Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
2.
Methods Mol Biol ; 696: 205-24, 2011.
Article in English | MEDLINE | ID: mdl-21063949

ABSTRACT

Imaging mass spectrometry is the method of scanning a sample of interest and generating an "image" of the intensity distribution of a specific analyte. The data sets consist of a large number of mass spectra which are usually acquired with identical settings. Existing data formats are not sufficient to describe an MS imaging experiment completely. The data format imzML was developed to allow the flexible and efficient exchange of MS imaging data between different instruments and data analysis software.For this purpose, the MS imaging data is divided in two separate files. The mass spectral data is stored in a binary file to ensure efficient storage. All metadata (e.g., instrumental parameters, sample details) are stored in an XML file which is based on the standard data format mzML developed by HUPO-PSI. The original mzML controlled vocabulary was extended to include specific parameters of imaging mass spectrometry (such as x/y position and spatial resolution). The two files (XML and binary) are connected by offset values in the XML file and are unambiguously linked by a universally unique identifier. The resulting datasets are comparable in size to the raw data and the separate metadata file allows flexible handling of large datasets.Several imaging MS software tools already support imzML. This allows choosing from a (growing) number of processing tools. One is no longer limited to proprietary software, but is able to use the processing software which is best suited for a specific question or application. On the other hand, measurements from different instruments can be compared within one software application using identical settings for data processing. All necessary information for evaluating and implementing imzML can be found at http://www.imzML.org .


Subject(s)
Databases, Protein/standards , Imaging, Three-Dimensional , Mass Spectrometry/methods , Mass Spectrometry/standards , Programming Languages , Humans , Proteomics/standards , Software
3.
J Am Soc Mass Spectrom ; 19(12): 1808-12, 2008 Dec.
Article in English | MEDLINE | ID: mdl-18804385

ABSTRACT

Accurate mass values as obtainable by Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) were employed in a theoretical study to differentiate between nonmodified and phosphorylated peptides. It was found that for peptide masses up to 1,000 u more than 98% of all theoretical monophosphorylated peptides (all possible combinations of proteinogenic amino acids having one phosphorylation on S, T, or Y) can be distinguished from nonphosphorylated peptides directly by their mass, if mass values are determined with an accuracy of better than +/-0.1 ppm. At a peptide mass of 1,500 u still 70% of all possible monophosphorylated peptides are distinguishable from nonmodified peptides by their accurate mass alone. In contrast to established techniques of data-dependent multidimensional mass spectrometry, only the mass of the precursor ion is necessary to decide upon subsequent fragment ion analysis of a peptide for sequence analysis in an LC-MS/MS investigation of a complex sample, when using a precalculated mass distribution table of theoretical peptides. A mass distribution table of nonphosphorylated and monophosphorylated peptides with a bin width of 0.1 mu was made available via the open web site www.peptidecomposer.com.


Subject(s)
Peptides/chemistry , Peptides/classification , Amino Acids/chemistry , Chromatography, Liquid , Cyclotrons , Databases, Protein , Fourier Analysis , Ions , Isotopes , Molecular Weight , Phosphorylation , Tandem Mass Spectrometry
4.
Rapid Commun Mass Spectrom ; 22(20): 3275-85, 2008 Oct.
Article in English | MEDLINE | ID: mdl-18819119

ABSTRACT

A new scanning microprobe matrix-assisted laser desorption/ionization (SMALDI) ion source for high spatial resolution has been developed for linear ion trap and Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR-MS). The source is fully compatible with commercial ion trap flanges (such as the LTQ series, Thermo Fisher Scientific). The source is designed for atmospheric pressure (AP) operation but is also suitable for mid-pressure operation. The AP mode is especially useful for investigating volatile compounds. The source can be interchanged with other ion sources within a minute when operated in the AP mode. Combining high-lateral resolution MALDI imaging with high mass resolution and high mass accuracy mass spectrometry, available in the FT-ICR mode, provides a new quality of analytical information, e.g. from biological samples. First results obtained with the new ion source demonstrate a maximum lateral resolution of 0.6 by 0.5 microm. Depending on the limit of detection of the chosen mass analyzer, however, the size of the focus had to be enlarged to a diameter of up to 8 microm in the FT-ICR mode, in order to create enough ions for detection. Mass spectra acquired for analytical imaging were obtained from single laser pulses per pixel in all the experiments. This mode allows us to investigate biological thin sections with desorption focus diameters in the micrometer range, known to cause complete evaporation of material under the laser focus with a very limited number of laser pulses. As a first example, peptide samples deposited in microstructures were investigated with the new setup. A high quality and validity of the acquired images were obtained in the ion trap mode due to the low limit of detection. High mass resolution and accuracy but poorer image quality were obtained in the ICR mode due to the lower detection sensitivity of the ICR detector.


Subject(s)
Mass Spectrometry/methods , Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization/methods , Angiotensin II/chemistry , Bradykinin/chemistry , Cyclodextrins , Cyclotrons , Electrophoresis, Gel, Two-Dimensional , Fourier Analysis , Image Processing, Computer-Assisted , Indicators and Reagents , Lasers, Gas , Mass Spectrometry/instrumentation , Microcomputers , Software , Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization/instrumentation
SELECTION OF CITATIONS
SEARCH DETAIL
...