Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Clin Neurophysiol ; 128(8): 1524-1531, 2017 08.
Article in English | MEDLINE | ID: mdl-28501415

ABSTRACT

OBJECTIVE: To investigate the effect of systematic electrode reduction from a common 10-20 EEG system on pattern detection sensitivity (SEN). METHODS: Two reviewers rated 17130 one-minute segments of 83 prospectively recorded cEEGs according to the ACNS standardized critical care EEG terminology (CCET), including burst suppression patterns (BS) and unequivocal electrographic seizures. Consensus annotations between reviewers were used as a gold standard to determine pattern detection SEN and specificity (SPE) of a computational algorithm (baseline, 19 electrodes). Electrodes were than reduced one by one in four different variations. SENs and SPEs were calculated to determine the most beneficial assembly with respect to the number and location of electrodes. RESULTS: High automated baseline SENs (84.99-93.39%) and SPEs (90.05-95.6%) were achieved for all patterns. Best overall results in detecting BS and CCET patterns were found using the "hairline+vertex" montage. While the "forehead+behind ear" montage showed an advantage in detecting ictal patterns, reaching a 15% drop of SEN with 10 electrodes, all montages could detect BS sufficiently if at least nine electrodes were available. CONCLUSION: For the first time an automated approach was used to systematically evaluate the effect of electrode reduction on pattern detection SEN in cEEG. SIGNIFICANCE: Prediction of the expected detection SEN of specific EEG patterns with reduced EEG montages in ICU patients.


Subject(s)
Computational Biology/methods , Electroencephalography/instrumentation , Electroencephalography/methods , Intensive Care Units , Databases, Factual/trends , Delta Rhythm/physiology , Electrodes , Humans , Intensive Care Units/trends , Prospective Studies
2.
Clin Neurophysiol ; 128(6): 1000-1007, 2017 06.
Article in English | MEDLINE | ID: mdl-28458027

ABSTRACT

OBJECTIVE: To assess whether ICU caregivers can correctly read and interpret continuous EEG (cEEG) data displayed with the computer algorithm NeuroTrend (NT) with the main attention on seizure detection and determination of sedation depth. METHODS: 120 screenshots of NT (480h of cEEG) were rated by 18 briefly trained nurses and biomedical analysts. Multirater agreements (MRA) as well as interrater agreements (IRA) compared to an expert opinion (EXO) were calculated for items such as pattern type, pattern location, interruption of recording, seizure suspicion, consistency of frequency, seizure tendency and level of sedation. RESULTS: MRA as well as IRA were almost perfect (80-100%) for interruption of recording, spike-and-waves, rhythmic delta activity and burst suppression. A substantial agreement (60-80%) was found for electrographic seizure patterns, periodic discharges and seizure suspicion. Except for pattern localization (70.83-92.26%), items requiring a precondition and especially those who needed interpretation like consistency of frequency (47.47-79.15%) or level of sedation (41.10%) showed lower agreements. CONCLUSIONS: The present study demonstrates that NT might be a useful bedside monitor in cases of subclinical seizures. Determination of correct sedation depth by ICU caregivers requires a more detailed training. SIGNIFICANCE: Computer algorithms may reduce the workload of cEEG analysis in ICU patients.


Subject(s)
Critical Care/methods , Electroencephalography/instrumentation , Neurophysiological Monitoring/instrumentation , Point-of-Care Systems , Seizures/diagnosis , Software , Adult , Attitude of Health Personnel , Electroencephalography/methods , Humans , Intensive Care Units , Middle Aged , Neurophysiological Monitoring/methods , Nurse Specialists/psychology , Nurse Specialists/standards
3.
Neurophysiol Clin ; 45(3): 203-13, 2015 Sep.
Article in English | MEDLINE | ID: mdl-26363685

ABSTRACT

AIMS OF THE STUDY: Continuous EEG from critical care patients needs to be evaluated time efficiently to maximize the treatment effect. A computational method will be presented that detects rhythmic and periodic patterns according to the critical care EEG terminology (CCET) of the American Clinical Neurophysiology Society (ACNS). The aim is to show that these detected patterns support EEG experts in writing neurophysiological reports. MATERIALS AND METHODS: First of all, three case reports exemplify the evaluation procedure using graphically presented detections. Second, 187 hours of EEG from 10 critical care patients were used in a comparative trial study. For each patient the result of a review session using the EEG and the visualized pattern detections was compared to the original neurophysiology report. RESULTS: In three out of five patients with reported seizures, all seizures were reported correctly. In two patients, several subtle clinical seizures with unclear EEG correlation were missed. Lateralized periodic patterns (LPD) were correctly found in 2/2 patients and EEG slowing was correctly found in 7/9 patients. In 8/10 patients, additional EEG features were found including LPDs, EEG slowing, and seizures. CONCLUSION: The use of automatic pattern detection will assist in review of EEG and increase efficiency. The implementation of bedside surveillance devices using our detection algorithm appears to be feasible and remains to be confirmed in further multicenter studies.


Subject(s)
Critical Care/standards , Electroencephalography/standards , Terminology as Topic , Algorithms , Automation , Brain Abscess/diagnosis , Computer Graphics , Female , Humans , Middle Aged , Stroke/diagnosis , User-Computer Interface
4.
Epilepsy Behav ; 49: 286-9, 2015 Aug.
Article in English | MEDLINE | ID: mdl-25982266

ABSTRACT

BACKGROUND: Continuous EEG (cEEG) is necessary to document nonconvulsive seizures (NCS), nonconvulsive status epilepticus (NCSE), as well as rhythmic and periodic EEG patterns of 'ictal-interictal uncertainty' (RPPIIU) including periodic discharges, rhythmic delta activity, and spike-and-wave complexes in neurological intensive care patients. However, cEEG is associated with significant recording and analysis efforts. Therefore, predictors from short-term routine EEG with a reasonably high yield are urgently needed in order to select patients for evaluation with cEEG. OBJECTIVE: The aim of this study was to assess the prognostic significance of early epileptiform discharges (i.e., within the first 30 min of EEG recording) on the following: (1) incidence of ictal EEG patterns and RPPIIU on subsequent cEEG, (2) occurrence of acute convulsive seizures during the ICU stay, and (3) functional outcome after 6 months of follow-up. METHODS: We conducted a separate analysis of the first 30 min and the remaining segments of prospective cEEG recordings according to the ACNS Standardized Critical Care EEG Terminology as well as NCS criteria and review of clinical data of 32 neurological critical care patients. RESULTS: In 17 patients with epileptiform discharges within the first 30 min of EEG (group 1), electrographic seizures were observed in 23.5% (n = 4), rhythmic or periodic EEG patterns of 'ictal-interictal uncertainty' in 64.7% (n = 11), and neither electrographic seizures nor RPPIIU in 11.8% (n = 2). In 15 patients with no epileptiform discharges in the first 30 min of EEG (group 2), no electrographic seizures were recorded on subsequent cEEG, RPPIIU were seen in 26.7% (n = 4), and neither electrographic seizures nor RPPIIU in 73.3% (n = 11). The incidence of EEG patterns on cEEG was significantly different between the two groups (p = 0.008). Patients with early epileptiform discharges developed acute seizures more frequently than patients without early epileptiform discharges (p = 0.009). Finally, functional outcome six months after discharge was significantly worse in patients with early epileptiform discharges (p=0.01). CONCLUSIONS: Epileptiform discharges within the first 30 min of EEG recording are predictive for the occurrence of ictal EEG patterns and for RPPIIU on subsequent cEEG, for acute convulsive seizures during the ICU stay, and for a worse functional outcome after 6 months of follow-up. This article is part of a Special Issue entitled Status Epilepticus.


Subject(s)
Electroencephalography/drug effects , Epilepsy/drug therapy , Seizures/drug therapy , Status Epilepticus/drug therapy , Critical Care , Delta Rhythm/drug effects , Epilepsy/epidemiology , Epilepsy/physiopathology , Female , Humans , Incidence , Male , Middle Aged , Predictive Value of Tests , Prognosis , Prospective Studies , Seizures/epidemiology , Seizures/physiopathology , Status Epilepticus/epidemiology , Status Epilepticus/physiopathology , Treatment Outcome , Uncertainty
5.
Epilepsy Behav ; 49: 273-9, 2015 Aug.
Article in English | MEDLINE | ID: mdl-26004320

ABSTRACT

BACKGROUND: NeuroTrend is a computational method that analyzes long-term scalp EEGs in the ICU according to ACNS standardized critical care EEG terminology (CCET) including electrographic seizures. At present, it attempts to become a screening aid for continuous EEG (cEEG) recordings in the ICU to facilitate the review process and optimize resources. METHODS: A prospective multicenter study was performed in two neurological ICUs including 68 patients who were subjected to video-cEEG. Two reviewers independently annotated the first minute of each hour in the cEEG according to CCET. These segments were also screened for faster patterns with frequencies higher than 4 Hz. The matching annotations (2911 segments) were then used as gold standard condition to test sensitivity and specificity of the rhythmic and periodic pattern detection of NeuroTrend. RESULTS: Interrater agreement showed substantial agreement for localization (main term 1) and pattern type (main term 2) of the CCET. The overall detection sensitivity of NeuroTrend was 94% with high detection rates for periodic discharges (PD = 80%) and rhythmic delta activity (RDA = 82%). Overall specificity was moderate (67%) mainly because of false positive detections of RDA in cases of general slowing. In contrast, a detection specificity of 88% for PDs was reached. Localization revealed only a slight agreement between reviewers and NeuroTrend. CONCLUSIONS: NeuroTrend might be a suitable screening tool for cEEG in the ICU and has the potential to raise efficiency of long-term EEG monitoring in the ICU. At this stage, pattern localization and differentiation between RDA and general slowing need improvement. This article is part of a Special Issue entitled "Status Epilepticus".


Subject(s)
Critical Care/methods , Electroencephalography/methods , Electroencephalography/statistics & numerical data , Adult , Aged , Artifacts , Data Interpretation, Statistical , Delta Rhythm , False Positive Reactions , Female , Humans , Intensive Care Units , Male , Middle Aged , Observer Variation , Prospective Studies , Reference Standards , Sensitivity and Specificity , Status Epilepticus/diagnosis , Status Epilepticus/therapy
SELECTION OF CITATIONS
SEARCH DETAIL
...