperplasia who underwent EEP with holmium or thulium fiber laser in 8 centers (January 2020-January 2022). EXCLUSION CRITERIA: previous prostate/urethral surgery, prostate cancer, pelvic radiotherapy, concomitant lower urinary tract surgery. One-to-one propensity score-matching was performed between patients with EAR vs no EAR, with covariates including age, prostate volume, diabetes mellitus, hypertension, preoperative indwelling catheter, IPSS, Qmax, enucleation, and laser types. Multivariable logistic regression analyses were performed to evaluate independent predictors of 30-day postoperative complications and urinary incontinence. RESULTS: EAR was performed in 2094 of 4392 included patients. The matched cohort consisted of 787 patients per arm. Total operation time was significantly longer in the EAR group (median 75 vs 67 minutes, P = .004). Early complications were higher in the EAR group (18.6% vs 12.5%, P = .001), while postoperative incontinence rates were similar (14.1% vs 13.1%, P = .61). Multivariable regression analysis showed that 3-lobe enucleation and operation time were significant predictors of postoperative complications; preoperative indwelling catheterization, higher prostate volume, and en-bloc enucleation were associated with higher odds of postoperative incontinence. LIMITATION: retrospective nature. CONCLUSION: Performing EAR during EEP is associated with a greater incidence of early complications, which was mainly driven by higher rates of postoperative hematuria and perioperative transfusion. The risk of postoperative incontinence and its duration are not affected by EAR.


Subject(s)
Postoperative Complications , Prostatic Hyperplasia , Humans , Male , Prostatic Hyperplasia/surgery , Retrospective Studies , Aged , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Middle Aged , Treatment Outcome , Prostatectomy/methods , Prostatectomy/adverse effects , Endoscopy/methods , Endoscopy/adverse effects , Urinary Incontinence/etiology , Urinary Incontinence/epidemiology , Lasers, Solid-State/therapeutic use , Laser Therapy/methods , Laser Therapy/adverse effects , Time Factors
12.
Prostate Int ; 12(1): 40-45, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38523902

ABSTRACT

Background: Endoscopic enucleation of the prostate (EEP) has gained acceptance as an equitable alternative to transurethral resection of the prostate for benign prostate hyperplasia (BPH). Our primary aim is to compare peri-operative outcomes of EEP using thulium fiber laser (TFL) against high-power holmium laser (HPHL) in hands of experienced surgeons for large prostates (≥80 ml in volume). Secondary outcomes were assess complications within 1 year of follow up. Materials and Methods: We retrospectively reviewed patients with benign prostatic hyperplasia who underwent EEP with TFL or HPHL in 13 centers (January 2019-January 2023). Patients with prostate volume ≥80 ml were included, while those with concomitant prostate cancer, previous prostate/urethral surgery, and pelvic radiotherapy were excluded. Results: Of 1,929 included patients, HPHL was utilized in 1,459 and TFL in 470. After propensity score matching (PSM) for baseline characteristics, 247 patients from each group were analyzed. Overall operative time (90 [70, 120] vs. 52.5 [39, 93] min, P < 0.001) and enucleation time (90 [70, 105] vs. 38 [25, 70] min, P < 0.001) were longer in the TFL group, with comparable morcellation time (13 [10, 19.5] vs. 13 [10, 16.5] min, P = 0.914). In terms of postoperative outcomes, there were no differences in 30-day complications such as acute urinary retention, urinary tract infection or sepsis. In the PSM cohort, univariable analyses showed that higher age, lower preoperative Qmax, higher preoperative PVRU, and longer operation time were associated with higher odds of postoperative incontinence, while 2-lobe enucleation had lower odds of incontinence compared to 3-lobe enucleation. Conclusions: This real-world study reaffirms that HPHL and TFL in large prostates are equally efficacious in terms of 30-day complications. TFL with the en-bloc technique has a shorter operative time which significantly improves short- and medium-term functional outcomes.

13.
World J Urol ; 42(1): 180, 2024 Mar 20.
Article in English | MEDLINE | ID: mdl-38507108

ABSTRACT

PURPOSE: To evaluate complications and urinary incontinence (UI) after endoscopic enucleation of the prostate (EEP) stratified by prostate volume (PV). METHODS: We retrospectively reviewed patients with benign prostatic hyperplasia who underwent EEP with different energy sources in 14 centers (January 2019-January 2023). INCLUSION CRITERIA: prostate volume ≥ 80 ml. EXCLUSION CRITERIA: prostate cancer, previous prostate/urethral surgery, pelvic radiotherapy. PRIMARY OUTCOME: complication rate. SECONDARY OUTCOMES: incidence of and factors affecting postoperative UI. Patients were divided into 3 groups. Group 1: PV = 80-100 ml; Group 2 PV = 101-200 ml; Group 3 PV > 200 ml. Multivariable logistic regression analysis was performed to evaluate independent predictors of overall incontinence. RESULTS: There were 486 patients in Group 1, 1830 in Group 2, and 196 in Group 3. The most commonly used energy was high-power Holmium laser followed by Thulium fiber laser in all groups. Enucleation, morcellation, and total surgical time were significantly longer in Group 2. There was no significant difference in overall 30-day complications and readmission rates. Incontinence incidence was similar (12.1% in Group 1 vs. 13.2% in Group 2 vs. 11.7% in Group 3, p = 0.72). The rate of stress and mixed incontinence was higher in Group 1. Multivariable regression analysis showed that age (OR 1.019 95% CI 1.003-1.035) was the only factor significantly associated with higher odds of incontinence. CONCLUSIONS: PV has no influence on complication and UI rates following EEP. Age is risk factor of postoperative UI.


Subject(s)
Laser Therapy , Lasers, Solid-State , Prostatic Hyperplasia , Transurethral Resection of Prostate , Urinary Incontinence , Male , Humans , Prostate/surgery , Retrospective Studies , Incidence , Laser Therapy/methods , Urinary Incontinence/epidemiology , Urinary Incontinence/etiology , Urinary Incontinence/surgery , Prostatic Hyperplasia/surgery , Prostatic Hyperplasia/complications , Transurethral Resection of Prostate/adverse effects , Transurethral Resection of Prostate/methods , Lasers, Solid-State/adverse effects , Treatment Outcome
14.
Urologie ; 63(3): 295-302, 2024 Mar.
Article in German | MEDLINE | ID: mdl-38376761

ABSTRACT

In the acute diagnostics of a suspected nephroureterolithiasis, ultrasonography should be the examination modality of choice. In cases of suspected urolithiasis, unclear flank pain with fever or in cases of a solitary kidney, a noncontrast computed tomography (CT) scan should always subsequently be performed. If the sonography findings are inconclusive in pregnant women a magnetic resonance imaging (MRI) examination can be considered. If there are indications for urinary diversion, a retrograde imaging study should be performed as part of the urinary diversion. This or CT imaging is also suitable for preinterventional imaging before shock wave lithotripsy, percutaneous nephrolithotomy or ureteroscopy. Postinterventional imaging is not always necessary and sonography is often sufficient. In a conservative treatment approach an abdominal plain X­ray can be used for follow-up assessment.


Subject(s)
Kidney Calculi , Urinary Diversion , Urolithiasis , Humans , Female , Pregnancy , Kidney Calculi/diagnostic imaging , Urolithiasis/therapy , Tomography, X-Ray Computed , Ureteroscopy/methods
15.
World J Urol ; 42(1): 79, 2024 Feb 14.
Article in English | MEDLINE | ID: mdl-38353743

ABSTRACT

PURPOSE: To identify laser settings and limits applied by experts during laser vaporization (vapBT) and laser en-bloc resection of bladder tumors (ERBT) and to identify preventive measures to reduce complications. METHODS: After a focused literature search to identify relevant questions, we conducted a survey (57 questions) which was sent to laser experts. The expert selection was based on clinical experience and scientific contribution. Participants were asked for used laser types, typical laser settings during specific scenarios, and preventive measures applied during surgery. Settings for a maximum of 2 different lasers for each scenario were possible. Responses and settings were compared among the reported laser types. RESULTS: Twenty-three of 29 (79.3%) invited experts completed the survey. Thulium fiber laser (TFL) is the most common laser (57%), followed by Holmium:Yttrium-Aluminium-Garnet (Ho:YAG) (48%), continuous wave (cw) Thulium:Yttrium-Aluminium-Garnet (Tm:YAG) (26%), and pulsed Tm:YAG (13%). Experts prefer ERBT (91.3%) to vapBT (8.7%); however, relevant limitations such as tumor size, number, and anatomical tumor location exist. Laser settings were generally comparable; however, we could find significant differences between the laser sources for lateral wall ERBT (p = 0.028) and standard ERBT (p = 0.033), with cwTm:YAG and pulsed Tm:YAG being operated in higher power modes when compared to TFL and Ho:YAG. Experts prefer long pulse modes for Ho:YAG and short pulse modes for TFL lasers. CONCLUSION: TFL seems to have replaced Ho:YAG and Tm:YAG. Most laser settings do not differ significantly among laser sources. For experts, continuous flow irrigation is the most commonly applied measure to reduce complications.


Subject(s)
Aluminum , Thulium , Urinary Bladder Neoplasms , Yttrium , Humans , Thulium/therapeutic use , Urinary Bladder Neoplasms/surgery , Lasers , Technology
16.
BJUI Compass ; 5(2): 189-206, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38371212

ABSTRACT

Background: Although holmium laser enucleation (HoLEP) is considered a size-independent procedure for treatment of an enlarged prostate, prostate artery embolization (PAE) is emerging as an alternative modality to treat moderate and large benign prostatic hyperplasia. This study aims to compare the early post-operative and short-term efficacy of PAE and HoLEP. Methods: PubMed, Cochrane Library and EMBASE databases were searched. Network meta-analysis was performed following PRISMA-N-guidelines. Post-operative parameters analysed include international prostate symptom score (IPSS), quality of life (QOL), post-void residual urine (PVR), maximal uroflow rate (Qmax) and serious adverse events (SAE). Random effects model calculated weighted mean differences (WMD). If 95%CI crossed the line of no effect (WMD = 0), evidence indicated no statistically significant difference between treatments compared. Results: Qualitative and quantitative syntheses included 20 and 18 studies with 1991 and 1606 patients, respectively. At 3 months, there was no statistically significant difference between PAE and HoLEP in IPSS score improvement [WMD: -2.21: 95%CI: (-10.20, 5.78), favouring PAE], QoL score improvement [WMD: -0.22:95%CI: (-1.75, 1.32), favouring PAE] and PVR improvement [WMD: 26.97: 95%CI: (-59.53, 113.48), favouring HoLEP]. However, PAE was found inferior to HoLEP for Qmax improvement [WMD: 8.47, 95%CI: (2.89, 14.05), favouring HoLEP]. At 1-year follow-up, there was no statistically significant was found between PAE and HoLEP for IPSS score improvement [WMD:6.03, 95%CI: (-1.30, 13.35)], QoL score improvement [WMD: 0.03, 95%CI: (-1.19, 1.25)], PVR improvement [WMD:4.11, 95%CI: (-32.31, 40.53)] and Qmax improvement [WMD:2.60, 95%CI: (-2.20, 7.41)] with all differences favouring HoLEP. PAE was superior to HoLEP for SAE [PAE vs. HoLEP-OR: 0.68, 95%CI: (0.25, 1.37)]. Conclusion: HoLEP was superior to PAE at 3 months for Qmax improvement. There was no significant difference in IPSS, QoL, PVR and Qmax improvement at 1 year between PAE and HoLEP. PAE was also associated with lesser SAE compared to HoLEP. Studies on the long-term outcome of PAE are needed to establish the durability of early outcomes after PAE.

17.
World J Urol ; 42(1): 35, 2024 Jan 13.
Article in English | MEDLINE | ID: mdl-38217727

ABSTRACT

PURPOSE: Past decade has seen a renewed interest in minimally invasive surgical techniques (MISTs) for management of enlarged prostate. This narrative review aims to explore newer MIST for benign prostatic hyperplasia (BPH) which are not yet integrated into established societal guidelines. METHODS: We conducted a literature search across PubMed, Google Scholar, and FDA ClinicalTrials.gov databases on June 1st, 2023, to identify studies published within the past decade exploring various MISTs for BPH. Additionally, we gathered insights from abstracts presented in meetings of professional associations and corporate websites. We broadly classified these procedures into three distinct categories: energy-based, balloon dilation, and implant/stent treatments. We collected detail information about the device, procedure details, its inclusion and exclusion criteria, and outcome. RESULTS: Our review reveals that newer energy-based MISTs include Transperineal Laser Ablation, Transurethral Ultrasound Ablation, and High-Intensity Focused Ultrasound. In the sphere of balloon dilation, Transurethral Columnar Balloon Dilation and the Optilume BPH Catheter System were gaining momentum. The noteworthy implants/stents that are on horizon include Butterfly Prostatic Retraction Device, Urocross Expander System, Zenflow Spring System, and ProVee Urethral Expander System. CONCLUSION: The exploration of various MISTs reflects ongoing efforts to enhance patient care and address limitations of existing treatments. This review provides a bird-eye view and valuable insights for urologists and researchers seeking to navigate the dynamic landscape of MISTs in the quest for effective and minimally invasive solutions for enlarged prostates.


Subject(s)
Prostatic Hyperplasia , Transurethral Resection of Prostate , Male , Humans , Prostatic Hyperplasia/surgery , Prostate/surgery , Transurethral Resection of Prostate/methods , Prostatectomy/methods , Minimally Invasive Surgical Procedures , Stents
18.
World J Urol ; 42(1): 33, 2024 Jan 13.
Article in English | MEDLINE | ID: mdl-38217743

ABSTRACT

PURPOSE: To identify laser lithotripsy settings used by experts for specific clinical scenarios and to identify preventive measures to reduce complications. METHODS: After literature research to identify relevant questions, a survey was conducted and sent to laser experts. Participants were asked for preferred laser settings during specific clinical lithotripsy scenarios. Different settings were compared for the reported laser types, and common settings and preventive measures were identified. RESULTS: Twenty-six laser experts fully returned the survey. Holmium-yttrium-aluminum-garnet (Ho:YAG) was the primary laser used (88%), followed by thulium fiber laser (TFL) (42%) and pulsed thulium-yttrium-aluminum-garnet (Tm:YAG) (23%). For most scenarios, we could not identify relevant differences among laser settings. However, the laser power was significantly different for middle-ureteral (p = 0.027), pelvic (p = 0.047), and lower pole stone (p = 0.018) lithotripsy. Fragmentation or a combined fragmentation with dusting was more common for Ho:YAG and pulsed Tm:YAG lasers, whereas dusting or a combination of dusting and fragmentation was more common for TFL lasers. Experts prefer long pulse modes for Ho:YAG lasers to short pulse modes for TFL lasers. Thermal injury due to temperature development during lithotripsy is seriously considered by experts, with preventive measures applied routinely. CONCLUSIONS: Laser settings do not vary significantly between commonly used lasers for lithotripsy. Lithotripsy techniques and settings mainly depend on the generated laser pulse's and generator settings' physical characteristics. Preventive measures such as maximum power limits, intermittent laser activation, and ureteral access sheaths are commonly used by experts to decrease thermal injury-caused complications.


Subject(s)
Aluminum , Lasers, Solid-State , Lithotripsy, Laser , Urolithiasis , Yttrium , Humans , Thulium , Urolithiasis/surgery , Lithotripsy, Laser/methods , Lasers, Solid-State/therapeutic use , Technology , Holmium
19.
Eur Urol Focus ; 10(1): 154-168, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37442721

ABSTRACT

CONTEXT: Controversy exists regarding the therapeutic benefit of suction use during percutaneous nephrolithotripsy (PCNL). OBJECTIVE: To review and highlight the options available in the use of suction for PCNL, and to discuss their strengths and limitations. EVIDENCE ACQUISITION: A systematic literature search was performed using Scopus, EMBASE, and PubMed. Thirty four studies were included. There was one ex vivo study. Among clinical studies, 24 used a vacuum/suctioning sheath and nine a handpiece suction device/direct-in-scope suction. The suction technique was employed in standard, mini-PCNL, supermini-PCNL, and enhanced supermini­PCNL techniques. EVIDENCE SYNTHESIS: Handpiece suction devices demonstrated better safety and efficiency in treating large stones than nonsuction PCNL and in a much shorter time. Trilogy and ShockPulse-SE were equally effective, safe, and versatile for standard PCNL and mini-PCNL. The heavier handpiece makes Trilogy less ergonomically friendly. Laser suction handpiece devices can potentiate laser lithotripsy by allowing for better laser control with simultaneous suction of small fragments and dust. Integrated suction-based sheaths are available in reusable and disposable forms for mini-PCNL only. Mini-PCNL with suction reported superior outcomes for operative time and stone-free rate to mini-PCNL. This also helped minimize infectious complications by a combination of intrarenal pressure reduction and faster aspiration of irrigation fluid reducing the risk of sepsis, enhance intraoperative vision, and improve lithotripsy efficiency, which makes it a very attractive evolution for PCNL. CONCLUSIONS: Suction devices in PCNL are reforming the way PCNL is being done. Adding suction to mini-PCNL reduces infectious complications and improves the stone-free rate. Our review shows that despite the limited evidence, suction techniques appear to improve PCNL outcomes. PATIENT SUMMARY: In this review, we looked at the intra- and perioperative outcomes of percutaneous nephrolithotripsy (PCNL) with the addition of suction. With better stone fragmentation and fewer postoperative infections, this technology is very useful particularly for mini-PCNL.


Subject(s)
Kidney Calculi , Lithotripsy, Laser , Lithotripsy , Humans , Kidney Calculi/surgery , Suction , Postoperative Complications/therapy
SELECTION OF CITATIONS
SEARCH DETAIL
...