1.
Med Phys ; 38(12): 6407-15, 2011 Dec.
Article in English | MEDLINE | ID: mdl-22149824

ABSTRACT

PURPOSE: Focused ultrasound (FUS) technology is based on heating a small volume of tissue, while keeping the temperature outside the focus region with minimal heating only. Several FUS applications, such as brain and liver, suffer from the existence of ultrasound absorbers in the acoustic path between the transducer and the focus. These absorbers are a potential risk for the FUS therapy since they might cause to unwanted heating outside the focus region. An acoustic simulation based solution for reducing absorbers' heating is proposed, demonstrated, and compared to the standard geometrical solution. The proposed solution uses 3D continuous acoustic holograms, generated by the Gerchberg-Saxton (GS) algorithm, which are described and demonstrated for the first time using ultrasound planar phased-array transducer. METHODS: Holograms were generated using the iterative GS algorithm and fast Fourier transform (FFT) acoustic simulation. The performances of the holograms are demonstrated by temperature elevation images of the absorber, acquired by GE 1.5T MRI scanner equipped with InSightec FUS planar phased-array transducer built out of 986 transmitting elements. RESULTS: The acoustic holographic technology is demonstrated numerically and experimentally using the three letters patterns, "T," "A," and "U," which were manually built into 1 × 1 cm masks to represent the requested target fields. 3D holograms of a focused ultrasound field with a hole in intensity at the absorber region were generated and compared to the standard geometrical solution. The proposed holographic solution results in 76% reduction of heating on absorber, while keeping similar heating at the focus. CONCLUSIONS: In the present work we show for the first time the generation of efficient and uniform continuous ultrasound holograms in 3D. We use the holographic technology to generate a FUS beams that bypasses an absorber in the acoustic path to reduce unnecessary heating and potential clinical risk. The developed technique is superior in performance and flexibility compared to the intuitive geometrical technique that is being used in clinical practice.


Subject(s)
Holography/methods , Imaging, Three-Dimensional/methods , Ultrasonic Surgical Procedures/methods , High-Energy Shock Waves , Surgery, Computer-Assisted/instrumentation
2.
Med Phys ; 37(6): 2934-42, 2010 Jun.
Article in English | MEDLINE | ID: mdl-20632605

ABSTRACT

PURPOSE: Magnetic resonance guided ultrasonic therapy is a promising minimally invasive technology for constantly growing variety of clinical applications. Delivery of focused ultrasound (FUS) energy to the targeted point with optimal intensity is highly desired; however, due to tissue aberrations, optimal focal intensity is not always achieved. Especially in transcranial applications, the acoustic waves are shifted and distorted mainly by the skull. In order to verify that magnetic resonance acoustic radiation force imaging (MR-ARFI) can be used as a focusing tool in transcranial treatments, such an imaging was applied in vivo on a porcine brain via ex vivo human skull. Then, by the use of MR-ARFI technique, an improved ultrasound focusing algorithm is proposed and demonstrated for both transcranial and none brain applications. METHODS: MR-ARFI images were acquired on a GE 1.5 T scanner equipped with InSightec FUS systems ExAblate 2000 and ExAblate 4000. Imaging was performed with MR-ARFI sequences of line-scan spin-echo and single-shot gradient-echo echo-planar. The in-plane resolution of both acquisitions was 0.9 x 0.9 mm2. The total acquisition time of MR-ARFI image was 31 s by the line-scan sequence and 1 s by the echo-planar sequence. An in vivo experiment was performed using FUS transducer, which is built out of 1024 ultrasound transmitting piezoelectric elements at 220 kHz frequency. The transducer was focused into the brain of a pig, which was wrapped in a human skull, in degassed water environment to resemble human treatments. The pig underwent a wide bilateral craniectomy to prevent a bone heating from the ultrasound beams. Two focusing experiments were performed in phantoms using 1 MHz and 710 kHz FUS transducers working with 208 and 225 elements, respectively. In the first experiment, aberration was added virtually to the apparatus by adding random phases to the phase map of the transducer. A simple focusing correction scheme was used, in which the corrected phase of a group of elements was chosen such that it maximizes the radiation force at the focal point. In the second experiment, aberrations made by a human skull were corrected using geometrical and phase based adjustments on segments of the transducer. RESULTS: A maximum displacement of 10 microm was obtained using 1.4 kW acoustic power on a live pig's head that its skull was removed and replaced by ex vivo human skull. Aberration correction using MR-ARFI resulted in near optimal focus, as the radiation force was similar to the nonaberration case. Transcranial, MR-ARFI based aberration correction performed better than CT based aberration correction, a technique that is currently used in brain FUS treatments. CONCLUSIONS: In the present work, the authors show for the first time a result of MR-ARFI in a live brain through ex vivo human skull. They have demonstrated that aberration correction could be done using MR-ARFI by measuring the radiation force at the focal point. Aberration correction using MR-ARFI is a promising noninvasive technique for transcranial focusing, which may result in near optimal focus and more reliable and safer brain FUS treatments.


Subject(s)
Brain/anatomy & histology , Elasticity Imaging Techniques/methods , Therapy, Computer-Assisted/methods , Ultrasonic Therapy/methods , Animals , Brain Diseases/pathology , Brain Diseases/therapy , Humans , Swine