Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Diabetes Technol Ther ; 25(10): 677-688, 2023 10.
Article in English | MEDLINE | ID: mdl-37578778

ABSTRACT

Introduction: Multiple daily injection insulin therapy frequently fails to meet hospital glycemic goals and is prone to hypoglycemia. Automated insulin delivery (AID) with remote glucose monitoring offers a solution to these shortcomings. Research Design and Methods: In a single-arm multicenter pilot trial, we tested the feasibility, safety, and effectiveness of the Omnipod 5 AID System with real-time continuous glucose monitoring (CGM) for up to 10 days in hospitalized patients with insulin-requiring diabetes on nonintensive care unit medical-surgical units. Primary endpoints included the proportion of time in automated mode and percent time-in-range (TIR 70-180 mg/dL) among participants with >48 h of CGM data. Safety endpoints included incidence of severe hypoglycemia and diabetes-related ketoacidosis (DKA). Additional glycemic endpoints, CGM accuracy, and patient satisfaction were also explored. Results: Twenty-two participants were enrolled; 18 used the system for a total of 96 days (mean 5.3 ± 3.1 days per patient), and 16 had sufficient CGM data required for analysis. Median percent time in automated mode was 95% (interquartile range 92%-98%) for the 18 system users, and the 16 participants with >48 h of CGM data achieved an overall TIR of 68% ± 16%, with 0.17% ± 0.3% time <70 mg/dL and 0.06% ± 0.2% time <54 mg/dL. Sensor mean glucose was 167 ± 21 mg/dL. There were no DKA or severe hypoglycemic events. All participants reported satisfaction with the system at study end. Conclusions: The use of AID with a disposable tubeless patch-pump along with remote real-time CGM is feasible in the hospital setting. These results warrant further investigation in randomized trials.


Subject(s)
Diabetes Mellitus, Type 1 , Diabetic Ketoacidosis , Hypoglycemia , Humans , Blood Glucose , Blood Glucose Self-Monitoring/methods , Diabetes Mellitus, Type 1/drug therapy , Feasibility Studies , Hypoglycemia/chemically induced , Hypoglycemia/prevention & control , Hypoglycemic Agents/therapeutic use , Insulin/therapeutic use , Insulin Infusion Systems , Insulin, Regular, Human/therapeutic use , Pilot Projects
2.
Diabetes Care ; 44(4): 1055-1058, 2021 04.
Article in English | MEDLINE | ID: mdl-33563655

ABSTRACT

OBJECTIVE: The use of remote real-time continuous glucose monitoring (CGM) in the hospital has rapidly emerged to preserve personal protective equipment and reduce potential exposures during coronavirus disease 2019 (COVID-19). RESEARCH DESIGN AND METHODS: We linked a hybrid CGM and point-of-care (POC) glucose testing protocol to a computerized decision support system for continuous insulin infusion and integrated a validation system for sensor glucose values into the electronic health record. We report our proof-of-concept experience in a COVID-19 intensive care unit. RESULTS: All nine patients required mechanical ventilation and corticosteroids. During the protocol, 75.7% of sensor values were within 20% of the reference POC glucose with an associated average reduction in POC of 63%. Mean time in range (70-180 mg/dL) was 71.4 ± 13.9%. Sensor accuracy was impacted by mechanical interferences in four patients. CONCLUSIONS: A hybrid protocol integrating real-time CGM and POC is helpful for managing critically ill patients with COVID-19 requiring insulin infusion.


Subject(s)
Blood Glucose/analysis , COVID-19 Drug Treatment , COVID-19 , Critical Illness/therapy , Diabetes Complications , Insulin Infusion Systems , Insulin/administration & dosage , Remote Sensing Technology , Aged , Aged, 80 and over , Algorithms , Blood Glucose/metabolism , Blood Glucose Self-Monitoring/instrumentation , Blood Glucose Self-Monitoring/methods , COVID-19/blood , COVID-19/complications , Diabetes Complications/blood , Diabetes Complications/drug therapy , Equipment and Supplies , Female , Humans , Intensive Care Units , Male , Middle Aged , Point-of-Care Systems , Proof of Concept Study , Remote Sensing Technology/instrumentation , SARS-CoV-2
SELECTION OF CITATIONS
SEARCH DETAIL
...