1.
Rev Sci Instrum ; 91(2): 023701, 2020 Feb 01.
Article in English | MEDLINE | ID: mdl-32113420

ABSTRACT

We present a stability investigation of the Stockholm laboratory cryo soft x-ray microscope. The microscope operates at a wavelength of 2.48 nm and can image biological samples at liquid-nitrogen temperatures in order to mitigate radiation damage. We measured the stability of the two most critical components, sample holder and optics holder, in vacuo and at cryo temperatures at both short and long time scales with a fiber interferometer. Results revealed vibrations in the kHz range, originating mainly from a turbo pump, as well as long term drifts in connection with temperature fluctuations. With improvements in the microscope, earlier stability issues vanished and close-to diffraction-limited imaging could be achieved. Moreover, our investigation shows that fiber interferometers are a powerful tool in order to investigate position-sensitive setups at the nanometer level.

2.
Phys Rev Lett ; 112(25): 253903, 2014 Jun 27.
Article in English | MEDLINE | ID: mdl-25014818

ABSTRACT

We report on the observation and application of near-field speckles with a laboratory x-ray source. The detection of speckles is possible thanks to the enhanced brilliance properties of the used liquid-metal-jet source, and opens the way to a range of new applications in laboratory-based coherent x-ray imaging. Here, we use the speckle pattern for multimodal imaging of demonstrator objects. Moreover, we introduce algorithms for phase and dark-field imaging using speckle tracking, and we show that they yield superior results with respect to existing methods.

3.
Phys Med Biol ; 59(11): 2801-11, 2014 Jun 07.
Article in English | MEDLINE | ID: mdl-24801363

ABSTRACT

We show that the microvasculature of mouse tumors can be visualized using propagation-based phase-contrast x-ray imaging with gas as the contrast agent. The large density difference over the gas-tissue interface provides high contrast, allowing the imaging of small-diameter blood vessels with relatively short exposure times and low dose using a compact liquid-metal-jet x-ray source. The method investigated is applied to tumors (E1A/Ras-transformed mouse embryonic fibroblasts) grown in mouse ears, demonstrating sub-15-µm-diameter imaging of their blood vessels. The exposure time for a 2D projection image is a few seconds and a full tomographic 3D map takes some minutes. The method relies on the strength of the vasculature to withstand the gas pressure. Given that tumor vessels are known to be more fragile than normal vessels, we investigate the tolerance of the vasculature of 12 tumors to gas injection and find that a majority withstand 200 mbar pressures, enough to fill 12-µm-diameter vessels with gas. A comparison of the elasticity of tumorous and non-tumorous vessels supports the assumption of tumor vessels being more fragile. Finally, we conclude that the method has the potential to be extended to the imaging of 15 µm vessels in thick tissue, including mouse imaging, making it of interest for, e.g., angiogenesis research.


Subject(s)
Angiography/methods , Carbon Dioxide , Contrast Media , Animals , Ear Neoplasms/blood supply , Ear Neoplasms/diagnostic imaging , Imaging, Three-Dimensional , Injections , Mice
4.
Opt Express ; 21(25): 30183-95, 2013 Dec 16.
Article in English | MEDLINE | ID: mdl-24514597

ABSTRACT

We present a comparison for high-resolution imaging with a laboratory source between grating-based (GBI) and propagation-based (PBI) x-ray phase-contrast imaging. The comparison is done through simulations and experiments using a liquid-metal-jet x-ray microfocus source. Radiation doses required for detection in projection images are simulated as a function of the diameter of a cylindrical sample. Using monochromatic radiation, simulations show a lower dose requirement for PBI for small object features and a lower dose for GBI for larger object features. Using polychromatic radiation, such as that from a laboratory microfocus source, experiments and simulations show a lower dose requirement for PBI for a large range of feature sizes. Tested on a biological sample, GBI shows higher noise levels than PBI, but its advantage of quantitative refractive index reconstruction for multi-material samples becomes apparent.


Subject(s)
Algorithms , Radiographic Image Enhancement/methods , Radiographic Image Interpretation, Computer-Assisted/methods , X-Ray Diffraction/methods
5.
Opt Lett ; 37(21): 4425-7, 2012 Nov 01.
Article in English | MEDLINE | ID: mdl-23114317

ABSTRACT

Laboratory water window cryomicroscopy has recently demonstrated similar image quality as synchrotron-based microscopy but still with much longer exposure times, prohibiting the spread to a wider scientific community. Here we demonstrate high-resolution laboratory water window imaging of cryofrozen cells with 10 s range exposure times. The major improvement is the operation of a λ=2.48 nm, 2 kHz liquid nitrogen jet laser plasma source with high spatial and temporal stability at high average brightness >1.5×10(12) ph/(s×sr×µm(2)×line), i.e., close to that of early synchrotrons. Thus, this source enables not only biological x-ray microscopy in the home laboratory but potentially other applications previously only accessible at synchrotron facilities.


Subject(s)
Cryopreservation , Microscopy/methods , Water , B-Lymphocytes/cytology , Humans , Time Factors , X-Rays
6.
Phys Med Biol ; 57(22): 7431-41, 2012 Nov 21.
Article in English | MEDLINE | ID: mdl-23093393

ABSTRACT

X-ray in-line phase contrast has recently been combined with CO(2) angiography for high-resolution small-animal vascular imaging at low radiation dose. In this paper we further investigate the potential and limitations of this method and demonstrate observation of vessels down to 8 µm in diameter, considerably smaller than the 60 µm previously reported. Our in-line phase-contrast imaging system is based on a liquid-metal-jet-anode x-ray source and utilizes free-space propagation to convert phase shifts, caused by refractive index variations, into intensity differences. Enhanced refractive index variations are obtained through injection of CO(2) gas into the vascular system to replace the blood. We show rat-kidney images with blood vessels down to 27 µm in diameter and mouse-ear images with vessels down to 8 µm. The minimum size of observable blood vessels is found to be limited by the penetration of gas into the vascular system and the signal-to-noise ratio, i.e. the allowed dose. The diameters of vessels being gas-filled depend on the gas pressure and follow a simple model based on surface tension. A theoretical signal-to-noise comparison shows that this method requires 1000 times less radiation dose than conventional iodine-based absorption contrast for observing sub-50 µm vessels.


Subject(s)
Angiography/methods , Carbon Dioxide , Contrast Media , Animals , Ear/blood supply , Kidney/blood supply , Mice , Rats
7.
Opt Express ; 20(16): 18362-9, 2012 Jul 30.
Article in English | MEDLINE | ID: mdl-23038387

ABSTRACT

We present a laser plasma based x-ray microscope for the water window employing a high-average power laser system for plasma generation. At 90 W laser power a brightness of 7.4 x 10(11) photons/(s x sr x µm(2)) was measured for the nitrogen Lyα line emission at 2.478 nm. Using a multilayer condenser mirror with 0.3 % reflectivity 10(6) photons/(µm(2) x s) were obtained in the object plane. Microscopy performed at a laser power of 60 W resolves 40 nm lines with an exposure time of 60 s. The exposure time can be further reduced to 20 s by the use of new multilayer condenser optics and operating the laser at its full power of 130 W.

8.
Phys Med Biol ; 57(9): 2603-17, 2012 May 07.
Article in English | MEDLINE | ID: mdl-22505599

ABSTRACT

We demonstrate a laboratory method for imaging small blood vessels using x-ray propagation-based phase-contrast imaging and carbon dioxide (CO(2)) gas as a contrast agent. The limited radiation dose in combination with CO(2) being clinically acceptable makes the method promising for small-diameter vascular visualization. We investigate the possibilities and limitations of the method for small-animal angiography and compare it with conventional absorption-based x-ray angiography. Photon noise in absorption-contrast imaging prevents visualization of blood vessels narrower than 50 µm at the highest radiation doses compatible with living animals, whereas our simulations and experiments indicate the possibility of visualizing 20 µm vessels at radiation doses as low as 100 mGy. Experimental computed tomography of excised rat kidney shows blood vessels of diameters down to 60 µm with improved image quality compared to absorption-based methods. With our present prototype x-ray source, the acquisition time for a tomographic dataset is approximately 1 h, which is long compared to the 1-20 min common for absorption-contrast micro-CT systems. Further development of the liquid-metal-jet microfocus x-ray sources used here and high-resolution x-ray detectors shows promise to reduce exposure times and make this high-resolution method practical for imaging of living animals.


Subject(s)
Angiography/methods , Carbon Dioxide , Contrast Media , X-Ray Microtomography/methods , Absorption , Animals , Blood Vessels/anatomy & histology , Imaging, Three-Dimensional , Kidney/blood supply , Models, Biological , Radiation Dosage , Rats
9.
J Struct Biol ; 177(2): 267-72, 2012 Feb.
Article in English | MEDLINE | ID: mdl-22119891

ABSTRACT

Lens-based water-window X-ray microscopy allows two- and three-dimensional (2D and 3D) imaging of intact unstained cells in their near-native state with unprecedented contrast and resolution. Cryofixation is essential to avoid radiation damage to the sample. Present cryo X-ray microscopes rely on synchrotron radiation sources, thereby limiting the accessibility for a wider community of biologists. In the present paper we demonstrate water-window cryo X-ray microscopy with a laboratory-source-based arrangement. The microscope relies on a λ=2.48-nm liquid-jet high-brightness laser-plasma source, normal-incidence multilayer condenser optics, 30-nm zone-plate optics, and a cryo sample chamber. We demonstrate 2D imaging of test patterns, and intact unstained yeast, protozoan parasites and mammalian cells. Overview 3D information is obtained by stereo imaging while complete 3D microscopy is provided by full tomographic reconstruction. The laboratory microscope image quality approaches that of the synchrotron microscopes, but with longer exposure times. The experimental image quality is analyzed from a numerical wave-propagation model of the imaging system and a path to reach synchrotron-like exposure times in laboratory microscopy is outlined.


Subject(s)
Imaging, Three-Dimensional/methods , Microscopy/methods , B-Lymphocytes/cytology , Cells, Cultured , Cryopreservation , Diplomonadida/cytology , Humans , Saccharomyces cerevisiae/cytology , X-Rays
10.
Rev Sci Instrum ; 82(12): 123701, 2011 Dec.
Article in English | MEDLINE | ID: mdl-22225218

ABSTRACT

We present a high-brightness 24-keV electron-impact microfocus x-ray source based on continuous operation of a heated liquid-indium/gallium-jet anode. The 30-70 W electron beam is magnetically focused onto the jet, producing a circular 7-13 µm full width half maximum x-ray spot. The measured spectral brightness at the 24.2 keV In K(α) line is 3 × 10(9) photons∕(s × mm(2) × mrad(2) × 0.1% BW) at 30 W electron-beam power. The high photon energy compared to existing liquid-metal-jet sources increases the penetration depth and allows imaging of thicker samples. The applicability of the source in the biomedical field is demonstrated by high-resolution imaging of a mammography phantom and a phase-contrast angiography phantom.


Subject(s)
Diagnostic Imaging/methods , Gallium/chemistry , Indium/chemistry , Angiography , Hot Temperature , Mammography , Phantoms, Imaging , X-Rays
11.
Rev Sci Instrum ; 79(1): 016102, 2008 Jan.
Article in English | MEDLINE | ID: mdl-18248074

ABSTRACT

We demonstrate a high-brightness compact 9 keV electron-impact microfocus x-ray source based on a liquid-gallium-jet anode. A approximately 30 W, 50 kV electron gun is focused onto the approximately 20 ms, 30 mum diameter liquid-gallium-jet anode to produce an approximately 10 microm full width at half maximum x-ray spot. The peak spectral brightness is >2 x 10(10) photons(s mm(2) mrad(2)x0.1% BW). Calculation and experiments show potential for increasing this brightness by approximately three orders of magnitude, making the source suitable for laboratory-scale x-ray crystallography and hard x-ray microscopy.


Subject(s)
Electrons , Gallium/radiation effects , Synchrotrons/instrumentation , Equipment Design , Equipment Failure Analysis , Reproducibility of Results , Sensitivity and Specificity , Solutions , X-Rays
12.
J Microsc ; 226(Pt 2): 175-81, 2007 May.
Article in English | MEDLINE | ID: mdl-17444946

ABSTRACT

We demonstrate compact full-field soft X-ray transmission microscopy with sub 60-nm resolution operating at lambda= 2.48 nm. The microscope is based on a 100-Hz regenerative liquid-nitrogen-jet laser-plasma source in combination with a condenser zone plate and a micro-zone plate objective for high-resolution imaging onto a 2048 x 2048 pixel CCD detector. The sample holder is mounted in a helium atmosphere and allows imaging of both dry and wet specimens. The microscope design enables fast sample switching and the sample can be pre-aligned using a visible-light microscope. High-quality images can be acquired with exposure times of less than 5 min. We demonstrate the performance of the microscope using both dry and wet samples.


Subject(s)
Microscopy/methods , Animals , COS Cells , Chlorocebus aethiops , Diatoms/ultrastructure , Equipment Design , Microscopy/instrumentation , X-Rays
13.
J Microsc ; 226(Pt 1): 71-3, 2007 Apr.
Article in English | MEDLINE | ID: mdl-17381711

ABSTRACT

Soft X-ray microscopy is a powerful tool for investigations of, for example, polymers or soils in their natural liquid environment. This requires a wet-specimen chamber. Compact X-ray microscopy allows the horizontal mounting of such samples, thereby reducing the influence of gravitational forces. We have developed a wet-specimen chamber for such compact X-ray microscope. The chamber is vacuum compatible, which reduces the exposure time. The vacuum sealing is achieved by a combination of mechanical sealing and sealing by bio-compatible glue. With the wet-specimen chamber the specimens can be kept in an aqueous environment in a vacuum of 10(-4) mbar for several hours. Imaging of lipid droplets in water demonstrates the function of the wet-specimen chamber.

14.
J Microsc ; 225(Pt 1): 80-7, 2007 Jan.
Article in English | MEDLINE | ID: mdl-17286697

ABSTRACT

Colloidal gold is a useful marker for functional-imaging experiments in transmission X-ray microscopy. Due to the low contrast of gold particles with small diameters it is necessary to develop a powerful algorithm to localize the single gold particles. The presented image-analysis algorithm for identifying colloidal gold particles is based on the combination of a threshold with respect to the local absorption and shape discrimination, realized by fitting a Gaussian profile to the identified regions of interest. The shape discrimination provides the possibility of size-selective identification and localization of single colloidal gold particles down to a diameter of 50 nm. The image-analysis algorithm, therefore, has potential for localization studies of several proteins simultaneously and for localization of fiducial markers in X-ray tomography.

15.
Ultrasound Med Biol ; 33(1): 145-51, 2007 Jan.
Article in English | MEDLINE | ID: mdl-17189057

ABSTRACT

Ultrasonic-standing-wave (USW) technology has potential to become a standard method for gentle and contactless cell handling in microfluidic chips. We investigate the viability of adherent cells exposed to USWs by studying the proliferation rate of recultured cells following ultrasonic trapping and aggregation of low cell numbers in a microfluidic chip. The cells form 2-D aggregates inside the chip and the aggregates are held against a continuous flow of cell culture medium perpendicular to the propagation direction of the standing wave. No deviations in the doubling time from expected values (24 to 48 h) were observed for COS-7 cells held in the trap at acoustic pressure amplitudes up to 0.85 MPa and for times ranging between 30 and 75 min. Thus, the results demonstrate the potential of ultrasonic standing waves as a tool for gentle manipulation of low cell numbers in microfluidic systems.


Subject(s)
Cells/diagnostic imaging , Ultrasonics , Animals , COS Cells , Cell Adhesion , Cell Proliferation , Cell Survival , Cells/cytology , Chlorocebus aethiops , Microfluidic Analytical Techniques/methods , Microscopy, Confocal , Microscopy, Fluorescence , Ultrasonography
16.
Lab Chip ; 6(10): 1279-92, 2006 Oct.
Article in English | MEDLINE | ID: mdl-17102841

ABSTRACT

Ultrasonic radiation forces can be used for non-intrusive manipulation and concentration of suspended micrometer-sized particles. For bioanalytical purposes, standing-wave ultrasound has long been used for rapid immuno-agglutination of functionalized latex beads. More recently, detection methods based on laser-scanning fluorometry and single-step homogeneous bead-based assays show promise for fast, easy and sensitive biochemical analysis. If such methods are combined with ultrasonic enhancement, detection limits in the femtomolar region are feasible. In this paper, we review the development of standing-wave ultrasonic manipulation for bioanalysis, with special emphasis on miniaturization and ultrasensitive bead-based immunoassays.


Subject(s)
Immunoassay , Microfluidic Analytical Techniques , Microspheres , Sonication , Latex Fixation Tests , Sensitivity and Specificity
17.
Lab Chip ; 6(12): 1537-44, 2006 Dec.
Article in English | MEDLINE | ID: mdl-17203158

ABSTRACT

Several cell-based biological applications in microfluidic systems require simultaneous high-throughput and individual handling of cells or other bioparticles. Available chip-based tools for contactless manipulation are designed for either high-precision handling of individual particles, or high-throughput handling of ensembles of particles. In order to simultaneously perform both, we have combined two manipulation technologies based on ultrasonic standing waves (USWs) and dielectrophoresis (DEP) in a microfluidic chip. The principle is based on the competition between long-range ultrasonic forces, short-range dielectrophoretic forces and viscous drag forces from the fluid flow. The ultrasound is coupled into the microchannel resonator by an external transducer with a refractive element placed on top of the chip, thereby allowing transmission light microscopy to continuously monitor the biological process. The DEP manipulation is generated by an electric field between co-planar microelectrodes placed on the bottom surface of the fluid channel. We demonstrate flexible and gentle elementary manipulation functions by the use of USWs and linear or curved DEP deflector elements that can be used in high-throughput biotechnology applications of individual cells.


Subject(s)
Electrophoresis, Microchip/instrumentation , Electrophoresis, Microchip/methods , Microfluidic Analytical Techniques/instrumentation , Microfluidic Analytical Techniques/methods , Ultrasonics , Equipment Design , Equipment Failure Analysis , Microfluidics/instrumentation , Microfluidics/methods , Particle Size , Sensitivity and Specificity
18.
J Microsc ; 211(Pt 2): 154-60, 2003 Aug.
Article in English | MEDLINE | ID: mdl-12887709

ABSTRACT

Compact water-window X-ray microscopy with short exposure times will always be limited on photons owing to sources of limited power in combination with low-efficency X-ray optics. Thus, it is important to investigate methods for improving the signal-to-noise ratio in the images. We show that a wavelet-based denoising procedure significantly improves the quality and contrast in compact X-ray microscopy images. A non-decimated, discrete wavelet transform (DWT) is applied to original, noisy images. After applying a thresholding procedure to the finest scales of the DWT, by setting to zero all wavelet coefficients of magnitude below a prescribed value, the inverse DWT to the thresholded DWT produces denoised images. It is concluded that the denoising procedure has potential to reduce the exposure time by a factor of 2 without loss of relevant image information.


Subject(s)
Image Enhancement/methods , Microscopy/instrumentation , Microscopy/methods , X-Rays , Algorithms , Artifacts , Diatoms/ultrastructure , Microscopy, Electron, Scanning , Signal Processing, Computer-Assisted
19.
Ultrasonics ; 41(4): 329-33, 2003 Jun.
Article in English | MEDLINE | ID: mdl-12782268

ABSTRACT

We combine ultrasonic trapping and capillary electrophoresis (CE) with the goal to detect ultra-low concentrations of proteins via size-selective separation and enrichment of antibody-coated latex spheres. An 8.5 MHz standing ultrasonic wave is longitudinally coupled into the sub-100- micro m diam capillary of the CE system. Competition between acoustic and viscous forces result in in-flow separation of micro m-diam spheres according to their size. Experiments separating 2.8- and 2.1- micro m-diam fluorescent latex particles, which model a protein-specific immunocomplex/free particle mixture, indicate a potential improvement of the concentration limit of detection of 10(4) compared to current CE systems. Theoretical calculations show room for further improvement.


Subject(s)
Electrophoresis, Capillary , Ultrasonics , Humans , Latex , Microspheres
20.
Electrophoresis ; 22(12): 2384-90, 2001 Aug.
Article in English | MEDLINE | ID: mdl-11519940

ABSTRACT

A system for detection of trace amounts of protein was developed. Two different monoclonal antibodies against human chorionic gonadotropin (hCG) were covalently bound to latex particles. When the latex particles were mixed with a sample containing hCG, a latex-protein-latex complex (immunocomplex) was formed. The complex was separated from the single latex particles using capillary electrophoresis and detected using UV-Vis detection. Limit of detection was 8 amol hCG. The separation was also monitored in real time using laser induced fluorescence - charge coupled device (LIF-CCD) imaging detection. However, a limitation of the method is the restriction to detection of proteins for which monoclonal antibodies are available.


Subject(s)
Chorionic Gonadotropin/analysis , Electrophoresis, Capillary/methods , Antibodies, Monoclonal/immunology , Antigen-Antibody Complex/analysis , Chorionic Gonadotropin/immunology , Fluorometry , Humans , Microspheres , Protein Subunits