Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Eur J Orthop Surg Traumatol ; 32(7): 1265-1274, 2022 Oct.
Article in English | MEDLINE | ID: mdl-34430988

ABSTRACT

INTRODUCTION: Dynamic Intraligamentary Stabilization (DIS) is a technique for preservation, anatomical repair and stabilization of a freshly injured anterior cruciate ligament (ACL). The main purpose of this study was to evaluate the short-term re-operation rate when compared to traditional autograft reconstruction. METHODS: Four, from the developer independent, centres enrolled patients that underwent ACL repair by DIS, according to the specific indications given by MRI imaging at a minimum follow-up of 12 months. The re-operation rate was recorded as primary outcome. Secondary outcome measures were the postoperative antero-posterior knee laxity (using a portable Rolimeter®), as well as the Tegner, Lysholm and IKDC Scores. RESULTS: A total of 105 patients were investigated with a median follow-up of 21 months. Thirteen patients were lost to follow-up. Of the remaining 92 patients 15 (16.3%) had insufficient functional stability and required subsequent ACL reconstruction. These patients were excluded from further analysis, leaving 77 consecutive patients for a 12 months follow-up. The median age at time of surgery was 30 years for that group. At time of follow-up a median antero-posterior translation difference of 2 mm was measured. None of these patients reported subjective insufficiency (giving way), but in 14 patients (18.2%), the difference of antero-posterior translation was more than 3 mm. We found a median Tegner Score of 5.5, a median Lysholm Score of 95.0 and a median IKDC Score of 89.4. CONCLUSION: The main finding of this multicentre study is a relevant re-operation rate of 16.3%. Another 18.2% showed objective antero-posterior laxity (≥ 3 mm) during testing raising the suspicion of postoperative non-healing. The failure rate of DIS in this study is higher than for reconstruction with an autologous tendon graft. However, our successfully treated patients had a good clinical and functional outcome based on antero-posterior knee laxity and clinical scores, comparable to patients treated by autograft reconstruction.


Subject(s)
Anterior Cruciate Ligament Injuries , Anterior Cruciate Ligament Reconstruction , Anterior Cruciate Ligament/surgery , Anterior Cruciate Ligament Injuries/diagnosis , Anterior Cruciate Ligament Injuries/surgery , Anterior Cruciate Ligament Reconstruction/adverse effects , Anterior Cruciate Ligament Reconstruction/methods , Follow-Up Studies , Humans , Knee Joint/diagnostic imaging , Knee Joint/surgery , Treatment Outcome
2.
Acta Orthop ; 83(6): 629-33, 2012 Dec.
Article in English | MEDLINE | ID: mdl-23140107

ABSTRACT

BACKGROUND AND PURPOSE: Computer navigation in total knee arthroplasty is somewhat controversial. We have previously shown that femoral component positioning is more accurate with computed navigation than with conventional implantation techniques, but the clinical impact of this is unknown. We now report the 5-year outcome of our previously reported 2-year outcome study. METHODS: 78 of initially 84 patients (80 of 86 knees) were clinically and radiographically reassessed 5 (5.1-5.9) years after conventional, image-based, and image-free total knee arthroplasty. The methodology was identical to that used preoperatively and at 2 years, including the Knee Society score (KSS) and the functional score (FS), and AP and true lateral standard radiographs. RESULTS: Although a more accurate femoral component positioning in the navigated groups was obtained, clinical outcome, number of reoperations, KSS, FS, and range of motion were similar between the groups. INTERPRETATION: The increased costs and time for navigated techniques did not translate into better functional and subjective medium-term outcome compared to conventional techniques.


Subject(s)
Arthroplasty, Replacement, Knee/methods , Knee Prosthesis , Prosthesis Failure , Surgery, Computer-Assisted/methods , Tomography, X-Ray Computed/methods , Aged , Arthroplasty, Replacement, Knee/adverse effects , Bone Malalignment/prevention & control , Female , Follow-Up Studies , Humans , Male , Middle Aged , Minimally Invasive Surgical Procedures/adverse effects , Minimally Invasive Surgical Procedures/methods , Monitoring, Intraoperative/methods , Osteoarthritis, Knee/diagnostic imaging , Osteoarthritis, Knee/surgery , Pain Measurement , Postoperative Care/methods , Prosthesis Design , Prosthesis Fitting/methods , Range of Motion, Articular/physiology , Reference Values , Reoperation/statistics & numerical data , Risk Assessment , Surgery, Computer-Assisted/adverse effects , Time Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...