Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Am J Kidney Dis ; 67(4): 593-600, 2016 Apr.
Article in English | MEDLINE | ID: mdl-26744128

ABSTRACT

BACKGROUND: The Brain in Kidney Disease (BRINK) Study aims to identify mechanisms that contribute to increased risk for cognitive impairment in patients with chronic kidney disease (CKD). We describe the rationale, design, and methods of the study and report baseline recruitment and cognitive function results. STUDY DESIGN: Longitudinal observational cohort study of the epidemiology of cognitive impairment in CKD. The primary aim is to characterize the association between (1) baseline and incident stroke, white matter disease, estimated glomerular filtration rate (eGFR), inflammation, microalbuminuria, and dialysis initiation and (2) cognitive decline over 3 years in a CKD cohort with a mean eGFR<45 mL/min/1.73 m(2). SETTING & PARTICIPANTS: Community-dwelling participants 45 years or older recruited from 4 health systems into 2 groups: reduced eGFR, defined as eGFR<60 mL/min/1.73 m(2) (non-dialysis dependent), and control, defined as eGFR≥60 mL/min/1.73 m(2). PREDICTOR: eGFR group. OUTCOMES: Performance on cognitive function tests and structural brain magnetic resonance imaging. MEASUREMENTS: Sequential cognitive and physical function testing, serum and urine biomarker measurement, and brain magnetic resonance images over 3 years. RESULTS: Of 554 participants, mean age was 69.3 years; 333, 88, and 133 had eGFRs<45 (non-dialysis dependent, nontransplantation), 45 to <60, and ≥60 (controls) mL/min/1.73 m(2), respectively. Mean eGFR in reduced-eGFR participants was 34.3 mL/min/1.73 m(2). Baseline cognitive performance was significantly associated with eGFR in all domains except language. Participants with eGFRs<30 mL/min/1.73 m(2) performed significantly worse than those with eGFRs≥30 mL/min/1.73 m(2) on tests of memory, processing speed, and executive function. Participants with reduced eGFRs overall scored worst on the Immediate Brief Visual-Spatial Memory Test-Revised. LIMITATIONS: Healthy cohort bias, competing risk for death versus cognitive decline. CONCLUSIONS: Cognitive function was significantly worse in participants with eGFRs<30 mL/min/1.73 m(2). Future BRINK analyses will measure risk factors for cognitive decline using the longitudinal data.


Subject(s)
Cognition Disorders/etiology , Renal Insufficiency, Chronic/complications , Aged , Cognition , Cognition Disorders/epidemiology , Cohort Studies , Female , Glomerular Filtration Rate , Humans , Longitudinal Studies , Male , Middle Aged , Prevalence , Prospective Studies , Renal Insufficiency, Chronic/physiopathology , Renal Insufficiency, Chronic/psychology , Research Design
3.
J Am Coll Cardiol ; 52(7): 541-50, 2008 Aug 12.
Article in English | MEDLINE | ID: mdl-18687248

ABSTRACT

OBJECTIVES: Our purpose was to demonstrate that strategically chosen implantable cardioverter-defibrillator (ICD) ventricular tachycardia (VT) or ventricular fibrillation (VF) detection and therapy parameters can reduce the combined incidence of device-delivered shocks, arrhythmic syncope, and untreated sustained symptomatic VT/VF (morbidity index). BACKGROUND: Strategically chosen ICD VT/VF detection and therapy parameters have been shown in previous studies to reduce the number of shocked episodes. In the PREPARE (Primary Prevention Parameters Evaluation) study, these prior strategies were combined with additional strategies specific to primary prevention patients. METHODS: The PREPARE study was a prospective, cohort-controlled study that analyzed 700 patients (biventricular [Bi-V] ICD and non-Bi-V ICD) with primary prevention indications for an ICD from 38 centers followed for 1 year. VT/VF was detected for rates > or =182 beats/min that were maintained for at least 30 of 40 beats. Antitachycardia pacing was programmed as the first therapy for regular rhythms with rates of 182 to 250 beats/min, and supraventricular tachycardia discriminators were used for rhythms < or =200 beats/min. The control cohort consisted of 689 primary prevention patients from the EMPIRIC (Comparison of Empiric to Physician-Tailored Programming of Implantable Cardioverter Defibrillators Trial) (non-Bi-V ICD, physician arm only) and MIRACLE ICD (Multicenter InSync Implantable Cardioversion Defibrillation Randomized Clinical Evaluation) (Bi-V ICD) trials for whom VT/VF detection and therapy programming were not controlled. RESULTS: The PREPARE programming significantly reduced the morbidity index incidence density (0.26 events/patient-year for PREPARE study patients vs. 0.69 control cohort, p = 0.003). The PREPARE study patients were less likely to receive a shock in the first year compared with control patients (9% vs. 17%, p < 0.01). The incidence of untreated VT and arrhythmic syncope was similar between the PREPARE study patients and the control cohort. CONCLUSIONS: Strategically chosen VT/VF detection and therapy parameters can safely reduce shocks and other morbidities associated with ICD therapy in patients receiving an ICD for primary prevention indications. (PREPARE-Primary Prevention Parameters Evaluation; NCT00279279).


Subject(s)
Defibrillators, Implantable , Electric Countershock/statistics & numerical data , Tachycardia, Ventricular/therapy , Ventricular Fibrillation/therapy , Aged , Case-Control Studies , Defibrillators, Implantable/adverse effects , Female , Humans , Incidence , Male , Prospective Studies , Risk Factors , Stroke Volume , Syncope/prevention & control , Tachycardia, Ventricular/physiopathology , Tachycardia, Ventricular/prevention & control , Ventricular Fibrillation/physiopathology , Ventricular Fibrillation/prevention & control
SELECTION OF CITATIONS
SEARCH DETAIL
...